STAINES AP-PLANS PHDD C2-A0 HVAC MECH

  1. 150mm AV / DATA CABLE TRAY. TRUNKINGS RISE TO SOFFIT DB L 18CHANNEL 6A DIMMABLE POWER UNIT TIGER MODE TP-06-18 MODE REMOTE TIMER RT-00-10 2" GAS TO KITCHEN SOLENOID VALVE CONTROLLED BY MERLIN CT1200S GAS SAFETY SYSTEM 2" GAS SPLITS 1) RISES IN CEILING TO PLANTROOM 2)RISES TO GROUND CEILING TO KITCHEN 300MM CABLE TRAYS 15mm CWS 15mm CWS TO DISHWASHER DHW DROP FROM ABOVE 28mm FLOW DHW RISES TO ABOVE 15mm RETURN 2" GAS DROPS IN SERVICES COLUMN 5"EV 6L/S 15mmCWS RISES TO ABOVE 1050x360x1338 22mm CWS RISES TO SOFFIT 22mm DHW F&R RISE TO SOFFIT 28MM CWS IN CEILING WCs & BAR 28MM CWS IN CEILING VOID TO SERVE BOH 15mm CWS TO ICE MACHINES WC FAN 150mm / 66L/S@70Pa 5" EV 6L/S GROUND LEVEL 22mm CWS,22mmDHW F&15mmR, 2"DRAIN POP UP No.1 POP UP No.2 POP UP No.3 POP UP No.6 POP UP No.5 POP UP No.4 Soil Manifold Gradient = 1deg(18mm/m) Air admittance valve before last connection AIR ADMITTANCE VALE IT DB 14W SPN 2" GAS SOLENOID DRAIN MAJOR 400mmH DRAIN MAJOR 400mmH RETURN AIR LOUVER 1580 BAR WASTE 50MM SS Europipe VCD FA SG13 - PREP AREA FRESH AIR SUPPLY100L/s VCD FA SG14 - PREP AREA FRESH AIR SUPPLY 100L/s 2" DRAINMAJOR DISCHARGE PIPES 403 302 690 82mm BLUCHER 50mm BLUCHER 50mm BLUCHER FA SG15 - WASHUP AREA FRESH AIR SUPPLY250L/s EG14 - 220L/s EG13 - 220L/s FA SG16 - SUPPLY 250L/s POP UP No.1 POP UP No.2 POP UP No.3 POP UP No.6 POP UP No.5 POP UP No.4 CLEANERS' SINK E E E E E E E E E E 2820(STAINLESSGANTRY) 3235 (STAINLESS GANTRY) 800 4235 (STAINLESS GANTRY) 400 400 2920(TIMBERBULKHEAD) 7920 (STAINLESS GANTRY) 8020 (TIMBER BULKHEAD) 500 400 8020 (TIMBER BULKHEAD) 450 2820(STAINLESSGANTRY) 2920(TIMBERBULKHEAD) 400 500 400 500 400 500 GAS METER TEAM ROOM 300L DHW CALORIFIER 2046mmH C13 TYPE FLUES 5" EV 6L/S 5" EV 6L/S MITSUBISHI (20.25kW) 40mm DRAIN DROPS TO POP UP NO3 BELOW WC FAN 100MM / 12L/S@30Pa C13 TYPE FLUES DHW DROP TO BELOW 28mm FLOW DHW RISES FROM BELOW 15mm RETURN 15mmCWS RISES TO ABOVE MEZZANINE LEVEL 3000.0000 3850.0000 3 X MITSUBISHI PUHZ-P250YHA3 FAN COIL CONDENSERS MITSUBISHI (20.25kW) FREEZER LPHC068 16ATPN CHILLER MPHC026 16ATPN CELLAR MPHC034 20ATPN LPHW EXPANSION VESSEL LOWLOSS HEADER 8-AC-0.195m3/S 14-AC-0.18m3/S 5-AC-0.195m3/S 6-AC-0.195m3/S 15-AC-0.195m3/S 17-AC-0.195m3/S18-AC-0.195m3/S 16-FA-0.144m3/S 800x800mm KITCHEN EXTRACT DUCT DISCHARGE NOZZLE 0.55m2 / 15m/s. DUCT RUNS VERTICAL TO 1m ABOVE PARAPIT SUPPLY AIR CONNECTIONS DUCT RISES TO MEZZ LEVEL AND ENTERS PLANTROOM 0.88m3/s0.88m3/s 0.88m3/s 0.88m3/s 0.76m3/s 0.76m3/s 0.76m3/s VCD F/D F/D 12-AC-0.18m3/S 11-AC-0.18m3/S 2-AC-0.195m3/S 3-AC-0.195m3/S 20-AC-0.195m3/S21-AC-0.195m3/S22-FA-0.144m3/S 19-FA-0.144m3/S 1-FA-0.144m3/S 4-FA-0.144m3/S 1.12m3/s 1.12m3/s 7-FA-0.144m3/S SUPPLY DUCTS RISES TO HL AND RUNS ALONG SOFFIT 0.76m3/s 0.76m3/s 0.76m3/s 800Wx400H 1000X400 VCD VCD VCD 1000Wx400H - 2416L/s@6m/s KITCHEN SUPPLY SET UP