Mccb catalogue
1. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Moulded
Case
Circuit
Breaker
Http://www.elcb.net
TOS1 Moulded Case Circuit Breaker ....................................
TOS1L Earth Leakage Circuit Breaker .................................
TOS2 Moulded Case Circuit Breaker ....................................
TOS3 Moulded Case Circuit Breaker ....................................
TOS4 Moulded Case Circuit Breaker ....................................
TOS5 Moulded Case Circuit Breaker ....................................
TOS6 Moulded Case Circuit Breaker ....................................
TOS7 Moulded Case Circuit Breaker ....................................
TOS8 Moulded Case Circuit Breaker ....................................
TOS8-N Moulded Case Circuit Breaker ................................
TOS9 Moulded Case Circuit Breaker ....................................
TOS9-CS.SS Moulded Case Circuit Breaker ......................
TOS9-1 Moulded Case Circuit Breaker ...............................
TOS9-2 Moulded Case Circuit Breaker ...............................
TOS9-10 Moulded Case Circuit Breaker .............................
TOS9-11 Moulded Case Circuit Breaker ...............................
F-01
F/02-03
F/04-05
F/06-07
F/08
F/09-10
F/11-12
F/13-15
F/16
F/17-18
F/19
F/20
F/21
F/22
F/23
F/23
F
2. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS1 series moulded case circuit breaker is one of products developed and manufactured by adopt-
ing international advanced technology. It is supplied with rated insulating voltage 550V and 800V and
used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up
to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-
2 standard.
Specification
TOS1-225M/3P
TOS1-100M/3P
TOS1-63M/4P
TOS1-63M/3P
Type Utili-
zation
cat-
egory
Operation
perform-
ance
Rated
current (A)
Pole Arcing-
over
distance
(mm)
Ultimate
short
circuit
breaking
capacity
(kA)
Servies
short
circuit
breaking
capacity
(kA)
Rated
insul-
ating
volt-
age
(V)
Rated
oper-
ating
volt-
age
(V)
A
1500 8500
1000 7000
1000 4000
(6),10,16,20,
25,32,40,50,63
(10),16,20,25,
32,40,50,63,
80,100
3, 4100,125,160,
180,200,225
225,250,315,
350,400
400
500
630
630,700,800
18
35
22
35
50
22
35
50
35
42
35
42
65
50
65
65
75
80
25
50
35
50
85
35
50
85
50
65
50
65
100
75
100
100
125
150
500V
800V 400V
1000,1250
3
1600
0
0
0( 50)
0( 50)
0( 50)
50
50
50
50
100
100
100
100
100
100
100
100
100
TOS1-63L
TOS1-63M
TOS1-100L
TOS1-100M
TOS1-100H
TOS1-225L
TOS1-225M
TOS1-225H
TOS1-400L
TOS1-400M
TOS1-630L
TOS1-630M
TOS1-630H
TOS1-800M
TOS1-800H
TOS1-1250M
TOS1-1250H
TOS1-1600M
LoadUnload
Note: 6A without thermal protection
The N-pole of four-poles breaker is sited at the right side of the product has four types:
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other
three poles.
Type B: Without current trip-release on N pole which closing and opening with the other poles.
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles.
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the
magnetic release is the instantaneous operation.
Protection Characteristic
TOS1
F-01
3. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application and Description
TOS1L series earth leakage circuit breaker are one of the new type earth leakage breakers which
have been developed by the company using international advanced design and manufacturing
technology. Suitable for a line of AC50/60Hz, rated voltage up to 400V, rated current 16A to 630A.
and is acted as infrequent changeover of circuit or infrequent starting of motor. The breaker has
overload, short-circuit and under-voltage protective function, which can protect the circuit and the
power equipment against damage, meanwhile, it can provide protection to these fire dangers that
caused by these long-time existed grounding fault that can not be detected by the over-current
protection.
This breaker can be installed vertically(upright) or horizontally(transverse).
Wiring of the breaker can not be in adverse direction, that means power supply line must be con-
nected to terminal 1,3 and 5,and the load line connected to terminal 2,4 and 6.
The rated residual operating current I n and the maximum breaking time can be adjusted on site
according to practical condition.
The leakage protection module still can work normally when the phase voltage reduce to 50V.It has
the same overall size with the TOS1 series breakers, which make the installation more exchangeable.
