EC PERMANENT MAGNET
MOTORS AND CONTROLLERS
Sustainable innovative solutions
3
Domel draws its creative energy from its rich industrial tradition,
and is a globally recognized developmental manufacturer
and supplier of various electric motors. Through our network of
representative offices, Domel is present on all of the world’s leading
markets and our motors are used in over 250 million appliances
worldwide.
We are a developmental supplier with a clear vision and in-house
development, through which we create trends and technical solu-
tions at all levels of individual products and devices. Domel has
received numerous awards from independent technical and con-
sumer organizations, our laboratories are part of the national and
international development network, we invest a great deal into social
responsibility and enjoy long-standing collaboration with manufac-
turers in numerous branches of industry.
Our organizational structure allows us to respond flexibly to our cus-
tomer’s individual requirements. First-class standards are assured
by our in-house quality management system, where the develop-
ment phase is strongly connected to the needs of our customers.
With the help of various simulation techniques we can design the
right electric motor for any application. The basis of our expertise
lies in our highly motivated staff, who can, by the use of modern
methods and equipment, develop a state-of-the-art product.
Vision
We want to become one of the leading global developers and sup-
pliers of EC motors and maintain our leading position in the vacuum
cleaner motors market.
Mission
Domel is a socially responsible company. As a global developer and
supplier of advanced solutions in the field of electric motors and
components based on our own innovative technologies, we enable
the growth and sustainable development of the Domel group, in this
way providing quality jobs in the broader environment.
DOMEL, Slovenia
With DOMEL towards an energy-efficient future
- Area: 20.273 km2
(7,827 mi2
)
- Population: about 2 million
- Capital city: Ljubljana
- Language: Slovenian
- Currency: euro (EUR)
- Neighboring countries: Italy, Austria, Hungary and Croatia
- Calling Code: +386
- Time Zone: Central European Time (CET) and Central European
	 Summer Time (CEST) in summer
Facts about Slovenia
4
EC MOTORS
Domel has been independently developing EC motors since
1986. Over the years we have gained the knowledge and expertise
of key motor technologies (stamping and molding) and enriched
core R&D competences in electromagnetics, aerodynamics, acous-
tics, rotodynamics, power electronics, rapid prototyping and testing.
With all the in-house knowhow Domel is now present in various
markets where EC technology is becoming more and more no-
ticeable. Some of the applications where you can find Domel’s EC
motors are HVAC systems, gardening appliances, power tools, au-
tomotive components, white goods, vacuum cleaners, fume/smoke
extraction devices, boilers, handling devices, medical and labora-
tory equipment, and much more…
Increased awareness about energy savings lead Domel to develop
EC motors and controllers for HVAC industry, which is one of the top
leading users of electricity consumption. In 2009 serial produc-
tion of EC motors, named AZ motors, was industrialized.
When developing highly efficient AZ motors, we placed consider-
able emphasis on the optimum use of materials, state-of-the-art
technology and long-life operation. The excellence of these mo-
tors is further enhanced by their high capacity and strongly wear-
resistant housing, optimal coordination between the motor and
controller, and the monitoring of the rotor position without Hall sen-
sors. They require no maintenance since, with the exception of the
bearing system, they do not contain any mechanical parts which are
susceptible to wear and tear. The motors are highly efficient (up to
a level of approx. 95%) and have an excellent power capability. It is
worth adding that AZ motors are extremely compact with very short
bed length.
5
ENVIRONMENTAL CARE
In an era of rising energy prices, concerns about reliance on gas, cli-
mate changes and environmental taxes, the awareness of the impor-
tance of the environment and energy saving has never been higher.
Naturally, this trend is not only driven by increased awareness about
energy saving, but also as a result of international political activities,
which are becoming increasingly stringent.
Heating, ventilation and air conditioning are among the five leading
users of electricity consumption. Domel followed the trend in con-
tributing to energy savings and, in 2009, commenced with the serial
production of EC motors specifically designed for HVAC applications,
named AZ motors. These motors adhere to the regulations and direc-
tives for motor efficiency requirements and guarantee enormous en-
ergy savings and hence improved Return on Investment. The
products exceed the IE4 Super Premium efficiency class and, in ac-
cordance with the newly proposed standard, also fulfill the criteria for
the IE5 Ultra Premium efficiency class (according to IEC 60034-30).
When purchasing a motor driven system, lifetime costs are of con-
siderable importance. To only compare purchase prices is a false
economy which overlooks the considerable financial benefits of the
lower operating costs that may be achieved with a more efficient
and quality system.
Our motors reduce operating costs by working at very high level
of efficiency within a wide speed and power range. Ad-
vanced technology and state-of-the-art equipment assures highest
quality and long lifetime of the product with maintenance-
free operation.
In comparison to standard AC motors in the IE2 High efficiency class,
annual production of Domel’s AZ motors additionally saves more than
100 GWh of electricity each year, which is comparable to the annual
supply of a medium-sized hydro power plant.
Source: standard IEC/EN 60034-30
Source: Europe‘s Energy Portal
(www.energy.eu)
Legend:
High Efficiency (IE2) is equivalent to U.S. EPAct
Premium Efficiency (IE3) is equivalent to U.S. NEMA Premium
Savings in EUR for 5,5kW motor operating 4000 hours per year in comparison
to AC motor (IE2)
95
90
85
80
75
1 2 3 4 5 6 7 8 9 10
2 3 4 5 6 7
Efficiency[%]
Power [kW]
Power [HP]
