1. WINE BAR RECESSED DOWNLIGHT SPACING STUDY
WINE BAR AND BUILT OUT LID-DOWNLIGHTING ONLY IS SHOWN.
FIXTURE SPACING IS PER LIGHTING PLANS DATED 12/12/13
2. WINE BAR RECESSED DOWNLIGHT SPACING STUDY
LIGHT DISTRIBUTION ON BACK WALL OF BAR SERVICE AREA-SHELVING OMITTED FOR CLARITY (PER
PLANS)
BAR WALL OF SERVICE AREA HAS HORIZONTAL LUMENANCE OF 30FC WITH FIXTURE AT 100%
POWER, SPACED PER LIGHTING PLANS
SPACING OF LR AND LR2 FIXTURES INCREASED TO 48", SOME BANDING AND BAR AND
TASK SURFACE RESULTS
3. WINE BAR RECESSED DOWNLIGHT SPACING STUDY
LIGHT SPREAD OF THREE DOWNLIGHTS OVER THE BOOTHS.
EACH BOOTH AND TABLE WILL HAVE PENDANT FIXTURES,
NOT SHOWN IN THIS STUDY.
TOP OF SERVICE COUNTER HAS ABOUT 75FC LUMENANCE WITH RECESSED
LIGHTING AT 100% POWER
WORKPLANE OF BEHIND THE BAR TASK AREA HAS ABOUT 50FC
4. WINE BAR RECESSED DOWNLIGHT SPACING STUDY
LIGHT DISTRIBUTION OF WALLS OF SPECIALTY FOODS WITH SPACING AS SHOWN ON
LIGHTING PLANS DATED 12/12/13. LIGHTS LEVELS OF WORKING PLANE IN TASK
AREAS IS 50 TO 75FC. LIGHT LEVELS UNDER LID IS 50 TO 30FC, FROM RECESSED
LIGHTNG ALONE