The breakers are suitable for isolation, its symbol are:
The breakers comply with the demands of the following standards:
IEC60947-1 and GB/T 14048.1 General
IEC60947-2 and GB 14048.2 Low voltage breakers
IEC60947-4 and GB 14048.4 Contactors and motor starters
IEC60947-5.1 and GB 14048.5 Electrical equipments of electromechanical control circuit
TOS1L-100M/4P
TOS1L-225M/3P
Main Technical Specifications
Table 1
Type
Service short-
circuit breaking
capacity lcs(kA)
Operation
performance
(time)
Rated residual non-
operatingcurrent I no(mA)
TOS1L-100
100
TOS1L-225
225
TOS1L-400
400
TOS1L-630
630
(10)16I20I25I32I
40I50I63I80I100
100, 125, 160,
180, 200, 225
225, 250, 315,
350,400
400, 500, 630
3 4
AC800
AC 400V
8000
50
M H
Frame current Inm(A)
Rated current In(A)
Pole number
Rated iInsulation voltage Ui(V)
Rated working voltage Ue(V)
Rated impulse with
stand voltage Uimp(V)
Arc-over distance(mm)
Breaking capacity grade
3 4 3 4 3 4
M H M M
50
35
Limiting short-
circuit breaking
capacity lcu (kA)
AC400V
AC400V
85
50
50
35
50
35
85
50
50
35
65
42
65
42
Rated residual
operating current
I n(mA)
Non-delay
type
Delay type
100/300/500
100/300/500 300/500/1000
1/2 I n
Electrified
Unelectrified
1500
8500
1000
7000
1000
4000
1000
4000
TOS1L
Earth Leakage Circuit Breaker
MouldedCase
CircuitBreaker
F-02
4. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Type A: N-pole without over-current release unit, it has been connected all the time, not closing and opening
with the other three poles.
Type B: N-pole without over-current release unit, which closing and opening with the other three poles.
Type C: N-pole fixed with over-current release unit, which closing and opening with the other three poles.
Type D: N-pole fixed with over-current release unit, it has been connected all the time, not closing and
opening with the other three poles.
1. The limiting breaking and arc-over distance includes horizontal and vertical installation.
2. If the three-pole breaker of this series is connected with three phase load, the load can not have neutral
line, otherwise the breaker will have fault action.
3. If the three-pole breaker of this series is connected with single phase load, the phase line will be connected
to the left pole, and the neutral line is connected to the right pole, the middle pole is blanket
The thermal release of the breaker has again-time-limit property; the electromagnetic release is inst.
Operation, its property see table 2(for distribution),table 3 (motor protection).
Protection Characteristic
Table 2
Rated current
of release(A)
Thermal release (ambient temperature +40 )
1.05In(cold state )
non-trip time (h)
1.03In(hot state)
trip time (h)
Electromagnetic release
tripping current(A)
10 In 63
63 In 125
1
2
1
2
125 In 630 2 2
10In 20%
5In 20%
10In 20%
Table 3
Rated current
of release
Thermal release (ambient temperature +40 )
1.0In
(cold state)
non-trip time
(h)
1.20In(hot
state) trip
time(h)
1.50In
(thermal state)
trip time
7.2In(cold
state) trip
time
Electromagnetic
release tripping
current(A)
10 In 400 2 2 8min 6s<Tp 20s 12In±20%
Non-delay type operation characteristics see table 4(I n 30mA should be Non-delay type)
Residual Current Operating Time of Earth Leakage Circuit Breaker
Note: a
to I n 30mA earth leakage circuit breaker, 0.25A can instead of 5I n According
toa
,adopt 0.25A, then 10 I n is 0.5A.
Table 4
Rated current
Non-delay type Max.breaking time(s)
I n
0.3
2I n
0.15
5I na
0.04
10I n
0.04
TOS1L
F-03
Note: According to the pole number of product, it calssifies three and four poles. The neutral pole
(N-Pole) of the four-poles products has four types:
Earth Leakage Circuit Breaker
5. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application
TOS2 series moulded case circuit breaker is one of breaker which adopts international advanced
design, manufacture technology to develop. The rated insulating voltage is 750V, suitable for AC 50/
60Hz,rated working voltage 690V or below, rated working current is 12.5A to 1600A of circuit and
used in distributing electric energy, and non-frequent breaking in the normal conditions , protecting
the circuit equipment from overload under voltage, circuit breaker with rated frame current 400A
or below,can be used in mousecage motor’s non-frequent start, breaking during working, protecting
motor from overload, short circuit undervoltage,the product conforms to IEC60947-2 standard.
Note:1. The N-pole breaker has no protection which closing and opening with the other three poles.
