CITY OF SAN JOSÉ, CALIFORNIA
                                          Building Division Informational Handout
                                                                                                Handout No. 6-3
                                                                                                Revised: 8/28/06
Water Heater Information                                                                              Page 1 of 3

 The proceeding information pertains to storage tank type water heaters and includes:

               1.            Prohibited locations,
               2.            When to elevate a water heater off the floor,
               3.            Bracing requirements, and
               4.            Temperature & Pressure relief valve requirements

 1.           Prohibited Locations
              Gas-fired water heaters , which depend on the combustion of fuel for heat, shall not be
              installed in the following locations :
              1. A room used or designed to be used for sleeping purposes,
              2. A bathroom,
              3. A clothes closet, or
              4. In a closet or other confined space opening into a bathroom or bedroom.
                  Exception: Direct vent water heaters.
              5. Water Heaters shall not be installed in attics or other spaces where damage
                  may result from a leaking water heater, without installing an approved safe
                  pan beneath the water heater with a minimum ¾ inch drain to an approved,
                  readily visible location.
              Where not prohibited by other regulations, water heaters may be located under a stairway or
              landing.

 2.           When To Elevate A Water Heater Off The Floor

              Water heaters installed in a garage shall be elevated off the floor.
              Note: Water heaters not installed inside a garage, are not required to be elevated.

              Water heaters generating a glow, spark or flame capable of igniting flammable vapors may be
              installed in a garage, provided the pilots, burners or heating elements and switches are at least 18
              inches above the floor.
              Note: This requirement applies to both gas and electric water heaters.

              Where water heaters installed within a garage are enclosed in a separate, approved compartment
              having access only from outside of the garage, such water heaters may be installed at floor level
              provided the required combustion air is also taken from the exterior.
              Note: When water heaters are installed on a stand or platform base, the base shall be adequately
                     anchored to the floor.

              The above requirements apply to water heater installations as follows:
                     •      New water heater installations,
                     •      Water heater replacements, and
                     •      Water heater relocations inside a garage.
 D:CityWebRootHandouts6-3 HO Water Heater Info.doc
Water Heater Information                                                                           Page 2 of 3

 3.           Water Heater Bracing Requirements

              Experience has shown that water heaters can move or tip over during an earthquake if not
              properly anchored to the walls. Movement of or impact to the water heater may cause leaks in
              gas piping, which in turn may pose a fire hazard. Water leaks from broken water lines may also
              cause damage to floors and walls. Because of this recognized potential for damage, Assembly
              Bill (AB) 1890 was passed into law on September 27, 1989.

              AB 1890 requires all new and replacement water heaters sold in California on or after July
              1, 1991, to be braced, anchored, or strapped to resist falling or displacement due to earthquake
              motion. This applies for installation of all new water heaters and when water heaters are
              replaced or relocated.

              Water heater bracing requirements are as follows :

              1. The Uniform Plumbing Code (UPC) states, water heater strapping shall be at points within
                 the upper one-third and lower one-third of the water heaters vertical dimensions. At the
                 lower point, a minimum distance of four inches shall be maintained above the controls with
                 the strapping. The upper strap is generally installed nine inches below the top of the tank.
              2. The Division of the State Architect's Office (DSA) publishes recommendation regarding
                 bracing of water heater. The DSA recommends two methods of bracing water heaters. They
                 are described as the Tape Method and the Conduit Method.
                      The Tape Method uses only plumber's tape (24-gauge min.) with ledgers, bolts and lag
                      screws. The plumbers tape must completely encircle the water heater and be bolted to a
                      2" X 4" ledger, which is bolted to the wall framing.
                              Note: A 2" X 4" ledger is required at each strap location.
                      The Conduit Method uses round thinwall conduit along with plumber's tape
                      (24-gauge min.), bolts and lag screws.
              3. Water heaters up to 52-gallon size shall have two straps minimum.
                 Larger heaters will require additional bracing in proportion to their sizes to a 52 gallon tank
                 (i.e. - 75 gallon would require 3 straps; 100 gallon would require 4 straps).
                 Note: Some manufacturers make listed straps for water heater installations. Listed bracing
                          straps may be used in lieu of the above methods when installed per the manufacturer's
                          installation instructions.
              4. Also, when water heaters are installed on a stand or platform, the stand shall be adequately
                 anchored to the floor.
                 Note: Water heaters in a garage shall be raised off the floor. Sources of ignition shall be
                          18" min. off the floor. This applies to both gas & electric water heaters.

