1. Photochem
Colorimeters
Principle :
Light from a broad spectrum LED is focused through an unique
optical system a filter test tube to the photocell. Output from the
photocell is fed into an amplifier and the output of the amplifier
to the Digital Panel Meter (DPM).
A set of filters, enabling a wide range of range of analytical
tests, are mounted on a turret so that the required filter can
easily be selected.
The operation of the unit is very simple, the user needs to adjust
display 0.00 OD or 100% T with blank and then take the reading
of the identified standard / sample withAuto Zero facility.
The microprocessor based unit when opted for, provides
multiple facilities within the same compact size with Auto
Zero facility.
Salient Features :
•
•
•
•
•
Small convenient, sample size of 1 ml only
Long life broad spectrum LED light source
Very few controls for ease of operation
Compact design
Available various digital models:
Photochem 8 filter, Photochem 8 filter mains/battery, OD only
with Auto Zero
Microprocessor based Photochem 8 filter with Auto Zero
facility/OD/T/C.
Applications :
•
•
•
•
•
•
•
Biochemistry
Clinical Laboratory
Pathology
Clinical Pathology
Water Analysis
Soil Analysis
Metallurgy
Photochem 8
Microprocessor Auto Zero
Photochem Micro 8
Auto Zero
2. Aimil/A&I/PEI-PC/14-15/01/02MarComCreation
For further information, please contact us :
Corporate Office :
"Naimex House"
A-8, Mohan Co-operative
Industrial Estate, Mathura Road,
New Delhi-110044
E-mail : info@aimil.com
Also Offices at :
• Mumbai • Bengaluru • Kolkata • Chennai
• Vadodara • Hyderabad • Chandigarh
• Guwahati • Nagpur • Bhubaneswar • Indore
Resident Representatives :
• Kochi • Lucknow
www.aimil.comsalespei@aimil.com91-11-2695 001191-11-30810200/45/46
Due to Aimil's policy of continuous development, specifications are subject to change without prior notice.
Cat No. Eight Filter Models
018000 Auto Zero Digital Micro Photochem 8 Filter with optical density scale only withAuto Zero.
018100Auto Zero Digital Microprocessor based Photochem 8 Filter withAuto Zero, %T, OD,
Concentration scales.
018200 Auto Zero Digital Micro Photochem 8 Filter with mains / battery operation with built in
Ni-Cad rechargeable batteries with optical density scale only withAuto Zero.
Digital Micro 8 Filter with Auto Zero
Digital Micro 8 Filters battery model
with Auto Zero
Digital Microprocessor 8 Filter Auto Zero
%Transmission Optical Density, Concentration
Peak transmission wavelengths
Detector
Lamp source
Lamp source regulation
Filters
Power requirements
Dimensions
Nett weight for micro models
Bright 7 segment LED display Optical Density -
0.20 t0 1.99
Bright 7 segment LED display Optical Density -
0.20 to 1.99 Built in Ni-Cad rechargeable battery
pack with automatic changeover from mains to
battery with suitable indicators
Bright 7 segment LED display, Displays function
and the reading associated with function
selected displays
%T : 0 to 130
OD : -0.11 to 1.99
C1 : 000 to 999
C2 : 00.0 to 99.9
Last used "K" factor retained in memory even
after power "OFF"
430, 470, 490, 520, 550, 580, 610 and 700nm
Sealed high sensitivity silicon photocell
Long life, broad spectrum LED
Fully stabilized. Deviation not more than ± 1% of
100% T. For mains variation between 190 to 250
V, 50 Hz
Hermetically sealed gelatin filters covering
visible spectrum
Approximately 5 Watts At 220V / 50 Hz
25 x 19 x 10 cm
1.5 Kg
All Eight Filter Models
Specifications:
Ordering Information