SlideShare a Scribd company logo
1 of 2
Download to read offline
HEATFAST - HF7000D
WINTER FROST PROTECTION KITS
www.heattracing.co.uk
HF7000D trace heating kits are the ideal solution to provide winter frost protection to pipework
exposed to low ambient temperatures. Kits are suitable for metallic & plastic pipes up to 100mm
diameter* and come complete with self-regulating trace heating cable, digital surface sensing
control thermostat and all necessary components & instructions to allow for easy installation.
Part Reference
HF7005D - 5m Frost Protection Kit
HF7010D - 10m Frost Protection Kit
HF7025D - 25m Frost Protection Kit
HF7050D - 50m Frost Protection Kit
HF7100D - 100m Frost Protection Kit
Kit Contents
HF1210 - Self Regulating Frost Protection Cable
HF9102 - Digital Surface Sensing Thermostat
HF9425 - Connection/Termination Kit
HF9501 - Glass Tape
HF9591 - Warning Labels
HF9550 - Mounting Brackets
• Voltage: Mains, 240v
• Quick & safe frost protection solution
• Self-regulating
• Suitable for install by DIY or trade
HEATFAST HF1210 Cable Specification
Colour Black
Overjacket Polyolefin
Maximum Exposure Temperature (Energised) 65°C
Bus wire diameter 1.23mm2
Power Output 10w/m
Voltage 230V
Braid Copper
Self-Regulating Cable – Operating Principle
Parallel bus wires apply voltage along the entire length of the heater cable. The conductive core
provides an infinite number of parallel conductive paths allowing the cable to be cut to length on
site.
The cables’ ability to be self-regulating derives from the properties of the conductive core material.
As the core temperature increases the number of conductive paths in the core decreases -
decreasing the heat output.
HEATFAST - HF7000D
WINTER FROST PROTECTION KITS
www.heattracing.co.uk
This occurs at every point along the length of the cable, adjusting power output to the varying
conditions along the pipe.
* Heat loss calculations are based on metallic pipes up to 100mm diameter, 25mm thermal
insulation, -10ºC minimum ambient temperature and 65ºC maximum pipe temperature. If you have
different requirements please contact T&D for advice.
To comply with British Standards, all trace heating kits should be wired with suitable MCB and 30mA
RCD protection. Contact T&D for advice.
40 Years Service Life – IEEE Performance Tested
Manufactured in accordance with IEEE515-2004 and IEEE515.1 Standard for the Testing, Design,
Installation and Maintenance of Electrical Resistance Heat Tracing for Commercial Applications.
The test uses accelerated thermal aging to estimate the life expectancy of a products construction
over a prolonged period of time. This test method results in a life expectancy in excess of 40 years at
a maximum maintenance temperature of 65 Degrees Celsius.
This testing includes:
* Dielectric * Water Resistance
* Elevated Temperature Exposure * Thermal Performance Benchmark
* Deformation * Impact
* Cold Bend * Flammability
* Verification of Rated Output * Verification of Start-Up Current
Over 500KM of HEATFAST trace heating cables have been installed to projects throughout the UK
including the Olympic Stadium & Wembley Stadium. You will not need to replace our system next
winter.
Contact Information
T&D (Gateshead) T&D (Bristol)
Gear House Units 9 & 10
Saltmeadows Road Birchills Trading Estate
Gateshead Emery Road
NE8 3AH Brislington
Bristol
BS4 5PF
Phone: 0191 490 1547 Phone: 0117 977 4647
Northernsales@thorneandderrick.co.uk Southernsales@thorneandderrick.co.uk

More Related Content

Viewers also liked (6)

Esp adspend forecasts september 2013 executive summary
Esp adspend forecasts september 2013 executive summaryEsp adspend forecasts september 2013 executive summary
Esp adspend forecasts september 2013 executive summary
 
OpenAIRE at Nordbib 12 Conference
OpenAIRE at Nordbib 12 ConferenceOpenAIRE at Nordbib 12 Conference
OpenAIRE at Nordbib 12 Conference
 
