SlideShare ist ein Scribd-Unternehmen logo
1 von 1
Downloaden Sie, um offline zu lesen
Dead Hung (25'-8")
Dead Hung (25'-10")
Trough #4
Trough #3
Trough #2
Trough #1
LX 1
LX 2
LX 3
FOH 1
FOH 2
1'0" 2'0" 3'0" 4'0" 5'0" 6'0" 7'0" 8'0" 9'0" 10'0" 11'0" 12'0" 13'0" 14'0" 15'0" 16'0" 17'0" 18'0" 19'0" 20'0" 21'0" 22'0" 23'0" 24'0" 25'0"1'0"2'0"3'0"4'0"5'0"6'0"7'0"8'0"9'0"10'0"11'0"12'0"13'0"14'0"15'0"16'0"17'0"18'0"19'0"20'0"21'0"22'0"23'0"24'0"25'0"
1'0" 2'0" 3'0" 4'0" 5'0" 6'0" 7'0" 8'0" 9'0" 10'0" 11'0" 12'0" 13'0" 14'0" 15'0" 16'0" 17'0" 18'0" 19'0" 20'0" 21'0" 22'0" 23'0" 24'0" 25'0"1'0"2'0"3'0"4'0"5'0"6'0"7'0"8'0"9'0"10'0"11'0"12'0"13'0"14'0"15'0"16'0"17'0"18'0"19'0"20'0"21'0"22'0"23'0"24'0"25'0"
CL
CL
Boom DSLBoom DSR
Floor Mount USL
LX 4
LPLP
Floor Mount USR
FOH 2Balcony Rail
No 1
Torm HR
No 1
Torm HL
No 2
Torm HL
Not shown in position
Not shown in position
Not shown in position
Not shown in position
No 2
Torm HR
Ground Row
Floor Mount DS
15
23
13
109
11
22
10
4
8
21
7
105
5
3
4
20
19
24
20
5
25
6
22
25
23
110
26
26
8
114
11
29
10
33
12
113
14
34
15
30
17
66
19
31
20
67
6
28
5
32
3
72
4
27
12
36
10
60
9
35
8
70
7
59
4
77
2
80
14
68
15
37
16
71
17
68
18
61
19
74
64MFL
4
88
64MFL
2
91
64MFL
1
90
64MFL
16
85
6
105
1
72
14
106
4
40
3
50
2
46
1
45
6
41
8
52
9
112
5
39
13
42
27
107
64MFL
3
89
64MFL
14
86
1 95
2 96
3 97
4 97
1100
2101
3102
4102
2'-0"
3'-0"
1'-0"
1'-0"
3'-0"
2'-0"
1'-0"
1'-0"
17
133
9
136
16
117
9
116
23
131
3
285
1
142
1
143
3
136
21
133
2
262
1
260
29
260
28
262
7
54
2
53
13
54
18
55
16
55
22
286
1
38
6
120
5
120
4
120
3
120
2
120
1
120
7
120
8
120
9
120
10
120
11
120
21
272
20
277
11
278
13
273
6
272
5
277
5
275
7
270
C6 C5 C4 C3 C2 C1 B6 B5 B4 B3 B2 B1 A6 A5 A4 A3
127
A2
128
A1
129
D6 D5 D4 D3 D2 D1E6 E5 E4 E3 E2 E1
6
138
12
139
8
271
7
276
10
276
11
27164MFL
15
266
24
268
Not shown in position
12
10
18
11
58
464
165
383
284
612
1133
2134
3283
4284
6 7
5 9
4 62
3 63
2 81
1 82
4 137
3 137
2 281
1 282
A3
123
A2
124
A1
125
B3 B2 B1C3 C2 C1D3 D2 D1E3 E2 E1
General Notes
1. Units are Space 18" apart Typical unless
otherwise noted.
2. Electrics are marked every 18" from center
3. FOH Positions may not be drawn in position.
4. Cyc Units, Ground Units, and MR 16 strips
spacing will be determined during focus.
5. Floor Mounts and Booms will be marked during
focus.
6. Boom units are attached to side arms and
measured from center of units.
7. Boom placement will be determined during
focus.
8. Trim heights will be determined during focus.
9. Due to spacing, Use paperwork to get units
purpose and color detail
10.LX 1 and LX 2 CS Parnels exact spacing will be
determined during focus.
11.LX 4 Cyc units are based on theatre inventory.
12.FOH 2 is not drawn in position.
13.Mini 10s are spaced 1' apart
This drawing represents visual concepts only. The Lighting
designer is not qualified or required to determine the
electrical or structural qualities of the design and will not
assume responsibility for improper engineering,
construction, or use. All materials and construction must
meet the most current local safety and fire codes.
If there are questions pertaining to the project that requires
communication with the Lighting designer. Please feel free to
contact via Phone or E-mail.
Drawing No.
Scale
DirectorSet Designer
Drawn By
Venue
Date
Contact
1
1/4" = 1'- 0"
Justin AndersonShannon Robert
Isaac Winston
Rialto Center for the Performing Arts Center
08/22/16
Tel. 347-724-3640
1
of
Drawing Title
Production Title
In The Hieghts
Music and Lyrics by Lin-Manuel Miranda
Book by Quiara Alegría Hudes
Light Plot
Lighting Designer M.C.Fusté
Instruments
Source 4 26deg
w575
Spot Movers
w575
Source 4 36
w575
Source 4
PARNEL
w575
3 cell CycAltman MR 16
Legend
Unit Number
Channel
Source 4 19deg
w575 Template
Degree
32
5
64MFL
Par 64 Medium Flood
w1000
Mini 10
w500 Accessories
Template Iris
Chauvet Rogue
R2 Wash
Source 4 50deg
w575
	