2. The type of thermal magnetic for TOS2-400/630 has no four poles.
Specifications Table 1
Rated ultimate
short circuit
breaking capacity
Icu (kA) at 380/415V
Rated service
short circuit
breaking
capacity Ics at
380/415V(kA)
25
70
150
36
70
150
36
70
150
45
70
150
45
70
150
37.5
37.5
25
70
150
36
70
150
36
70
150
45
70
150
45
70
150
50
50
Operation
perfor-
mance
ON OFF
1500
1000
1000
1000
1000
1000
8500
7000
7000
4000
4000
4000
Type Pole Rated
insulat-
ing
voltage
(V)
Rated
operating
voltage
(V)
TOS2-100N
TOS2-100H
TOS2-100L
TOS2-160N
TOS2-160H
TOS2-160L
TOS2-250N
TOS2-250H
TOS2-250L
TOS2-400N
TOS2-400H
TOS2-400L
TOS2-630N
TOS2-630H
TOS2-630L
TOS2-1250N
TOS2-1600N
3, 4
pole
750
690
or
below
Utiliza-
tion
category
A
3 pole
Trip Units Main Technical Parameter
Thermal magnetic release
Rated current In(A) NoteType
TOS2-100
TOS2-160
TOS2-250
TOS2-400
TOS2-630
TOS2-1250
TOS2-1600
12.5,16,20,25,32,40,50,63,80,100
16,20,25,32,40,50,63,80,100,125,160
160 180 200 225 250
315 350 400
400 500 630
800 1000 1250
1000 1250 1600
T adjustable (0.8~1In)
M adjustable (5~10In)
T adjustable (0.8~1In)
M fixed
TOS2
MouldedCase
CircuitBreaker
F-04
TOS2-630N/3P
TOS2-400N/3P
TOS2-250N/3P
TOS2-100N/3P
6. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
TOS2 22SE: protection of low-voltage distribution networks for TOS2-100160250
Electronic release
TOS2-630N/4P
TOS2-250N/4P
TOS2-1600N
1. Overload protection with adjustable threshold
2. Short-circuit protection with adjustable threshold
3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold.
Ir=0.4 1 In(adjustable 48 setting)
Tripping between 1.05 1.3 Ir (IEC60947-2)
(Long-time overload protection)
Im=2-3-4-5-6-7-8-10 Ir
(Short-circuit protection)
Rated current In(A) NoteType
TOS2-100
TOS2-160
TOS2-250
40 100
40 100 160
40 100 160 250
1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10
2. Short-circuit protection with fixed threshold (13xIr)
3. phase failure protection (tripping time delay between 3.5s-6s)
4. Load indication : dark less than 105% of Ir setting threshold; Flashing at 105% or more of Ir setting
threshold.
TOS2 22ME: protection of motor forTOS2-100160250
Rated current In(A) NoteType
TOS2-100
TOS2-160
TOS2-250
40 50 80 100
40 50 80 100 150
40 50 80 100 150 220
Ir=0.6-0.63-0.67-0.71-0.75-0.80-0.85
-0.90-0.95-1 In
1. Overload protection with adjustable threshold
2. Short-circuit protection with adjustable threshold
3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold
TOS2 23SE: protection of low-voltage distribution networks for TOS2-400630
TOS2
F-05
7. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application
TOS3 series moulded case circuit breaker is one of new products developed and manufactured by
adopting international advanced technology. It is supplied with rated insulating voltage 690V and
used for circuit of AC 50/60Hz, rated operating voltage AC 415V or below, rated opereating current
from 16A to 630A. It is designed for protection of electric circuit, motors, transformers and other
equipments. The products conforms to IEC60947-2 standard.
Specifications
TOS3-400
TOS3-250
TOS3-160
Type
Poles number
Rated current In(A)
Rated operating voltage Ue(V) AC 50/60Hz
Rated insulation voltage Ui(V)
Rated impulse withstand voltage Uimp(kV)
Utilisation category
AC 220/240V
AC 380/415V
AC 690V
AC 220/240V
AC 380/415V
AC 690V
Rated ultimate short-circuit
breaking capacity Icu(kA)
Rated short-circuit service
breaking capacity
Ics(kA)
TOS3-160X
3
20~160A
690
800
8
A
65
40
8
65
40
4
TOS3-160
3
50~160A
690
800
8
A
65
40
12
65
40
6
TOS3-250
3
100~250A
690
800
8
A
65
40
12
65
40
6
TOS3-400
3
200~400A
690
800
8
A
65
40
12
65
40
6
TOS3-630
3
315~400A
690
800
8
A
65
40
12
65
40
6
Thermomagnetic
T(thermal)
M(magnetic)
TOS3-630TOS3-400
315A
400A
500A
630A
200A
250A
315A
400A
TOS3-250TOS3-160TOS3-160X
200A
250A
20A
32A
40A
50A
63A
80A
100A
125A
160A
16~20A
25~32A
32~40A
40~50A
50~63A
63~80A
80~100A
100~125A
125~160A
T adjustable
(0.8~1.0In)
300A
300A
600A
600A
600A
1000A
1000A
1000A
1500A
M
50A
63A
80A
100A
125A
160A
40~50A
50~63A
63~80A
80~100A
100~125A
125~160A
T adjustable
(0.8~1.0In)
300~600A
300~600A
400~800A
500~1000A
625~1250A
800~1600A
M
adjustable
160~200A
200~250A
T adjustable
(0.8~1.0In)
1000~2000A
1200~2500A
M
adjustable
160~200A
200~250A
250~315A
315~400A
T adjustable
(0.8~1.0In)
1000~2000A
1200~2500A
1575~3150A
2000~4000A
M
adjustable
250~315A
315~400A
400~500A
500~630A
T adjustable
(0.8~1.0In)
1575~3150A
2000~4000A
2500~5000A
3250~6500A
M
adjustable
In In
In In
TOS3
MouldedCase
CircuitBreaker
F-06
8. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Outline and Installation Dimension
TOS3-400
TOS3-630
TOS3-160
TOS3-250
TOS3
F-07
9. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application
TOS4 series moulded case circuit breaker is applicable circuit of AC 50/60Hz, rated insulation voltage
690V, rated current 16-250A, for distribute energy of electricity & infrequent making & breaking circuit
in normal conditions, protecting when circuit is overloaded, short circuit. The products conforms to
IEC60947-2 standard.
