Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for Grid application

IOSR Journals
IOSR JournalsInternational Organization of Scientific Research (IOSR)

http://www.iosrjournals.org/iosr-jeee/pages/v8i4.html

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
e-ISSN: 2278-1676,p-ISSN: 2320-3331, Volume 8, Issue 4 (Nov. - Dec. 2013), PP 43-53
www.iosrjournals.org
www.iosrjournals.org 43 | Page
Mathematical Modelling of PV Module With multilevel 3-Ø
inverter using SPWM technique for Grid application
Lunavath Hemsingh1
1
(Power Electronics & Automation, Neyveli Lignite Corporation Ltd, Tamilnadu, India)
Abstract : This paper presents a simple step-by-step procedure for the simulation of photovoltaic modules with
Matlab/ Simulink as well as Grid connected system for considering Three phase multistring inverter with
sinusoidal pulse width modulation control scheme. The single -diode equivalent circuit is employed in order to
Investigate I-V and P-V characteristics of a solar module. This paper focuses on a Matlab/SIMULINK model of
a photovoltaic cell and Grid connected system, considering three phase multistring inverter with SPWM control
scheme to reduce harmonics in primary side and same was applied to grid with prediction of PV cell behaviour
under different physical and environmental parameters. The PV model is based on mathematical equations and
is described through an equivalent circuit including a photocurrent source, a diode, a series resistor and a
shunt resistor. The developed model can also be used to extract the physical parameters for a given solar PV
cell as a function of temperature and solar radiation. Three PV strings are cascaded together in parallel
configuration and connected to a five-level inverter to produce output voltage in five levels of Vdc. That was
equivalent to the amplitude of the triangular carrier signal were used to generate PWM signals for the switches.
The inverter offers much less total harmonic distortion and can operate at near-unity power factor.
Keywords: DC-DC Converter, Multilevel Inverter, PV Module, SPWM, proportional–integral (PI) current
control, multistring.
I. Introduction
Solar energy in one form or another is the source of nearly all energy on the earth. Humans, like all
other animals and plants, rely on the sun for warmth and food. However, people also harness the sun's energy in
many other different ways. For example, fossil fuels, plant matter from a past geological age, is used for
transportation and electricity generation and is essentially just stored solar energy from millions of years ago.
Similarly, biomass converts the sun's energy into a fuel, which can then be used for heat, transport or electricity.
Wind energy, used for hundred of years to provide mechanical energy or for transportation, uses air currents that
are created by solar heated air and the rotation of the earth. Even hydroelectricity is derived from the sun.
Hydropower depends on the evaporation of water by the sun, and its subsequent return to the Earth as rain to
provide water in dams. Photovoltaic (often abbreviated as PV) are a simple and elegant method of harnessing
the sun's energy. PV devices (solar cells) are unique in that they directly convert the incident solar radiation into
electricity, with no noise, pollution or moving parts, making them robust, reliable and long lasting. Solar cells
are based on the same principles and materials behind the communications and computer revolutions, and this
CDROM covers the operation, use and applications of photovoltaic devices and systems.
Fig1.Basic solar energy conversion system
A solar cell is an electronic device which directly converts sunlight into electricity. Light shining on
the solar cell produces both a current and a voltage to generate electric power. This process requires firstly, a
material in which the absorption of light raises an electron to a higher energy state, and secondly, the movement
of this higher energy electron from the solar cell into an external circuit. The electron then dissipates its energy
in the external circuit and returns to the solar cell. A variety of materials and processes can potentially satisfy
the requirements for photovoltaic energy conversion, but in practice nearly all photovoltaic energy conversion
uses semiconductor materials in the form of a p-n junction.
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 44 | Page
Mathematical modelling of PV module is being continuously updated to enable researcher to have a
better understanding of its working [1-6].In this paper, a step-by-step procedure for simulating PV module with
simple subsystem blocks, with user-friendly icons and dialog in the same way as Matlab/ Simulink block
libraries is developed. The step-by-step modelling procedure of PV module as well as DC/DC converter, PWM
inverter through connected to Grid is presented with simulation results for different conditions of irradiation.
Photovoltaic systems require interfacing power converters between the PV arrays and the grid. These
power converters are used for two major tasks. First, to ensure that the PV arrays are operated at the maximum
power point (MPPT) [2-7]. Second, to inject a sinusoidal current into the grid. Normally there are two power
converters [8]. The first one is a DC/DC power converter. that is used to operate the PV arrays at the maximum
power point. The other one is a DC/AC power converter to interconnect the photovoltaic system to the grid. The
classical single or three-phase two level voltage source inverter is normally used for this power converter type
[9-12]. However, other topologies have been proposed. Multilevel converter topologies are a very interesting
choice for realizing this objective.
There are several PV system configurations. These configurations are the centralized technology, string
technology, multi-string technology and AC-module technology. The number and type of power converters that
is used to interconnect the PV system to the grid is dependent of the technology that is used. The multi-string
technology has several different groups of PV arrays. Each group is connected in series with a DC/DC
converter. This allows using this technology with some multilevel topologies, such as, the cascaded multicell
inverters. This topology is based on the series connection of single-phase inverters with separated DC sources.
In this way, each group of PV arrays will be used as a single DC source. This allows avoiding high voltage
amplification. In order to obtain a galvanic connection between the grid and the PV generator many PV systems
use a power transformer, avoiding that a leakage current may flow through the capacitance between PV
generator and ground. Some systems use a transformer embedded in a high-frequency DC/DC converter. Others
use a line frequency transformer at the output of the inverter.
Fig.2 PV modules connected to grid via Multilevel inverter
This mechanism proposes a three -phase multistring five-level inverter topology. It consists of three
strings of PV arrays connected to their own dc–dc boost converter. An auxiliary circuit comprising four diodes
