SlideShare a Scribd company logo
1 of 9
University of Sulaimani
College of Engineering
Civil Engineering Department
(Soil Mechanics Lab)
Name of the Test: Standard Proctor Compaction Test
Test No. :
Students Name:
1- Raz Azad Abdullah
2- Zhyar Abu-Bakr
3- Rawezh Saady
Group & Sub-Group: A1-A6
Date of the Test:
1
Introduction:
Compaction is a method of mechanically increasing the density of soil,
and it’s especially valuable in construction applications. If this process is
not performed properly, soil settlement can occur, resulting in
unnecessary maintenance costs or failure of the pavement or structure.
For construction of highways, airports, and other structures, it is often
necessary to compact soil to improve its strength. Proctor (1933)
developed a laboratory compaction test procedure to determine the
maximum dry unit weight of compaction of soils, which can be used for
specification of field compaction. This test is referred to as the Standard
Proctor Compaction Test. It is based on compaction of soil fraction
passing No. 4 U.S. sieve.
Purpose:
The testing first determines the maximum density achievable for the soil
and uses it as a reference for field testing. It also is effective for testing
the effects of moisture on the soil's density.
There are a variety of different benefits to soil compaction, including:
prevention of soil settlement and frost damage, increased ground
stability, reduced hydraulic conductivity and mitigating undesirable
settlement of structures, such as paved roads, foundations and piping.
2
Equipment:
 Compaction mold
 No.4 U.S. sieve
 Standard Proctor hammer (5.5lb)(24.5N)
 Balance sensitive up to 0.01 lb
 Balance sensitive up to 0.1 g
 Large flat pan
 Jack
 Steel straight edge
 Moisture cans
 Drying oven
 Plastic squeeze bottle with water
3
Procedure:
1. Obtain about 10 lb (4.5 kg) of air-dry soil on which the compaction test is to be
conducted. Break all the soil lumps.
2. Sieve the soil on a No.4 U.S. sieve. Collect all of the minus-4 material in a large pan.
This should be about 6lb (2.7 kg) or more.
3. Add enough water to the minus-4 material and mix it in thoroughly to bring the
moisture content up to about ~.
4. Determine the weight of the Proctor mold + base plate (not the extension), WI' (lb).
5. Now attach the extension to the top of the mold.
6. 'Pour the moist soil into the mold in three equal layers. Each layer should be
compacted uniformly by the standard Proctor hammer 25 times before the next layer of
loose soil is poured into the mold.
7. Remove the top attachment from the mold. Be careful not to break off any of the
compacted soil inside the mold while removing the top attachment.
8. Using a straight edge, trim the excess soil above the mold (Fig. 12-3). Now the top of
the compacted soil will be even with the top of the mold.
9. Determine the weight of the mold + base plate + compacted moist soil in the mold, W2
(lb).
10. Remove the base plate from the mold. Using a jack, extrude the compacted soil
cylinder from the mold.
11. Take a weight of can (g).
12. From the moist soil extruded in Step 10, collect a moisture sample in the moisture can
(Step II) and determine the mass of the can + moist soil, (g).
13. Place the moisture can with the moist soil in the oven to dry to a constant weight.
14. Break the rest of the compacted soil (to No.4 size) by hand and mix it with the
leftover moist soil in the pan. Add more water and mix it to raise the moisture content by
about 2%.
4
Calculation:
γ = moist unit weight =
w2−w1
volume of mold
γdry=Dry unit weight =
γ
1+
w%
100
%(w)=
weight of moist
dry weight of soil
× 100 =
w(can+wet soil)−w(can+dry soil)
w(can+dry soil)−w(can)
× 100
γ zero air void =
γ water
w%
100
+
1
Gs
Where:- w1=weight of mold+ base plate.