              Water heater manufacturers provide installation instructions that should be followed for anchoring
              water heaters. Also, the Division of the State Architects Office (DSA) publishes
              recommendations for bracing of water heaters. The DSA recommendations are referenced in the
              City of San Jose's Water Heater Bracing Policy. Also, the Plumbing Code has specific
              regulations regarding water heater bracing. Building Inspectors use these documents and their
              judgment to determine whether water heaters are installed per minimum requirements.




 D:CityWebRootHandouts6-3 HO Water Heater Info.doc
Water Heater Information                                                                            Page 3 of 3



              The Water Heater Bracing Policy is available upon request at the Building Division Permit
              Center. The Building Division will mail or fax this upon request. To request a copy, call
              (408) 535-3555. Leave a voicemail message requesting a copy of the Water Heater Bracing Policy.
              The policy is also available on the Building Division's website at www.sanjoseca.gov
              /building.
              Note: No permit is required for voluntary seismic bracing of water heaters.

 4.           Temperature & pressure relief (T & P) valve requirements –

              Storage-type water heaters and hot water boilers shall be provided with, in addition to the
              primary temperature controls, a combination temperature and pressure relief valve (T & P valve).
              The T & P valve shall be constructed, listed, and installed in accordance with nationally
              recognized applicable standards.

              The following 11 items pertain to T & P valve installation requirements :

              1.  Each T & P valve shall be an approved type with a drain.
              2.  A union must be installed in the drain line near the water heater to facilitate removal and
                  replacement of the water heater and/or the T & P valve.
                  Exception: If a water heater can be replaced without adversely affecting the drainpipe
                  installation, the union may be omitted.
              3.  No shutoff valve shall be installed in the relief valve drain line system.
              4.  T & P valves located inside a building shall be provided with a drain, not smaller than the
                  relief valve outlet, of galvanized steel, hard drawn copper piping & fittings, or listed relief
                  valve drain tube with fittings which will not reduce the internal bore of the piping.
              5.  The piping shall extend from the valve to the outside of the building with the end of the
                  pipe not more than two feet nor less than six inches above the ground pointing downward.
                  Note: It is not acceptable to terminate the T & P in the underfloor area.
              6.  When a water heater is located in a garage, the T & P drainpipe may terminate in the
                  garage. The piping shall extend from the valve to within 12 inches but not less than
                  6 inches above the floor and point downward.
                  Note: Water heaters not located in a garage cannot terminate the T & P drain in the
                  garage. These drain lines must terminate to the outside.
              7.  T & P drainage piping shall be run independently from other drainage piping.
                  For example : It is not acceptable to combine T & P drains with A/C condensate drainage
                  piping or water heater drain pan piping. Also, it is not acceptable to terminate the T & P
                  drain into a water heater drain pan (Smitty pan).
              8.  The T & P drain shall not be connected to the sanitary sewer.
              9.  No part of such drain shall be trapped.
              10. The terminal end of the drainpipe shall not be threaded.
              11. For water heaters installed in a basement or in locations where it is not possible for the T
                  & P relief to achieve gravity drainage, a special provision for drainage is allowed. A
                  handout is available at the Permit Center regarding installation procedures for such cases.
 Additional information can be obtained by visiting our website at www.sanjoseca.gov/building/, or by
 calling our Information Inspector's voice mail at (408) 535-3555 and leaving a detailed message.
 D:CityWebRootHandouts6-3 HO Water Heater Info.doc