and a switch is configured together with a conventional full-bridge inverter to form this topology. A SPWM
control scheme is introduced to generate switching signals for the switches and to produce five output-voltage
levels: zero, +1/2Vdc, Vdc, -1/2Vdc, and -Vdc (assuming that Vdc is the supply voltage). This inverter topology
uses two reference signals instead of one to generate PWM signals for the switches. Both reference signals
Vref1 and Vref2 are identical to each other, except for an offset value that is equivalent to the amplitude of
carrier signal Vcarrier. Because the inverter is used in a PV system, a proportional–integral (PI) current control
scheme is employed to keep the output current sinusoidal and to have high dynamic performance under rapidly
changing atmospheric conditions and to maintain the power factor at near unity. Simulation and experimental
results are presented to validate the proposed inverter configuration.
II. Mathematical Model For Pv Module
A solar cell is basically a p-n junction fabricated in a thin wafer of semiconductor. The electromagnetic
radiation of solar energy can be directly converted to electricity through Photovoltaic effect. Being exposed to
the sunlight, photons with energy greater then the band-gap energy of the semiconductor creates some electron-
hole pairs proportional to the incident irradiation.
Fig.3: Equivalent diagram of PV cell
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 45 | Page
A model of PV module with moderate complexity that includes the temperature independence of the
photocurrent source, the saturation current of the diode, and a series
Resistance is considered based on the Shockley diode equation.
The current source Iph represents the cell photocurrent. Rsh and Rs are the intrinsic shunt and series
resistances of the cell, respectively. Usually the value of Rsh is very large and that of Rs is very small, hence
they may be neglected to simplify the analysis. PV cells are grouped in larger units called PV modules which
are further interconnected in a parallel-series configuration to form PV arrays.
The photovoltaic panel can be modelled mathematically as given in equations (1)- (4) [3] – [5]. Module photo-
current:
𝐼𝑝𝑕 = 𝐼𝑆 𝐶𝑟 + 𝐾𝑖 𝑇 − 298 ∗
𝜆
1000
(𝑖)
Modules reverse saturation current - Irs:
𝐼𝑟𝑠 = 𝐼𝑆𝐶𝑟 /[exp
𝑞𝑉𝑂𝐶
𝑁𝑠 𝑘𝐴𝑇
− 1] (𝑖𝑖)
The module saturation current I0 varies with the cell temperature, which is given by
𝐼 𝑂 = 𝐼𝑟𝑠
𝑇
𝑇𝑟
∗ [exp
𝑞 ∗ 𝑉𝑔𝑜
𝐵𝑘
1
𝑇𝑟
−
1
𝑇
− 1] (𝑖𝑖𝑖)
The current output of PV module is
𝐼 𝑃𝑉 = 𝑁𝑃 ∗ 𝐼𝑝𝑕 − 𝑁𝑃 ∗ 𝐼𝑜 [exp
𝑞 ∗ (𝑉𝑃𝑉 + 𝐼 𝑃𝑉 𝑅𝑆
𝑁𝑆 𝐴𝑘𝑇
− 1] (𝑖𝑣)
Where Vpv = Voc, Np = 1 and Ns = 36
PV module represents the fundamental power conversion unit of a PV generator system. The output
characteristics of a PV module depend on the solar insolation, the cell temperature and the output voltage of the
PV module. Since PV module has nonlinear characteristics, it is necessary to model it for the design and
simulation of maximum power point tracking (MPPT) for PV system applications.
The above mentioned equations are modelled by using common Simulink blocks as shown below fig:3
a. Subsystem 1 is shown in Figure 4. This model converts the module operating temperature given in degrees
Celsius to Kelvin.
b. subsystem 2 This model calculates the short circuit current ( ISC) at given operating temperature. Figure 4
gives the circuit under subsystem.
c. Subsystem 3 is shown in Figure 4. This model takes short circuit current ISC at reference temp. = 2.55A and
Module reference temperature TrK = 25oC as input.
d. Subsystem 4 This model takes reverse saturation current Irs, Module reference temperature TrK = 250 C and
Module operating temperature TaK as input and calculates module saturation current.
e. This model takes operating temperature in Kelvin TaK and calculates the product NsAkT, the denominator of
the exponential function in equation (4).
f. This model executes the function given by the equation (4). The following function equation is used. This
gives the circuit under subsystem 6.
IPV = u(3)-u(4)*(exp((u(2)*(u(1)+u(6)))/(u(5)))-1)
All the above six subsystem models are interconnected in such a way that to produce PV current at
corresponding voltage.
Fig.4 Interconnected Simulink model for all equations sub systems
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 46 | Page
The final model takes irradiation; operating temperature in Celsius and module voltage as input and gives the
output current Ipv and output voltage Vpv and Rated Power Ppv.The workspace is added to measure Ipv, Vpv,
and Ppv in this model.
III. Modelling Of Multistring Five-Level Inverter Topology
The proposed Three-phase multistring five-level inverter topology is shown in Fig. 5. It consists of three
dc–dc boost converters connected to a common dc bus, an auxiliary circuit, and a full-bridge inverter
configuration. Input sources, PV string 1, PV string 2, and PV string 3 are connected to the inverter via the dc–
dc boost converters. Because the proposed inverter is used in a grid-connected PV system, the utility grid is used
instead of a load. The dc–dc boost converters are used to track the maximum power point (MPP) independently
and to step up inverter output voltage Vinv to be more than √2 of grid voltage Vg to ensure power flow from the
PV arrays into the grid [12].
𝑉𝑖𝑛 > 2
𝑉𝑔
2𝑉 𝑖𝑛
(v)
The dc–dc boost converters are connected in parallel to avoid high dc-bus voltage, which will eventually
increase the size of the capacitors and the inverter’s cost. Therefore, only two capacitors with equal capacitance
rating are used as the dc bus, and the other dc–dc boost converters are connected to this dc bus, as shown in Fig.
5.
Fig.5: Proposed approach of multilevel inverter
Fig.6: Equivalent model of Pv module connected to grid
A filtering inductance Lf is used to filter the current injected into the grid. The injected current must be
sinusoidal with low harmonic distortion. In order to generate sinusoidal current, a sinusoidal PWM is used
because it is one of the most effective methods. A sinusoidal PWM is obtained by comparing a high frequency
carrier signal with a low-frequency sinusoid signal, which is the modulating or reference signal. The carrier has
PV MODULE DC/DC
CONVERTER
LOAD/GRID
PWM
GENERATOR
PI
CONTROLLER
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 47 | Page
a constant period; therefore, the switches have constant switching frequency. The switching instant is
determined from the crossing of the carrier and the modulating signal.
Modulation index Ma for a five-level PWM inverter is given as [13-14]
𝑀𝑎 =
𝐴 𝑚
2𝐴 𝑐
(vii)
where Ac is the peak-to-peak value of carrier and Am is the peak value of voltage reference Vref . Because, in
this paper, two reference signals that are identical to each other are used, (vii) can be expressed in terms of the
amplitude of carrier signal Vc by replacing Ac with Vc, and Am = Vref1 = Vref2 = Vref
.
𝑀 =
𝑉𝑟𝑒𝑓
2𝑣𝑐
(𝑣𝑖𝑖𝑖)
From the PWM modulation, the analysis of harmonic components in the proposed inverter can be preformed.
The output voltage produced by comparison of the two reference signals and the carrier signal can be expressed
as [7]
𝑉0 𝜃 = 𝐴0 + (𝐴 𝑛 𝑐𝑜𝑠𝑛𝜃 + 𝐵𝑛 𝑠𝑖𝑛𝑛𝜃)
∞
𝑛=1
(𝑖𝑥)