TOS4-125
TOS4-250
Specifications
Type
Poles number
Rated current In(A)
Utilisation category
Rated ultimate short-circuit breaking capacity
Icu(kA) at 415V
Rated short-circuit service breaking capacity
Ics(%Icu) at 415V
TOS4-125
3
16, 20, 32, 40, 50, 63,
80, 100, 125
A
16
100
TOS4-250
3
100, 160, 180,
200, 250
A
25
100
Outline and Installation Dimension
TOS4
MouldedCase
CircuitBreaker
F-08
10. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS5 series moulded case circuit breaker , it’s applicable circuit of AC 50/60Hz,rated insulation volt-
age 690V(MTM6-125 500V),rated operating voltage AC 690V or below ,rated operating current 12.5-
1600A, for distribute energy of electric and infrequent making and breaking circuit in normal condition.
The circuit-breakers are provided with the function of the protection against overload and short circuit
and under-voltage. The circuit breakers comply with standard of IEC60947-2.The circuit-breakers are
double insulating (Inm=250A or above), the control circuit of the accessories is set apart with the
main circuit , and doesn’t need to open the cover of the circuit breaker when install the accessories.
Specification
TOS5-125L/1P
TOS5-125L/2P
TOS5-160L/3P
TOS5-125L/3P
Table 1
Pole
number
3, 4
1,2,
3,4
3
Type
TOS5-125L
TOS5-160L
TOS5-160M
TOS5-250L
TOS5-250M
TOS5-250H
TOS5-400L
TOS5-400M
TOS5-400H
TOS5-630L
TOS5-630M
TOS5-630H
TOS5-800L
TOS5-800M
TOS5-800H
TOS5-1250L
TOS5-1600L
Utiliza-
tion
category
A
Rated short-
circuit serrice
breaking
capocity Ics
(%icu)
50%
75%
75%
100%
75%
75%
100%
100%
75%
100%
100%
100%
100%
100%
100%
100%
Ultimate short circuit
breaking capacity Icu
(kA)
Rated
insulat-
ing
voltage
(V)
800
500
690
500
Rated
operating
voltage
(V)
690
and
below
AC380V
(400)
25
35
50
35
65
85
35
65
100
35
50
65
35
50
65
50
AC660V
(690)
-
8
10
14
18
20
18
22
30
20
22
25
20
22
25
20
Trip Units Main Technical Parameter (See Table 2)
TOS5
F-09
11. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
TOS5-400L
TOS5-400L/3P
TOS5-1600L
TOS5-250L/3P
TOS5-125L/3P
Thermal magnetic releaseType
TOS5-125
TOS5-160
TOS5-250
TOS5-400
TOS5-630
TOS5-800
TOS5-1250
TOS5-1600
12.5,16,20,25,32,40,
50,63,80,100,125
16,20,25,32,40,50,
63,80,100,125,160
100,125,160,180,
225,250
225,250,315,
350,400
400,500,630
630,700,800
-
-
I1=0.4 1 In TOS5 PR211(L-LI)
I1=0.4 1 In TOS5 PR212(LSI-LSIG)
Tripping between 1.05 1.3 I1
(IEC60947-2) I2
t=constant
(Long-time overload protection)
I2=1-2-3-4-6-8-10 In
t2=0.05s, 0.1s, 0.25s, 0.5s adjustable
(Short-circuit short time delay protection)
I3=1.5-2-4-6-8-10-12 In
(Instantaneous short-circuit protection)
I4=0.2-0.3-0.4-0.6-0.8-0.9-1 In
t4= 0.1s, 0.2s, 0.4s, 0.8s adjustable
(Earth fault protection)
Rated current
In(A)
Electronic release
Note
Rated
current In(A)
-
-
-
320,400
630
800
800,1000,
1250
1000,
1250,1600
Table 2
Note: T-thermal M-magnetic L-long time S-short time relay I-instantaneous G-earth fault TOS5-125/160
In=12.5,16,20,32,40 magnetic protection that is fixed at 500A.