  
Vectorworks Educational Version
Vectorworks Educational Version

Weitere ähnliche Inhalte

Andere mochten auch

โครงร่างงานคอมพิวเตอร์
โครงร่างงานคอมพิวเตอร์โครงร่างงานคอมพิวเตอร์
โครงร่างงานคอมพิวเตอร์Kachon46592
 
328 mihaela povijač 7.b sigurnost na internetu
328 mihaela povijač 7.b sigurnost na internetu328 mihaela povijač 7.b sigurnost na internetu
328 mihaela povijač 7.b sigurnost na internetuPogled kroz prozor
 
Create a Bot with Delphi and Telegram - ITDevCon 2016
Create a Bot with Delphi and Telegram - ITDevCon 2016Create a Bot with Delphi and Telegram - ITDevCon 2016
Create a Bot with Delphi and Telegram - ITDevCon 2016Marco Breveglieri
 
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...IOSR Journals
 

Andere mochten auch (8)

Presentation1.PPTX
Presentation1.PPTXPresentation1.PPTX
Presentation1.PPTX
 
Visitas das férias
Visitas das fériasVisitas das férias
Visitas das férias
 
Presentation_NEW.PPTX
Presentation_NEW.PPTXPresentation_NEW.PPTX
Presentation_NEW.PPTX
 
โครงร่างงานคอมพิวเตอร์
โครงร่างงานคอมพิวเตอร์โครงร่างงานคอมพิวเตอร์
โครงร่างงานคอมพิวเตอร์
 
Taller de algoritmos secuenciales
Taller de algoritmos secuencialesTaller de algoritmos secuenciales
Taller de algoritmos secuenciales
 
328 mihaela povijač 7.b sigurnost na internetu
328 mihaela povijač 7.b sigurnost na internetu328 mihaela povijač 7.b sigurnost na internetu
328 mihaela povijač 7.b sigurnost na internetu
 
Create a Bot with Delphi and Telegram - ITDevCon 2016
Create a Bot with Delphi and Telegram - ITDevCon 2016Create a Bot with Delphi and Telegram - ITDevCon 2016
Create a Bot with Delphi and Telegram - ITDevCon 2016
 
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...
Evaluation of the Biochemical Composition of Four Marine Algae and Its Nutrit...
 