If there are P pulses per quarter period, and it is an odd number, coefficients Bn and Ao would be zero, where n
is an even number. Therefore, the (ix) can be rewritten as
𝑉0 𝜃 = 𝐴 𝑛 𝑐𝑜𝑠𝑛𝜃
∞
𝑛=1
(𝑥)
𝐴 𝑛 = −
2𝑉 𝑑𝑐
𝑛𝜋
[(−1)𝑖𝑛𝑡 (
𝑖
2
)4
𝑖=1
𝑃
𝑚=0 sin⁡(𝑛𝛼 𝑚+𝑖)] (𝑥𝑖)
Fig.7: carrier and reference signal for modulation index M=0.5
where m is a pulse number and α is the phase displacement angle. The Fourier series coefficients of the
conventional single phase full-bridge inverter by sinusoidal PWM is given as
𝐴 𝑛 = −
𝑉𝑑𝑐
𝑛𝜋
[ −1 𝑚
𝑝
𝑚=1
sin⁡(𝑛𝛼 𝑚 )] (𝑥𝑖𝑖)
Combinations of PV strings are used as the input voltage sources. The voltage across the strings are known as
Vpv1, Vvp2, and Vpv3. Referring to (1) and (2), Vpv1, Vvp2, and Vvp3 are boosted by the dc–dc boost
converters to exceed grid voltage Vg, and the voltage across the dc bus is known as Vpv. The operating principle
of the proposed inverter is to generate five output-voltage levels, i.e., 0, +Vpv/2, +Vpv, −Vpv/2, −Vpv, as in Fig.
8. As shown in Fig. 5, an auxiliary circuit that consists of four diodes and a switch S4 is used between the dc-
bus capacitors and the full-bridge inverter. Proper switching control of the auxiliary circuit can generate half
level of PV supply voltage, i.e., +Vpv/2 and -Vpv/2 [15-17].
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 48 | Page
Fig. 8. Inverter output voltage (Vinv) and switching pattern for the five-level inverter
Two reference signals Vref1 and Vref2 will take turns to be compared with the carrier signal at a time. If Vref1
exceeds the peak amplitude of carrier signal Vcarrier, then Vref2 will be compared with the carrier signal until it
reaches zero. At this point onward, Vref1 takes over the comparison process until it exceeds Vcarrier. This will
lead to a switching pattern, as shown in Fig. 8. Switches S4–S6 will be switching at the rate of the carrier signal
frequency, while S7 and S8 will operate at a frequency that is equivalent to the fundamental frequency. Table I
illustrates the level of Vinv during S4–S8 switch on and off. If one of the PV strings is disconnected from the dc
bus, the operation of the other dc–dc boost converters will not be affected because they are connected in
parallel. As the dc–dc boost converters are used to track the MPPT point, it can be concluded that the MPPT of
the PV strings is done independently. Later expansion of the PV strings is also possible by adding a dc–dc boost
converter, as shown in Fig. 5.
TABLE I
Inverter Output Voltage during S4–S8 switch ON and OFF
S4 S5 S6 S7 S8 Vinv
1 0 0 0 1 +Vpv2
0 1 0 0 1 +Vpv
0
1
0
0
1
1
0
0
1
0
1 0 0 1 0 -Vpv2
0 0 1 1 0 -Vpv
IV. Simulation Results And Discussion
(a) PV Module
Fig.9: Simulink model of PV module with workspace
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 49 | Page
With the developed model, the PV module characteristic is estimated as follows.
(1) I-V and P-V characteristics under varying irradiation with constant temperature are obtained as shown in
Figures 9(a) to 9(d). Between 0 and 1 s, the irradiation is 200W/m2, between 1 and 2 s it is 600 W/m, while
from 2 s onwards it is 1000W/m2.
2. In Figure 9(b), the input temperature is shown which is constant at25 𝑂𝐶.
Fig.9 (a) Insolation at different levels
Fig.9 (b) Constant temperature input
3. The I-V and P-V output characteristics of PV module with varying irradiation at constant temperature are
shown in Figure 9(c) and 9(d).
Fig 9(c). Output – I-V characteristics with varying
irradiation
Fig 9(d). Output – P-V characteristics with varying
irradiation
From the above plots we can conclude that, when the irradiation increases,
A. The current output increases
B.The voltage output also increases. This results in net increase in power output with increase in irradiation
at constant temperature.
II. I-V and P-V Characteristics under constant irradiation with varying temperature are obtained in Figures 10(a)
to 10(d).
1. In Figure 10(a) the time varying temperature signal is shown. Between 0 and 1 second, the temperature of 25
C is applied and it is increased to 50 and 750C.
Fig 5(a). Input – Time varying temperature
0 1 2 3 4 5 6 7 8 9 10
0
0.2
0.4
0.6
0.8
1
1.2
1.4
INSOLATION
Time (sec)
untitled/Signal Builder : Group 1
0 1 2 3 4 5 6 7 8 9 10
24
24.2
24.4
24.6
24.8
25
25.2
25.4
25.6
25.8
26
Temperature
Time (sec)
untitled/Signal Builder : Group 1
0 5 10 15 20 25
0
0.5
1
1.5
2
2.5
3
PV Voltage(Vpv)
PVCurrent(Ipv)
V-I CHARACTERISTICS OF PV MODEL
1000W/m2
600W/m2
200W/m2
0 5 10 15 20 25
0
5
10
15
20
25
30
35
40
45
PV Voltage(Vpv)
PVPower(Ppv)
P-V CHARACTERISTICS OF PV MODEL
1000 W/m2
600 W/m2
200 W/m2
0 1 2 3 4 5 6 7 8
0
10
20
30
40
50
60
70
80
TEMPERATURE
Time (sec)
untitled/Signal Builder : Group 1
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 50 | Page
2. The I-V output characteristics of PV module with varying temperature at constant irradiation of 1000W/m2
are shown in Figure 10(b).
Figure 10(b). Output – I-V characteristics with varying temperature
3. The P-V output characteristics of PV module with varying temperature at constant irradiation are shown in
Figure 10(c).
Figure 10(c). Output – P-V characteristics with varying temperature
From above Case-ii we can conclude that, when the operating temperature increases,
A. The current output increases marginally, but the voltage output decreases drastically
B.Results in net reduction in power output with rise in temperature
The results are verified and found matching with the manufacturer’s data sheet output curves.
(b) GRID Connected system
Simulations were performed by using MATLAB/Simulink to verify that the proposed inverter can
practically be implemented in a PV system. It helps one to confirm the PWM switching strategy for the
multistring five-level inverter. Then, this strategy is implemented in a real-time environment, i.e., the DSP to
produce PWM switching signals for the switches. Fig. 10(a) shows the way the PWM switching signals are
generated by using two reference signals and a triangular carrier signal. The resulting PWM signals for switches
S4–S8 are shown in Fig. 10(b)–(f). Note that one leg of the inverter is operating at a high switching rate that is
equivalent to the frequency of the carrier signal, while the other leg is operating at the rate of fundamental
frequency (i.e., 50 Hz). The switch at the auxiliary circuit (S4) also operates at the rate of the carrier signal. As
mentioned earlier, modulation index M will determine the shape of inverter output voltage Vinv and grid current
Ig. Fig. 11 shows the simulation results of Vinv and Ig for different values of M. The dc-bus voltage is set to 200
V.
Below figures shows that the power generated from Photo voltaic modules are collected as a DC
source of low voltage ,thus generated voltage was step up by using DC-DC converters as a 200V .The voltage
produced by converter is not AC source, to convert DC to Alternating current we used here a Inverter consisting
of Sinusoidal Pulse width Modulation. The Harmonics generated by the source is very less and power factor is
almost near by unity.
0 2 4 6 8 10 12 14 16 18
1.6
1.8
2
2.2
2.4
2.6
PV Voltage(Vpv)
PVCurrent(Ipv)
V-I CHARACTERISTICS OF PV MODEL CONSTANT INSOLATION 1000W/m2
Tref 25 oC
Tref 50 oC
