APHACIC IOL

APHAKIC INTRAOCULAR LENS
BY
DR- ALSHYMAA MOUSTAFA
OPHTHALMOLOGY SPECIALIST
INTRAOCULAR LENS (IOL )
 Several different factors affect choosing an IOL for cataract surgery.
 Materials and design should result in a low degree of postoperative inflammation by
being as inert as possible and have a good track record concerning long-term
complications such as posterior capsule opacification (PCO).
 IOL materials should also be easy to handle concerning folding and implantation.
 In special cases, such as those with incomplete capsule support, high myopia, or with a
history of uveitis, the IOL choice may differ from the usual one.
 Additionally, in eyes with a cornea that either has astigmatism and/or
spherical aberrations (SA), special IOLs may be indicated.
 Patients who want to be less dependent on spectacles for near work or
intermediate distance vision after surgery may be considered for
multifocal IOL designs. Use of these lenses should be dissuaded in the
presence of corneal or macular pathology.
 Patient’s should be thoroughly counseled regarding both the benefits
and drawbacks of multifocal lenses (eg. glare, haloes, decreased
contrast sensitivity) prior to their insertion.
IOL MATERIALS
 The earliest IOLs were made of polymethylmethacrylate (PMMA), the
plastic that IOL inventor Harold Ridley had noticed to be inert in eyes of
World War II aviators struck by flying plastic during combat.
 With the introduction of phacoemulsification and the possibility to
remove the cataract through smaller incisions, foldable materials were
developed for IOLs such as hydrophobic acrylic, hydrophilic acrylic (or
hydrogel), and hydrophobic silicone, the three main material groups in
use today.
• POLYMETHYLMETHACRYLATE (PMMA):
 PMMA today plays little role mainly because of large wound size, it still plays an
important role in extracapsular cataract extraction (ECCE)
 PMMA IOLs with a sharp optic edge have been shown to result in relatively low (PCO)
rates, and heparin-surface modified PMMA IOLs have been used in uveitis patients.
 Currently, PMMA is still used for sulcus-placed IOLs due to their overall rigidity, which
results in good centration and resistance to tilt, as well as in sulcus-sutured IOLs for
the same reasons.
 Anterior chamber IOLs as well as iris-fixated IOLs are also made of PMMA and known
to be very inert concerning the uveal inflammatory reaction.
 PMMA lenses have a long track record of maintaining clarity with no glistenings or
deposits.
PC IOL Sulcus fixated IOL
AC IOL
 Currently the most commonly used material
group, these polymers of acrylate are
foldable under room temperature. The
materials have very low water content, a
high refractive index, and usually a high
memory, which also makes the material
suitable for the haptics of a monobloc open-
loop IOL.
 This group of material unfolds in a
controlled fashion and has been shown to
have a good uveal and excellent capsular
biocompatibility .
• FOLDABLE HYDROPHOBIC ACRYLIC :
 The drawbacks of this material group has been intralenticular changes. Small water inclusions in
the optic material called glistenings can occur in hydrophobic materials. Over time, the glistenings
can increase. Although controversial, evidence to this date does not indicate an effect on visual
function.
 The other drawback has been dysphotopsias reported with this high refractive index material.
The most common positive dysphotopsia was edge glare, which was due to internal reflections at
the rectangular edge of the Acrys of IOL under mesopic conditions with a large pupil, typically
induced by a light source from the side and reported as a peripheral arc of light by patients.
 As a result of changes in optic geometry, these dysphotopsias have been reduced significantly
with newer hydrophobic acrylic models.
Glistening of
IOL
• HYDROPHILIC ACRYLIC :
 Hydrophilic acrylic is a quite heterogeneous material group and has a high
water content.
 These lenses are cut in the dehydrated state and then hydrated and stored in
solution. The water content between IOLs varies widely and can be as high as
38%.
 The hydrophilic acrylic lenses are more prone to develop PCO than hydrophobic
acrylic lenses or silicone lenses. This may be due to the high water content
being more “inviting” to lens epithelial cells (LEC) ingrowth or the fact that the
optic edge of IOLs in this group is never as sharp as with the hydrophobic
materials, therefore inducing a less sharp bend of the capsule at the edge and
being a less effective barrier to regenerating LECs.
IOL calcification ( hydrophillic):
A,B: on the surface of IOL.
C : within the IOL substance.
D: on the posterior surface of silicon IOL
.
• SILICONE :
 Silicone was the first material available for foldable IOLs.
In the past decade, we have been seeing a continuous
decline in the use of silicone IOLs. While silicone is a very
good IOL material, especially concerning its PCO blocking
effect, it cannot be used for a monobloc open-loop lens.
