Diese Präsentation wurde erfolgreich gemeldet.
Wir verwenden Ihre LinkedIn Profilangaben und Informationen zu Ihren Aktivitäten, um Anzeigen zu personalisieren und Ihnen relevantere Inhalte anzuzeigen. Sie können Ihre Anzeigeneinstellungen jederzeit ändern.
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
IT25...
IT25...
Installation: hazardous areas - Zo...
YOUR PARTNER FOR SAFETY
Since 1961
IT25...
245APPROX.
CH42 CH42 CH42 CH42 CH42
245APPROX
245APPROX
215APPROX.
245APPROX
IT...
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
SM2021F - SM2021IIC
SM2021F-SM2021IIC
SM2021IIC
SM...
YOUR PARTNER FOR SAFETY
Since 1961
SM2021F-SM2021IIC
NOT ENABLED
ENABLED
INSERTION
NOT ENABLE
ENABLE
INSERTION
A
C
E
D
B
S...
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
ETH2... - S2
ETH2...–S2
S2
ETH2
ETH2C
Installation...
YOUR PARTNER FOR SAFETY
Since 1961
ETH2V12CA 12V - 50/60Hz 13VA 80
ETH2C12VCA 12V - 50/60Hz 13VA 80
ETH2V24CA 24V - 50/60H...
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
MQ-BQ / MQ-BC
MQ-BQ/MQ-BC
Air conveyor steel ring ...
YOUR PARTNER FOR SAFETY
Since 1961
MQ-BQ/MQ-BC
AE
F
15
B
ØC
ØD
E
F
ØC
ØD
MQBQ304	 400	 350	 390	 315	 102	 297	 8,00	 A
MQ...
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
READ / RERAC
READ/RERAC
READ
RERAC
Installation: h...
YOUR PARTNER FOR SAFETY
Since 1961
READ1000W 230V - 50/60Hz 1000 A
READ2000W 230V - 50/60Hz 2000 A RERAC21000 230V - 50/60...
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
WEATHERPROOFCONTROLPANELS
Framework And Panel 15-2...
YOUR PARTNER FOR SAFETY
Since 1961
WEATHERPROOFCONTROLPANELS
12 - Feam Catalogue 03
Weatherproof Control Panels
Reference ...
Nächste SlideShare
Wird geladen in …5
×

06 pinze di-terra-eng

806 Aufrufe

Veröffentlicht am

  • Loggen Sie sich ein, um Kommentare anzuzeigen.

  • Gehören Sie zu den Ersten, denen das gefällt!

06 pinze di-terra-eng

  1. 1. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment IT25... IT25... Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G Ex Earthing clamps EARTHING CLAMPS Feam Catalogue 03 - 1 Mechanical characteristics APPLICATIONS Haft nylon shock proof insulating Contacts elastic phosphor bronze, suitable for fastening on tank tails 8-11mm Contact support brass Cable entry marine brass gland Earthing cable external diameter 8-11mm (NOT SUPPLIED) • IT 25… EARTHING CLAMPS IS USED TO CONNECT TANKERS TO GROUND DURING LOADING AND UNLOADING OPERATIONS. • CONNECTING THE CLAMP TO TANK TAIL, the grounding circuits is automatically closed. EATHING CLAMPS ATEX 94/9/EC GOST-R (RTR / RTN) EXECUTION II 2 G Ex d IIC T6 1 Ex d IIC T6 INSTALLATION ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 PROTECTION DEGREE IP66 IP66 CERTIFICATE REF. CESI 05 ATEX 005 POCC IT. ME92.B02925 RULES OF COMPLIANCE EN 50014: 1997 + A1 and A2; EN 50018:2000 + A1; ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004;
