OILFILLED.pdf

  1. CompanyProfile EHV Oil Filled Cable & Accessories IntroductionofOilFilledCable EHV Oil Filled Cable & Accessories OilDuct Conductor ConductorShieldingLayer KraftPaperInsulation InsulationShieldingLayer CorrugatedAluminumSheath PEorPVCOver-Sheath OilDuct Conductor ConductorShieldingLayer KraftPaperInsulation InsulationShieldingLayer LeadAlloySheath MetallicTapeReinforceLayer PEorPVCOver-Sheath Corrugated Aluminum Sheath Cable Lead Alloy Sheath Cable Having led the establishment of the nation’s power network for the half-century, TAIHAN has led the development of extra high voltage cables since the 1970s and been recognized for the world class technology in Oil Filled underground cable. We have continued to develop its technology to 275kV and 400kV Oil Filled cables through advancement of technology and facilities. In step with the ever increasing power consumption and the expansion of extra high voltage cable demand, we reinforced the production capacity by equipping the 125 meters high VCV Tower, to produce high quality extra high voltage Oil Filled cable up to 500kV grade. Furthermore, we produce and supply quality accessories and joints materials for extra high voltage cables. From raw materials, production process, testing of products, to network design & installation, we have strictly controlled the quality of products and elevated ourselves to an extra high voltage cable specialist trusted by the world’s major markets. Through incessant research and development, the excellent functions of Oil Filled cable have been improved since 1900s. Among the many excellent characteristics, some typical ones can be listed as follows. 1_Novoidwithininsulationandstableelectrically The insulation oil, whose air bubbles and humidity are sufficiently removed by performing degassing treatment, is impregnated in insulating paper layer which is fully dried under high vacuum beforehand and kept under high degree of vacuum, and the cable is made accordingly. Since definitely positive pressure is always kept inside of the finished cable, there is absolutely no void in the cable insulation. 2_Operatingpotentialgradientcanbelarge Since no deterioration takes place in voids in the insulation by ionization as in the case with the solid-type cable, the operating potential gradient can be large. Therefore, the insulation thickness can be selected as thinn. 3_Expansionandcontractionofinsulationoilduetotemperaturechangecanbecompensatedbytheoiltanks Expansion and contraction of insulating oil, due to change of load under use or due to change of the external temperature can be fully compensated by the oil tank installed in a suitable position on the cable route. Therefore, there can be no void in the insulation. 4_Cableself-monitoring The inside of the cable is always kept at positive oil pressure so that no humidity intrudes from the outside in case damage occurs in the cable sheath, or in the joint box. Further, in case of the insulating oil leaks, the trouble is detected earlier as the alarm device actuates and it is possible to repair before occurrence of full-scale trouble in the cable system. 2 Taihan Electric Wire StructureofOilFilledCable