 This lens design is the preferred choice for use with
preloaded injectors that allow implantation through
incisions smaller than 2.8 mm, which appears to be the
current trend. When using an injector for small incisions,
there is a risk of tearing of the optic at the optic-haptic
junction or kinking of the haptics during injection with
multipiece open-loop IOLs.
 All IOL materials used today include ultraviolet (UV) light-
blocking chromophores to filter the UV light. The blue light was
considered harmful due to short wavelength, high energy light
causing retinal damage by inducing more oxidative stress at
the retinal level. Some manufacturers have introduced yellow-
tinted IOLs to filter the short wavelength light.
 A yellow lens has two potential drawbacks: one is a reduction
in color contrast sensitivity, especially under mesopic conditions,
and another is that the melatonin production in the brain may
be altered, causing a change in the circadian rhythms that are
steered by blue light levels in the eye.
• LIGHT FILTERING :
REVIEW
IOL
DESIGN
Design options for IOLs currently are manifold:
 Multipiece or monobloc
 Plate or open-loop style
 Angulated or planar haptics
 Special haptics for certain indications such as sulcus, anterior chamber angle or iris
fixation
 Optic shape and edge design
 Optic geometry for certain indications such as toric, aspheric or multifocal IOLs
• Open Loop
• Multipiece • Singlepiece
• Monobloc
• Haptic angulation
• Special Designs
Rt and Lt eyes of same
patient 3years after phaco
surgery showing :
Rt: Multipiece Acrysoft IOL.
Lt: Single piece Acrysoft
IOL.
Note : eht
ssel
OCP
ni
esac
esac
fo
eceipitluM
LOI
.
• Edge Design
The difference between the
Sharp edge and Round edge.
Note: The Round edge ( lower
photo ) has a higher incidence of
PCO, while The Sharp edge leads to
a significant reduction of PCO by
inducing a discontinuous bend at the
posterior capsule.
PCO in A Round Edge :
Rt photo 1 year after phaco
surgery.
Lt one 3 years after phaco
surgery.
Note Incresing PCO with time.
PCO in A sharp edge :
Rt photo 1 year after phaco
surgery.
Lt one 3 years after phaco surgery
.
Note stable clear posterior capsule
with time.
 Sharp-edge IOL designs cause the light rays that are refracted through the peripheral
IOL to be more intense on the peripheral retina.
 Round-edge IOL designs disperse the rays of light over a larger surface area of the
retina, leading to less glare. However.
 The half-rounded edge profile of some newly developed IOLs with a round anterior
and sharp posterior optic edge seems to avoid this disturbing side effect.
 Most IOLs on the market have a
symmetrically biconvex optic, meaning that
the radius of curvature of the front and back
surface are identical.
 There are asymmetrically biconvex optic
lenses, This causes a slight shift of the
principal optical plane of the IOL and also
implies that the lens should not be implanted
front-to-back (reversed) in the eye, apart
from the angulation of the haptics being
backward as well. In a symmetrically
biconvex lens with no angulation, the IOL
could be implanted front-to-back (reversed)
without a change in optical power.
• Optic Geometry
Bioconvexity Optical Zone
 Most IOLs have a full-size effective
optical zone of 6 mm in the main
range of IOL powers.
 Therefore, the higher powered IOLs
will have a thicker optic than the
lower powers.
 This has the advantage of a full optic
zone but can make folding of the IOL
(or injecting with an injector) variable
depending on IOL power.
 Some IOLs keep a constant center
thickness of the optic and vary the
effective optical zone, thereby varying
the curvature of the optic and
therefore, optic power.
APHACIC IOL
• SPECIAL OPTICS
Aspherical Intraocular Lenses
 The cornea typically induces a degree of
positive spherical aberration (SA).
 The aim is to increase contrast sensitivity
under mesopic conditions where the pupil is
dilated.
 The aspheric IOLs have little to no effect when
the pupil is small.
 Although it decreases contrast sensitivity, some
degree of positive spherical aberration can
increase depth-of-field of vision.
Toric Intraocular Lenses
 An effective and quite predictable method
of neutralizing corneal astigmatism is the
use of toric IOLs.
 The steep axis of the eye needs to be
marked in the sitting position before
surgery since the eye will undergo some
cyclotorsion in the supine position. The
mean cyclotorsion was reported to be 2
degrees up to 10 degrees.
Multifocal Intraocular Lenses
 MIOL are designed to overcome the
postoperative lack of accommodation by
dividing the incoming light on two or more focal
points.
 One of these is used for distance vision, the
other for near or intermediate vision. These IOLs
have shown to reduce the need for spectacle
correction in daily life.
 However, good refractive outcome and low
residual astigmatism after surgery are key to
success. Therefore, meticulous biometry and
power calculation are needed.
THANKS
1 von 30