Domel EC motor
IE4
IE3
IE2
Pay attention to the lifetime
operating costs
Saving environment
In other words, Domel annually saves about 60.000 t CO2
,
which is equivalent to:
-- the average generated exhaust of a vehicle traveling 300 million
kilometers
-- 2.200 hectares of forest preserved
-- 9.500 home´s electricity use.
Source: Europe´s Energy Portal (www.energy.eu), Greenhouse Gas Equivalencies Calculator (www.epa.gov/energy)
6
AZ MOTORS
OVERVIEW
*Motors are available in two options – with or without additional cooling.
Motors without additional cooling can only be used in applications where motor is mounted into the airstream. For all other applications motor needs to be temperature
tested or additional cooling is needed.
Highlights
-- extremely high efficiency up to 95%
-- very high efficiency throughout the entire operating area
-- use of non-rare earth magnets (ferrite magnets)
-- highest quality with long lifetime
-- maintenance-free operation
-- very low noise
-- low weight
-- compact design
-- improved Return On Investment (ROI)
-- compatible with all leading controller brands
Features
Applications
-- axial fans
-- plug fans
-- centrifugal fans (backward or forward curved blades)
-- mixed flow fans
-- pumps
-- compressors
-- other
AZ motors are electronically commutated (EC) motors, available in brushless DC (BLDC) or permanent magnet synchronous (PMS) motor versions.
They are available in four frame sizes: AZ 84, AZ 108, AZ 150 and AZ 220.
Torque from 1,5 Nm to 45 Nm / from 1.0 Ft-Lb to 30 Ft-Lb
Efficiency all motors exceed IE4 Super-Premium efficiency class / efficiency up to 95%
Speed variable nominal speeds
Supply voltage 208-240 VAC, 380-480 VAC
Nr. of poles and phases 10-pole, three-phase motors
Dust and humidity protection IP54 or IP65 (with additional sealing)
Ambient temperature between -40 °C and +50 °C * / between -40 °F and +120 °F *
Insulation class F
Temperature rise class B
Corrosion protection C4 - high
Mounting B14
Assembly in Slovenia (European Union); ISO 9001, ISO 14001 and ISO/TS 16949 certified
Agency CE®
marked, UL®
recognized
EC motors require a motor controller and cannot be run
directly off the mains AC power supply.
7
MOTOR SIZE AZ 84
Motor Type
Nominal torque Dimensions A Weight
[Nm] [Ft-Lb] [mm] [in] [kg] [lbs]
AZ 84-50 3,0 2.2 140,7 5.54 5,1 11.2
AZ 84-50 with additional cooling 3,0 2.2 164 6.46 5,3 11.7
Weight may vary due to construction differences and different electrical data between the motors.
AZ 84
AZ 84 with additional cooling
Motor
Motor
current
Nominal torque
Nominal
speed
Motor
poles
BackEMF
Resistance
Rs
Inductance
Ld
[A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH]
AZ 84-50-S070A 3,0 3,0 2.2 4500 10 68 1,94 7,2
Legend:
Motor current:	 Nominal motor current per line
Nominal torque:	 Design torque of the motor
Nominal speed:	 Design speed of the motor
Motor poles:	 Number of motor poles
BackEMF:	 RMS value of Back EMF at 1000 rpm, line to line
Ld:	 Inductance at d-axis position, line to star-point
Rs:	 Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
8
MOTOR SIZE AZ 108
Weight may vary due to construction differences and different electrical data between the motors.
Motor Type
Nominal torque
Dimensions
Weight
A B C D
[Nm] [Ft-Lb] [mm] [in] [mm] [in] [mm] [in] Thread [kg] [lbs]
AZ 108-30 3,5 2.5 136,5 5.37
ø95 ø3.74 ø115 ø4.53 M8
5,7 12.6
ø80 ø3.15 ø100 ø3.94 M6
AZ 108-30 with additional cooling 3,5 2.5 167,8 6.61
ø95 ø3.74 ø115 ø4.53 M8
6,3 13.9
ø80 ø3.15 ø100 ø3.94 M6
AZ 108-55 5,5 4.0 161,5 6.36
ø95 ø3.74 ø115 ø4.53 M8
7,6 16.8
ø80 ø3.15 ø100 ø3.94 M6
AZ 108-55 with additional cooling 5,5 4.0 192,8 7.59
ø95 ø3.74 ø115 ø4.53 M8
8,3 18.3
ø80 ø3.15 ø100 ø3.94 M6
AZ 108
AZ 108 with additional cooling
Motor
Motor
current
Nominal torque
Nominal
speed
Motor
poles
BackEMF
Resistance
Rs
Inductance
Ld
[A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH]
AZ 108-30-S090A 3,0 3,0 2.2 4500 10 67 1,35 11,0
AZ 108-30-S120A 2,3 3,0 2.2 3400 10 88 2,14 21,4
AZ 108-55-S060A 4,2 5,0 3.7 3800 10 79 0,91 8,0
AZ 108-55-S075A 3,5 5,0 3.7 3100 10 96 1,38 13,1
Legend:
Motor current:	 Nominal motor current per line
Nominal torque:	 Design torque of the motor
Nominal speed:	 Design speed of the motor
Motor poles:	 Number of motor poles
BackEMF:	 RMS value of Back EMF at 1000 rpm, line to line
Ld:	 Inductance at d-axis position, line to star-point
Rs:	 Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
9
Motor
Motor
current
Nominal torque
Nominal
speed
Motor
poles
BackEMF
Resistance
Rs
Inductance
Ld
[A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH]
AZ 150-45-S090A 4,0 7,5 5.5 2250 10 126 0,98 19,8
AZ 150-70-S070A 5,1 11,5 8.5 1900 10 150 0,77 16,3
AZ 150-70-D070A 8,4 11,0 8.1 3200 10 87 0,26 5,4
Legend:
Motor current:	 Nominal motor current per line
Nominal torque:	 Design torque of the motor
Nominal speed:	 Design speed of the motor
Motor poles:	 Number of motor poles
BackEMF:	 RMS value of Back EMF at 1000 rpm, line to line
Ld:	 Inductance at d-axis position, line to star-point
Rs:	 Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
MOTOR SIZE AZ 150
Weight may vary due to construction differences and different electrical data between the motors.
Motor Type
Nominal torque Dimension A Weight
[Nm] [Ft-Lb] [mm] [in] [kg] [lbs]
AZ 150-45 8 6 147 5.79 11,3 24.9
AZ 150-45 with additional cooling 8 6 188 7.40 12,0 26.5
AZ 150-70 13 9.5 172 6.77 14,7 32.4
AZ 150-70 with additional cooling 13 9.5 213 8.39 15,4 34.0
AZ 150-100 18 13 202 7.95 20,7 45.6
AZ 150-100 with additional cooling 18 13 202 7.95 20,7 45.6
AZ 150
AZ 150 with additional cooling
10
MOTOR SIZE AZ 220
Weight may vary due to construction differences and different electrical data between the motors.
Motor Type
Nominal torque Dimension A Weight
[Nm] [Ft-Lb] [mm] [in] [kg] [lbs]
AZ 220-55 24 17 172 6.77 27,0 59.5
AZ 220-55 with additional cooling 24 17 227,3 8.95 27,9 61.5
AZ 220-100 45 30 217 8.54 39,5 87.1
AZ 220-100 with additional cooling 45 30 272,3 10.72 40,6 89.5
AZ 220
AZ 220 with additional cooling
Motor
Motor
current
Nominal torque
Nominal
speed
Motor
poles
BackEMF
Resistance
Rs
Inductance
Ld
[A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH]
AZ 220-55-D105A 9,3 22 16.2 1700 10 157 0,33 10,0
AZ 220-55-P172A 12,0 22 16.2 2050 10 122 0,18 6,7
