fuel-consumption-measurement-system.pptx

fuel-consumption-measurement-system.pptx
fuel-consumption-measurement-system.pptx
This PC based Data Acquisition & Control Software is meant for conducting collapse test of
Test Filter. It provides the facility to monitor the input/ output parameters such as
Differential Pressure, Flow Rate etc. The solution involves a Data Acquisition, Feedback &
Control system that interfaces with Pressure, Temperature, Flow Sensors, Solenoid Valves,
Level Sensors & the AC drive.
fuel-consumption-measurement-system.pptx
 Filter Clogging Indicator Switch (6.0) which indicates that the Filter is clogged
 Tank Weighing System comprising of 4 Load Cells, Flameproof Junction Box & IND 570
Indicator
 Temperature Sensors installed to monitor the temperature of chilled water as well as the
fuel.
 Ball Valve at the suction of the Fuel Tank Filling Pump is MANUAL and has a limit switch
which tells that this Valve is Open
 Float Switches get activated in case of Fuel Tank overfill or Fuel Tank over flow
 PLC Controller is connected with Temperature Sensors, Limit Switches on Valves and
Filter Clogging Indicator Switches on filters and also Float Switched.
 PLC Controller is also connected with Chiller through RS485
 The HMI on control panel will always show the current status (Open/Close, On/Off) of all
components in the Fuel Circuit.
fuel-consumption-measurement-system.pptx
• Flame Proof ELECTRIC MOTOR : 1.5KW, 1440 RPM,Three PHASE, 4 POLE, 50HZ
• Fuel Filter: Filtration :10 Micron(absolute), with electronic Clogging Indicator.
• Fuel tank(material ss-304): 150 ltr fuel tank
• Temperature sensor (rtd): range: 0 to 100 degree c
• Shell & Tube Type Heat Exchanger: Fuel Line Pressure Drop 0.01 Bar.
• Refregirated water chiller : Three phase refrigerated air cooled chiller
• Ms Sheet Metal Box For Control Panel: 600h X 600w X 350d (Sheet Metal Enclosure With
600x600x350 Mm
• Power Supply: 220/4.2a,24v,Dc
• Panel Light: Panel Light
fuel-consumption-measurement-system.pptx
Application
This PC based Data Acquisition & Control Software is meant for testing of Life and
Efficiency of the Test Filter. It provides the facility to monitor the input/ output parameters
such as Differential Pressure, Flow Rate, Temperature etc. The solution involves a Data
Acquisition, Feedback & Control system that interfaces with Pressure, Temperature, Flow
Sensors, On/Off Valves, Level Sensors, AC drives.
fuel-consumption-measurement-system.pptx
Thank You
1 von 11

Más contenido relacionado

Similar a fuel-consumption-measurement-system.pptx(20)

BioreactorBioreactor
Bioreactor
Edgard Gomez Valverde88 views
_AssetScan__AssetScan_
_AssetScan_
Dan Yarmoluk169 views
Separatore pa 605Separatore pa 605
Separatore pa 605
MohamedLamfouad165 views
Process control lab manualProcess control lab manual
Process control lab manual
SUVOBROTO BANERJEE5.3K views
InstrumentationInstrumentation
Instrumentation
Maria Romina Angustia1.6K views
Lectures-CLL361.pdfLectures-CLL361.pdf
Lectures-CLL361.pdf
ssuser4355cc9 views
HVAC, Heating Ventilation Air Conditioning BMSHVAC, Heating Ventilation Air Conditioning BMS
HVAC, Heating Ventilation Air Conditioning BMS
Mohammad Azam Khan5.9K views
Digital Temperature ControllersDigital Temperature Controllers
Digital Temperature Controllers
Dwyer Instruments1K views
Multi-range-pocket-TDS-testerMulti-range-pocket-TDS-tester
Multi-range-pocket-TDS-tester
kimberlabtronuk2 views
Chapter 55 Computer SensorsChapter 55 Computer Sensors
Chapter 55 Computer Sensors
mcfalltj3.3K views
Innovations - Ability 11.02.14Innovations - Ability 11.02.14
Innovations - Ability 11.02.14
Overbury850 views
Session 24 - Control SystemsSession 24 - Control Systems
Session 24 - Control Systems
VidyaIA360 views
Flashar 2014 by ATACFlashar 2014 by ATAC
Flashar 2014 by ATAC
European Tech Serv83 views
Hydraulic power pack and actuator systemHydraulic power pack and actuator system
Hydraulic power pack and actuator system
Neometrix_Engineering_Pvt_Ltd847 views