Weitere ähnliche Inhalte

Ähnlich wie SEISMIC WATER HEATER

7200 rev1 plumbing
7200 rev1 plumbing7200 rev1 plumbing
7200 rev1 plumbingbhattbhai
 
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...Thorne & Derrick UK
 
Comparison between Systems
Comparison between SystemsComparison between Systems
Comparison between SystemsVictor Ashkenazy
 
Preliminary design submittal presentation
Preliminary design submittal presentationPreliminary design submittal presentation
Preliminary design submittal presentationJefferson Brewer
 
Tema 3. Diseño de Tanques
Tema 3. Diseño de TanquesTema 3. Diseño de Tanques
Tema 3. Diseño de Tanquesgreilyncastillo
 
Residential manual (9)
Residential manual (9)Residential manual (9)
Residential manual (9)Maria S
 
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...miscott57
 
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdf
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdfMastering the Art of Water Heater Installation A Comprehensive Guide.pdf
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdfEco 1 Plumbing LLC
 
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014Gerald McClain
 
TRIC Trenchless LA building & safety
TRIC Trenchless LA building & safetyTRIC Trenchless LA building & safety
TRIC Trenchless LA building & safetyMEL3360
 
Service solahart cikarang hp 081313462267
Service solahart cikarang  hp 081313462267Service solahart cikarang  hp 081313462267
Service solahart cikarang hp 081313462267Service Solahart
 
Hot Tub Specifications Guide
Hot Tub Specifications GuideHot Tub Specifications Guide
Hot Tub Specifications Guideaquatic123
 
Sun Seeker Installation Manual
Sun Seeker Installation ManualSun Seeker Installation Manual
Sun Seeker Installation ManualSolartec Global
 
NFPA 13 Installation of Sprinkler Systems.ppt
NFPA 13 Installation of Sprinkler Systems.pptNFPA 13 Installation of Sprinkler Systems.ppt
NFPA 13 Installation of Sprinkler Systems.pptssuser135ef41
 

Ähnlich wie SEISMIC WATER HEATER (20)

7200 rev1 plumbing
7200 rev1 plumbing7200 rev1 plumbing
7200 rev1 plumbing
 
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...
Heat Tracing - Fire Protection Association's RC38 Recommendation for Frost Pr...
 
holdrite-20-fmwh-cut_sheet
holdrite-20-fmwh-cut_sheetholdrite-20-fmwh-cut_sheet
holdrite-20-fmwh-cut_sheet
 
Comparison between Systems
Comparison between SystemsComparison between Systems
Comparison between Systems
 
Harga ariston pemanas air jakarta 082113812149
Harga ariston pemanas air jakarta 082113812149Harga ariston pemanas air jakarta 082113812149
Harga ariston pemanas air jakarta 082113812149
 
Preliminary design submittal presentation
Preliminary design submittal presentationPreliminary design submittal presentation
Preliminary design submittal presentation
 
Manual filtro pentair
Manual filtro pentair Manual filtro pentair
Manual filtro pentair
 
Fs sprinkler systems
Fs sprinkler systemsFs sprinkler systems
Fs sprinkler systems
 
Turbine vacuum system.ppt
Turbine vacuum system.pptTurbine vacuum system.ppt
Turbine vacuum system.ppt
 
Tema 3. Diseño de Tanques
Tema 3. Diseño de TanquesTema 3. Diseño de Tanques
Tema 3. Diseño de Tanques
 
Residential manual (9)
Residential manual (9)Residential manual (9)
Residential manual (9)
 
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...
Rain Soft Gold Series Water Treatment System Installation & Service Manual (w...
 