w2=weight of mold+ base plate+ compacted moist soil in the mold.
w%= moisture content (M.C).
Volume of mold =
π D2
4
× H =
π 9.982
4
× 12.75 = 997.381 cm
1) Can #35:
(γ) Moist unit weight =
6412−4626
997.381
= 1.790 g/cm3
𝑀. 𝐶 =
116−113.5
113.5−74.08
× 100 = 6.342%
𝛾𝑑𝑟𝑦 =
1.790
1+
6.342
100
= 1.528 g/cm3
At same M.C:
γ zero air void (γ zav) =
1
6.342
100
+
1
2.7
= 2.305 g/cm3
2) Can #31:
(γ) Moist unit weight =
6558−4626
997.381
= 1.937g/cm3
M. C =
128−122.26
122.26−72.99
× 100 = 11.650%
5
γdry =
1.937
1+
11.650
100
= 1.734g/cm3
At same M.C:
γ zero air void (γ zav) =
1
11.650
100
+
1
2.7
= 2.054g/cm3
3) Can#14:
(γ) Moist unit weight =
6656−4626
997.381
=2.035g/cm3
M. C =
126−117.97
117.97−76.45
× 100 = 19.34%
γdry =
2.034
1+
19.34
100
= 1.704g/cm3
At same M.C:
γ zero air void (γ zav) =
1
19.340
100
+
1
2.7
= 1.773 g/cm3
4) Can#17:
(γ) Moist unit weight =
6600−4626
997.381
= 1.979g/cm3
M. C =
114−105.63
105.63−74.91
× 100 = 27.246%
γdry =
1.979
1+
27.246
100
= 1.555 g/cm3
At same M.C: γ zero air void (γ zav) =
1
27.246
100
+
1
2.7
= 1.555 g/cm3
6
Table of Results:
O.M.C=13.7% (from the graph)
Maximum dry unit weight = 1.74 g/cm3 (from the graph)
Test No. Wt. of Mold (g) Wt.of (wet soil+ mold)g Wet unit weight (g/cm3)
1 4626 6412 1.790
2 4626 6558 1.937
3 4626 6656 2.035
4 4626 6600 1.979
Can
No.
Wt. Of
container(g)
Wt. Of (wet
soil+cont.)(g)
Wt. Of (Dry
soil+cont.)(g)
W.C (%)
Dry Unit
weight
(g/cm3)
Max.theorotical
dry unit weight
(g/cm3)
γ (zav.)
(g/cm3)
35 74.08 116 113.5 6.341 1.681 2.232 2.305
31 72.99 128 122.26 11.65 1.734 1.995 2.054
14 76.45 126 117.97 19.34 1.704 1.73 1.773
17 74.91 114 105.63 27.246 1.554 1.523 1.555
7
8
Discussion& Conclusion:
The Proctor compaction test is a laboratory method of experimentally determining
the optimal moisture content at which a given soil type will become most dense
and achieve its maximum dry density., compaction of soil increases the shear
strength of the soil, increase the bearing capacity, also reduces erosion and it will
give the soil more stability, and reduces voids between the particles so that it
makes the soil more difficult for water to flow through soil.
In this soil sample, from the graph the soil has a maximum dry unit weight of (1.74
g/c𝑚3
) with the optimum moisture content of (13.7%), but after calculation of
zero-air-void curve and plotting on the graph we saw that the last point of the real
soil curve intersects with the zero-air-void curve, which it means the soil sample
became void less and goes beyond the theoretical curve which is not acceptable.
Many errors could have occurred while performing the lab test. The most
prominent error is human error. Someone could have miss counted while using the
hammer or there could have been a miss calculation in the computation of the
water needed for the desired water content. Another source of error could be from
a hole in the tube used to mix the water and soil. The amount of soil in the mold
may not have been exactly (997.381 cm3) either, throwing off the calculations.
Compacting at water contents higher than the optimum water content results in a
relatively dispersed soil structure that is weaker, more ductile, less porous, softer,
more susceptible to shrinking, and less susceptible to swelling than soil compacted
dry of optimum to the same density. The soil compacted lower than the optimum
water content typically results in a flocculated soil structure (random particle
orientations) that has the opposite characteristics of the soil compacted wet of the
optimum water content to the same density
In conclusion, the test has failed and the test should be done again using a correct
balance with a sensitivity of (0.1g) or better, and more accuracy while mixing and
compacting the soil for more accurate and dependable results.