  2. ConstructionDate Copper Conductor 66kV ~ 400kV EHV Oil Filled Cable & Accessories ※ C.C : Circular Compacted H.C : Hollow Compacted S.H : Segmental Hollow Voltage 66 110 110 132 132 150 154 154 154 161 161 230 230 230 230 275 275 275 275 275 345 345 345 400 Approx. Dia.of Conductor Shield [mm] 43.12 27.02 33.7 36.02 41.61 39.62 36.12 47.32 59.02 52.4 59.42 36.96 44.76 59.06 65.86 33.96 45.06 54.06 59.26 65.76 36.36 48.56 59.86 66.56 Thick.of Insulation 7.1 10.0 10.2 10.35 10.35 14.22 11.88 12.83 12.83 13.5 13.5 20.3 20.3 20.3 20.3 19.9 19.8 19.8 19.8 19.8 22.9 22.9 22.56 25.0 Conductor Nominal Area [mm2 ] Shape 1000 300 400 630 900 800 600 1200 2000 1500 2000 630 1000 2000 2500 500 1000 1600 2000 2500 600 1200 2000 2500 H.C H.C H.C H.C H.C H.C H.C S.H S.H S.H S.H H.C S.H S.H S.H H.C S.H S.H S.H S.H H.C S.H S.H S.H CorrugatedALSheathType Cu/Kraft(orPPLP)/CAS/PVC[PE] Thick.of Metallic sheath Thick.of Jacket 2.0 - - 2.7 2.5 - 1.9 2.2 2.4 2.3 2.41 2.7 2.7 2.7 2.8 2.7 - - 2.7 2.8 2.3 2.5 2.7 3.0 4.5 - - 4.5 4.5 - 6.0 4.5 4.5 4.5 4.5 5.5 5.5 5.5 5.5 6 - - 8 4 6 6 6 5.5 OverallDia. Approx. Weight [ton] 80.84 - - 84.4 88.7 - 78.3 89.1 113.1 107.1 114.46 109.68 117.44 131.84 139.19 105.73 - - 135.25 156.7 112.46 125.8 137.7 151.5 14.7 - - 12.0 14.9 - 12.6 19.5 29.0 23.2 28.4 16.8 14.9 32.8 40.3 16.5 - - 34.2 40.7 18.6 26.6 35.9 42.5 LeadSheathType Cu/Kraft(orPPLP)/LEAD/PVC[PE] Thick.of Metallic sheath Thick.of Jacket - 2.7 2.8 - - 3.55 - - - - - - - - - - 3.8 4.3 - - - - - - - 4.0 3.7 - - 4.2 - - - - - - - - - - 5.0 5.0 - - - - - - OverallDia. Approx. Weight [ton] - 64.26 70.76 - - 98.12 - - - - - - - - - - 107.04 116.98 - - - - - - - 11.5 15.0 - - 25.3 - - - - - - - - - - 31.5 41.5 - - - - - - Voltage 69 132 132 150 154 154 154 Approx. Dia.of Conductor Shield [mm] 21.52 22.72 24.62 25.12 17.52 19.52 22.22 Thick.of Insulation 6.86 10.6 10.6 14.22 12.4 12.0 12.0 Approx. Dia.of Insulation Shield [mm] 58.32 48.16 55.02 57.7 63.3 69.28 61.06 74.26 86.0 80.6 87.52 78.64 86.44 100.74 107.54 74.72 85.82 94.82 99.84 106.92 82.96 95.06 106.36 118.52 Approx. Dia.of Insulation Shield [mm] 37.18 45.12 46.82 54.78 43.46 44.46 47.16 Conductor Nominal Area [mm2 ] Shape 305 340 400 240 200 250 325 H.C C.C C.C C.C H.C H.C H.C CorrugatedALSheathType Cu/Kraft(orPPLP)/CAS/PVC[PE] Thick.of Metallic sheath Thick.of Jacket 2.3 2.6 2.7 - 2.5 2.6 2.7 3.5 4.0 4.0 - 4.5 4.5 4.5 OverallDia. Approx. Weight [ton] 105.3 125.9 130.3 - 112.4 124.6 132.0 17.5 22.8 25.1 - 17.4 19.3 22.6 LeadSheathType Cu/Kraft(orPPLP)/LEAD/PVC[PE] Thick.of Metallic sheath Thick.of Jacket - - - 3.55 - - - - - - 4.2 - - - OverallDia. Approx. Weight [ton] - - - 80.62 - - - - - - 16.0 - - - 3 EHV Oil Filled Cable & Accessories SingleCoreCable ThreeCoreCable ※ C.C : Circular Compacted H.C : Hollow Compacted