T fixed or
adjustable (0.7~1In)
M fixed
Note
T fixed
M fixed
T adjustable (0.7~1In)
M fixed
T adjustable (0.7~1In)
M fixed
T fixed
M fixed
T fixed
M fixed
-
-
Accessories
1) Wiring diagram of type CDM electromagnetic operation device(fitting TOS5-125,160,250) see the
following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)
1. The external accessories of the breaker
Motor-driven operation device
Code description: SB1
SB2
stand for push button.(provided by users themselves) Number “1” “2”
================“3” stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V, DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting TOS5-400 630 800)
TOS5
MouldedCase
CircuitBreaker
F-10
12. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS6 moulded case circuit breaker is suitable for circuit AC 50/60Hz, rated voltage up to AC 690V,
rated operating current up to 630A.It features normal structure, reliable performance, high breaking
capacity, used for power distribution and protecting the circuit and electrical equipment against over-
load and short circuit. It complies with standard of IEC60947-2.
Specification
Type
Poles number
Rated current In(A)
Rated operating voltage Ue(V) (AC50/60Hz)
Rated insulation voltage Ui(V)
Rated impulse withstand voltage Uimp(kV)
Utilisation category
Frequency withstand voltage 1 Minute
Rated limited
short-circuit
breaking capacity
Icu(kA)
220/230V
380/415V
400V
500V
690V
220/230V
380/415V
400V
500V
690V
220/230V
380/415V
400V
500V
690V
Operating recycle times
Operating recycle times
per hour
Operating recycle times
Operating recycle times
per hour
TOS6-250
3
100~250
690
800
8
A
3000
50
36
25
20
5
75%
75%
75%
75%
75%
105
75.6
52.5
40
7.7
25000
240
8000
120
TOS6-400
3
250~400
690
1000
8
A
3500
70
36
30
25
20
100%
100%
100%
100%
100%
154
75.6
63
52.5
40
20000
240
6000
120
TOS6-630
3
400~630
690
1000
8
A
3500
70
36
30
25
20
100%
100%
100%
100%
100%
154
75.6
63
52.5
40
20000
120
5000
60
Rated operating
short-circuit
breaking capacity
Ics(100%Icu)
Rated short-circuit
closing capacity
Icn(kA)
Mechanical life
Eectrical life
TOS6-160
3
16~160
690
800
8
A
3000
25
16
10
8
3
100%
100%
100%
100%
100%
52.5
32
17
13.6
4.3
25000
240
8000
120
TOS6
F-11
TOS6-160
TOS6-250
13. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Outline and Installation Dimension
TOS6-160
TOS6-630
TOS6-400
TOS6-250
TOS6
MouldedCase
CircuitBreaker
F-12
Moulded Case Circuit Breaker
17. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application
TOS8 series moulded case circuit breaker is suitable for industrial or commercial power and lighting
with AC50/60Hz, rated working voltage up to AC600V/DC250V, rated current up to 630A. It’s a kind of
economical breaker with the characters of stable and reliable function, beautiful appearance, small
size and long life. It can be used for conversion of line and infrequent starting motor. It can also be
attached to install the accessories which have protection function for avoiding loss-voltage,
undervoltage. The product can install connection line with front board and back board, it also can
equip hand-operating apparatus or motor-operating apparatus to control in a remote distance.
TOS8-403
TOS8-203
TOS8-53
TOS8-52
Specification
The rated insulation voltage for this series of circuit breaker is 690V, the rated operating voltage is
600V, the rated frequency is 50Hz, the other rated values for the main circuit.