More Related Content

What's hot

Sand Replacement Method
Sand Replacement MethodSand Replacement Method
Sand Replacement Method
MachenLink
 

What's hot (20)

Best numerical problem group pile capacity (usefulsearch.org) (useful search)
Best numerical problem group pile capacity (usefulsearch.org) (useful search)Best numerical problem group pile capacity (usefulsearch.org) (useful search)
Best numerical problem group pile capacity (usefulsearch.org) (useful search)
 
Presentation on plastic limit
Presentation on plastic limitPresentation on plastic limit
Presentation on plastic limit
 
Laboratory soil compaction test
Laboratory soil compaction testLaboratory soil compaction test
Laboratory soil compaction test
 
Question bank of soil mechanics
Question bank of soil mechanicsQuestion bank of soil mechanics
Question bank of soil mechanics
 
coulomb's theory of earth pressure
 coulomb's theory of earth pressure coulomb's theory of earth pressure
coulomb's theory of earth pressure
 
Class 6 Shear Strength - Direct Shear Test ( Geotechnical Engineering )
Class 6    Shear Strength - Direct Shear Test ( Geotechnical Engineering )Class 6    Shear Strength - Direct Shear Test ( Geotechnical Engineering )
Class 6 Shear Strength - Direct Shear Test ( Geotechnical Engineering )
 
Index properties
Index propertiesIndex properties
Index properties
 
Geotechnical Engineering-I [Lec #24: Soil Permeability - II]
Geotechnical Engineering-I [Lec #24: Soil Permeability - II]Geotechnical Engineering-I [Lec #24: Soil Permeability - II]
Geotechnical Engineering-I [Lec #24: Soil Permeability - II]
 
Geotechnical Engineering-II [Lec #7A: Boussinesq Method]
Geotechnical Engineering-II [Lec #7A: Boussinesq Method]Geotechnical Engineering-II [Lec #7A: Boussinesq Method]
Geotechnical Engineering-II [Lec #7A: Boussinesq Method]
 
Class 3 (a) Soil Plasticity (Atterberg Limits) ( Geotechenical Engineering )
Class 3 (a)   Soil Plasticity (Atterberg Limits) ( Geotechenical Engineering )Class 3 (a)   Soil Plasticity (Atterberg Limits) ( Geotechenical Engineering )
Class 3 (a) Soil Plasticity (Atterberg Limits) ( Geotechenical Engineering )
 
Class 7 Consolidation Test ( Geotechnical Engineering )
Class 7    Consolidation Test ( Geotechnical Engineering )Class 7    Consolidation Test ( Geotechnical Engineering )
Class 7 Consolidation Test ( Geotechnical Engineering )
 
Geotechnical Engineering-II [Lec #28: Finite Slope Stability Analysis]
Geotechnical Engineering-II [Lec #28: Finite Slope Stability Analysis]Geotechnical Engineering-II [Lec #28: Finite Slope Stability Analysis]
Geotechnical Engineering-II [Lec #28: Finite Slope Stability Analysis]
 
Cbr test
Cbr testCbr test
Cbr test
 
Sand Replacement Method
Sand Replacement MethodSand Replacement Method
Sand Replacement Method
 
Direct shear test triaxial test
Direct shear test triaxial testDirect shear test triaxial test
Direct shear test triaxial test
 
Numerical Question on Terzaghi Bearing Capacity Theory, Meyerhof Bearing Capa...
Numerical Question on Terzaghi Bearing Capacity Theory, Meyerhof Bearing Capa...Numerical Question on Terzaghi Bearing Capacity Theory, Meyerhof Bearing Capa...
Numerical Question on Terzaghi Bearing Capacity Theory, Meyerhof Bearing Capa...
 