Tref 75 oC
0 5 10 15 20 25
0
5
10
15
20
25
30
35
40
45
PV Voltage(Vpv)
PVPower(Ppv)
P-V CHARACTERISTICS AT CONSTANT INSOLATION 1000 W/m2
Tref 25 oC
Tref 50 oC
Tref 75 oC
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 51 | Page
Fig.11: Multilevel inverter for three phase system
Fig.12: Simulink block with PV and control strategy of Grid system
Fig.12(a).Reference and carrier signal generation
Fig.12 (b).Inverter output voltage i.e. grid connected voltage
0 0.005 0.01 0.015 0.02 0.025
-20
-10
0
10
20
30
40
Amplitude
Time(S)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17
-200
-150
-100
-50
0
50
100
150
200
Time(s)
PhaseVoltage(V)
INVERTER OUTPUT VOLTAGE(GRID VOLTAGE)
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 52 | Page
Fig.12(c).Inverter output current i.e. grid current
Fig.12(d).FFT analysis of grid connected system_R_ Phase
VII. Conclusion
This paper has presented the step-by-step procedure for modelling the PV module is presented with
three-phase multistring five-level inverter for PV application. This mathematical modelling procedure serves as
an aid to induce more people into photovoltaic research and gain a closer understanding of I-V and P-V
characteristics of PV module. A novel PWM control scheme with two reference signals and a carrier signal has
been used to generate the PWM switching signals. The circuit topology, control algorithm, and operating
principle of the proposed inverter have been analysed in detail. The configuration is suitable for PV application
as the PV strings operate independently and later expansion is possible. Furthermore, the experimental results
indicate that the THD of the multistring five-level inverter is much less than that of the conventional multistring
three-level inverter. In addition, both grid voltage and grid current are in phase at near-unity power factor.
References
Proceedings Papers:
[1 ] M.Veerachary, “Power Tracking for Nonlinear PV Sources with Coupled Inductor SEPIC Converter,” IEEE Transactions on
Aerospace and Electronic Systems, vol. 41, No. 3, July 2005.
[2] I. H. Altas and A.M. Sharaf, “A Photovoltaic Array Simulation Model for Matlab-Simulink GUI Environment,” IEEE, Clean
Electrical Power, International Conference on Clean Electrical Power (ICCEP '07), June 14-16, 2007, Ischia, Italy.
[3] S.Chowdhury, S.P.Chowdhury, G.A.Taylor, and Y.H.Song, “Mathematical Modelling and Performance Evaluation of a Stand-
Alone Polycrystalline PV Plant with MPPT Facility,” IEEE Power and Energy Society General Meeting - Conversion and Delivery
of Electrical Energy in the 21st Century, July 20-24, 2008, Pittsburg, USA.
[4] Jee-Hoon Jung, and S. Ahmed, “Model Construction of Single Crystalline Photovoltaic Panels for Real-time Simulation,” IEEE
Energy Conversion Congress & Expo, September 12-16, 2010, Atlanta, USA.
[5] S. Nema, R.K.Nema, and G.Agnihotri, “Matlab / Simulink based study of photovoltaic cells / modules / array and their
experimental verification,” International Journal of Energy and Environment, pp.487- 500, Volume 1, Issue 3, 2010.
[6] N. A. Rahim and S. Mekhilef, “Implementation of three-phase grid connected inverter for photovoltaic solar power generation
system,” in Proc. IEEE PowerCon, Oct. 2002, vol. 1, pp. 570–573.
0.02 0.03 0.04 0.05 0.06 0.07 0.08
-10
-5
0
5
10
Time(s)
Gridcurrent(A)
GRID CURRENT
Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application
www.iosrjournals.org 53 | Page
Journal Papers:
[7] Aryuanto Soetedjo*, Abraham Lomi, Yusuf Ismail Nakhoda, Awan Uji Krismanto, “Modelling of Maximum Power Point Tracking
Controller for Solar Power System: TELKOMNIKA, , pp. 419~430 e-ISSN: 2087-278X.,Vol.10, No.3, July 2012.
[8] V. Fernão Pires*, J. F. Martins**, D. Foito*, Chen Hão , “ A Grid Connected Photovoltaic System with a Multilevel Inverter and a
Le-Blanc Transformer,” INTERNATIONAL JOURNAL of RENEWABLE ENERGY RESEARCH Vitor Fernão Pires et al., Vol.2,
No.1, 2012.
[9] Alias Khamis, Mohamed,H. Shareef,A. Ayob” Modelling and simulation of a micro grid tested using photovoltaic and battery
based power generation” Journal of Asian Scientific Research 2(11):658-666
[10] Tarak Salmi*, Mounir Bouzguenda**, Adel Gastli**, Ahmed Masmoudi* “MATLAB/Simulink Based Modelling of Solar
Photovoltaic Cell,” INTERNATIONAL JOURNAL of RENEWABLE ENERGY RESEARCH Tarak Salmi et al., Vol.2, No.2, 2012.
[11] M. Meinhardt and G. Cramer, “Past, present and future of grid-connected photovoltaic- and hybrid-power-systems,” in Proc. IEEE-
PES Summer Meeting, Jul. 2000, vol. 2, pp. 1283–1288.
Proceedings Papers:
[12] S. Kouro, J. Rebolledo, and J. Rodriguez, “Reduced switching-frequency modulation algorithm for high-power multilevel
inverters,” IEEE Trans. Ind. Electron., vol. 54, no. 5, pp. 2894–2901, Oct. 2007.
[13] S. J. Park, F. S. Kang, M. H. Lee, and C. U. Kim, “A new single-phase five level PWM inverter employing a deadbeat control
scheme,” IEEE Trans. Power Electron., vol. 18, no. 18, pp. 831–843, May 2003.
[14] L. M. Tolbert and T. G. Habetler, “Novel multilevel inverter carrier-based PWM method,” IEEE Trans. Ind. Appl., vol. 35, no. 5,
pp. 1098–1107, Sep./Oct. 1999.
[15] Y. Liu, H. Hong, and A. Q. Huang, “Real-time calculation of switching angles minimizing THD for multilevel inverters with step
modulation,” IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 285–293, Feb. 2009.
[16] N. S. Choi, J. G. Cho, and G. H. Cho, “A general circuit topology of multilevel inverter,” in Proc. IEEE 22th Annu. PESC, Jun. 24–
27, 1991, pp. 96–103.
[17] G. Carrara, S. Gardella, M. Marchesoni, R. Salutari, and G. Sciutto, “A new multilevel PWM method: A theoretical analysis,” IEEE
Trans. Power Electron., vol. 7, no. 3, pp. 497–505, Jul. 1992.
IX. NOMENCLATURE
Vpv is output voltage of a PV module (V)
Ipv is output current of a PV module (A)
Tr is the reference temperature = 298 K
T is the module operating temperature in Kelvin
Iph is the light generated current in a PV module (A)
Io is the PV module saturation current (A)
A = B is an ideality factor = 1.6
k is Boltz man constant = 1.3805 × 10-23 J/K
q is Electron charge = 1.6 × 10-19 C
Rs is the series resistance of a PV module
ISCr is the PV module short-circuit current at 25 oC at 1000W/m2 = 2.55A
Ki is the short-circuit current temperature co-efficient at ISCr = 0.0017A / oC
𝜆 is the PV module illumination (W/m2) = 1000W/m2
Ego is the band gap for silicon = 1.1 eV
Ns is the number of cells connected in series
Ma is Modulation index
Vout Inverter output voltage
Vg is Grid voltage,Ig is Grid current
Np is the number of cells connected in parallel.
Lunavath. Hemsingh was born in Andhra Pradesh, India, in 1988. He received the B.Tech
(EEE) degree from Jawaharlal Nehru Technological University, Hyderabad, India, in 2010,
The M.Tech. Degree in power and Energy systems from the National Institute of Technology
Karnataka, Surathkal, India in 2012 He is currently Working as a Asst.Execuitive Engineer
(Electrical) ,Power Electronics & Automation division in Neyveli Lignite Corporation Ltd
,Tamilnadu,India. His research interests are Power electronics and Automation of multilevel
inverters, PI current control techniques, photovoltaic inverters, and dc–dc converters.