  3. Accessories Joint & Termination EHV Oil Filled Cable & Accessories RatedVoltage(kV) NominalAreaof Conductor(mm2 2 ) Dimension(mm) L D 130 180 200 240 1300 1530 2000 2400 Lessthan1000 1200~2500 Lessthan2500 Lessthan2500 220-287 330-400 IJ StraightThroughJoint(NJ,IJ) Straight through Joint is used for jointing cables electrically and hydraulically. This joint has same quality as or better than cable itself. Insulated joint is almost same as straight through joint and the difference between them is to put an insulator flange at the center of copper casing. This box is used for jointing cable and at the same time for insulating metal sheath from the other metal sheath to reduce sheath voltage to safety level. CopperCase EpoxyInsulator Anti-CorrosionLayer L ReinforcedInsulationLayer ConductorSleeve ØD 110-161 RatedVoltage(kV) NominalAreaof Conductor(mm2 2 ) Dimension(mm) L D 250 350 350 2900 3400 4100 Lessthan2500 Lessthan2500 Lessthan2500 110-161 220-287 330-400 SJ StopJoint(SJ,SIJ) This joint is used for dividing the oil feeding section in case that route lenght is too long or oil pressure change is too excessive at static or transient operation. This joint is also used for connecting the cables electrically and at the same time, separating the oil feeding section of both cables. Insulated stop joint has an epoxy insulator to dividethemetalsheathsection. CopperCase EarthTerminal OilConnector ConductorSleeve Anti-CorrosionLayer L EpoxyStopUnit InsulationLayer ØD 4 Taihan Electric Wire
  4. RatedVoltage(kV) Dimension(mm) L D 320 320 1750 1955 110-161 220-287 CVSIDE O.FSIDE TransitionJoint(TNJ,TIJ) This joint is used for connecting the oil filled cable and XLPE cable. On the side of XLPE cable, we have applied prefabricated type joint to secure the confidence. The stress cone is made of EPDM and in order to maintain the surface pressure between stress cone and XLPE or epoxy unit, we adopt springs. On the other side, we have used epoxy bell mouth to control the electric field. OutdoorSealingEnd StressReliefCone Anti-CorrosionLayer InsulationPaperLayer L StressReliefCone Connector EpoxyBell-Mouth EarthTerminal ØD Rated Voltage (kV) Dimension(mm) A B C D E 1480 1830 2940 3350 3975 1725 2075 3290 3700 4250 435 435 500 500 600 360 360 480 480 550 315 470 470 470 510 110 161 220 287 400 Sealing end is used for sending and taking electric power into or out of underground cable. This sealing end has stress relief cone formed of wide width paper and above it, there is a condenser cone formed of paper and metal foil or a bellmouth made of epoxy resin to control the electric field. Connector is fastened to the cable condutor by compression method and flexible terminal lug is placed between the conductor and the lead wire to avoid applying unnecessary external force against the sealing end. Connector CoronaShield PorcelainBushing EpoxyBell-Mouth CopperTube EarthTerminal OilConnector Anti-CorrosionLayer ØD ØE A B C 5 EHV Oil Filled Cable & Accessories
  5. This sealing end is used for terminating the underground cable for the SF6 gas switchaear. Epoxy bushings are needed to insulate between the earth potential parts and the high voltage parts. The inner construction of this sealing end is similar to that of an indoor and outdoor sealing end except that this sealing end is completely enclosed and immersed in gas to prevent dust from collecting and to secure the electric capability, etc. Upper Metal Connector Epoxy Bushing Insulation Layer Epoxy Bell-Mouth Fixing Metal Earth Terminal Copper Tube ØA E Rated Voltage (kV) Dimension(mm) A B C D E F G H 990 1350 1170 