AZ 220-100-P150A 14,2 40 29.5 1400 10 187 0,19 10,3
AZ 220-100-P120A 17,7 40 29.5 1750 10 150 0,15 6,6
Legend:
Motor current:	 Nominal motor current per line
Nominal torque:	 Design torque of the motor
Nominal speed:	 Design speed of the motor
Motor poles:	 Number of motor poles
BackEMF:	 RMS value of Back EMF at 1000 rpm, line to line
Ld:	 Inductance at d-axis position, line to star-point
Rs:	 Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
11
NZ MOTORS
OVERVIEW
Features
NZ motors are electronically commutaed (EC) motors which can cover higher torques than already well-known AZ motors. Efficiency of the motors
has been improved on the entire operating area, even though keeping the use non-rare ferrite magnets.
They are available in frame size: NZ 270.
Torque from 45 Nm to 80 Nm / from 30 Ft-Lb to 60 Ft-Lb
Efficiency all motors fulfil IE5 Ultra-Premium efficiency class / losses are more than 20% lower compared to IE4 Super-Premium motors
Speed variable nominal speeds
Supply voltage 208-240 VAC, 380-480 VAC
Nr. of poles and phases 12-pole, three-phase motors
Dust and humidity protection IP54 or IP65 (with additional sealing)
Ambient temperature between -40 °C and +50 °C * / between -40 °F and +120 °F *
Insulation class F
Temperature rise class B
Corrosion protection C4 - high
Mounting B14
Assembly in Slovenia (European Union); ISO 9001, ISO 14001 and ISO/TS 16949 certified
Agency CE®
marked
*Motors are available in two options – with or without additional cooling.
Motors without additional cooling can only be used in applications where motor is mounted into the airstream. For all other applications motor needs to be temperature
tested or additional cooling is needed.
Highlights
-- extremely high efficiency up to 96%
-- very high efficiency throughout the entire operating area
-- use of non-rare earth magnets (ferrite magnets)
-- highest quality with long lifetime
-- maintenance-free operation
-- very low noise
-- low weight
-- compact design
-- improved Return On Investment (ROI)
-- compatible with all leading controller brands
Applications
-- axial fans
-- plug fans
-- centrifugal fans (backward or forward curved blades)
-- mixed flow fans
-- pumps
-- compressors
-- other
EC motors require a motor controller and cannot be run
directly off the mains AC power supply.
12
MOTOR SIZE NZ 270
Weight may vary due to construction differences and different electrical data between the motors.
Motor Type
Nominal torque Dimension A Weight
[Nm] [Ft-Lb] [mm] [in] [kg] [lbs]
NZ 270-80 55 40 256 10.08 37,5 82.7
NZ 270-80 with additional cooling 55 40 311,3 12.26 38,6 85.1
NZ 270-120 80 60 296 11.65 41,5 91.5
NZ 270-120 with additional cooling 80 60 351,3 13.83 42,6 93.5
NZ 270
NZ 270 with additional cooling
Motor
Motor
current
Nominal torque
Nominal
speed
Motor
poles
BackEMF
Resistance
Rs
Inductance
Ld
[A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH]
NZ270080S016 17,5 44 32.5 1680 12 173 0,36 4,5
NZ270120S012 23 65 48.0 1650 12 197 0,26 3,8
NZ270120S018 15,5 65 48.0 1100 12 295 0,59 8,4
Legend:
Motor current:	 Nominal motor current per line
Nominal torque:	 Design torque of the motor
Nominal speed:	 Design speed of the motor
Motor poles:	 Number of motor poles
BackEMF:	 RMS value of Back EMF at 1000 rpm, line to line
Ld:	 Inductance at d-axis position, line to star-point
Rs:	 Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
13
Highlights
-- customized to customer’s needs
-- high efficiency
-- long lifetime
-- robust construction
-- can be used in wide range of applications
-- lower operating costs due to energy efficient solution
Features
CONTROLLERS
OVERVIEW
Compacto Invento S
Output power (P2
) up to 1,1 kW / up to 1.5 HP up to 5,5 kW / up to 7.5 HP
Mains voltage 1x230 VAC ± 10%, 50/60 Hz 3x400 VAC ± 10%, 50/60 Hz
Efficiency up to 95% up to 98%
Speed variable nominal speeds, 10-100% continuously adjustable
Dust and humidity protection IP55
Commutation sensorless
Ambient temperature between -10 °C and +45 °C / between 14 °F and 113 °F
Assembly in Slovenia (European Union) ISO 9001, ISO 14001 and ISO/TS 16949 certified
Agency CE®
marked
EC motors are able to run only if connected to an EC controller. Domel offers two EC motor controller versions – Compacto and Invento S.
14
Functions
-- Active PFC
-- Speed control via external analogue signal 0-10 V
-- Speed control via potentiometer
-- Speed control via MODBUS
-- Motor direction change via MODBUS
-- Open Collector speed output – current speed of the motor can
be displayed as:
-- analogue value – voltage or current signal
-- digital value – PWM or pulse signal
-- Fault relay output
-- DC voltage output +5 V, +24 V
-- Start / Stop function
-- Fire Mode safety function
-- Internal PID regulator
-- Analogue input for external sensor (temperature, CO2
, smoke
sensor, etc.)
-- Resonance avoidance function
CONTROLLER COMPACTO
Data above represents the performance of an average sample. Individual data
may vary due to normal manufacturing variations.
Controller Type
Output power Output current Weight
[kW] [HP] [A] [kg] [lbs]
Compacto 08 0,80 1.0 4 A 4,2 9.3
Compacto 11 1,10 1.5 6 A 4,2 9.3
15
Functions
-- Passive PFC
-- Speed control via external analogue signal 0-10 V
-- Speed control via potentiometer
-- Speed control via MODBUS
-- Motor direction change via MODBUS
-- Open Collector speed output – current speed of the motor can
be displayed as:
-- analogue value – voltage or current signal
-- digital value – PWM or pulse signal
-- Fault relay output
-- DC voltage output +10 V, +24 V
-- Start / Stop function
-- Fire Mode safety function
-- Internal PID regulator
-- Analogue input for external sensor (temperature, CO2
, smoke
sensor, etc.)
-- Resonance avoidance function
CONTROLLER INVENTO S
Data above represents the performance of an average sample. Individual data
may vary due to normal manufacturing variations.
Controller Type
Output power Output current Weight
[kW] [HP] [A] [kg] [lbs]
Invento S15 1,5 2.0 3,7 5,5 12.1
Invento S22 2,2 3.0 5,3 5,5 12.1
Invento S30 3,0 4.0 7,2 6,2 13.7
Invento S40 4,0 5.5 9,1 6,5 14.3
Invento S55 5,5 7.5 12,0 7,2 15.9
NOTES
Sustainable innovative solutions
KD52-MAR16
Domel, d.o.o.
Otoki 21, 4228 Železniki, Slovenija
Tel.: +386 (0)4 51 17 100, Fax: +386 (0)4 51 17 106
www.domel.com
e-mail: info@domel.com

