Clean	Energy	Corp
Origins
• The	request	for	extension	work	
• Ben	Weil	directed	his	assistance	towards	municipal	buildings	
• Assisted	over	...
Why	We’re	the	Best
• Students	couple	prior	in	class	and	in	field		experience	surrounding	
anything	building	science	relate...
Shelbourne	Falls	Overview
-Cowell	Gym	accounts	for	23%	of	municipal	energy	
use	
-Is	twice	as	energy	intensive	as	other	gy...
Shelbourne	Falls	Analysis
-High	rate	of	air	leakage:	stack	designed	for	no	to	
lots	of	ventilation	requirement	changes.	Ai...
Shelbourne	Falls	Solutions	and	Payback
Limitations	and	areas	for	improvement
• Time	limited	to	one	semester	
• One	site	visit		
• Missing	energy	usage	data	
• Fu...
Simon Pereira MAS2019
Simon Pereira MAS2019
Simon Pereira MAS2019
Simon Pereira MAS2019
Simon Pereira MAS2019
Nächste SlideShare
Wird geladen in …5
×

Simon Pereira MAS2019

34 Aufrufe

Veröffentlicht am

Presentation for the Sustainable Communities and Campuses Conference on March 29, 2019 in Cambridge, MA

Veröffentlicht in: Umweltschutz
  • Als Erste(r) kommentieren

  • Gehören Sie zu den Ersten, denen das gefällt!

Simon Pereira MAS2019

  1. 1. 
 Clean Energy Corp
  2. 2. Origins • The request for extension work • Ben Weil directed his assistance towards municipal buildings • Assisted over 20 communities and counting, about 7 each semester
  3. 3. Why We’re the Best • Students couple prior in class and in field experience surrounding anything building science related: structure, materials, renewable technologies, HVAC, and cost estimating. • Students with a range of backgrounds in building construction technology, architecture, sustainability science, and more! • Our suggestions are put to good use.
  4. 4. Shelbourne Falls Overview -Cowell Gym accounts for 23% of municipal energy use -Is twice as energy intensive as other gymnasiums -Temperature setpoint is 58 degrees, and gym is not used very often -->Should not be using this much energy Design: Gym area has two large stacks for ventilation and the basement is a half below grade and suffering from moisture and mold Major problems identified: high rate of air leakage, lack of insulation, steam heating system, thermostat settings, thermal stratification, and condensation on basement surfaces Thermographic image of steam radiator inside stack
  5. 5. Shelbourne Falls Analysis -High rate of air leakage: stack designed for no to lots of ventilation requirement changes. Air exfiltration via stacks is the assumed air leakage Heat loss estimation is about 279 MMBtu (approx. $5,023) per year. -Thermal Stratification: Operating 6 ineffective fans, which use about 1577 kWh/year, or about $237. -Moisture and mold in basement: stack bringing in 28 lbs of water in each hour from May to October, constant dehumidifier operation would amount to 11,849 kWh or about $1777 per year. To stop mold and moisture reducing uncontrolled air infiltration, assuring a vapor barrier between the ground and the basement space, and insulating the walls and floor such that they remain above dew point. Stratification in gym
  6. 6. Shelbourne Falls Solutions and Payback
  7. 7. Limitations and areas for improvement • Time limited to one semester • One site visit • Missing energy usage data • Further specifications needed by contractors

×