1550 1260 1700 585 900 375 420 340 390 320 420 380 550 110-161 220-362 The construction of this sealing end is similar to that of an indoor and outdoor sealing end except that the sealing end is completely enclosed and immersed in oil to prevent dust from collecting, and the size of Oil Immersed Sealing End is much smaller than the one of Outdoor Sealing End. This type of sealing end is for connecting underground cable to transformer. Corona Shield Connector Bushing Lower Shield Flange Epoxy Insulator Copper Tube Earth Terminal Oil Connector ØF C D ØH ØG B A ØC ØB 6 Taihan Electric Wire Accessories Joint & Termination EHV Oil Filled Cable & Accessories Rated Voltage (kV) Dimension(mm) A B C D E 112 202 252 220 4801 540 298 559 617 320 582 640 757 960 1400 110-161 220-287 330-400 SF6 GasImmersedSealingEnd OilImmersedSealingEnd
  6. Certificates EHV Oil Filled Cable & Accessories 154kVOilFilledCable1Cx600sqmm(CU) 154kVOilFilledCable1Cx1200sqmm(CU) 154kVOilFilledCable1Cx2000sqmm(CU) 154kVOilFilledCable3Cx250sqmm(CU) 154kVOilFilledCable3Cx200sqmm(CU) 150kVOilFilledCable1Cx1200sqmm(CU) 150kVOilFilledCable1Cx800sqmm(CU) 132kVOilFilledCable1Cx800sqmm(CU) 154kVOilFilledCable3Cx325sqmm(CU) 154kVOilFilledCable1Cx600sqmm(CU) 154kVOilFilledCable1Cx1200sqmm(CU) 154kVOilFilledCable1Cx2000sqmm(CU) 132kVOilFilledCable1Cx960sqmm(CU) 150kVOilFilledCable1Cx600sqmm(CU) 154kVOilFilledCable1Cx2000sqmm(CU) 150kVOilFilledCable1Cx800sqmm(CU) 154kVOilFilledCable1Cx2000sqmm(CU) 345kVOilFilledCable1Cx2000sqmm(CU) 345kVOilFilledCable1Cx1600sqmm(CU) 345kVOilFilledCable1Cx1400sqmm(CU) 275kVOilFilledCable1Cx2000sqmm(CU) 345kVOilFilledCable1Cx1200sqmm(CU) 345kVOilFilledCable1Cx2000sqmm(CU) 150kVOilFilledCable1Cx240sqmm(CU) 345kVOilFilledCable1Cx2000sqmm(CU) 275kVOilFilledCable1Cx2000sqmm(CU) 230kVOilFilledCable1Cx2000sqmm(CU) 400kVPPLPOilFilledCable1Cx2500sqmm(CU) 230kVOilFilledCable1Cx2500sqmm(CU) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 KERI KERI KERI KERI KERI KEMA KEMA KENNEDY&DONKIN KERI KERI KERI KERI CROWNAGENTS NEW-JEC KERI NEW-JEC KERI KERI KERI KERI KEMA KERI KERI PLN KERI KEMA SGS/SPPG TAIHAN SGS/SPPG Aug-78 Jul-97 Oct-83 Dec-84 Dec-84 May-85 May-85 Jul-85 Nov-85 Aug-86 Aug-86 Aug-86 Nov-87 Dec-88 Jan-89 May-89 May-90 Oct-89 May-90 Oct-91 Sep-91 Sep-92 Aug-92 Dec-93 Aug-92 Dec-99 Mar-05 Dec-05 Feb-06 KEPCO KEPCO KEPCO POSCO POSCO IEC141-1 IEC141-1 IEC141-1 POSCO KEPCO KEPCO KEPCO IEC141-1 IEC141-1 KEPCO IEC141-1 KEPCO KEPCO KEPCO KEPCO IEC141-1 KEPCO KEPCO IEC141-1 KEPCO IEC141-1 IEC60141-1 IEC60141-1 IEC60141-1 Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good 750 750 750 750 750 750 750 650 750 750 750 750 650 750 750 750 750 1300 1300 1300 1050 1300 1300 750 1300 1050 1050 1550 1050 No. DescriptionofCable&Accessories Institute Date Specification Resultsof Test BIL(kV) The outstanding quality of TAIHAN EHV Oil Filled cables are verified by internationally accredited certificationinstitutes. TypeTestListofExtraHighVoltageOilFilledCable&Accessories * KERI : Korea Electrotechnology Research Institute * KEPCO : Korea Electricity Power Company( The National Power Utility in Korea) * POSCO : Pohang Steel Corporation 7 EHV Oil Filled Cable & Accessories