Más contenido relacionado

Was ist angesagt?(20)

By pd aphakia & pseudophakiaBy pd aphakia & pseudophakia
By pd aphakia & pseudophakia
Pushkar Dhir15.2K views
AphakiaAphakia
Aphakia
ankita mahapatra8.6K views
Refractive errorRefractive error
Refractive error
Optometry fans2.8K views
Work-up of Refractive surgeriesWork-up of Refractive surgeries
Work-up of Refractive surgeries
ShreyaGupta3231.6K views
Behind The ScenesBehind The Scenes
Behind The Scenes
bpark279502.4K views
Rosek2 part1Rosek2 part1
Rosek2 part1
Hossein Mirzaie3K views
Error of RefractionError of Refraction
Error of Refraction
Prof Vijayraddi7.7K views
Keratoconus refraction Keratoconus refraction
Keratoconus refraction
Mohamed Elkadim295 views
fitting RGP lensesfitting RGP lenses
fitting RGP lenses
Hossein Mirzaie94.5K views
Newer IOLsNewer IOLs
Newer IOLs
Dr. Ajay Kumar Singh27.7K views
Refractive errorRefractive error
Refractive error
OM VERMA134.5K views
Phakic IOLPhakic IOL
Phakic IOL
Gauree Gattani8.1K views
Phakic Intraocular implants in 2017Phakic Intraocular implants in 2017
Phakic Intraocular implants in 2017
Bijan Farpour357 views
Intra ocular lensIntra ocular lens
Intra ocular lens
Vishnu Narayanan42.5K views
Cataract  - Easy PPT for Nursing StudentsCataract  - Easy PPT for Nursing Students
Cataract - Easy PPT for Nursing Students
Swatilekha Das54.1K views
Aphakia  by SURAJ CHHETRIAphakia  by SURAJ CHHETRI
Aphakia by SURAJ CHHETRI
Suraj Chhetri30K views

Similar a APHACIC IOL(20)

Achieving Excellence in Cataract SurgeryAchieving Excellence in Cataract Surgery
Achieving Excellence in Cataract Surgery
VAISHNAVIMUMMIDI118 views
Intra Oular LensesIntra Oular Lenses
Intra Oular Lenses
slidenka6.6K views
RECENT ADVANCES IN INTRAOCULAR LENSRECENT ADVANCES IN INTRAOCULAR LENS
RECENT ADVANCES IN INTRAOCULAR LENS
Dr Laltanpuia Chhangte18.3K views
Intra Ocular lensIntra Ocular lens
Intra Ocular lens
dipusarkar2507 views
Phakic iol pptPhakic iol ppt
Phakic iol ppt
DrArino John3.4K views
Types of iolTypes of iol
Types of iol
Rohit Rao27.9K views
Implantable collamer lens(ICL)Implantable collamer lens(ICL)
Implantable collamer lens(ICL)
Samuel Ponraj10.9K views
Phakic Intraocular lensPhakic Intraocular lens
Phakic Intraocular lens
rumi das3.3K views
Step by step IRIS clipStep by step IRIS clip
Step by step IRIS clip
Laxmi Eye Institute11.6K views
Phakic intraocular lens Phakic intraocular lens
Phakic intraocular lens
sreedhanya 977 views
Multifocal iolsMultifocal iols
Multifocal iols
SSSIHMS-PG15.9K views
The Right ContactThe Right Contact
The Right Contact
therightcontact1.6K views
The Right ContactThe Right Contact
The Right Contact
therightcontact511 views

Más de Sheim Elteb

CASE REVIEW.pptxCASE REVIEW.pptx
CASE REVIEW.pptxSheim Elteb
8 views41 Folien
VF in glaucoma.pptxVF in glaucoma.pptx
VF in glaucoma.pptxSheim Elteb
38 views60 Folien
EUA-WPS Office.pptxEUA-WPS Office.pptx
EUA-WPS Office.pptxSheim Elteb
13 views17 Folien
POAG.pptxPOAG.pptx
POAG.pptxSheim Elteb
23 views36 Folien
ExotropiaExotropia
ExotropiaSheim Elteb
278 views14 Folien