More Related Content

What's hot

Meen 442 Journal Final Pdf V2
Meen 442 Journal Final Pdf V2Meen 442 Journal Final Pdf V2
Meen 442 Journal Final Pdf V2
halfmann4
 
Giao trinh do_ga
Giao trinh do_gaGiao trinh do_ga
Giao trinh do_ga
Kỳ Kỳ
 
Model Optimization and structural Analysis of a Car Rim
Model Optimization and structural Analysis of a Car RimModel Optimization and structural Analysis of a Car Rim
Model Optimization and structural Analysis of a Car Rim
Sai Narayana
 
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
Man_Ebook
 
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
Man_Ebook
 
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdfGiáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
Man_Ebook
 

What's hot (20)

Use of cfd in aerodynamic performance of race car
Use of cfd in aerodynamic performance of race carUse of cfd in aerodynamic performance of race car
Use of cfd in aerodynamic performance of race car
 
Khớp nối - chương 14
Khớp nối - chương 14Khớp nối - chương 14
Khớp nối - chương 14
 
Meen 442 Journal Final Pdf V2
Meen 442 Journal Final Pdf V2Meen 442 Journal Final Pdf V2
Meen 442 Journal Final Pdf V2
 
Thiết kế quy trình công nghệ chế tạo chi tiết Tay Biên D165, HAY - Gửi miễn p...
Thiết kế quy trình công nghệ chế tạo chi tiết Tay Biên D165, HAY - Gửi miễn p...Thiết kế quy trình công nghệ chế tạo chi tiết Tay Biên D165, HAY - Gửi miễn p...
Thiết kế quy trình công nghệ chế tạo chi tiết Tay Biên D165, HAY - Gửi miễn p...
 
Giao trinh do_ga
Giao trinh do_gaGiao trinh do_ga
Giao trinh do_ga
 
Báo cáo thí nghiệm cơ sở máy cnc đh bách khoa hà nội 5868537
Báo cáo thí nghiệm cơ sở máy cnc đh bách khoa hà nội 5868537Báo cáo thí nghiệm cơ sở máy cnc đh bách khoa hà nội 5868537
Báo cáo thí nghiệm cơ sở máy cnc đh bách khoa hà nội 5868537
 
Tính toán kiểm bền khung xe tải 500kg
Tính toán kiểm bền khung xe tải 500kgTính toán kiểm bền khung xe tải 500kg
Tính toán kiểm bền khung xe tải 500kg
 
Gear Box and Torque Converter- CSVTU
Gear Box and Torque Converter- CSVTUGear Box and Torque Converter- CSVTU
Gear Box and Torque Converter- CSVTU
 
Global Test & Defect Management for the Future of Mobility - Gunther Fabian (...
Global Test & Defect Management for the Future of Mobility - Gunther Fabian (...Global Test & Defect Management for the Future of Mobility - Gunther Fabian (...
Global Test & Defect Management for the Future of Mobility - Gunther Fabian (...
 
Đề tài: Tính năng động lực học của ô tô TOYOTA INNOVA G
Đề tài: Tính năng động lực học của ô tô TOYOTA INNOVA GĐề tài: Tính năng động lực học của ô tô TOYOTA INNOVA G
Đề tài: Tính năng động lực học của ô tô TOYOTA INNOVA G
 
Model Optimization and structural Analysis of a Car Rim
Model Optimization and structural Analysis of a Car RimModel Optimization and structural Analysis of a Car Rim
Model Optimization and structural Analysis of a Car Rim
 
Mechanical Engineering Standard Design Data Book
Mechanical Engineering Standard Design Data BookMechanical Engineering Standard Design Data Book
Mechanical Engineering Standard Design Data Book
 
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
Xây dựng mô hình tính toán cơ cấu chấp hành trong hệ thống phanh khí nén tran...
 
124817348 ejercicios-solidworks-pdf
124817348 ejercicios-solidworks-pdf124817348 ejercicios-solidworks-pdf
124817348 ejercicios-solidworks-pdf
 
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
Khảo sát động lực học ô tô tăng tốc và quay vòng bằng mô hình động lực học mộ...
 