Standard Penetration Test
Standard Penetration TestStandard Penetration Test
Standard Penetration Test
 
Class 8 Triaxial Test ( Geotechnical Engineering )
Class 8    Triaxial Test ( Geotechnical Engineering )Class 8    Triaxial Test ( Geotechnical Engineering )
Class 8 Triaxial Test ( Geotechnical Engineering )
 
Atterberg limit test
Atterberg limit test Atterberg limit test
Atterberg limit test
 
Shear Strength of Soil
Shear Strength of SoilShear Strength of Soil
Shear Strength of Soil
 

Similar to Standard proctor test

compaction test
compaction testcompaction test
compaction test
Bahzad5
 
Standard Proctor Compaction TestName .docx
Standard Proctor Compaction TestName .docxStandard Proctor Compaction TestName .docx
Standard Proctor Compaction TestName .docx
whitneyleman54422
 
Atterberg limit test
Atterberg limit testAtterberg limit test
Atterberg limit test
Bahzad5
 

Similar to Standard proctor test (20)

compaction test
compaction testcompaction test
compaction test
 
Standard Compaction Test | Jameel Academy
Standard Compaction Test | Jameel AcademyStandard Compaction Test | Jameel Academy
Standard Compaction Test | Jameel Academy
 
Compaction test of soil ASTM-D698
Compaction test of soil ASTM-D698Compaction test of soil ASTM-D698
Compaction test of soil ASTM-D698
 
Proctor Compaction Test
Proctor Compaction TestProctor Compaction Test
Proctor Compaction Test
 
Proctor Compaction Test
Proctor Compaction TestProctor Compaction Test
Proctor Compaction Test
 
Ex 8 standard proctor test
Ex 8 standard proctor testEx 8 standard proctor test
Ex 8 standard proctor test
 
Liquid limit & plastic limit test
Liquid limit & plastic limit testLiquid limit & plastic limit test
Liquid limit & plastic limit test
 
Soil Compaction
Soil Compaction Soil Compaction
Soil Compaction
 
Standard Proctor Compaction TestName .docx
Standard Proctor Compaction TestName .docxStandard Proctor Compaction TestName .docx
Standard Proctor Compaction TestName .docx
 
Soil Compaction slide.pptx
Soil Compaction slide.pptxSoil Compaction slide.pptx
Soil Compaction slide.pptx
 
Subgrade soil test, by Micotol
Subgrade soil test, by MicotolSubgrade soil test, by Micotol
Subgrade soil test, by Micotol
 
CT-233 SOIL MECHANICS LAB MANUAL BSC Civil
CT-233 SOIL MECHANICS LAB MANUAL BSC Civil CT-233 SOIL MECHANICS LAB MANUAL BSC Civil
CT-233 SOIL MECHANICS LAB MANUAL BSC Civil
 
Lecture soil compaction
Lecture  soil compactionLecture  soil compaction
Lecture soil compaction
 
Lecture soil compaction
Lecture  soil compactionLecture  soil compaction
Lecture soil compaction
 
Permeability test
Permeability testPermeability test
Permeability test
 
GT Lab Manual
GT Lab ManualGT Lab Manual
GT Lab Manual
 
upe T99180
upe T99180upe T99180
upe T99180
 
Atterberg limit test
Atterberg limit testAtterberg limit test
Atterberg limit test
 
Proctor Compaction Test: A Basic Guide
Proctor Compaction Test: A Basic GuideProctor Compaction Test: A Basic Guide
Proctor Compaction Test: A Basic Guide
 
Foundation Engineering Lab Manual
Foundation Engineering Lab ManualFoundation Engineering Lab Manual
Foundation Engineering Lab Manual
 

Recently uploaded

FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Dr.Costas Sachpazis
 

Recently uploaded (20)

PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Vivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design SpainVivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design Spain
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 