Más de Sheim Elteb(20)

CASE REVIEW.pptxCASE REVIEW.pptx
CASE REVIEW.pptx
Sheim Elteb8 views
VF in glaucoma.pptxVF in glaucoma.pptx
VF in glaucoma.pptx
Sheim Elteb38 views
EUA-WPS Office.pptxEUA-WPS Office.pptx
EUA-WPS Office.pptx
Sheim Elteb13 views
GLAUCOMA MEDICATION.pptxGLAUCOMA MEDICATION.pptx
GLAUCOMA MEDICATION.pptx
Sheim Elteb19 views
POAG.pptxPOAG.pptx
POAG.pptx
Sheim Elteb23 views
ExotropiaExotropia
Exotropia
Sheim Elteb278 views
Incomitant strabismusIncomitant strabismus
Incomitant strabismus
Sheim Elteb560 views
INDIRECT OPHTHALOMOSCOPEINDIRECT OPHTHALOMOSCOPE
INDIRECT OPHTHALOMOSCOPE
Sheim Elteb76 views
KeratometerKeratometer
Keratometer
Sheim Elteb674 views
Non  accommodative etNon  accommodative et
Non accommodative et
Sheim Elteb120 views
NystagmusNystagmus
Nystagmus
Sheim Elteb669 views
Pupil examinationPupil examination
Pupil examination
Sheim Elteb1K views
RetinoscopyRetinoscopy
Retinoscopy
Sheim Elteb362 views
UWSUWS
UWS
Sheim Elteb65 views
Yag post capsulotomyYag post capsulotomy
Yag post capsulotomy
Sheim Elteb553 views
Et casesEt cases
Et cases
Sheim Elteb16 views
EOM testEOM test
EOM test
Sheim Elteb88 views
Early onset etEarly onset et
Early onset et
Sheim Elteb89 views
Dry eyeDry eye
Dry eye
Sheim Elteb79 views
Direct opthalmoscopeDirect opthalmoscope
Direct opthalmoscope
Sheim Elteb144 views

Último(20)

Dance KS5 BreakdownDance KS5 Breakdown
Dance KS5 Breakdown
WestHatch52 views
STERILITY TEST.pptxSTERILITY TEST.pptx
STERILITY TEST.pptx
Anupkumar Sharma102 views
Chemistry of sex hormones.pptxChemistry of sex hormones.pptx
Chemistry of sex hormones.pptx
RAJ K. MAURYA97 views
Psychology KS4Psychology KS4
Psychology KS4
WestHatch52 views
discussion post.pdfdiscussion post.pdf
discussion post.pdf
jessemercerail70 views
Lecture: Open InnovationLecture: Open Innovation
Lecture: Open Innovation
Michal Hron82 views
CWP_23995_2013_17_11_2023_FINAL_ORDER.pdfCWP_23995_2013_17_11_2023_FINAL_ORDER.pdf
CWP_23995_2013_17_11_2023_FINAL_ORDER.pdf
SukhwinderSingh895865467 views
AI Tools for Business and StartupsAI Tools for Business and Startups
AI Tools for Business and Startups
Svetlin Nakov57 views
BYSC infopack.pdfBYSC infopack.pdf
BYSC infopack.pdf
Fundacja Rozwoju Społeczeństwa Przedsiębiorczego144 views
Streaming Quiz 2023.pdfStreaming Quiz 2023.pdf
Streaming Quiz 2023.pdf
Quiz Club NITW87 views
Plastic waste.pdfPlastic waste.pdf
Plastic waste.pdf
alqaseedae81 views
Sociology KS5Sociology KS5
Sociology KS5
WestHatch50 views
ACTIVITY BOOK key water sports.pptxACTIVITY BOOK key water sports.pptx
ACTIVITY BOOK key water sports.pptx
Mar Caston Palacio132 views
Industry4wrd.pptxIndustry4wrd.pptx
Industry4wrd.pptx
BC Chew153 views
Scope of Biochemistry.pptxScope of Biochemistry.pptx
Scope of Biochemistry.pptx
shoba shoba110 views
Narration lesson plan.docxNarration lesson plan.docx
Narration lesson plan.docx
TARIQ KHAN90 views