  2. 2. YOUR PARTNER FOR SAFETY Since 1961 IT25... 245APPROX. CH42 CH42 CH42 CH42 CH42 245APPROX 245APPROX 215APPROX. 245APPROX IT25 A IT25F B IT25XSS C IT25XF D IT25XAM E Ex Earthing clamps IT25... - Technical Features 2 - Feam Catalogue 03 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. TYPE TYPE OF CONNECTION DESCRIPTION WEIGHT [Kg] DETAIL IT25 NORMAL SPRING CLAMPING 0,70 A IT25F SPRING CLAMPING & MECHANICAL FIXING 0,70 B IT25XSS THIN STRUCTURE CLAMPING 0,70 C IT25XF METAL BARREL CLAMPING 0,70 D IT25XAM ROUND SHAPED EARTHING FIXING 0,70 E
  3. 3. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment SM2021F - SM2021IIC SM2021F-SM2021IIC SM2021IIC SM2021F Feam Catalogue 03 - 3 Ex Grounding electronic systems ELECTRONIC SYSTEM TO VERIFY THE GROUNDING CONNECTION Mechanical characteristics Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless sttel Internal plate hot dip galvanized steel External Painting poxy powders RAL-9006 Grey coloured Hinges casting on body and cover enclosure (SM2021F) ATEX / IECEx / GOST NEC 505 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 Division 1 2 1 2 1 2 X X X X X X X X X X X SM2021F ELECTRONIC SYSTEM ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex td IIB+H2 T6…T3 II 2 (1) G Ex db [ia IIA/B/C] IIB+H2 T6…T3 II 2 (2) G Ex db [ib IIA/B/C] IIB+H2 T6…T3 II 2 D Ex tb IIIC T85°C…150°C Ex db IIB+H2 T6…T3 Ex db [ia/ib] IIB+H2 T6…T3 Ex tb IIIC T85°C…T150°C Ex db IIB+H2 T6…T3 Ex db [ia/ib] IIB+H2 T6…T3 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 Ex tD A21 T85°C…t150°C 1Ex d IIB+H2 U 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 A21 TA85°C AMBIENT TEMP. -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +60°C -60°C ÷ +130°C PROTEC.DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 13 ATEX 0022X IECEx BKI 09.0005 CEPEL 12.2139 POCC IT. ME92.B02924 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0:2004; EN 60079-1:2004; EN 60079-11:2006; EN 61241-0:2004; EN 61241-1:2004 IEC 60079-0; IEC 60079-1; IEC 60079-11; IEC 61241-0; IEC 61241-1 ABNT NBR IEC 60079-0:2008; ABNT NBR IEC 60079-1:2009; ABNT NBR IEC 60529-0:2009 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002 SM2021IIC ELECTRONIC SYSTEM ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex db IIC T3…T6 II 2(1/2) GD Ex d [ia/ib] IIC T6 II 2 D Ex tb IIIC T85°C...T200°C II 2 D Ex tb IIIC T85°C Ex db IIC T3…T6 Ex d [ia/ib] IIC T6 Ex tb IIIC T85°C...T200°C Ex tb IIIC T85°C Ex db IIC T3…T6 Ex db [ia/ib] IIC T6 Ex tb IIIC T85°C…T150°C Ex tb [ia/ib] IIIC T85°C Ex d IIC T6…T3 Gb Ex tb IIIC T85°C…T150°C Db Ex d [ia/ib] IIC T6 Gb Ex tb [ia/ib] IIIC T85°C Db Ex d IIC T6…T3 Gb Ex tb IIIC T85°C…T150°C Db Ex d [ia/ib] IIC T6 Gb Ex tb [ia/ib] IIIC T85°C Db AMBIENT TEMP. -60°C ÷ +80°C -60°C ÷ +80°C -60°C ÷ +80°C -60°C ÷ +80°C -60°C ÷ +80°C PROTEC.DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 13 ATEX 0023X IECEx BKI 11.0010 CEPEL 12.2137 POCC IT. ME92.B02924 - RULES OF COMPLIANCE EN 60079-0:2009; EN 60079-1:2007; EN 60079-11:2007; EN 60079-31:2009 IEC 60079-0:2007; IEC 60079-1:2007; IEC 60079-11:2006; IEC 60079-11:2008 ABNT NBR IEC 60079-0:2008; ABNT NBR IEC 60079-1:2009; ABNT NBR IEC 60529:2009; ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  4. 