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdf
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdfMastering the Art of Water Heater Installation A Comprehensive Guide.pdf
Mastering the Art of Water Heater Installation A Comprehensive Guide.pdf
 
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014
GeothermalHeatPump-DeerCrossingStillwaterOK first Four years revised Jun 26-2014
 
Sealed system components
Sealed system componentsSealed system components
Sealed system components
 
TRIC Trenchless LA building & safety
TRIC Trenchless LA building & safetyTRIC Trenchless LA building & safety
TRIC Trenchless LA building & safety
 
Service solahart cikarang hp 081313462267
Service solahart cikarang  hp 081313462267Service solahart cikarang  hp 081313462267
Service solahart cikarang hp 081313462267
 
Hot Tub Specifications Guide
Hot Tub Specifications GuideHot Tub Specifications Guide
Hot Tub Specifications Guide
 
Sun Seeker Installation Manual
Sun Seeker Installation ManualSun Seeker Installation Manual
Sun Seeker Installation Manual
 
NFPA 13 Installation of Sprinkler Systems.ppt
NFPA 13 Installation of Sprinkler Systems.pptNFPA 13 Installation of Sprinkler Systems.ppt
NFPA 13 Installation of Sprinkler Systems.ppt
 

SEISMIC WATER HEATER

  • 1. CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Handout No. 6-3 Revised: 8/28/06 Water Heater Information Page 1 of 3 The proceeding information pertains to storage tank type water heaters and includes: 1. Prohibited locations, 2. When to elevate a water heater off the floor, 3. Bracing requirements, and 4. Temperature & Pressure relief valve requirements 1. Prohibited Locations Gas-fired water heaters , which depend on the combustion of fuel for heat, shall not be installed in the following locations : 1. A room used or designed to be used for sleeping purposes, 2. A bathroom, 3. A clothes closet, or 4. In a closet or other confined space opening into a bathroom or bedroom. Exception: Direct vent water heaters. 5. Water Heaters shall not be installed in attics or other spaces where damage may result from a leaking water heater, without installing an approved safe pan beneath the water heater with a minimum ¾ inch drain to an approved, readily visible location. Where not prohibited by other regulations, water heaters may be located under a stairway or landing. 2. When To Elevate A Water Heater Off The Floor Water heaters installed in a garage shall be elevated off the floor. Note: Water heaters not installed inside a garage, are not required to be elevated. Water heaters generating a glow, spark or flame capable of igniting flammable vapors may be installed in a garage, provided the pilots, burners or heating elements and switches are at least 18 inches above the floor. Note: This requirement applies to both gas and electric water heaters. Where water heaters installed within a garage are enclosed in a separate, approved compartment having access only from outside of the garage, such water heaters may be installed at floor level provided the required combustion air is also taken from the exterior. Note: When water heaters are installed on a stand or platform base, the base shall be adequately anchored to the floor. The above requirements apply to water heater installations as follows: • New water heater installations, • Water heater replacements, and • Water heater relocations inside a garage. D:CityWebRootHandouts6-3 HO Water Heater Info.doc
  • 2. Water Heater Information Page 2 of 3 3. Water Heater Bracing Requirements Experience has shown that water heaters can move or tip over during an earthquake if not properly anchored to the walls. Movement of or impact to the water heater may cause leaks in gas piping, which in turn may pose a fire hazard. Water leaks from broken water lines may also cause damage to floors and walls. Because of this recognized potential for damage, Assembly Bill (AB) 1890 was passed into law on September 27, 1989. AB 1890 requires all new and replacement water heaters sold in California on or after July 1, 1991, to be braced, anchored, or strapped to resist falling or displacement due to earthquake motion. This applies for installation of all new water heaters and when water heaters are replaced or relocated. Water heater bracing requirements are as follows : 1. The Uniform Plumbing Code (UPC) states, water heater strapping shall be at points within the upper one-third and lower one-third of the water heaters vertical dimensions. At the lower point, a minimum distance of four inches shall be maintained above the controls with the strapping. The upper strap is generally installed nine inches below the top of the tank. 2. The Division of the State Architect's Office (DSA) publishes recommendation regarding bracing of water heater. The DSA recommends two methods of bracing water heaters. They are described as the Tape Method and the Conduit Method. The Tape Method uses only plumber's tape (24-gauge min.) with ledgers, bolts and lag screws. The plumbers tape must completely encircle the water heater and be bolted to a 2" X 4" ledger, which is bolted to the wall framing. Note: A 2" X 4" ledger is required at each strap location. The Conduit Method uses round thinwall conduit along with plumber's tape (24-gauge min.), bolts and lag screws. 