Frame size(AF)
Rated current(A)
Rated operational voltage(V)Ue (50/60Hz)
Rated insulation voltage(V)Ui(50/60Hz)
Rated impulse withstand voltage(kV)Uimp
Utilisation category
Endurance
Endurance
220V/240V
380V
415V
440/460V
480/500V
600V
Mechanical
Electrical
Frame size(AF)
Rated current(A)
Rated operational voltage(V)Ue (50/60Hz)
Rated insulation voltage(V)Ui(50/60Hz)
Rated impulse withstand voltage(kV)Uimp
Utilisation category
Type 2pole
3pole
Utimate breaking capacity
(kA,Icu AC 50/60Hz)
5,10,15,20,30,40,50
TOS8-32E
TOS8-33S
30
5,10,15,20,30
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-52E
TOS8-53E
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-52S
TOS8-53S
600
690
6
25
14/10
14/10
10
7.5
5
A
8500
1500
TOS8-62E
TOS8-63E
600
900
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-62S
TOS8-63S
600
900
6
25
14/10
14/10
10
7.5
5
A
8500
1500
50
60
60
Type
2pole
3pole
Uitimate breaking
capacity (kA,Icu
AC 50/60Hz)
Mechanical
Electrical
TOS8-102E
TOS8-103E
5,10,15,20,
30,40,50,
60,75,100
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
100
TOS8-102S
TOS8-103S
15,20,30,
40,50,60,
75,100
600
690
6
50
25
25
25
25
14
A
8500
1500
225
100,125,150,175,
200,225
250,300,350,400
TOS8-203E
600
690
6
35
18
18
18
10
7.5
A
7000
1000
TOS8-203S
600
690
6
50
25
25
25
14
10
A
7000
1000
TOS8-403E
600
690
6
35
30
25
25
18
18
A
4000
1000
TOS8-403S
600
690
6
50
42
35
35
25
22
A
400
1000
220V/240V
380V
415V
440/460V
480/500V
600V
400
TOS8
MouldedCase
CircuitBreaker
F-16
18. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS8-N series moulded case circuit breaker is suitable for industrial or commercial power and light-
ing with AC50/60Hz, rated working voltage up to AC600V/DC250V, rated current up to 630A. It’s a
kind of economical breaker with the characters of stable and reliable function, beautiful appearance,
small size and long life. It can be used for conversion of line and infrequent starting motor. It can also
be attached to install the accessories which have protection function for avoiding loss-voltage,
undervoltage. The product can install connection line with front board and back board, it also can
equip hand-operating apparatus or motor-operating apparatus to control in a remote distance.
Specification
The rated insulation voltage for this series of circuit breaker is 690V, the rated operating voltage is
600V, the rated frequency is 50Hz, the other rated values for the main circuit.
TOS8-N103
TOS8-N203
Endurance
220V/240V
380V
415V
440/460V
480/500V
600V
Mechanical
Electrical
5,10,15,20,30,40,50 60
Frame size(AF)
Rated current(A)
Rated operational voltage(V)Ue (50/60Hz)
Rated insulation voltage(V)Ui(50/60Hz)
Rated impulse withstand voltage(kV)Uimp
Utilisation category
Type
2pole
3pole
TOS8-N32E
TOS8-N33S
30
5,10,15,20,30
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-52E
TOS8-53E
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-N52S
TOS8-N53S
600
690
6
25
14/10
14/10
10
7.5
5
A
8500
1500
TOS8-N62E
TOS8-N63E
600
900
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
TOS8-N62S
TOS8-N63S
600
900
6
25
14/10
14/10
10
7.5
5
A
8500
1500
50 60
Utimate breaking
capacity
(kA,Icu AC 50/60Hz)
Type 2pole
3pole
Frame size(AF)
Rated current(A)
Rated operational voltage(V)Ue (50/60Hz)
Rated insulation voltage(V)Ui(50/60Hz)
Rated impulse withstand voltage(kV)Uimp
Utilisation category
Uitimate breaking
capacity
(kA,Icu AC
50/60Hz)
Endurance
220V/240V
380V
415V
440/460V
480/500V
600V
Mechanical
Electrical
400
250,300,350,400
TOS8-N403E
600
690
6
35
30
25
25
18
18
A
4000
1000
TOS8-N403S
600
690
6
50
42
35
35
25
22
A
400
1000
TOS8-N102E
TOS8-N103E
5,10,15,20,
30,40,50,
60,75,100
600
690
6
10
7.5/5
7.5/5
5
2.5
2.5
A
8500
1500
100
TOS8-N102S
TOS8-N103S
15,20,30,
40,50,60,75,
100
600
690
6
50
25
25
25
25
14
A
8500
1500
TOS8-N203E
600
690
6
35
18
18
18
10
7.5
A
7000
1000
225
TOS8-N203S
600
690
6
50
25
25
25
14
10
A
7000
1000
100,125,150,
175,200,225
TOS8-N
F-17
19. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Outline and Installation Dimension
TOS8-N225
TOS8-N400
TOS8-N30,50,60
TOS8-N100
TOS8-N
MouldedCase
CircuitBreaker
F-18
Moulded Case Circuit Breaker
20. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
TOS9-400
TOS9-125
TOS9-100
TOS9-63
Application
TOS9 series moulded case circuit breaker is applicable circuit of AC 50/60Hz, rated insulation voltage
690V, rated operating current 15-225A, for distribute energy of electricity and infrequent making &
breaking circuit in normal conditions. The products conforms to IEC60947-2 standard.