4. YOUR PARTNER FOR SAFETY Since 1961 SM2021F-SM2021IIC NOT ENABLED ENABLED INSERTION NOT ENABLE ENABLE INSERTION A C E D B SM2021F 285 245 160 276 169 12,00 A SM2021IIC 285 245 169 226 170 13,00 B NOT ENABLED ENABLED INSERTION NOT ENABLE ENABLE INSERTION C A C BE A B 4 - Feam Catalogue 03 Ex Grounding electronic systems SM2021F - SM2021IIC Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Reference Details Reference Details APPLICATIONS: They are used to control grounding continuity during thanks loading and unloading operations. Thanks normally arrive electrostatically loaded, and an imperfect earthing might cause fire originated by a spark in presence of gas. The earthing control system is composed of a marine grade copper free aluminium enclosure, as above described, inside fitted with the earthing control electronic circuit SM-2001, which is normally set at 20 ohm, and authorize thanks loading/unloading when resistance is less than 20 ohm. An intrinsically safety barrier placed inside the equipment and connected via the included cable clamp kit to the electronic system allows the one and only verification of the correct / perfect ground connection of the tank. The tank ground connection is to made only with proper grounding clamp series IT (not included). Enclosure is provided with: NOT AVAILABLE red light – AVAILABLE green light - INSERTION push button. Red electronic system SM.. pilot light remain lit till grounding clamp IT series (not included) is perfect connected to vehicle’s earthing bar. Insertion push button is pressed for at least 2sec. If the resistance measured by electronic circuit is less than 20ohm, SM electronic system allows for loading and unloading operations. Earthing clamp for verification is normally complete with 8m of cable. FOR GROUNDING TANKS CONNECTIONS, PLEASE USE EARTHING CLAMPS IT.. SERIES SHOWED ON PREVIOUS BULLETIN CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] DETAIL
  5. 5. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment ETH2... - S2 ETH2...–S2 S2 ETH2 ETH2C Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D Feam Catalogue 03 - 5 Ex Acustic signallers ACUSTIC SIGNALLERS On Request Accessories: • External epoxy painting (any colours) • Threaded cable entry different than standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Ring bell (eth2c…) painted steel ACUSTIC SIGNALLERS ETH2… ATEX 94/9/EC GOST-R (RTR / RTN) EXECUTION II 2 G Ex d IIC T6 II 2 D Ex tD A21 T85°C 1 Ex d IIC T6 Ex tD A21 T85°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 IP66 CERTIFICATE REF. INERIS 04 ATEX 0095 POCC IT. ME92.B02925 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ACUSTIC SIGNALLERS S2… ATEX 94/9/EC GOST-R (RTR / RTN) EXECUTION II 2 G Ex d IIC T5 II 2 D Ex tD A21 T100°C 1 Ex d IIC T5 Ex tD A21 T100°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 IP66 CERTIFICATE REF. INERIS 05 ATEX 0041X POCC IT. ME92.B02925 RULES OF COMPLIANCE EN 50014: 1997 + A1 and A2; EN 50018:2000 + A1; EN 50281-1-1:1998 + A1 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004