Más de Neometrix_Engineering_Pvt_Ltd(20)

Six Clamp Perfect Binding MachineSix Clamp Perfect Binding Machine
Six Clamp Perfect Binding Machine
Neometrix_Engineering_Pvt_Ltd24 views
oil-flooded-screw-compressor-test-rig.pptxoil-flooded-screw-compressor-test-rig.pptx
oil-flooded-screw-compressor-test-rig.pptx
Neometrix_Engineering_Pvt_Ltd24 views
Hydraulic Control Valve Test Bench.pptxHydraulic Control Valve Test Bench.pptx
Hydraulic Control Valve Test Bench.pptx
Neometrix_Engineering_Pvt_Ltd51 views
head-impact-test-rig.pptxhead-impact-test-rig.pptx
head-impact-test-rig.pptx
Neometrix_Engineering_Pvt_Ltd8 views
halon-reclaimation-and-refiling-facility.pptxhalon-reclaimation-and-refiling-facility.pptx
halon-reclaimation-and-refiling-facility.pptx
Neometrix_Engineering_Pvt_Ltd30 views
impulse-and-load-test-rig.pptximpulse-and-load-test-rig.pptx
impulse-and-load-test-rig.pptx
Neometrix_Engineering_Pvt_Ltd69 views
Fuel Injection Pump Test BenchFuel Injection Pump Test Bench
Fuel Injection Pump Test Bench
Neometrix_Engineering_Pvt_Ltd116 views
dual-hydraulic-test-system.pptxdual-hydraulic-test-system.pptx
dual-hydraulic-test-system.pptx
Neometrix_Engineering_Pvt_Ltd26 views
Doppler-Vor-Test-Rack.pptxDoppler-Vor-Test-Rack.pptx
Doppler-Vor-Test-Rack.pptx
Neometrix_Engineering_Pvt_Ltd19 views
Oxygen charging and distribution vehicle-UGSSO2Oxygen charging and distribution vehicle-UGSSO2
Oxygen charging and distribution vehicle-UGSSO2
Neometrix_Engineering_Pvt_Ltd59 views
chemical-cleaning-bay.pptxchemical-cleaning-bay.pptx
chemical-cleaning-bay.pptx
Neometrix_Engineering_Pvt_Ltd20 views
ccb-burn-test-rig.pptxccb-burn-test-rig.pptx
ccb-burn-test-rig.pptx
Neometrix_Engineering_Pvt_Ltd5 views
Automated Inverter Test Rig On Labview Environment.pptxAutomated Inverter Test Rig On Labview Environment.pptx
Automated Inverter Test Rig On Labview Environment.pptx
Neometrix_Engineering_Pvt_Ltd37 views
Argon Heating and Cooling System.pptxArgon Heating and Cooling System.pptx
Argon Heating and Cooling System.pptx
Neometrix_Engineering_Pvt_Ltd16 views
Advance Valve-pressurepac-900 Bar.pptxAdvance Valve-pressurepac-900 Bar.pptx
Advance Valve-pressurepac-900 Bar.pptx
Neometrix_Engineering_Pvt_Ltd22 views
Pneumatic Test RigPneumatic Test Rig
Pneumatic Test Rig
Neometrix_Engineering_Pvt_Ltd81 views
HYDRAULIC POWER PACK 230LPM/210 BARHYDRAULIC POWER PACK 230LPM/210 BAR
HYDRAULIC POWER PACK 230LPM/210 BAR
Neometrix_Engineering_Pvt_Ltd75 views

Último(20)