APHACIC IOL

  • 1. APHAKIC INTRAOCULAR LENS BY DR- ALSHYMAA MOUSTAFA OPHTHALMOLOGY SPECIALIST
  • 2. INTRAOCULAR LENS (IOL )  Several different factors affect choosing an IOL for cataract surgery.  Materials and design should result in a low degree of postoperative inflammation by being as inert as possible and have a good track record concerning long-term complications such as posterior capsule opacification (PCO).  IOL materials should also be easy to handle concerning folding and implantation.  In special cases, such as those with incomplete capsule support, high myopia, or with a history of uveitis, the IOL choice may differ from the usual one.
  • 3.  Additionally, in eyes with a cornea that either has astigmatism and/or spherical aberrations (SA), special IOLs may be indicated.  Patients who want to be less dependent on spectacles for near work or intermediate distance vision after surgery may be considered for multifocal IOL designs. Use of these lenses should be dissuaded in the presence of corneal or macular pathology.  Patient’s should be thoroughly counseled regarding both the benefits and drawbacks of multifocal lenses (eg. glare, haloes, decreased contrast sensitivity) prior to their insertion.
  • 4. IOL MATERIALS  The earliest IOLs were made of polymethylmethacrylate (PMMA), the plastic that IOL inventor Harold Ridley had noticed to be inert in eyes of World War II aviators struck by flying plastic during combat.  With the introduction of phacoemulsification and the possibility to remove the cataract through smaller incisions, foldable materials were developed for IOLs such as hydrophobic acrylic, hydrophilic acrylic (or hydrogel), and hydrophobic silicone, the three main material groups in use today.
  • 5. • POLYMETHYLMETHACRYLATE (PMMA):  PMMA today plays little role mainly because of large wound size, it still plays an important role in extracapsular cataract extraction (ECCE)  PMMA IOLs with a sharp optic edge have been shown to result in relatively low (PCO) rates, and heparin-surface modified PMMA IOLs have been used in uveitis patients.  Currently, PMMA is still used for sulcus-placed IOLs due to their overall rigidity, which results in good centration and resistance to tilt, as well as in sulcus-sutured IOLs for the same reasons.  Anterior chamber IOLs as well as iris-fixated IOLs are also made of PMMA and known to be very inert concerning the uveal inflammatory reaction.  PMMA lenses have a long track record of maintaining clarity with no glistenings or deposits.
  • 6. PC IOL Sulcus fixated IOL AC IOL
  • 7.  Currently the most commonly used material group, these polymers of acrylate are foldable under room temperature. The materials have very low water content, a high refractive index, and usually a high memory, which also makes the material suitable for the haptics of a monobloc open- loop IOL.  This group of material unfolds in a controlled fashion and has been shown to have a good uveal and excellent capsular biocompatibility . • FOLDABLE HYDROPHOBIC ACRYLIC :
  • 8.  The drawbacks of this material group has been intralenticular changes. Small water inclusions in the optic material called glistenings can occur in hydrophobic materials. Over time, the glistenings can increase. Although controversial, evidence to this date does not indicate an effect on visual function.  The other drawback has been dysphotopsias reported with this high refractive index material. The most common positive dysphotopsia was edge glare, which was due to internal reflections at the rectangular edge of the Acrys of IOL under mesopic conditions with a large pupil, typically induced by a light source from the side and reported as a peripheral arc of light by patients.  As a result of changes in optic geometry, these dysphotopsias have been reduced significantly with newer hydrophobic acrylic models.
  • 10. • HYDROPHILIC ACRYLIC :  Hydrophilic acrylic is a quite heterogeneous material group and has a high water content.  These lenses are cut in the dehydrated state and then hydrated and stored in solution. The water content between IOLs varies widely and can be as high as 38%.  The hydrophilic acrylic lenses are more prone to develop PCO than hydrophobic acrylic lenses or silicone lenses. This may be due to the high water content being more “inviting” to lens epithelial cells (LEC) ingrowth or the fact that the optic edge of IOLs in this group is never as sharp as with the hydrophobic materials, therefore inducing a less sharp bend of the capsule at the edge and being a less effective barrier to regenerating LECs.
  • 11. IOL calcification ( hydrophillic): A,B: on the surface of IOL. C : within the IOL substance. D: on the posterior surface of silicon IOL .