  6. 6. YOUR PARTNER FOR SAFETY Since 1961 ETH2V12CA 12V - 50/60Hz 13VA 80 ETH2C12VCA 12V - 50/60Hz 13VA 80 ETH2V24CA 24V - 50/60Hz 13VA 80 ETH2C24VCA 24V - 50/60Hz 13VA 80 ETH2V48CA 48V - 50/60Hz 13VA 80 ETH2C48VCA 48V - 50/60Hz 13VA 80 ETH2V110CA 110V - 50/60Hz 13VA 80 ETH2C110VCA 110V - 50/60Hz 13VA 80 ETH2V230CA 230V - 50/60Hz 13VA 80 ETH2C230VCA 230V - 50/60Hz 13VA 80 ETH2V12CC 12V - c.c. 8VA 80 ETH2C12VCC 12V - c.c. 8VA 80 ETH2V24CC 24V - c.c. 8VA 80 ETH2C24VCC 24V - c.c. 8VA 80 ETH2V48CC 48V - c.c. 8VA 80 ETH2C48VCC 48V - c.c. 8VA 80 S2V12CA 12V - AC/DC 90W 100 S2V24CA 24V - AC/DC 90W 100 S2V48CA 48V - AC/DC 90W 100 S2V110CA 110V - AC/DC 90W 100 S2V230CA 230V - AC/DC 90W 100 ETH2… 150 135 GK 3/4" - - T6 (-20°C / +55°C) T85°C (Ta -20°C / +55°C) 2,00 A ETH2C… 168 140 GK 3/4" - - T6 (-20°C / +55°C) T85°C (Ta -20°C / +55°C) 2,50 B S2… 145 203 GK 3/4" 104 54 T5 (-20°C / +55°C) T100°C (Ta -20°C / +55°C) 2,60 C ETH2...–S2 DONOTOPENWHENANEXPLOSIVEATMOSPHEREMAYBEPRESENT NONAPRIREQUANDOPUO'ESSEREPRESENTE Ta-20°C/+55°C V90W100VA UNAATMOSFERAESPLOSIVA S4-60% S2II2GD EExdIICT5IP66T100°C INERIS05ATEX0041X 0575 40.20.01 MILANOITALY TREZZANOS/N SYREN SIRENA 6STARTSPERHOUR 6AVVIAM/ORA DUTY SERVIZIO DONOTOPENWHENANEXPLOSIVEATMOSPHEREMAYBEPRESENT NONAPRIREQUANDOPUO'ESSEREPRESENTE Ta-20°C/+55°C V90W100VA UNAATMOSFERAESPLOSIVA S4-60% S2II2GD EExdIICT5IP66T100°C INERIS05ATEX0041X 0575 40.20.01 MILANOITALY TREZZANOS/N SYREN SIRENA 6STARTSPERHOUR 6AVVIAM/ORA DUTY SERVIZIO B B ØC ØC A A DONOTOPENWHENANEXPLOSIVEATMOSPHEREMAYBEPRESENT NONAPRIREQUANDOPUO'ESSEREPRESENTE Ta-20°C/+55°C V90W100VA UNAATMOSFERAESPLOSIVA S4-60% S2II2GD EExdIICT5IP66T100°C INERIS05ATEX0041X 0575 40.20.01 MILANOITALY TREZZANOS/N SYREN SIRENA 6STARTSPERHOUR 6AVVIAM/ORA DUTY SERVIZIO B E ØC ØC A DA B C Ex Acustic signallers ETH2... - S2 Technical Features 6 - Feam Catalogue 03 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Reference Details TYPE VOLTAGE CONSUMPITION DUTY SOUND INTENSITY [db] CODE A [mm] B [mm] ØC [mm] D [mm] E [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS S4-60% 6 avv/h S4-60% 6 avv/h S4-60% 6 avv/h S4-60% 6 avv/h S4-60% 6 avv/h
  7. 7. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment MQ-BQ / MQ-BC MQ-BQ/MQ-BC Air conveyor steel ring Fe 37B Impeller mounted overhung at the mototr shaft Painting by immersion in bath electrophoresis and subsequent firing in a kiln • for aeration plants where it is necessary to remove heat, smoke, stale air • PLEASE NOTE THAT IN ORDER TO MAKING EFFECTIVE CORRECT WORKING OF FANS, MUST REPLACE THE EXTACTED AIR WITH SAME VOLUME AIR INTRODUCED IN ENVIRONMENT Feam Catalogue 03 - 7 Mechanical characteristics APPLICATIONS Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G AXIAL FAN LOW PRESSURE Ex Axial fan On Request Accessories: • External epoxy painting (any colours) • Threaded cable entry different than standard AXIAL FAN ATEX 94/9/EC GOST-R (RTR / RTN) EXECUTION II 2 G Ex d IIB T3/T4 II 2 G Ex d IIC T3/T4 - INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP65 IP65 CERTIFICATE REF. INERIS 05 ATEX 0025X POCC IT. MГ01.B02998 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99