Outline and Installation Dimension
Specification
Type
Poles number
Rated current In(A)
Rated operating voltage Ue(V)
Rated insulation voltage Ui~(V)
Utilisation category
AC 500V
AC 440V
AC 415V
AC 380V
AC 240V
AC 500V
AC 440V
AC 415V
AC 380V
AC 240V
Rated ultimate short-circuit
breaking capacity Icu(kA)
Rated short-circuit service
breaking capacity
Ics(kA)
TOS9-100
3
15~100
AC 600V DC 250V
AC 690V
A
2
5
5
5
7.5
1
2.5
2.5
2.5
3.8
TOS9-225
3
100~225
AC 660V
AC 690V
A
5
7.5
7.5
7.5
15
2.5
3.8
3.8
3.8
7.5
TOS9-100
TOS9--225
TOS9
F-19
21. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
TOS9-100CS.SS
TOS9-400CS.SS
TOS9-250CS.SS
TOS9-50CS.SS
Application
TOS9-CS.SS series moulded case circuit breaker is features of reliable working out and steady performance,
reasonable structure, beautiful appearance and small volume etc. It can be used in the circuit of 50Hz or
60Hz, rated voltage up to 600V. It is used to distribute electric energy in distribution network and be overload
or short circuit protection power equipment, and also can be used in transformation of circuit unfrequency
under the normal conditions.
Outline and Installation Dimension
Specification
TOS9-30CS.SS
TOS9-60CS.SS
Rated breaking capacity(KA)
240V 380V
5/2
5/2
5/2
10/5
18/9
36/18
36/18
5/2.5
10/7.5
10/7.5
30/20
30/22
50/35
50/35
50/35
415V
2.5/1
2.5/1
2.5/1
10/5
15/8
25/13
25/13
2.5/1.5
7.5/5
7.5/5
7.5/5
25/15
25/20
50/30
50/30
600V
-
-
-
-
-
-
-
-
-
-
5/2.5
5/2.5
15/10
15/10
15/10
500V
2.5/1
2.5/1
2.5/1
7/4
10/5
15/8
15/8
2.5/1.0
7.5/5
7.5/5
15/10
18/15
35/25
35/25
35/25
600V
-
-
-
-
-
-
-
-
2.5/1.5
2.5/1.5
10/5
15/10
25/18
25/18
25/18
Utiliza-
tion
category
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Rated
current(A)
Poles
num-
ber
2,3
2,3
3
2,3
3
3
3
3
3
3
3,4
3,4
3,4
3,4
3
Type
TOS9-30CS
TOS9-50CS
TOS9-60CS
TOS9-100CS
TOS9-250CS
TOS9-400CS
TOS9-630CS
TOS9-30SS
TOS9-50SS
TOS9-60SS
TOS9-100SS
TOS9-250SS
TOS9-400SS
TOS9-630SS
TOS9-800SS
5/2
5/2
5/2
25/13
30/15
50/25
50/35
5/5
5/10
50/10
50/42
50/42
85/60
85/60
85/60
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
600,700,800
TOS9-CS.SS
MouldedCase
CircuitBreaker
F-20
22. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS9-1 series moulded case circuit breaker is features of reliable working out and steady performance,
reasonable structure, beautiful appearance and small volume etc. It can be used in the circuit of 50Hz or
60Hz, rated voltage up to 600V. It is used to distribute electric energy in distribution network and be overload
or short circuit protection power equipment, and also can be used in transformation of circuit unfrequency
under the normal conditions.
TOS9-1-50A
TOS9-1-250A
TOS9-1-400A
TOS9-1-630A
Specification
Outline and Installation Dimension
Rated breaking capacity(KA)
240V 380V 415V 600V500V 600V
Utiliza-
tion
category
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Rated
current
(A)
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
600,700,800
Poles
num-
ber
2,3
2,3
3
2,3
3
3
3
3
3
3
3,4
3,4
3,4
3,4
3
Type
TOS9-1-30CS
TOS9-1-50CS
TOS9-1-60CS
TOS9-1-100CS
TOS9-1-250CS
TOS9-1-400CS
TOS9-1-630CS
TOS9-1-30SS
TOS9-1-50SS
TOS9-1-60SS
TOS9-1-100SS
TOS9-1-250SS
TOS9-1-400SS
TOS9-1-630SS
TOS9-1-800SS
5/2
5/2
5/2
25/13
30/15
50/25
50/35
5/5
5/10
50/10
50/42
50/42
85/60
85/60
85/60
5/2
5/2
5/2
10/5
18/9
36/18
36/18
5/2.5
10/7.5
10/7.5
30/20
30/22
50/35
50/35
50/35
2.5/1
2.5/1
2.5/1
10/5
15/8
25/13
25/13
2.5/1.5
7.5/5
7.5/5
7.5/5
25/15
25/20
50/30
50/30
2.5/1
2.5/1
2.5/1
7/4
10/5
15/8
15/8
2.5/1.0
7.5/5
7.5/5
15/10
18/15
35/25
35/25
35/25
-
-
-
-
-
-
-
-
2.5/1.5
2.5/1.5
10/5
15/10
25/18
25/18
25/18
-
-
-
-
-
-
-
-
-
-
5/2.5
5/2.5
15/10
15/10
15/10
TOS9-1-30
TOS9-1-60
TOS9-1
F-21
23. Standrad: IEC 61947-2
Moulded Case Circuit Breaker
Application
TOS9-2 series moulded case circuit breaker is features of reliable working out and steady performance,
reasonable structure, beautiful appearance and small volume etc. It can be used in the circuit of 50Hz or
60Hz, rated voltage up to 600V. It is used to distribute electric energy in distribution network and be overload
or short circuit protection power equipment, and also can be used in transformation of circuit unfrequency
under the normal conditions.