Recomendados

A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi... von
A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi...A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi...
A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi...IJERA Editor
189 views5 Folien
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ... von
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...IRJET Journal
33 views10 Folien
Simulation of grid connected photovoltaic system using MATLAB/ Simulink von
Simulation of grid connected photovoltaic system using MATLAB/ SimulinkSimulation of grid connected photovoltaic system using MATLAB/ Simulink
Simulation of grid connected photovoltaic system using MATLAB/ SimulinkIJAEMSJORNAL
57 views6 Folien
1 s2.0-s187661021301103 x-main von
1 s2.0-s187661021301103 x-main1 s2.0-s187661021301103 x-main
1 s2.0-s187661021301103 x-mainAhmedAljabari
78 views12 Folien
Performance Investigation of Grid Connected Photovoltaic System Modelling Bas... von
Performance Investigation of Grid Connected Photovoltaic System Modelling Bas...Performance Investigation of Grid Connected Photovoltaic System Modelling Bas...
Performance Investigation of Grid Connected Photovoltaic System Modelling Bas...IJECEIAES
9 views8 Folien
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea... von
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...IRJET Journal
21 views4 Folien

Más contenido relacionado

Was ist angesagt?

C011141018 von
C011141018C011141018
C011141018IOSR Journals
155 views9 Folien
solar panel mathematical modelling using simulink von
solar panel mathematical modelling using simulinksolar panel mathematical modelling using simulink
solar panel mathematical modelling using simulinkgraphic era university
3.5K views6 Folien
Simulation of various DC-DC converters for photovoltaic system von
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemIJECEIAES
65 views9 Folien
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ... von
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...EECJOURNAL
24 views7 Folien
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us... von
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...irjes
577 views12 Folien

Was ist angesagt?(20)

Simulation of various DC-DC converters for photovoltaic system von IJECEIAES
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic system
IJECEIAES65 views
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ... von EECJOURNAL
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
EECJOURNAL24 views
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us... von irjes
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...
Implementation Of A High-Efficiency, High-Lifetime, And Low-Cost Converter Us...
irjes577 views
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta... von IDES Editor
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
IDES Editor1.1K views
Energy Storage Management in Grid Connected Solar Photovoltaic System von IJERA Editor
Energy Storage Management in Grid Connected Solar Photovoltaic SystemEnergy Storage Management in Grid Connected Solar Photovoltaic System
Energy Storage Management in Grid Connected Solar Photovoltaic System
IJERA Editor323 views
1 s2.0-s0038092 x18311939-main von AhmedAljabari
1 s2.0-s0038092 x18311939-main1 s2.0-s0038092 x18311939-main
1 s2.0-s0038092 x18311939-main
AhmedAljabari74 views
Measurement and Analysis of Power in Hybrid System von ijeei-iaes
Measurement and Analysis of Power in Hybrid SystemMeasurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid System
ijeei-iaes50 views
Low Voltage Energy Harvesting by an Efficient AC-DC Step-Up Converter von IOSR Journals
Low Voltage Energy Harvesting by an Efficient AC-DC Step-Up ConverterLow Voltage Energy Harvesting by an Efficient AC-DC Step-Up Converter
Low Voltage Energy Harvesting by an Efficient AC-DC Step-Up Converter
IOSR Journals689 views
Z - Source Multi Level Inverter Based PV Generation System von IJERA Editor
Z - Source Multi Level Inverter Based PV Generation SystemZ - Source Multi Level Inverter Based PV Generation System
Z - Source Multi Level Inverter Based PV Generation System
IJERA Editor598 views
PV Hybrid System with DSTATCOM for Residential Applications von IDES Editor
PV Hybrid System with DSTATCOM for Residential ApplicationsPV Hybrid System with DSTATCOM for Residential Applications
PV Hybrid System with DSTATCOM for Residential Applications
IDES Editor839 views
Design an electric vehicle using PV array with five phase permanent magnet sy... von ijtsrd
Design an electric vehicle using PV array with five phase permanent magnet sy...Design an electric vehicle using PV array with five phase permanent magnet sy...
Design an electric vehicle using PV array with five phase permanent magnet sy...
ijtsrd45 views
High Proficiency Grid ConnectedPhotovoltaic Power Generation System von IJRES Journal
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemHigh Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
IJRES Journal408 views

Destacado

a project report on MPPT algorithm for PV panel von
a project report on MPPT algorithm for PV panela project report on MPPT algorithm for PV panel
a project report on MPPT algorithm for PV panelgauravchitransh
40.2K views59 Folien
A transformerless grid connected photovoltaic inverter with switched capacitors von
A transformerless grid connected photovoltaic inverter with switched capacitorsA transformerless grid connected photovoltaic inverter with switched capacitors
A transformerless grid connected photovoltaic inverter with switched capacitorsAsoka Technologies
257 views6 Folien
Introduction to Pv cell von
Introduction to Pv cellIntroduction to Pv cell
Introduction to Pv cellAbdallah Yousef
2.9K views10 Folien
Sine Pulse Width Modulation Inverter von
Sine Pulse Width Modulation InverterSine Pulse Width Modulation Inverter
Sine Pulse Width Modulation InverterAditya Parmar
2.6K views12 Folien
Eliminating leakage current in single phase transformerless z source inverter... von
Eliminating leakage current in single phase transformerless z source inverter...Eliminating leakage current in single phase transformerless z source inverter...
Eliminating leakage current in single phase transformerless z source inverter...Hussain Ali
1.3K views28 Folien
photovoltaics cell pv cell solar cell von
photovoltaics cell pv cell solar cell photovoltaics cell pv cell solar cell
photovoltaics cell pv cell solar cell Gautam Singh
23.4K views28 Folien