  8. 8. YOUR PARTNER FOR SAFETY Since 1961 MQ-BQ/MQ-BC AE F 15 B ØC ØD E F ØC ØD MQBQ304 400 350 390 315 102 297 8,00 A MQBQ354 450 400 440 365 102 297 10,00 A MQBQ404 500 450 490 415 107 302 11,00 A MQBQ454 550 500 540 465 108 318 12,00 A MQBQ504 600 550 590 515 123 333 15,00 A MQBQ506 600 550 590 515 123 333 18,00 A MQBQ554 680 630 665 567 125 355 19,00 A MQBQ556 680 630 665 567 125 355 22,00 A MQBQ604 730 680 715 617 140 370 24,00 A MQBQ606 730 680 715 617 140 370 26,00 A MQBQ304M 400 350 390 315 102 297 8,00 A MQBQ354M 450 400 440 365 102 297 10,00 A MQBQ404M 500 450 490 415 107 302 11,00 A MQBQ454M 550 500 540 465 108 318 12,00 A MQBQ504M 600 550 590 515 123 333 15,00 A MQBQ506M 600 550 590 515 123 333 18,00 A MQBQ554M 680 630 665 567 125 355 19,00 A MQBQ556M 680 630 665 567 125 355 22,00 A MQBQ604M 730 680 715 617 140 370 24,00 A MQBQ606M 730 680 715 617 140 370 26,00 A MQBQ304 1400 400V - 50Hz 0,18 1750 A MQBQ354 1400 400V - 50Hz 0,25 3000 A MQBQ404 1400 400V - 50Hz 0,25 4500 A MQBQ454 1400 400V - 50Hz 0,33 5500 A MQBQ504 1400 400V - 50Hz 0,5 8000 A MQBQ506 900 400V - 50Hz 0,33 5500 A MQBQ554 1400 400V - 50Hz 0,75 12000 A MQBQ556 900 400V - 50Hz 0,5 700 A MQBQ604 1400 400V - 50Hz 1,00 15000 A MQBQ606 900 400V - 50Hz 0,75 10000 A MQBQ304M 1400 230V - 50Hz 0,18 1750 A MQBQ354M 1400 230V - 50Hz 0,25 3000 A MQBQ404M 1400 230V - 50Hz 0,25 4500 A MQBQ454M 1400 230V - 50Hz 0,33 5500 A MQBQ504M 1400 230V - 50Hz 0,5 8000 A MQBQ506M 900 230V - 50Hz 0,33 5500 A MQBQ554M 1400 230V - 50Hz 0,75 12000 A MQBQ556M 900 230V - 50Hz 0,5 700 A MQBQ604M 1400 230V - 50Hz 1,00 15000 A MQBQ606M 900 230V - 50Hz 0,75 10000 A MQBC304 1400 400V - 50Hz 0,18 1750 B MQBC354 1400 400V - 50Hz 0,25 3000 B MQBC404 1400 400V - 50Hz 0,25 4500 B MQBC454 1400 400V - 50Hz 0,33 5500 B MQBC504 1400 400V - 50Hz 0,5 8000 B MQBC506 900 400V - 50Hz 0,33 5500 B MQBC554 1400 400V - 50Hz 0,75 12000 B MQBC556 900 400V - 50Hz 0,5 700 B MQBC604 1400 400V - 50Hz 1,00 15000 B MQBC606 900 400V - 50Hz 0,75 10000 B MQBC304M 1400 230V - 50Hz 0,18 1750 B MQBC354M 1400 230V - 50Hz 0,25 3000 B MQBC404M 1400 230V - 50Hz 0,25 4500 B MQBC454M 1400 230V - 50Hz 0,33 5500 B MQBC504M 1400 230V - 50Hz 0,5 8000 B MQBC506M 900 230V - 50Hz 0,33 5500 B MQBC554M 1400 230V - 50Hz 0,75 12000 B MQBC556M 900 230V - 50Hz 0,5 700 B MQBC604M 1400 230V - 50Hz 1,00 15000 B MQBC606M 900 230V - 50Hz 0,75 10000 B MQBC304 - - 390 315 100 295 7,00 B MQBC354 - - 440 365 100 295 8,50 B MQBC404 - - 490 415 105 300 9,50 B MQBC454 - - 540 465 106 316 10,50 B MQBC504 - - 590 515 121 331 13,00 B MQBC506 - - 590 515 121 331 16,00 B MQBC554 - - 665 567 121 331 16,50 B MQBC556 - - 665 567 121 331 19,50 B MQBC604 - - 715 617 138 368 21,00 B MQBC606 - - 715 617 138 368 23,00 B MQBC304M - - 390 315 100 