Selective catalyst reduction
Selective catalyst reductionSelective catalyst reduction
Selective catalyst reduction
 
Đề tài: Thiết kế máy khoan tự động, HAY, 9đ
Đề tài: Thiết kế máy khoan tự động, HAY, 9đĐề tài: Thiết kế máy khoan tự động, HAY, 9đ
Đề tài: Thiết kế máy khoan tự động, HAY, 9đ
 
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdfGiáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
Giáo trình công nghệ khuôn mẫu - Trần Minh Thế Uyên, Phạm Sơn Minh.pdf
 
A Seminar Report On Six Stroke Engine
A Seminar Report On Six Stroke EngineA Seminar Report On Six Stroke Engine
A Seminar Report On Six Stroke Engine
 
Inbuilt hydraulic jack ppt
Inbuilt hydraulic jack pptInbuilt hydraulic jack ppt
Inbuilt hydraulic jack ppt
 

Similar to EC Motors & Controllers March 2016

ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENTENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
kypameenendranathred
 
Capiel Motori Elettrici efficienti
Capiel Motori Elettrici efficientiCapiel Motori Elettrici efficienti
Capiel Motori Elettrici efficienti
ANIE Energia
 
Energy efficient motors
Energy efficient motorsEnergy efficient motors
Energy efficient motors
vimalbajaj
 
eemppt-150726072411-lva1-app6891.pptGGDEC
eemppt-150726072411-lva1-app6891.pptGGDECeemppt-150726072411-lva1-app6891.pptGGDEC
eemppt-150726072411-lva1-app6891.pptGGDEC
r29489791
 

Similar to EC Motors & Controllers March 2016 (20)

The Complete Motor Solution - WEG and ERIKS
The Complete Motor Solution - WEG and ERIKS  The Complete Motor Solution - WEG and ERIKS
The Complete Motor Solution - WEG and ERIKS
 
ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENTENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
ENERGY EFFICIENT MOTORS AND POWER FACTOR IMPROVEMENT
 
PMSM.pdf
PMSM.pdfPMSM.pdf
PMSM.pdf
 
Energy efficient motors
Energy efficient motorsEnergy efficient motors
Energy efficient motors
 
ePropelled corporate deck oct2020
ePropelled corporate deck oct2020ePropelled corporate deck oct2020
ePropelled corporate deck oct2020
 
ePropelled
ePropelledePropelled
ePropelled
 
Capiel Motori Elettrici efficienti
Capiel Motori Elettrici efficientiCapiel Motori Elettrici efficienti
Capiel Motori Elettrici efficienti
 
Checkout single phase induction motor catalogue and price list.
Checkout single phase induction motor catalogue and price list.Checkout single phase induction motor catalogue and price list.
Checkout single phase induction motor catalogue and price list.
 
Comprehensive Power Introduction July 2013
Comprehensive Power Introduction July 2013Comprehensive Power Introduction July 2013
Comprehensive Power Introduction July 2013
 
Electric motor systems - DecarbEurope
Electric motor systems - DecarbEuropeElectric motor systems - DecarbEurope
Electric motor systems - DecarbEurope
 
Energy efficient motors
Energy efficient motorsEnergy efficient motors
Energy efficient motors
 
21 GSR.pptx
21 GSR.pptx21 GSR.pptx
21 GSR.pptx
 
eemppt-150726072411-lva1-app6891.pptGGDEC
eemppt-150726072411-lva1-app6891.pptGGDECeemppt-150726072411-lva1-app6891.pptGGDEC
eemppt-150726072411-lva1-app6891.pptGGDEC
 
Energy Efficient Motor
Energy Efficient Motor Energy Efficient Motor
Energy Efficient Motor
 
Solutions for Wind Energy Systems | Infineon Technologies
Solutions for Wind Energy Systems | Infineon TechnologiesSolutions for Wind Energy Systems | Infineon Technologies
Solutions for Wind Energy Systems | Infineon Technologies
 
Normes, disseny i ús de motors elèctrics industrials
Normes, disseny i ús de motors elèctrics industrials Normes, disseny i ús de motors elèctrics industrials
Normes, disseny i ús de motors elèctrics industrials
 
Energy efficient induction motor
Energy efficient induction motorEnergy efficient induction motor
Energy efficient induction motor
 
Mitsubishi inverter freqrol-f700 pj series
Mitsubishi inverter freqrol-f700 pj seriesMitsubishi inverter freqrol-f700 pj series
Mitsubishi inverter freqrol-f700 pj series
 
Mitsubishi inverter freqrol-f700 pj series
Mitsubishi inverter freqrol-f700 pj seriesMitsubishi inverter freqrol-f700 pj series
Mitsubishi inverter freqrol-f700 pj series
 
Mitsubishi inverter freqrol-f700 pj series-dienhathe.vn
Mitsubishi inverter freqrol-f700 pj series-dienhathe.vnMitsubishi inverter freqrol-f700 pj series-dienhathe.vn
Mitsubishi inverter freqrol-f700 pj series-dienhathe.vn
 