Standard proctor test

  • 1. University of Sulaimani College of Engineering Civil Engineering Department (Soil Mechanics Lab) Name of the Test: Standard Proctor Compaction Test Test No. : Students Name: 1- Raz Azad Abdullah 2- Zhyar Abu-Bakr 3- Rawezh Saady Group & Sub-Group: A1-A6 Date of the Test:
  • 2. 1 Introduction: Compaction is a method of mechanically increasing the density of soil, and it’s especially valuable in construction applications. If this process is not performed properly, soil settlement can occur, resulting in unnecessary maintenance costs or failure of the pavement or structure. For construction of highways, airports, and other structures, it is often necessary to compact soil to improve its strength. Proctor (1933) developed a laboratory compaction test procedure to determine the maximum dry unit weight of compaction of soils, which can be used for specification of field compaction. This test is referred to as the Standard Proctor Compaction Test. It is based on compaction of soil fraction passing No. 4 U.S. sieve. Purpose: The testing first determines the maximum density achievable for the soil and uses it as a reference for field testing. It also is effective for testing the effects of moisture on the soil's density. There are a variety of different benefits to soil compaction, including: prevention of soil settlement and frost damage, increased ground stability, reduced hydraulic conductivity and mitigating undesirable settlement of structures, such as paved roads, foundations and piping.
  • 3. 2 Equipment:  Compaction mold  No.4 U.S. sieve  Standard Proctor hammer (5.5lb)(24.5N)  Balance sensitive up to 0.01 lb  Balance sensitive up to 0.1 g  Large flat pan  Jack  Steel straight edge  Moisture cans  Drying oven  Plastic squeeze bottle with water
  • 4. 3 Procedure: 1. Obtain about 10 lb (4.5 kg) of air-dry soil on which the compaction test is to be conducted. Break all the soil lumps. 2. Sieve the soil on a No.4 U.S. sieve. Collect all of the minus-4 material in a large pan. This should be about 6lb (2.7 kg) or more. 3. Add enough water to the minus-4 material and mix it in thoroughly to bring the moisture content up to about ~. 4. Determine the weight of the Proctor mold + base plate (not the extension), WI' (lb). 5. Now attach the extension to the top of the mold. 6. 'Pour the moist soil into the mold in three equal layers. Each layer should be compacted uniformly by the standard Proctor hammer 25 times before the next layer of loose soil is poured into the mold. 7. Remove the top attachment from the mold. Be careful not to break off any of the compacted soil inside the mold while removing the top attachment. 8. Using a straight edge, trim the excess soil above the mold (Fig. 12-3). Now the top of the compacted soil will be even with the top of the mold. 9. Determine the weight of the mold + base plate + compacted moist soil in the mold, W2 (lb). 10. Remove the base plate from the mold. Using a jack, extrude the compacted soil cylinder from the mold. 11. Take a weight of can (g). 12. From the moist soil extruded in Step 10, collect a moisture sample in the moisture can (Step II) and determine the mass of the can + moist soil, (g). 13. Place the moisture can with the moist soil in the oven to dry to a constant weight. 14. Break the rest of the compacted soil (to No.4 size) by hand and mix it with the leftover moist soil in the pan. Add more water and mix it to raise the moisture content by about 2%.