Destacado(20)

a project report on MPPT algorithm for PV panel von gauravchitransh
a project report on MPPT algorithm for PV panela project report on MPPT algorithm for PV panel
a project report on MPPT algorithm for PV panel
gauravchitransh40.2K views
A transformerless grid connected photovoltaic inverter with switched capacitors von Asoka Technologies
A transformerless grid connected photovoltaic inverter with switched capacitorsA transformerless grid connected photovoltaic inverter with switched capacitors
A transformerless grid connected photovoltaic inverter with switched capacitors
Asoka Technologies257 views
Sine Pulse Width Modulation Inverter von Aditya Parmar
Sine Pulse Width Modulation InverterSine Pulse Width Modulation Inverter
Sine Pulse Width Modulation Inverter
Aditya Parmar2.6K views
Eliminating leakage current in single phase transformerless z source inverter... von Hussain Ali
Eliminating leakage current in single phase transformerless z source inverter...Eliminating leakage current in single phase transformerless z source inverter...
Eliminating leakage current in single phase transformerless z source inverter...
Hussain Ali1.3K views
photovoltaics cell pv cell solar cell von Gautam Singh
photovoltaics cell pv cell solar cell photovoltaics cell pv cell solar cell
photovoltaics cell pv cell solar cell
Gautam Singh23.4K views
Developers' New features of Sql server express 2012 von Ziaur Rahman
Developers' New features of Sql server express 2012Developers' New features of Sql server express 2012
Developers' New features of Sql server express 2012
Ziaur Rahman1.4K views
Tracking your emails with mailtracking.com von believe52
Tracking your emails with mailtracking.comTracking your emails with mailtracking.com
Tracking your emails with mailtracking.com
believe5258 views
The Golden Formula of Writing Article Easily von believe52
The Golden Formula of Writing Article EasilyThe Golden Formula of Writing Article Easily
The Golden Formula of Writing Article Easily
believe5283 views
Comparison Study of Lossless Data Compression Algorithms for Text Data von IOSR Journals
Comparison Study of Lossless Data Compression Algorithms for Text DataComparison Study of Lossless Data Compression Algorithms for Text Data
Comparison Study of Lossless Data Compression Algorithms for Text Data
IOSR Journals638 views
Презентация Ямпольского района - Проект приграничного сотрудничества Украина ... von Anastasia Lanina
Презентация Ямпольского района - Проект приграничного сотрудничества Украина ...Презентация Ямпольского района - Проект приграничного сотрудничества Украина ...
Презентация Ямпольского района - Проект приграничного сотрудничества Украина ...
Anastasia Lanina416 views
Double Key Encryption Method (DKEM) Algorithms Using ANN for Data Storing and... von IOSR Journals
Double Key Encryption Method (DKEM) Algorithms Using ANN for Data Storing and...Double Key Encryption Method (DKEM) Algorithms Using ANN for Data Storing and...
Double Key Encryption Method (DKEM) Algorithms Using ANN for Data Storing and...
IOSR Journals498 views
Area-Efficient VLSI Implementation for Parallel Linear-Phase FIR Digital Filt... von IOSR Journals
Area-Efficient VLSI Implementation for Parallel Linear-Phase FIR Digital Filt...Area-Efficient VLSI Implementation for Parallel Linear-Phase FIR Digital Filt...
Area-Efficient VLSI Implementation for Parallel Linear-Phase FIR Digital Filt...
IOSR Journals624 views
Looking back at your preliminary task, what von lisadors
Looking back at your preliminary task, whatLooking back at your preliminary task, what
Looking back at your preliminary task, what
lisadors183 views

Similar a Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for Grid application

H010425863 von
H010425863H010425863
H010425863IOSR Journals
200 views6 Folien
Pj3426922696 von
Pj3426922696Pj3426922696
Pj3426922696IJERA Editor
279 views5 Folien
Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP... von
Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...
Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...IJECEIAES
272 views9 Folien
International Journal of Engineering Research and Development von
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
283 views8 Folien
Mini_Project von
Mini_ProjectMini_Project
Mini_ProjectPratheek Rajan
673 views30 Folien
Modeling and Simulation of Solar Photovoltaic System von
Modeling and Simulation of Solar Photovoltaic SystemModeling and Simulation of Solar Photovoltaic System
Modeling and Simulation of Solar Photovoltaic Systemijtsrd
579 views5 Folien

Similar a Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for Grid application(20)

Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP... von IJECEIAES
Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...
Modeling and Simulation of Fuzzy Logic based Maximum Power Point Tracking (MP...
IJECEIAES272 views
International Journal of Engineering Research and Development von IJERD Editor
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
IJERD Editor283 views
Modeling and Simulation of Solar Photovoltaic System von ijtsrd
Modeling and Simulation of Solar Photovoltaic SystemModeling and Simulation of Solar Photovoltaic System
Modeling and Simulation of Solar Photovoltaic System
ijtsrd579 views
A Three Phase Multi Level Converter for grid Connected PV System von IAES-IJPEDS
A Three Phase Multi Level Converter for grid Connected PV SystemA Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV System
IAES-IJPEDS76 views
Simulation of incremental conductance mppt with direct control method using c... von eSAT Journals
Simulation of incremental conductance mppt with direct control method using c...Simulation of incremental conductance mppt with direct control method using c...
Simulation of incremental conductance mppt with direct control method using c...
eSAT Journals444 views
A Novel Analog Circuit Design For Maximum Power Point Tracking Of Photovoltai... von Kayla Jones
A Novel Analog Circuit Design For Maximum Power Point Tracking Of Photovoltai...A Novel Analog Circuit Design For Maximum Power Point Tracking Of Photovoltai...
A Novel Analog Circuit Design For Maximum Power Point Tracking Of Photovoltai...
Kayla Jones3 views
Open-Switch Fault-Tolerant Control of Power Converters in a Grid-Connected Ph... von IAES-IJPEDS
Open-Switch Fault-Tolerant Control of Power Converters in a Grid-Connected Ph...Open-Switch Fault-Tolerant Control of Power Converters in a Grid-Connected Ph...
Open-Switch Fault-Tolerant Control of Power Converters in a Grid-Connected Ph...
IAES-IJPEDS67 views
A. attou ajbas issn 1991-8178-pv mppt von Attou
A. attou ajbas issn 1991-8178-pv mpptA. attou ajbas issn 1991-8178-pv mppt
A. attou ajbas issn 1991-8178-pv mppt
Attou664 views
Real Time Implementation of Variable Step Size Based P&O MPPT for PV Systems ... von IJPEDS-IAES
Real Time Implementation of Variable Step Size Based P&O MPPT for PV Systems ...Real Time Implementation of Variable Step Size Based P&O MPPT for PV Systems ...
Real Time Implementation of Variable Step Size Based P&O MPPT for PV Systems ...
IJPEDS-IAES125 views
Parallel Operation of Current-Source Inverter for Low-Voltage High-Current Gr... von IJECEIAES
Parallel Operation of Current-Source Inverter for Low-Voltage High-Current Gr...Parallel Operation of Current-Source Inverter for Low-Voltage High-Current Gr...
Parallel Operation of Current-Source Inverter for Low-Voltage High-Current Gr...
IJECEIAES34 views
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy... von IOSR Journals
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
IOSR Journals354 views
A Simple Control Strategy for Boost Converter Based Wind and Solar Hybrid Ene... von IJRES Journal
A Simple Control Strategy for Boost Converter Based Wind and Solar Hybrid Ene...A Simple Control Strategy for Boost Converter Based Wind and Solar Hybrid Ene...
A Simple Control Strategy for Boost Converter Based Wind and Solar Hybrid Ene...
IJRES Journal836 views