EC Motors & Controllers March 2016

  • 1. EC PERMANENT MAGNET MOTORS AND CONTROLLERS
  • 3. 3 Domel draws its creative energy from its rich industrial tradition, and is a globally recognized developmental manufacturer and supplier of various electric motors. Through our network of representative offices, Domel is present on all of the world’s leading markets and our motors are used in over 250 million appliances worldwide. We are a developmental supplier with a clear vision and in-house development, through which we create trends and technical solu- tions at all levels of individual products and devices. Domel has received numerous awards from independent technical and con- sumer organizations, our laboratories are part of the national and international development network, we invest a great deal into social responsibility and enjoy long-standing collaboration with manufac- turers in numerous branches of industry. Our organizational structure allows us to respond flexibly to our cus- tomer’s individual requirements. First-class standards are assured by our in-house quality management system, where the develop- ment phase is strongly connected to the needs of our customers. With the help of various simulation techniques we can design the right electric motor for any application. The basis of our expertise lies in our highly motivated staff, who can, by the use of modern methods and equipment, develop a state-of-the-art product. Vision We want to become one of the leading global developers and sup- pliers of EC motors and maintain our leading position in the vacuum cleaner motors market. Mission Domel is a socially responsible company. As a global developer and supplier of advanced solutions in the field of electric motors and components based on our own innovative technologies, we enable the growth and sustainable development of the Domel group, in this way providing quality jobs in the broader environment. DOMEL, Slovenia With DOMEL towards an energy-efficient future - Area: 20.273 km2 (7,827 mi2 ) - Population: about 2 million - Capital city: Ljubljana - Language: Slovenian - Currency: euro (EUR) - Neighboring countries: Italy, Austria, Hungary and Croatia - Calling Code: +386 - Time Zone: Central European Time (CET) and Central European Summer Time (CEST) in summer Facts about Slovenia
  • 4. 4 EC MOTORS Domel has been independently developing EC motors since 1986. Over the years we have gained the knowledge and expertise of key motor technologies (stamping and molding) and enriched core R&D competences in electromagnetics, aerodynamics, acous- tics, rotodynamics, power electronics, rapid prototyping and testing. With all the in-house knowhow Domel is now present in various markets where EC technology is becoming more and more no- ticeable. Some of the applications where you can find Domel’s EC motors are HVAC systems, gardening appliances, power tools, au- tomotive components, white goods, vacuum cleaners, fume/smoke extraction devices, boilers, handling devices, medical and labora- tory equipment, and much more… Increased awareness about energy savings lead Domel to develop EC motors and controllers for HVAC industry, which is one of the top leading users of electricity consumption. In 2009 serial produc- tion of EC motors, named AZ motors, was industrialized. When developing highly efficient AZ motors, we placed consider- able emphasis on the optimum use of materials, state-of-the-art technology and long-life operation. The excellence of these mo- tors is further enhanced by their high capacity and strongly wear- resistant housing, optimal coordination between the motor and controller, and the monitoring of the rotor position without Hall sen- sors. They require no maintenance since, with the exception of the bearing system, they do not contain any mechanical parts which are susceptible to wear and tear. The motors are highly efficient (up to a level of approx. 95%) and have an excellent power capability. It is worth adding that AZ motors are extremely compact with very short bed length.
  • 5. 5 ENVIRONMENTAL CARE In an era of rising energy prices, concerns about reliance on gas, cli- mate changes and environmental taxes, the awareness of the impor- tance of the environment and energy saving has never been higher. Naturally, this trend is not only driven by increased awareness about energy saving, but also as a result of international political activities, which are becoming increasingly stringent. Heating, ventilation and air conditioning are among the five leading users of electricity consumption. Domel followed the trend in con- tributing to energy savings and, in 2009, commenced with the serial production of EC motors specifically designed for HVAC applications, named AZ motors. These motors adhere to the regulations and direc- tives for motor efficiency requirements and guarantee enormous en- ergy savings and hence improved Return on Investment. The products exceed the IE4 Super Premium efficiency class and, in ac- cordance with the newly proposed standard, also fulfill the criteria for the IE5 Ultra Premium efficiency class (according to IEC 60034-30). When purchasing a motor driven system, lifetime costs are of con- siderable importance. To only compare purchase prices is a false economy which overlooks the considerable financial benefits of the lower operating costs that may be achieved with a more efficient and quality system. Our motors reduce operating costs by working at very high level of efficiency within a wide speed and power range. Ad- vanced technology and state-of-the-art equipment assures highest quality and long lifetime of the product with maintenance- free operation. In comparison to standard AC motors in the IE2 High efficiency class, annual production of Domel’s AZ motors additionally saves more than 100 GWh of electricity each year, which is comparable to the annual supply of a medium-sized hydro power plant. Source: standard IEC/EN 60034-30 Source: Europe‘s Energy Portal (www.energy.eu) Legend: High Efficiency (IE2) is equivalent to U.S. EPAct Premium Efficiency (IE3) is equivalent to U.S. NEMA Premium Savings in EUR for 5,5kW motor operating 4000 hours per year in comparison to AC motor (IE2) 95 90 85 80 75 1 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 Efficiency[%] Power [kW] Power [HP] Domel EC motor IE4 IE3 IE2 Pay attention to the lifetime operating costs Saving environment In other words, Domel annually saves about 60.000 t CO2 , which is equivalent to: -- the average generated exhaust of a vehicle traveling 300 million kilometers -- 2.200 hectares of forest preserved -- 9.500 home´s electricity use. Source: Europe´s Energy Portal (www.energy.eu), Greenhouse Gas Equivalencies Calculator (www.epa.gov/energy)