3. Water heaters up to 52-gallon size shall have two straps minimum. Larger heaters will require additional bracing in proportion to their sizes to a 52 gallon tank (i.e. - 75 gallon would require 3 straps; 100 gallon would require 4 straps). Note: Some manufacturers make listed straps for water heater installations. Listed bracing straps may be used in lieu of the above methods when installed per the manufacturer's installation instructions. 4. Also, when water heaters are installed on a stand or platform, the stand shall be adequately anchored to the floor. Note: Water heaters in a garage shall be raised off the floor. Sources of ignition shall be 18" min. off the floor. This applies to both gas & electric water heaters. Water heater manufacturers provide installation instructions that should be followed for anchoring water heaters. Also, the Division of the State Architects Office (DSA) publishes recommendations for bracing of water heaters. The DSA recommendations are referenced in the City of San Jose's Water Heater Bracing Policy. Also, the Plumbing Code has specific regulations regarding water heater bracing. Building Inspectors use these documents and their judgment to determine whether water heaters are installed per minimum requirements. D:CityWebRootHandouts6-3 HO Water Heater Info.doc
  • 3. Water Heater Information Page 3 of 3 The Water Heater Bracing Policy is available upon request at the Building Division Permit Center. The Building Division will mail or fax this upon request. To request a copy, call (408) 535-3555. Leave a voicemail message requesting a copy of the Water Heater Bracing Policy. The policy is also available on the Building Division's website at www.sanjoseca.gov /building. Note: No permit is required for voluntary seismic bracing of water heaters. 4. Temperature & pressure relief (T & P) valve requirements – Storage-type water heaters and hot water boilers shall be provided with, in addition to the primary temperature controls, a combination temperature and pressure relief valve (T & P valve). The T & P valve shall be constructed, listed, and installed in accordance with nationally recognized applicable standards. The following 11 items pertain to T & P valve installation requirements : 1. Each T & P valve shall be an approved type with a drain. 2. A union must be installed in the drain line near the water heater to facilitate removal and replacement of the water heater and/or the T & P valve. Exception: If a water heater can be replaced without adversely affecting the drainpipe installation, the union may be omitted. 3. No shutoff valve shall be installed in the relief valve drain line system. 4. T & P valves located inside a building shall be provided with a drain, not smaller than the relief valve outlet, of galvanized steel, hard drawn copper piping & fittings, or listed relief valve drain tube with fittings which will not reduce the internal bore of the piping. 5. The piping shall extend from the valve to the outside of the building with the end of the pipe not more than two feet nor less than six inches above the ground pointing downward. Note: It is not acceptable to terminate the T & P in the underfloor area. 6. When a water heater is located in a garage, the T & P drainpipe may terminate in the garage. The piping shall extend from the valve to within 12 inches but not less than 6 inches above the floor and point downward. Note: Water heaters not located in a garage cannot terminate the T & P drain in the garage. These drain lines must terminate to the outside. 7. T & P drainage piping shall be run independently from other drainage piping. For example : It is not acceptable to combine T & P drains with A/C condensate drainage piping or water heater drain pan piping. Also, it is not acceptable to terminate the T & P drain into a water heater drain pan (Smitty pan). 8. The T & P drain shall not be connected to the sanitary sewer. 9. No part of such drain shall be trapped. 10. The terminal end of the drainpipe shall not be threaded. 11. For water heaters installed in a basement or in locations where it is not possible for the T & P relief to achieve gravity drainage, a special provision for drainage is allowed. A handout is available at the Permit Center regarding installation procedures for such cases. Additional information can be obtained by visiting our website at www.sanjoseca.gov/building/, or by calling our Information Inspector's voice mail at (408) 535-3555 and leaving a detailed message. D:CityWebRootHandouts6-3 HO Water Heater Info.doc