295 7,00 B MQBC354M - - 440 365 100 295 8,50 B MQBC404M - - 490 415 105 300 9,50 B MQBC454M - - 540 465 106 316 10,50 B MQBC504M - - 590 515 121 331 13,00 B MQBC506M - - 590 515 121 331 16,00 B MQBC554M - - 665 567 121 331 16,50 B MQBC556M - - 665 567 121 331 19,50 B MQBC604M - - 715 617 138 368 21,00 B MQBC606M - - 715 617 138 368 23,00 B A B 8 - Feam Catalogue 03 Ex Axial fan MQ-BQ / MQ-BC Technical Features Reference Details CODE A [mm] B [mm] ØC mm] ØD [mm] E [mm] F [mm] CODE TURNS/min. VOLTAGE Hp. m³/h DETAIL CODE TURNS/min. VOLTAGE Hp. m³/h DETAIL WEIGHT [Kg] CODE A [mm] B [mm] ØC mm] ØD [mm] E [mm] F [mm] WEIGHT [Kg] DETAIL DETAIL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only.
  9. 9. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment READ / RERAC READ/RERAC READ RERAC Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) - Safe Areas Classification: Group II - Category 2G 2D Feam Catalogue 03 - 9 Ex Radiators FLAMEPROOF ELECTRIC RADIATORS INDUSTRIAL ELECTRIC HEATERS On Request Accessories: • Different supply from standard • Protection degree IP40 (RERAC...) Mechanical characteristics RERAC Mechanical characteristics READ Control box marine grade copper free aluminium light alloy Heating unit stamped and welded steel sheets Control box painting epoxy powders grey RAL-9006 colour Heating unit painting epoxy powders grey RAL-7035 colour Box welded steel 8/10mm th. Front upper and inferior surfaces steel sheet 15/10mm th. with oblong holes Painting ivory RAL-1015 colour FLAME PROOF ELECTRIC RADIATORS - READ ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIC T3 Gb II 2 D Ex tb IIIC T200°C Db Ex d IIC T3 Gb Ex tb IIIC T200°C Db Ex d IIC T3 Gb Ex tb IIIC T200°C Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTECTION DEGREE IP65 IP65 IP65 CERTIFICATE REF. INERIS 04 ATEX 0076X POCC IT. ME92.B02924 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 FLAME PROOF ELECTRIC RADIATORS - READ ATEX 94/9/EC EXECUTION II 2 G Ex d IIC T4 AMBIENT TEMPERATURE -40°C ÷ +60°C PROTECTION DEGREE IP65 CERTIFICATE REF. CESI 03 ATEX 082X RULES OF COMPLIANCE EN 60079-0; EN 60079-1 INDUSTRIAL ELECTRIC HEATERS - RERAC CEI / IEC EXECUTION INDUSTRIAL WATERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP20 (RERAC-L) - IP44/IP55 (RERAC/RERAC-C) CERTIFICATE REF. - RULES OF COMPLIANCE CEI / EN 60598-1
  10. 10. YOUR PARTNER FOR SAFETY Since 1961 READ1000W 230V - 50/60Hz 1000 A READ2000W 230V - 50/60Hz 2000 A RERAC21000 230V - 50/60Hz 500 1000 B RERAC31500 230V - 50/60Hz 1000 1500 B RERAC42000 230V - 50/60Hz 1000 2000 B RERACC2500 230V - 50/60Hz 250 500 B RERACC2800 230V - 50/60Hz 550 800 B RERACC3750 230V - 50/60Hz 500 750 B RERACL1900 230V - 50/60Hz 900 - C RERACL21800 230V - 50/60Hz 900 1800 C READ1000W 640 510 600 675 165 39,00 A READ2000W 1140 1010 600 675 165 74,00 A RERAC21000 520 715 490 695 133 11,00 B RERAC31500 520 715 490 695 133 11,05 B RERAC42000 520 715 490 695 133 12,00 B RERACC2500 315 700 288 680 108 6,60 B RERACC2800 315 700 288 680 108 6,90 B RERACC3750 