  • 6. 6 AZ MOTORS OVERVIEW *Motors are available in two options – with or without additional cooling. Motors without additional cooling can only be used in applications where motor is mounted into the airstream. For all other applications motor needs to be temperature tested or additional cooling is needed. Highlights -- extremely high efficiency up to 95% -- very high efficiency throughout the entire operating area -- use of non-rare earth magnets (ferrite magnets) -- highest quality with long lifetime -- maintenance-free operation -- very low noise -- low weight -- compact design -- improved Return On Investment (ROI) -- compatible with all leading controller brands Features Applications -- axial fans -- plug fans -- centrifugal fans (backward or forward curved blades) -- mixed flow fans -- pumps -- compressors -- other AZ motors are electronically commutated (EC) motors, available in brushless DC (BLDC) or permanent magnet synchronous (PMS) motor versions. They are available in four frame sizes: AZ 84, AZ 108, AZ 150 and AZ 220. Torque from 1,5 Nm to 45 Nm / from 1.0 Ft-Lb to 30 Ft-Lb Efficiency all motors exceed IE4 Super-Premium efficiency class / efficiency up to 95% Speed variable nominal speeds Supply voltage 208-240 VAC, 380-480 VAC Nr. of poles and phases 10-pole, three-phase motors Dust and humidity protection IP54 or IP65 (with additional sealing) Ambient temperature between -40 °C and +50 °C * / between -40 °F and +120 °F * Insulation class F Temperature rise class B Corrosion protection C4 - high Mounting B14 Assembly in Slovenia (European Union); ISO 9001, ISO 14001 and ISO/TS 16949 certified Agency CE® marked, UL® recognized EC motors require a motor controller and cannot be run directly off the mains AC power supply.
  • 7. 7 MOTOR SIZE AZ 84 Motor Type Nominal torque Dimensions A Weight [Nm] [Ft-Lb] [mm] [in] [kg] [lbs] AZ 84-50 3,0 2.2 140,7 5.54 5,1 11.2 AZ 84-50 with additional cooling 3,0 2.2 164 6.46 5,3 11.7 Weight may vary due to construction differences and different electrical data between the motors. AZ 84 AZ 84 with additional cooling Motor Motor current Nominal torque Nominal speed Motor poles BackEMF Resistance Rs Inductance Ld [A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH] AZ 84-50-S070A 3,0 3,0 2.2 4500 10 68 1,94 7,2 Legend: Motor current: Nominal motor current per line Nominal torque: Design torque of the motor Nominal speed: Design speed of the motor Motor poles: Number of motor poles BackEMF: RMS value of Back EMF at 1000 rpm, line to line Ld: Inductance at d-axis position, line to star-point Rs: Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
  • 8. 8 MOTOR SIZE AZ 108 Weight may vary due to construction differences and different electrical data between the motors. Motor Type Nominal torque Dimensions Weight A B C D [Nm] [Ft-Lb] [mm] [in] [mm] [in] [mm] [in] Thread [kg] [lbs] AZ 108-30 3,5 2.5 136,5 5.37 ø95 ø3.74 ø115 ø4.53 M8 5,7 12.6 ø80 ø3.15 ø100 ø3.94 M6 AZ 108-30 with additional cooling 3,5 2.5 167,8 6.61 ø95 ø3.74 ø115 ø4.53 M8 6,3 13.9 ø80 ø3.15 ø100 ø3.94 M6 AZ 108-55 5,5 4.0 161,5 6.36 ø95 ø3.74 ø115 ø4.53 M8 7,6 16.8 ø80 ø3.15 ø100 ø3.94 M6 AZ 108-55 with additional cooling 5,5 4.0 192,8 7.59 ø95 ø3.74 ø115 ø4.53 M8 8,3 18.3 ø80 ø3.15 ø100 ø3.94 M6 AZ 108 AZ 108 with additional cooling Motor Motor current Nominal torque Nominal speed Motor poles BackEMF Resistance Rs Inductance Ld [A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH] AZ 108-30-S090A 3,0 3,0 2.2 4500 10 67 1,35 11,0 AZ 108-30-S120A 2,3 3,0 2.2 3400 10 88 2,14 21,4 AZ 108-55-S060A 4,2 5,0 3.7 3800 10 79 0,91 8,0 AZ 108-55-S075A 3,5 5,0 3.7 3100 10 96 1,38 13,1 Legend: Motor current: Nominal motor current per line Nominal torque: Design torque of the motor Nominal speed: Design speed of the motor Motor poles: Number of motor poles BackEMF: RMS value of Back EMF at 1000 rpm, line to line Ld: Inductance at d-axis position, line to star-point Rs: Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
  • 9. 9 Motor Motor current Nominal torque Nominal speed Motor poles BackEMF Resistance Rs Inductance Ld [A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH] AZ 150-45-S090A 4,0 7,5 5.5 2250 10 126 0,98 19,8 AZ 150-70-S070A 5,1 11,5 8.5 1900 10 150 0,77 16,3 AZ 150-70-D070A 8,4 11,0 8.1 3200 10 87 0,26 5,4 Legend: Motor current: Nominal motor current per line Nominal torque: Design torque of the motor Nominal speed: Design speed of the motor Motor poles: Number of motor poles BackEMF: RMS value of Back EMF at 1000 rpm, line to line Ld: Inductance at d-axis position, line to star-point Rs: Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range. MOTOR SIZE AZ 150 Weight may vary due to construction differences and different electrical data between the motors. Motor Type Nominal torque Dimension A Weight [Nm] [Ft-Lb] [mm] [in] [kg] [lbs] AZ 150-45 8 6 147 5.79 11,3 24.9 AZ 150-45 with additional cooling 8 6 188 7.40 12,0 26.5 AZ 150-70 13 9.5 172 6.77 14,7 32.4 AZ 150-70 with additional cooling 13 9.5 213 8.39 15,4 34.0 AZ 150-100 18 13 202 7.95 20,7 45.6 AZ 150-100 with additional cooling 18 13 202 7.95 20,7 45.6 AZ 150 AZ 150 with additional cooling
  • 10. 10 MOTOR SIZE AZ 220 Weight may vary due to construction differences and different electrical data between the motors. Motor Type Nominal torque Dimension A Weight [Nm] [Ft-Lb] [mm] [in] [kg] [lbs] AZ 220-55 24 17 172 6.77 27,0 59.5 AZ 220-55 with additional cooling 24 17 227,3 8.95 27,9 61.5 AZ 220-100 45 30 217 8.54 39,5 87.1 AZ 220-100 with additional cooling 45 30 272,3 10.72 40,6 89.5 AZ 220 AZ 220 with additional cooling Motor Motor current Nominal torque Nominal speed Motor poles BackEMF Resistance Rs Inductance Ld [A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH] AZ 220-55-D105A 9,3 22 16.2 1700 10 157 0,33 10,0 AZ 220-55-P172A 12,0 22 16.2 2050 10 122 0,18 6,7 AZ 220-100-P150A 14,2 40 29.5 1400 10 187 0,19 10,3 AZ 220-100-P120A 17,7 40 29.5 1750 10 150 0,15 6,6 Legend: Motor current: Nominal motor current per line Nominal torque: Design torque of the motor Nominal speed: Design speed of the motor Motor poles: Number of motor poles BackEMF: RMS value of Back EMF at 1000 rpm, line to line Ld: Inductance at d-axis position, line to star-point Rs: Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