Object Oriented Programming with JAVAObject Oriented Programming with JAVA
Object Oriented Programming with JAVA
Demian Antony D'Mello58 views
What is Unit TestingWhat is Unit Testing
What is Unit Testing
Sadaaki Emura21 views
Dynamics of Hard-Magnetic Soft MaterialsDynamics of Hard-Magnetic Soft Materials
Dynamics of Hard-Magnetic Soft Materials
Shivendra Nandan13 views
performance uploading.pptxperformance uploading.pptx
performance uploading.pptx
SanthiS107 views
Activated sludge process .pdfActivated sludge process .pdf
Activated sludge process .pdf
8832RafiyaAltaf6 views
String.pptxString.pptx
String.pptx
Ananthi Palanisamy47 views
CHI-SQUARE ( χ2) TESTS.pptxCHI-SQUARE ( χ2) TESTS.pptx
CHI-SQUARE ( χ2) TESTS.pptx
ssusera597c514 views
SNMPxSNMPx
SNMPx
Amatullahbutt12 views
Solar PVSolar PV
Solar PV
Iwiss Tools Co.,Ltd11 views
LFA-NPG-Paper.pdfLFA-NPG-Paper.pdf
LFA-NPG-Paper.pdf
harinsrikanth40 views
Pointers.pptxPointers.pptx
Pointers.pptx
Ananthi Palanisamy62 views
IWISS Catalog 2022IWISS Catalog 2022
IWISS Catalog 2022
Iwiss Tools Co.,Ltd23 views
Codes and Conventions.pptxCodes and Conventions.pptx
Codes and Conventions.pptx
IsabellaGraceAnkers6 views
What is Whirling Hygrometer.pdfWhat is Whirling Hygrometer.pdf
What is Whirling Hygrometer.pdf
IIT KHARAGPUR 10 views

fuel-consumption-measurement-system.pptx

  • 3. This PC based Data Acquisition & Control Software is meant for conducting collapse test of Test Filter. It provides the facility to monitor the input/ output parameters such as Differential Pressure, Flow Rate etc. The solution involves a Data Acquisition, Feedback & Control system that interfaces with Pressure, Temperature, Flow Sensors, Solenoid Valves, Level Sensors & the AC drive.
  • 5.  Filter Clogging Indicator Switch (6.0) which indicates that the Filter is clogged  Tank Weighing System comprising of 4 Load Cells, Flameproof Junction Box & IND 570 Indicator  Temperature Sensors installed to monitor the temperature of chilled water as well as the fuel.  Ball Valve at the suction of the Fuel Tank Filling Pump is MANUAL and has a limit switch which tells that this Valve is Open  Float Switches get activated in case of Fuel Tank overfill or Fuel Tank over flow  PLC Controller is connected with Temperature Sensors, Limit Switches on Valves and Filter Clogging Indicator Switches on filters and also Float Switched.  PLC Controller is also connected with Chiller through RS485  The HMI on control panel will always show the current status (Open/Close, On/Off) of all components in the Fuel Circuit.
  • 7. • Flame Proof ELECTRIC MOTOR : 1.5KW, 1440 RPM,Three PHASE, 4 POLE, 50HZ • Fuel Filter: Filtration :10 Micron(absolute), with electronic Clogging Indicator. • Fuel tank(material ss-304): 150 ltr fuel tank • Temperature sensor (rtd): range: 0 to 100 degree c • Shell & Tube Type Heat Exchanger: Fuel Line Pressure Drop 0.01 Bar. • Refregirated water chiller : Three phase refrigerated air cooled chiller • Ms Sheet Metal Box For Control Panel: 600h X 600w X 350d (Sheet Metal Enclosure With 600x600x350 Mm • Power Supply: 220/4.2a,24v,Dc • Panel Light: Panel Light
  • 9. Application This PC based Data Acquisition & Control Software is meant for testing of Life and Efficiency of the Test Filter. It provides the facility to monitor the input/ output parameters such as Differential Pressure, Flow Rate, Temperature etc. The solution involves a Data Acquisition, Feedback & Control system that interfaces with Pressure, Temperature, Flow Sensors, On/Off Valves, Level Sensors, AC drives.