  • 5. 4 Calculation: γ = moist unit weight = w2−w1 volume of mold γdry=Dry unit weight = γ 1+ w% 100 %(w)= weight of moist dry weight of soil × 100 = w(can+wet soil)−w(can+dry soil) w(can+dry soil)−w(can) × 100 γ zero air void = γ water w% 100 + 1 Gs Where:- w1=weight of mold+ base plate. w2=weight of mold+ base plate+ compacted moist soil in the mold. w%= moisture content (M.C). Volume of mold = π D2 4 × H = π 9.982 4 × 12.75 = 997.381 cm 1) Can #35: (γ) Moist unit weight = 6412−4626 997.381 = 1.790 g/cm3 𝑀. 𝐶 = 116−113.5 113.5−74.08 × 100 = 6.342% 𝛾𝑑𝑟𝑦 = 1.790 1+ 6.342 100 = 1.528 g/cm3 At same M.C: γ zero air void (γ zav) = 1 6.342 100 + 1 2.7 = 2.305 g/cm3 2) Can #31: (γ) Moist unit weight = 6558−4626 997.381 = 1.937g/cm3 M. C = 128−122.26 122.26−72.99 × 100 = 11.650%
  • 6. 5 γdry = 1.937 1+ 11.650 100 = 1.734g/cm3 At same M.C: γ zero air void (γ zav) = 1 11.650 100 + 1 2.7 = 2.054g/cm3 3) Can#14: (γ) Moist unit weight = 6656−4626 997.381 =2.035g/cm3 M. C = 126−117.97 117.97−76.45 × 100 = 19.34% γdry = 2.034 1+ 19.34 100 = 1.704g/cm3 At same M.C: γ zero air void (γ zav) = 1 19.340 100 + 1 2.7 = 1.773 g/cm3 4) Can#17: (γ) Moist unit weight = 6600−4626 997.381 = 1.979g/cm3 M. C = 114−105.63 105.63−74.91 × 100 = 27.246% γdry = 1.979 1+ 27.246 100 = 1.555 g/cm3 At same M.C: γ zero air void (γ zav) = 1 27.246 100 + 1 2.7 = 1.555 g/cm3
  • 7. 6 Table of Results: O.M.C=13.7% (from the graph) Maximum dry unit weight = 1.74 g/cm3 (from the graph) Test No. Wt. of Mold (g) Wt.of (wet soil+ mold)g Wet unit weight (g/cm3) 1 4626 6412 1.790 2 4626 6558 1.937 3 4626 6656 2.035 4 4626 6600 1.979 Can No. Wt. Of container(g) Wt. Of (wet soil+cont.)(g) Wt. Of (Dry soil+cont.)(g) W.C (%) Dry Unit weight (g/cm3) Max.theorotical dry unit weight (g/cm3) γ (zav.) (g/cm3) 35 74.08 116 113.5 6.341 1.681 2.232 2.305 31 72.99 128 122.26 11.65 1.734 1.995 2.054 14 76.45 126 117.97 19.34 1.704 1.73 1.773 17 74.91 114 105.63 27.246 1.554 1.523 1.555
  • 8. 7
  • 9. 8 Discussion& Conclusion: The Proctor compaction test is a laboratory method of experimentally determining the optimal moisture content at which a given soil type will become most dense and achieve its maximum dry density., compaction of soil increases the shear strength of the soil, increase the bearing capacity, also reduces erosion and it will give the soil more stability, and reduces voids between the particles so that it makes the soil more difficult for water to flow through soil. In this soil sample, from the graph the soil has a maximum dry unit weight of (1.74 g/c𝑚3 ) with the optimum moisture content of (13.7%), but after calculation of zero-air-void curve and plotting on the graph we saw that the last point of the real soil curve intersects with the zero-air-void curve, which it means the soil sample became void less and goes beyond the theoretical curve which is not acceptable. Many errors could have occurred while performing the lab test. The most prominent error is human error. Someone could have miss counted while using the hammer or there could have been a miss calculation in the computation of the water needed for the desired water content. Another source of error could be from a hole in the tube used to mix the water and soil. The amount of soil in the mold may not have been exactly (997.381 cm3) either, throwing off the calculations. Compacting at water contents higher than the optimum water content results in a relatively dispersed soil structure that is weaker, more ductile, less porous, softer, more susceptible to shrinking, and less susceptible to swelling than soil compacted dry of optimum to the same density. The soil compacted lower than the optimum water content typically results in a flocculated soil structure (random particle orientations) that has the opposite characteristics of the soil compacted wet of the optimum water content to the same density In conclusion, the test has failed and the test should be done again using a correct balance with a sensitivity of (0.1g) or better, and more accuracy while mixing and compacting the soil for more accurate and dependable results.