  • 12. • SILICONE :  Silicone was the first material available for foldable IOLs. In the past decade, we have been seeing a continuous decline in the use of silicone IOLs. While silicone is a very good IOL material, especially concerning its PCO blocking effect, it cannot be used for a monobloc open-loop lens.  This lens design is the preferred choice for use with preloaded injectors that allow implantation through incisions smaller than 2.8 mm, which appears to be the current trend. When using an injector for small incisions, there is a risk of tearing of the optic at the optic-haptic junction or kinking of the haptics during injection with multipiece open-loop IOLs.
  • 13.  All IOL materials used today include ultraviolet (UV) light- blocking chromophores to filter the UV light. The blue light was considered harmful due to short wavelength, high energy light causing retinal damage by inducing more oxidative stress at the retinal level. Some manufacturers have introduced yellow- tinted IOLs to filter the short wavelength light.  A yellow lens has two potential drawbacks: one is a reduction in color contrast sensitivity, especially under mesopic conditions, and another is that the melatonin production in the brain may be altered, causing a change in the circadian rhythms that are steered by blue light levels in the eye. • LIGHT FILTERING :
  • 15. IOL DESIGN Design options for IOLs currently are manifold:  Multipiece or monobloc  Plate or open-loop style  Angulated or planar haptics  Special haptics for certain indications such as sulcus, anterior chamber angle or iris fixation  Optic shape and edge design  Optic geometry for certain indications such as toric, aspheric or multifocal IOLs
  • 16. • Open Loop • Multipiece • Singlepiece
  • 20. Rt and Lt eyes of same patient 3years after phaco surgery showing : Rt: Multipiece Acrysoft IOL. Lt: Single piece Acrysoft IOL. Note : eht ssel OCP ni esac esac fo eceipitluM LOI .
  • 21. • Edge Design The difference between the Sharp edge and Round edge. Note: The Round edge ( lower photo ) has a higher incidence of PCO, while The Sharp edge leads to a significant reduction of PCO by inducing a discontinuous bend at the posterior capsule.
  • 22. PCO in A Round Edge : Rt photo 1 year after phaco surgery. Lt one 3 years after phaco surgery. Note Incresing PCO with time.
  • 23. PCO in A sharp edge : Rt photo 1 year after phaco surgery. Lt one 3 years after phaco surgery . Note stable clear posterior capsule with time.
  • 24.  Sharp-edge IOL designs cause the light rays that are refracted through the peripheral IOL to be more intense on the peripheral retina.  Round-edge IOL designs disperse the rays of light over a larger surface area of the retina, leading to less glare. However.  The half-rounded edge profile of some newly developed IOLs with a round anterior and sharp posterior optic edge seems to avoid this disturbing side effect.
  • 25.  Most IOLs on the market have a symmetrically biconvex optic, meaning that the radius of curvature of the front and back surface are identical.  There are asymmetrically biconvex optic lenses, This causes a slight shift of the principal optical plane of the IOL and also implies that the lens should not be implanted front-to-back (reversed) in the eye, apart from the angulation of the haptics being backward as well. In a symmetrically biconvex lens with no angulation, the IOL could be implanted front-to-back (reversed) without a change in optical power. • Optic Geometry Bioconvexity Optical Zone  Most IOLs have a full-size effective optical zone of 6 mm in the main range of IOL powers.  Therefore, the higher powered IOLs will have a thicker optic than the lower powers.  This has the advantage of a full optic zone but can make folding of the IOL (or injecting with an injector) variable depending on IOL power.  Some IOLs keep a constant center thickness of the optic and vary the effective optical zone, thereby varying the curvature of the optic and therefore, optic power.
  • 27. • SPECIAL OPTICS Aspherical Intraocular Lenses  The cornea typically induces a degree of positive spherical aberration (SA).  The aim is to increase contrast sensitivity under mesopic conditions where the pupil is dilated.  The aspheric IOLs have little to no effect when the pupil is small.  Although it decreases contrast sensitivity, some degree of positive spherical aberration can increase depth-of-field of vision.
  • 28. Toric Intraocular Lenses  An effective and quite predictable method of neutralizing corneal astigmatism is the use of toric IOLs.  The steep axis of the eye needs to be marked in the sitting position before surgery since the eye will undergo some cyclotorsion in the supine position. The mean cyclotorsion was reported to be 2 degrees up to 10 degrees.
  • 29. Multifocal Intraocular Lenses  MIOL are designed to overcome the postoperative lack of accommodation by dividing the incoming light on two or more focal points.  One of these is used for distance vision, the other for near or intermediate vision. These IOLs have shown to reduce the need for spectacle correction in daily life.  However, good refractive outcome and low residual astigmatism after surgery are key to success. Therefore, meticulous biometry and power calculation are needed.