  • 11. 11 NZ MOTORS OVERVIEW Features NZ motors are electronically commutaed (EC) motors which can cover higher torques than already well-known AZ motors. Efficiency of the motors has been improved on the entire operating area, even though keeping the use non-rare ferrite magnets. They are available in frame size: NZ 270. Torque from 45 Nm to 80 Nm / from 30 Ft-Lb to 60 Ft-Lb Efficiency all motors fulfil IE5 Ultra-Premium efficiency class / losses are more than 20% lower compared to IE4 Super-Premium motors Speed variable nominal speeds Supply voltage 208-240 VAC, 380-480 VAC Nr. of poles and phases 12-pole, three-phase motors Dust and humidity protection IP54 or IP65 (with additional sealing) Ambient temperature between -40 °C and +50 °C * / between -40 °F and +120 °F * Insulation class F Temperature rise class B Corrosion protection C4 - high Mounting B14 Assembly in Slovenia (European Union); ISO 9001, ISO 14001 and ISO/TS 16949 certified Agency CE® marked *Motors are available in two options – with or without additional cooling. Motors without additional cooling can only be used in applications where motor is mounted into the airstream. For all other applications motor needs to be temperature tested or additional cooling is needed. Highlights -- extremely high efficiency up to 96% -- very high efficiency throughout the entire operating area -- use of non-rare earth magnets (ferrite magnets) -- highest quality with long lifetime -- maintenance-free operation -- very low noise -- low weight -- compact design -- improved Return On Investment (ROI) -- compatible with all leading controller brands Applications -- axial fans -- plug fans -- centrifugal fans (backward or forward curved blades) -- mixed flow fans -- pumps -- compressors -- other EC motors require a motor controller and cannot be run directly off the mains AC power supply.
  • 12. 12 MOTOR SIZE NZ 270 Weight may vary due to construction differences and different electrical data between the motors. Motor Type Nominal torque Dimension A Weight [Nm] [Ft-Lb] [mm] [in] [kg] [lbs] NZ 270-80 55 40 256 10.08 37,5 82.7 NZ 270-80 with additional cooling 55 40 311,3 12.26 38,6 85.1 NZ 270-120 80 60 296 11.65 41,5 91.5 NZ 270-120 with additional cooling 80 60 351,3 13.83 42,6 93.5 NZ 270 NZ 270 with additional cooling Motor Motor current Nominal torque Nominal speed Motor poles BackEMF Resistance Rs Inductance Ld [A] [Nm] [Ft-Lb] [min-1] [V] [Ω] [mH] NZ270080S016 17,5 44 32.5 1680 12 173 0,36 4,5 NZ270120S012 23 65 48.0 1650 12 197 0,26 3,8 NZ270120S018 15,5 65 48.0 1100 12 295 0,59 8,4 Legend: Motor current: Nominal motor current per line Nominal torque: Design torque of the motor Nominal speed: Design speed of the motor Motor poles: Number of motor poles BackEMF: RMS value of Back EMF at 1000 rpm, line to line Ld: Inductance at d-axis position, line to star-point Rs: Resistance, line to star-pointNote: Presented speed is only an example. Motor can be optimized for any speed within the range.
  • 13. 13 Highlights -- customized to customer’s needs -- high efficiency -- long lifetime -- robust construction -- can be used in wide range of applications -- lower operating costs due to energy efficient solution Features CONTROLLERS OVERVIEW Compacto Invento S Output power (P2 ) up to 1,1 kW / up to 1.5 HP up to 5,5 kW / up to 7.5 HP Mains voltage 1x230 VAC ± 10%, 50/60 Hz 3x400 VAC ± 10%, 50/60 Hz Efficiency up to 95% up to 98% Speed variable nominal speeds, 10-100% continuously adjustable Dust and humidity protection IP55 Commutation sensorless Ambient temperature between -10 °C and +45 °C / between 14 °F and 113 °F Assembly in Slovenia (European Union) ISO 9001, ISO 14001 and ISO/TS 16949 certified Agency CE® marked EC motors are able to run only if connected to an EC controller. Domel offers two EC motor controller versions – Compacto and Invento S.
  • 14. 14 Functions -- Active PFC -- Speed control via external analogue signal 0-10 V -- Speed control via potentiometer -- Speed control via MODBUS -- Motor direction change via MODBUS -- Open Collector speed output – current speed of the motor can be displayed as: -- analogue value – voltage or current signal -- digital value – PWM or pulse signal -- Fault relay output -- DC voltage output +5 V, +24 V -- Start / Stop function -- Fire Mode safety function -- Internal PID regulator -- Analogue input for external sensor (temperature, CO2 , smoke sensor, etc.) -- Resonance avoidance function CONTROLLER COMPACTO Data above represents the performance of an average sample. Individual data may vary due to normal manufacturing variations. Controller Type Output power Output current Weight [kW] [HP] [A] [kg] [lbs] Compacto 08 0,80 1.0 4 A 4,2 9.3 Compacto 11 1,10 1.5 6 A 4,2 9.3
  • 15. 15 Functions -- Passive PFC -- Speed control via external analogue signal 0-10 V -- Speed control via potentiometer -- Speed control via MODBUS -- Motor direction change via MODBUS -- Open Collector speed output – current speed of the motor can be displayed as: -- analogue value – voltage or current signal -- digital value – PWM or pulse signal -- Fault relay output -- DC voltage output +10 V, +24 V -- Start / Stop function -- Fire Mode safety function -- Internal PID regulator -- Analogue input for external sensor (temperature, CO2 , smoke sensor, etc.) -- Resonance avoidance function CONTROLLER INVENTO S Data above represents the performance of an average sample. Individual data may vary due to normal manufacturing variations. Controller Type Output power Output current Weight [kW] [HP] [A] [kg] [lbs] Invento S15 1,5 2.0 3,7 5,5 12.1 Invento S22 2,2 3.0 5,3 5,5 12.1 Invento S30 3,0 4.0 7,2 6,2 13.7 Invento S40 4,0 5.5 9,1 6,5 14.3 Invento S55 5,5 7.5 12,0 7,2 15.9
  • 16. NOTES
  • 18. Domel, d.o.o. Otoki 21, 4228 Železniki, Slovenija Tel.: +386 (0)4 51 17 100, Fax: +386 (0)4 51 17 106 www.domel.com e-mail: info@domel.com