315 700 288 680 108 7,20 B RERACL1900 1060 395 1040 375 107 9,10 C RERACL21800 1060 395 1040 375 107 9,60 C READ/RERAC D A C B D E A C B A C D E B C A 10 - Feam Catalogue 03 Ex Radiators READ / RERAC Technical Features Reference Details Reference Details Reference Details CONSTRUCTION FEATURES: Electric heater, oil field, movable on pivoting wheels or to be fixed by special supports on the floor or to the wall. Two electric armoured resistances unit provided with incorporated thermal circuit breaker located inside one. Resistance thermal exchange: 2W/sqcm Control gear box containing a three positions change over swich: 0 – 50% - 100% power. Adjustable thermostat. Certified cable gland for a feeding armoured 2 Mt. cable 3x2.5sqmm Heating system is composed with a group of finned armoured electric resistance, electrically connected to have two heating levels (only RERAC...). CODE TENSION POWER [W] DETAIL CODE TENSION POWER LEVELS [W] DETAIL I II CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] DETAIL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only.
  11. 11. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment WEATHERPROOFCONTROLPANELS Framework And Panel 15-20/10 thik sheet steel with galvanic or sendzimir treatment Glass (On Request) tempered glass (5mm thickness) complete with silicon rubber gasket Screws stainless steel Feam Catalogue 03 - 11 Mechanical characteristics APPLICATIONS Installation: Safe area Classification: IP55 Weatherproof Control Panels Weatherproof Control Panels On Request Accessories: • Other degree protection level • Stainless steel AISI316L framework and interior panel Maximum Rating 600A Inslutating Voltage 690V Test Voltage 50Hz 2500V for 1 minute Frequency 50/60Hz Short Circuit Withstand Strenght On Plate Max 35 kA for 1 minute Distribution Bars Ipk=73,5 kA peak ELECTRICAL PANEL CEI / IEC EXECUTION INDUSTRIAL WATERPROOF INSTALLATION -40°C ÷ +70°C PROTECTION DEGREE IP55 CERTIFICATE REF. - RULES OF COMPLIANCE CEI EN 60439-1 (CEI 17-13/1) CEI EN 90529
  12. 12. YOUR PARTNER FOR SAFETY Since 1961 WEATHERPROOFCONTROLPANELS 12 - Feam Catalogue 03 Weatherproof Control Panels Reference Details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Weatherproof sheet steel or stainless steel 304/316 control panel, interchangeable plate version Safety Flexibility Interchangeability The control panel has been designed so that no live part can come into contact with the operator’s body even with the main door open, according to the degree of protection IP XX B of standard IEC 529. In case of breakdown the plates (the system’s main characteristic) can be easily replaced with new ones of the same type with a very simple operation. The plates can be prepared by FEAM, wired or already fitted and shipped to destination. The system is designed so that the standard type (circuit breakers) can be integrated with other types (contactors) with no need to adapt other (different) structures to the primary system to support the different types.

×