Multiplication 1
Multiplication   1Multiplication   1
Multiplication 1
 
Methods in teaching
Methods in teachingMethods in teaching
Methods in teaching
 
Estimating the potential for mode shift based on price and incentives
Estimating the potential for mode shift based on price and incentivesEstimating the potential for mode shift based on price and incentives
Estimating the potential for mode shift based on price and incentives
 
Herramientas para tutorizar_investigación_1ª_edic_16-18_sept_2013
Herramientas para tutorizar_investigación_1ª_edic_16-18_sept_2013Herramientas para tutorizar_investigación_1ª_edic_16-18_sept_2013
Herramientas para tutorizar_investigación_1ª_edic_16-18_sept_2013
 

More from Thorne & Derrick UK

More from Thorne & Derrick UK (20)

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
 
Dart Valley Systems Catalogue
Dart Valley Systems CatalogueDart Valley Systems Catalogue
Dart Valley Systems Catalogue
 
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration Instruments
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - Catalogue
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection Cable
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate Brochure
 

Frost Protection For Boiler Condensate Heatfast HF7010D Trace Heating Kit - Spec Sheet

  • 1. HEATFAST - HF7000D WINTER FROST PROTECTION KITS www.heattracing.co.uk HF7000D trace heating kits are the ideal solution to provide winter frost protection to pipework exposed to low ambient temperatures. Kits are suitable for metallic & plastic pipes up to 100mm diameter* and come complete with self-regulating trace heating cable, digital surface sensing control thermostat and all necessary components & instructions to allow for easy installation. Part Reference HF7005D - 5m Frost Protection Kit HF7010D - 10m Frost Protection Kit HF7025D - 25m Frost Protection Kit HF7050D - 50m Frost Protection Kit HF7100D - 100m Frost Protection Kit Kit Contents HF1210 - Self Regulating Frost Protection Cable HF9102 - Digital Surface Sensing Thermostat HF9425 - Connection/Termination Kit HF9501 - Glass Tape HF9591 - Warning Labels HF9550 - Mounting Brackets • Voltage: Mains, 240v • Quick & safe frost protection solution • Self-regulating • Suitable for install by DIY or trade HEATFAST HF1210 Cable Specification Colour Black Overjacket Polyolefin Maximum Exposure Temperature (Energised) 65°C Bus wire diameter 1.23mm2 Power Output 10w/m Voltage 230V Braid Copper Self-Regulating Cable – Operating Principle Parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths allowing the cable to be cut to length on site. The cables’ ability to be self-regulating derives from the properties of the conductive core material. As the core temperature increases the number of conductive paths in the core decreases - decreasing the heat output.
  • 2. HEATFAST - HF7000D WINTER FROST PROTECTION KITS www.heattracing.co.uk This occurs at every point along the length of the cable, adjusting power output to the varying conditions along the pipe. * Heat loss calculations are based on metallic pipes up to 100mm diameter, 25mm thermal insulation, -10ºC minimum ambient temperature and 65ºC maximum pipe temperature. If you have different requirements please contact T&D for advice. To comply with British Standards, all trace heating kits should be wired with suitable MCB and 30mA RCD protection. Contact T&D for advice. 40 Years Service Life – IEEE Performance Tested Manufactured in accordance with IEEE515-2004 and IEEE515.1 Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Heat Tracing for Commercial Applications. The test uses accelerated thermal aging to estimate the life expectancy of a products construction over a prolonged period of time. This test method results in a life expectancy in excess of 40 years at a maximum maintenance temperature of 65 Degrees Celsius. This testing includes: * Dielectric * Water Resistance * Elevated Temperature Exposure * Thermal Performance Benchmark * Deformation * Impact * Cold Bend * Flammability * Verification of Rated Output * Verification of Start-Up Current Over 500KM of HEATFAST trace heating cables have been installed to projects throughout the UK including the Olympic Stadium & Wembley Stadium. You will not need to replace our system next winter. Contact Information T&D (Gateshead) T&D (Bristol) Gear House Units 9 & 10 Saltmeadows Road Birchills Trading Estate Gateshead Emery Road NE8 3AH Brislington Bristol BS4 5PF Phone: 0191 490 1547 Phone: 0117 977 4647 Northernsales@thorneandderrick.co.uk Southernsales@thorneandderrick.co.uk