OVER EXTRACT AIRTEMPERINGCONDENSER 20KW.1540X900X320 AIRTEMPERINGCONDENSER 20KW.1540X900X320 AIRTEMPERINGCONDENSER 20KW.1540X900X320 2" GAS SOLENOID SYSTEM PUMP MAGNA3 D40-100F GLYCOL UNIT 13A SPN GLYCOL UNIT 13A SPN GLYCOL UNIT 13A SPN GLYCOL UNIT 13A SPN 22mm CWS FOR COKE VCD IT CONDENSERS 23-RETURNAIR 500 1200Wx600H 5.8m3/s@8m/s 1200Wx600H 8m/s 1200Wx600H 8m/s TRANSITION 1100 x 800H TO 800 x 500H 800x500H 9504m3/hR 6m/s WASHUP/ICE MACHINE EXTRACT 0.64m3/S PREP AREA FRESH AIR SUPPLY150L/s 654 614 700 1004 754 548 596 793 377 POP UP No.1 RELIEF VALVE PIPEWORK RATED TO 110degC 50mm BLUCHER 50mm BLUCHER WASHUPSUPPLY 0.25m3/S FA SG11 - SUPPLY 24L/s 2 PERSON BANQUETTE SEATS x 11 = 22 No. COVERS TOTAL RESTAURANT DINING COVERS = 248 No. COVERS 6 & OVER 58 No. COVERS 23% 4 & 5 144 No. COVERS 58% 2 46 No. COVERS 19% WITH 'ZONE A' CLOSED = 226 No. COVERS WITH 'ZONE B' CLOSED = 228 No. COVERS WITH 'ZONES A & B' CLOSED = 206 No. COVERS PINK DOTTED LINE INDICATES WALL TO BE TAKEN FULL HEIGHT - 6500mm SEALS ELECTRICS ALL ELECTRICAL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH PHDD DRAWINGS FIRE ALARM SYSTEM THE PROPOSED FIRE ALARM WILL BE INSTALLED TO BS 5839 : PART 1 : 2002 TO L2 STANDARD. THIS WILL BE CONNECTED TO THE LANDLORD'S SYSTEM IN ACCORDANCE WITH THEIR INSTRUCTION. SMOKE DETECTION TO CEILING VOIDS TO BE INCLUDED EMERGENCY LIGHTING EMERGENCY LIGHTING SYSTEM TO BE PROVIDED IN ACCORDANCE WITH BS 5266 : PART 1 : 2005 FIRE STOPPING FIRE STOPPING TO BE INSERTED INTO CEILING AS REQUIRED. ALL DUCTWORK PASSING THROUGH COMPARTMENT FLOORS AND WALLS TO BE PROTECTED BY FIRE COLLARS NOTICES NOTICES WITH THE WORDS 'PUSH BAR TO OPEN' TO BE DISPLAYED ON ALL DOORS FITTED WITH PANIC BOLTS ALL FIRE RESISTING SELF CLOSING DOORS TO BE PERMANENTLY MARKED ON EACH SIDE AT EYE LEVEL WITH A BLUE CIRCULAR NOTICE BEARING THE WORDS 'FIRE DOOR - KEEP SHUT' IN WHICH LETTERS ARE NOT TO BE LESS THAN 5mm IN HEIGHT PLANT ROOM TEAM ROOM OFFICE STORE 800x800mm KITCHEN EXTRACT DUCT E E STORE FA-0.576m3/S 34-FA-0.266m3/S 500 x 200 BELLMOUTH 30-AC-0.22m3/S 25-AC-0.22m3/S 29-AC-0.22m3/S 26-AC-0.22m3/S 28-AC-0.22m3/S 27-AC-0.22m3/S MULTI-CONE DIFFUSERS C/W TWIN BLADE TYPE (R) DAMPER 3No: 450 X 200 DOUBLE DEFLECTION SIDE WALL GRILLE. 31-FA- 0.19m3s 32-FA- 0.19m3s 500 30mm external Mezz flanges on MMF casing. 30mm external Mezz flanges on MMF casing. Side Elevation of ESPs, UVO and MMF PUHZ-P250YHA3 PUHZ-P250YHA3 PUHZ-P250YHA3 PEA-RP250GAQ PEA-RP250GAQ PEA-RP250GAQ 300L EXPANSION VESSEL MIKROFILL SOLENOID VALVE FUSIBLE LINK DHW SCHEMATIC GAS CWS 2" 11 2" 11 2"1" 1"11 2" 11 4" 11 4" 1" 1" MULTI-CONE DIFFUSERS C/W TWIN BLADE TYPE (R) DAMPER 3No: 450 X 200 DOUBLE DEFLECTION SIDE WALL GRILLE. 500 x 200 BELLMOUTH HVAC TGI FRIDAYS STAINES C2 1of1 1:50@A019/10/2015NJH Project PH Design & Deliver Ltd, Park Holland Building Sampson Street, Stoke on Trent, ST1 5EZPHDD
Anzeige