Specification
Rated breaking capacity(KA)
240V
5/2
5/2
5/2
25/13
30/15
50/25
50/35
5/5
5/10
50/10
50/42
50/42
85/60
85/60
380V
5/2
5/2
5/2
10/5
18/9
36/18
36/18
5/2.5
10/7.5
10/7.5
30/20
30/22
50/35
50/35
415V
2.5/1
2.5/1
2.5/1
10/5
15/8
25/13
25/13
2.5/1.5
7.5/5
7.5/5
7.5/5
25/15
25/20
50/30
600V
-
-
-
-
-
-
-
-
-
-
5/2.5
5/2.5
15/10
15/10
500V
2.5/1
2.5/1
2.5/1
7/4
10/5
15/8
15/8
2.5/1.0
7.5/5
7.5/5
15/10
18/15
35/25
35/25
600V
-
-
-
-
-
-
-
-
2.5/1.5
2.5/1.5
10/5
15/10
25/18
25/18
Utiliza-
tion
category
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Rated
current
(A)
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
3,5,10,15,20,30
10,15,20,30,40,50
60
60,70,100
125,150,175,200,225,250
250,300,350,400
500,600,630
Poles
num-
ber
2,3
2,3
3
2,3
3
3
3
3
3
3
3,4
3,4
3,4
3,4
Type
TOS9-2-30CS
TOS9-2-50CS
TOS9-2-60CS
TOS9-2-100CS
TOS9-2-250CS
TOS9-2-400CS
TOS9-2-630CS
TOS9-2-30SS
TOS9-2-50SS
TOS9-2-60SS
TOS9-2-100SS
TOS9-2-250SS
TOS9-2-400SS
TOS9-2-630SS
TOS9-2-250A
TOS9-2-125A
TOS9-2-32A
Outline and Installation Dimension
TOS9-2-30
TOS9-2-60
TOS9-2
MouldedCase
CircuitBreaker
F-22
24. Standrad: IEC 60947-2
Moulded Case Circuit Breaker
Application
TOS10 Series Moulded Case Circuit Breaker is available in two frame sizes from 25 to 800 amps,
loadline series of moulded case circuit breakers provide overload and short-circuit protection for the
full range of transformer sizes encountered in normal service. The overload and instantaneous trip-
ping elements, adjustable over all wide band, make these MCCBs ideal for many distribution application.
TOS10-250A
TOS10-100A
Specification
Tripping Elements
Overload front adjustable 0.7-1.0 times rated current
Instantaneous: non-adjustable AA 25~63=400A AA 80~250=10In
Type
Poles number
Rated current In(A)
Rated insulation voltage Ui(V)
Utilisation category
Rated ultimate short-circuit breaking
capacity Icu(kA) at 415V
Rated short-circuit service breaking
capacity Ics(%Icu) at 415V
TOS10-160
3
125,160
AC660
A
65
75%
TOS10-250
3
160,200,250
AC660
A
65
75%
TOS10-100
1,3
25,32,40,50,60,80,100
AC500
A
25
75%
Switch Disconnector
Current rating In(A): 250 3pold
Outline and Installation Dimension
TOS10-250/3P
TOS10
F-23
TOS11 Moulded Case Circuit Breaker
Application
TOS11 series Moulded Case Circuit Breaker is applicable circuit of AC 50/60Hz, rated insulation
voltage 690V, rated current 16-250A, for distribute energy of electricity & infrequent making & break-
ing circuit in normal conditions, protecting when circuit is overloaded, short circuit. The products con-
forms to IEC60947-2 standard.
Specification
Type
Poles number
Rated current In(A)
Rated ultimate short-circuit breaking capacity
Icu(kA) at 415V
Rated short-circuit service breaking capacity
Ics(%Icu) at 415V
TOS11-31
3
16, 20, 32,
40, 50, 63, 80,
100
TOS11-35
3
16, 20, 32, 40, 50,
63, 80,100, 160,
200, 250
TOS11-39
3
250,320,400,
500,630
Utilisation category A
60
100
A
15
100
A
40
100
TOS11-31
TOS11-35