Rialto Theatre Light Plot 8.22.16

  • 1. Dead Hung (25'-8") Dead Hung (25'-10") Trough #4 Trough #3 Trough #2 Trough #1 LX 1 LX 2 LX 3 FOH 1 FOH 2 1'0" 2'0" 3'0" 4'0" 5'0" 6'0" 7'0" 8'0" 9'0" 10'0" 11'0" 12'0" 13'0" 14'0" 15'0" 16'0" 17'0" 18'0" 19'0" 20'0" 21'0" 22'0" 23'0" 24'0" 25'0"1'0"2'0"3'0"4'0"5'0"6'0"7'0"8'0"9'0"10'0"11'0"12'0"13'0"14'0"15'0"16'0"17'0"18'0"19'0"20'0"21'0"22'0"23'0"24'0"25'0" 1'0" 2'0" 3'0" 4'0" 5'0" 6'0" 7'0" 8'0" 9'0" 10'0" 11'0" 12'0" 13'0" 14'0" 15'0" 16'0" 17'0" 18'0" 19'0" 20'0" 21'0" 22'0" 23'0" 24'0" 25'0"1'0"2'0"3'0"4'0"5'0"6'0"7'0"8'0"9'0"10'0"11'0"12'0"13'0"14'0"15'0"16'0"17'0"18'0"19'0"20'0"21'0"22'0"23'0"24'0"25'0" CL CL Boom DSLBoom DSR Floor Mount USL LX 4 LPLP Floor Mount USR FOH 2Balcony Rail No 1 Torm HR No 1 Torm HL No 2 Torm HL Not shown in position Not shown in position Not shown in position Not shown in position No 2 Torm HR Ground Row Floor Mount DS 15 23 13 109 11 22 10 4 8 21 7 105 5 3 4 20 19 24 20 5 25 6 22 25 23 110 26 26 8 114 11 29 10 33 12 113 14 34 15 30 17 66 19 31 20 67 6 28 5 32 3 72 4 27 12 36 10 60 9 35 8 70 7 59 4 77 2 80 14 68 15 37 16 71 17 68 18 61 19 74 64MFL 4 88 64MFL 2 91 64MFL 1 90 64MFL 16 85 6 105 1 72 14 106 4 40 3 50 2 46 1 45 6 41 8 52 9 112 5 39 13 42 27 107 64MFL 3 89 64MFL 14 86 1 95 2 96 3 97 4 97 1100 2101 3102 4102 2'-0" 3'-0" 1'-0" 1'-0" 3'-0" 2'-0" 1'-0" 1'-0" 17 133 9 136 16 117 9 116 23 131 3 285 1 142 1 143 3 136 21 133 2 262 1 260 29 260 28 262 7 54 2 53 13 54 18 55 16 55 22 286 1 38 6 120 5 120 4 120 3 120 2 120 1 120 7 120 8 120 9 120 10 120 11 120 21 272 20 277 11 278 13 273 6 272 5 277 5 275 7 270 C6 C5 C4 C3 C2 C1 B6 B5 B4 B3 B2 B1 A6 A5 A4 A3 127 A2 128 A1 129 D6 D5 D4 D3 D2 D1E6 E5 E4 E3 E2 E1 6 138 12 139 8 271 7 276 10 276 11 27164MFL 15 266 24 268 Not shown in position 12 10 18 11 58 464 165 383 284 612 1133 2134 3283 4284 6 7 5 9 4 62 3 63 2 81 1 82 4 137 3 137 2 281 1 282 A3 123 A2 124 A1 125 B3 B2 B1C3 C2 C1D3 D2 D1E3 E2 E1 General Notes 1. Units are Space 18" apart Typical unless otherwise noted. 2. Electrics are marked every 18" from center 3. FOH Positions may not be drawn in position. 4. Cyc Units, Ground Units, and MR 16 strips spacing will be determined during focus. 5. Floor Mounts and Booms will be marked during focus. 6. Boom units are attached to side arms and measured from center of units. 7. Boom placement will be determined during focus. 8. Trim heights will be determined during focus. 9. Due to spacing, Use paperwork to get units purpose and color detail 10.LX 1 and LX 2 CS Parnels exact spacing will be determined during focus. 11.LX 4 Cyc units are based on theatre inventory. 12.FOH 2 is not drawn in position. 13.Mini 10s are spaced 1' apart This drawing represents visual concepts only. The Lighting designer is not qualified or required to determine the electrical or structural qualities of the design and will not assume responsibility for improper engineering, construction, or use. All materials and construction must meet the most current local safety and fire codes. If there are questions pertaining to the project that requires communication with the Lighting designer. Please feel free to contact via Phone or E-mail. Drawing No. Scale DirectorSet Designer Drawn By Venue Date Contact 1 1/4" = 1'- 0" Justin AndersonShannon Robert Isaac Winston Rialto Center for the Performing Arts Center 08/22/16 Tel. 347-724-3640 1 of Drawing Title Production Title In The Hieghts Music and Lyrics by Lin-Manuel Miranda Book by Quiara Alegría Hudes Light Plot Lighting Designer M.C.Fusté Instruments Source 4 26deg w575 Spot Movers w575 Source 4 36 w575 Source 4 PARNEL w575 3 cell CycAltman MR 16 Legend Unit Number Channel Source 4 19deg w575 Template Degree 32 5 64MFL Par 64 Medium Flood w1000 Mini 10 w500 Accessories Template Iris Chauvet Rogue R2 Wash Source 4 50deg w575   Vectorworks Educational Version Vectorworks Educational Version