Más de IOSR Journals

A011140104 von
A011140104A011140104
A011140104IOSR Journals
1.2K views4 Folien
M0111397100 von
M0111397100M0111397100
M0111397100IOSR Journals
747 views4 Folien
L011138596 von
L011138596L011138596
L011138596IOSR Journals
732 views12 Folien
K011138084 von
K011138084K011138084
K011138084IOSR Journals
602 views5 Folien
J011137479 von
J011137479J011137479
J011137479IOSR Journals
603 views6 Folien
I011136673 von
I011136673I011136673
I011136673IOSR Journals
511 views8 Folien

Último

Machine Element II Course outline.pdf von
Machine Element II Course outline.pdfMachine Element II Course outline.pdf
Machine Element II Course outline.pdfodatadese1
8 views2 Folien
START Newsletter 3 von
START Newsletter 3START Newsletter 3
START Newsletter 3Start Project
5 views25 Folien
SPICE PARK DEC2023 (6,625 SPICE Models) von
SPICE PARK DEC2023 (6,625 SPICE Models) SPICE PARK DEC2023 (6,625 SPICE Models)
SPICE PARK DEC2023 (6,625 SPICE Models) Tsuyoshi Horigome
17 views218 Folien
Effect of deep chemical mixing columns on properties of surrounding soft clay... von
Effect of deep chemical mixing columns on properties of surrounding soft clay...Effect of deep chemical mixing columns on properties of surrounding soft clay...
Effect of deep chemical mixing columns on properties of surrounding soft clay...AltinKaradagli
6 views10 Folien
Advances in micro milling: From tool fabrication to process outcomes von
Advances in micro milling: From tool fabrication to process outcomesAdvances in micro milling: From tool fabrication to process outcomes
Advances in micro milling: From tool fabrication to process outcomesShivendra Nandan
5 views18 Folien
Thermal aware task assignment for multicore processors using genetic algorithm von
Thermal aware task assignment for multicore processors using genetic algorithm Thermal aware task assignment for multicore processors using genetic algorithm
Thermal aware task assignment for multicore processors using genetic algorithm IJECEIAES
31 views12 Folien

Último(20)

Machine Element II Course outline.pdf von odatadese1
Machine Element II Course outline.pdfMachine Element II Course outline.pdf
Machine Element II Course outline.pdf
odatadese18 views
Effect of deep chemical mixing columns on properties of surrounding soft clay... von AltinKaradagli
Effect of deep chemical mixing columns on properties of surrounding soft clay...Effect of deep chemical mixing columns on properties of surrounding soft clay...
Effect of deep chemical mixing columns on properties of surrounding soft clay...
AltinKaradagli6 views
Advances in micro milling: From tool fabrication to process outcomes von Shivendra Nandan
Advances in micro milling: From tool fabrication to process outcomesAdvances in micro milling: From tool fabrication to process outcomes
Advances in micro milling: From tool fabrication to process outcomes
Thermal aware task assignment for multicore processors using genetic algorithm von IJECEIAES
Thermal aware task assignment for multicore processors using genetic algorithm Thermal aware task assignment for multicore processors using genetic algorithm
Thermal aware task assignment for multicore processors using genetic algorithm
IJECEIAES31 views
Generative AI Models & Their Applications von SN
Generative AI Models & Their ApplicationsGenerative AI Models & Their Applications
Generative AI Models & Their Applications
SN6 views
A multi-microcontroller-based hardware for deploying Tiny machine learning mo... von IJECEIAES
A multi-microcontroller-based hardware for deploying Tiny machine learning mo...A multi-microcontroller-based hardware for deploying Tiny machine learning mo...
A multi-microcontroller-based hardware for deploying Tiny machine learning mo...
IJECEIAES13 views
DevOps to DevSecOps: Enhancing Software Security Throughout The Development L... von Anowar Hossain
DevOps to DevSecOps: Enhancing Software Security Throughout The Development L...DevOps to DevSecOps: Enhancing Software Security Throughout The Development L...
DevOps to DevSecOps: Enhancing Software Security Throughout The Development L...
Anowar Hossain12 views
NEW SUPPLIERS SUPPLIES (copie).pdf von georgesradjou
NEW SUPPLIERS SUPPLIES (copie).pdfNEW SUPPLIERS SUPPLIES (copie).pdf
NEW SUPPLIERS SUPPLIES (copie).pdf
georgesradjou15 views
Literature review and Case study on Commercial Complex in Nepal, Durbar mall,... von AakashShakya12
Literature review and Case study on Commercial Complex in Nepal, Durbar mall,...Literature review and Case study on Commercial Complex in Nepal, Durbar mall,...
Literature review and Case study on Commercial Complex in Nepal, Durbar mall,...
AakashShakya1266 views
fakenews_DBDA_Mar23.pptx von deepmitra8
fakenews_DBDA_Mar23.pptxfakenews_DBDA_Mar23.pptx
fakenews_DBDA_Mar23.pptx
deepmitra814 views
Design of machine elements-UNIT 3.pptx von gopinathcreddy
Design of machine elements-UNIT 3.pptxDesign of machine elements-UNIT 3.pptx
Design of machine elements-UNIT 3.pptx
gopinathcreddy32 views
An approach of ontology and knowledge base for railway maintenance von IJECEIAES
An approach of ontology and knowledge base for railway maintenanceAn approach of ontology and knowledge base for railway maintenance
An approach of ontology and knowledge base for railway maintenance
IJECEIAES12 views

Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for Grid application

  • 1. IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331, Volume 8, Issue 4 (Nov. - Dec. 2013), PP 43-53 www.iosrjournals.org www.iosrjournals.org 43 | Page Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for Grid application Lunavath Hemsingh1 1 (Power Electronics & Automation, Neyveli Lignite Corporation Ltd, Tamilnadu, India) Abstract : This paper presents a simple step-by-step procedure for the simulation of photovoltaic modules with Matlab/ Simulink as well as Grid connected system for considering Three phase multistring inverter with sinusoidal pulse width modulation control scheme. The single -diode equivalent circuit is employed in order to Investigate I-V and P-V characteristics of a solar module. This paper focuses on a Matlab/SIMULINK model of a photovoltaic cell and Grid connected system, considering three phase multistring inverter with SPWM control scheme to reduce harmonics in primary side and same was applied to grid with prediction of PV cell behaviour under different physical and environmental parameters. The PV model is based on mathematical equations and is described through an equivalent circuit including a photocurrent source, a diode, a series resistor and a shunt resistor. The developed model can also be used to extract the physical parameters for a given solar PV cell as a function of temperature and solar radiation. Three PV strings are cascaded together in parallel configuration and connected to a five-level inverter to produce output voltage in five levels of Vdc. That was equivalent to the amplitude of the triangular carrier signal were used to generate PWM signals for the switches. The inverter offers much less total harmonic distortion and can operate at near-unity power factor. Keywords: DC-DC Converter, Multilevel Inverter, PV Module, SPWM, proportional–integral (PI) current control, multistring. I. Introduction Solar energy in one form or another is the source of nearly all energy on the earth. Humans, like all other animals and plants, rely on the sun for warmth and food. However, people also harness the sun's energy in many other different ways. For example, fossil fuels, plant matter from a past geological age, is used for transportation and electricity generation and is essentially just stored solar energy from millions of years ago. Similarly, biomass converts the sun's energy into a fuel, which can then be used for heat, transport or electricity. Wind energy, used for hundred of years to provide mechanical energy or for transportation, uses air currents that are created by solar heated air and the rotation of the earth. Even hydroelectricity is derived from the sun. Hydropower depends on the evaporation of water by the sun, and its subsequent return to the Earth as rain to provide water in dams. Photovoltaic (often abbreviated as PV) are a simple and elegant method of harnessing the sun's energy. PV devices (solar cells) are unique in that they directly convert the incident solar radiation into electricity, with no noise, pollution or moving parts, making them robust, reliable and long lasting. Solar cells are based on the same principles and materials behind the communications and computer revolutions, and this CDROM covers the operation, use and applications of photovoltaic devices and systems. Fig1.Basic solar energy conversion system A solar cell is an electronic device which directly converts sunlight into electricity. Light shining on the solar cell produces both a current and a voltage to generate electric power. This process requires firstly, a material in which the absorption of light raises an electron to a higher energy state, and secondly, the movement of this higher energy electron from the solar cell into an external circuit. The electron then dissipates its energy in the external circuit and returns to the solar cell. A variety of materials and processes can potentially satisfy the requirements for photovoltaic energy conversion, but in practice nearly all photovoltaic energy conversion uses semiconductor materials in the form of a p-n junction.
  • 2. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 44 | Page Mathematical modelling of PV module is being continuously updated to enable researcher to have a better understanding of its working [1-6].In this paper, a step-by-step procedure for simulating PV module with simple subsystem blocks, with user-friendly icons and dialog in the same way as Matlab/ Simulink block libraries is developed. The step-by-step modelling procedure of PV module as well as DC/DC converter, PWM inverter through connected to Grid is presented with simulation results for different conditions of irradiation. Photovoltaic systems require interfacing power converters between the PV arrays and the grid. These power converters are used for two major tasks. First, to ensure that the PV arrays are operated at the maximum power point (MPPT) [2-7]. Second, to inject a sinusoidal current into the grid. Normally there are two power converters [8]. The first one is a DC/DC power converter. that is used to operate the PV arrays at the maximum power point. The other one is a DC/AC power converter to interconnect the photovoltaic system to the grid. The classical single or three-phase two level voltage source inverter is normally used for this power converter type [9-12]. However, other topologies have been proposed. Multilevel converter topologies are a very interesting choice for realizing this objective. There are several PV system configurations. These configurations are the centralized technology, string technology, multi-string technology and AC-module technology. The number and type of power converters that is used to interconnect the PV system to the grid is dependent of the technology that is used. The multi-string technology has several different groups of PV arrays. Each group is connected in series with a DC/DC converter. This allows using this technology with some multilevel topologies, such as, the cascaded multicell inverters. This topology is based on the series connection of single-phase inverters with separated DC sources. In this way, each group of PV arrays will be used as a single DC source. This allows avoiding high voltage amplification. In order to obtain a galvanic connection between the grid and the PV generator many PV systems use a power transformer, avoiding that a leakage current may flow through the capacitance between PV generator and ground. Some systems use a transformer embedded in a high-frequency DC/DC converter. Others use a line frequency transformer at the output of the inverter. Fig.2 PV modules connected to grid via Multilevel inverter This mechanism proposes a three -phase multistring five-level inverter topology. It consists of three strings of PV arrays connected to their own dc–dc boost converter. An auxiliary circuit comprising four diodes and a switch is configured together with a conventional full-bridge inverter to form this topology. A SPWM control scheme is introduced to generate switching signals for the switches and to produce five output-voltage levels: zero, +1/2Vdc, Vdc, -1/2Vdc, and -Vdc (assuming that Vdc is the supply voltage). This inverter topology uses two reference signals instead of one to generate PWM signals for the switches. Both reference signals Vref1 and Vref2 are identical to each other, except for an offset value that is equivalent to the amplitude of carrier signal Vcarrier. Because the inverter is used in a PV system, a proportional–integral (PI) current control scheme is employed to keep the output current sinusoidal and to have high dynamic performance under rapidly changing atmospheric conditions and to maintain the power factor at near unity. Simulation and experimental results are presented to validate the proposed inverter configuration. II. Mathematical Model For Pv Module A solar cell is basically a p-n junction fabricated in a thin wafer of semiconductor. The electromagnetic radiation of solar energy can be directly converted to electricity through Photovoltaic effect. Being exposed to the sunlight, photons with energy greater then the band-gap energy of the semiconductor creates some electron- hole pairs proportional to the incident irradiation. Fig.3: Equivalent diagram of PV cell
  • 3. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 45 | Page A model of PV module with moderate complexity that includes the temperature independence of the photocurrent source, the saturation current of the diode, and a series Resistance is considered based on the Shockley diode equation. The current source Iph represents the cell photocurrent. Rsh and Rs are the intrinsic shunt and series resistances of the cell, respectively. Usually the value of Rsh is very large and that of Rs is very small, hence they may be neglected to simplify the analysis. PV cells are grouped in larger units called PV modules which are further interconnected in a parallel-series configuration to form PV arrays. The photovoltaic panel can be modelled mathematically as given in equations (1)- (4) [3] – [5]. Module photo- current: 𝐼𝑝𝑕 = 𝐼𝑆 𝐶𝑟 + 𝐾𝑖 𝑇 − 298 ∗ 𝜆 1000 (𝑖) Modules reverse saturation current - Irs: 𝐼𝑟𝑠 = 𝐼𝑆𝐶𝑟 /[exp 𝑞𝑉𝑂𝐶 𝑁𝑠 𝑘𝐴𝑇 − 1] (𝑖𝑖) The module saturation current I0 varies with the cell temperature, which is given by 𝐼 𝑂 = 𝐼𝑟𝑠 𝑇 𝑇𝑟 ∗ [exp 𝑞 ∗ 𝑉𝑔𝑜 𝐵𝑘 1 𝑇𝑟 − 1 𝑇 − 1] (𝑖𝑖𝑖) The current output of PV module is 𝐼 𝑃𝑉 = 𝑁𝑃 ∗ 𝐼𝑝𝑕 − 𝑁𝑃 ∗ 𝐼𝑜 [exp 𝑞 ∗ (𝑉𝑃𝑉 + 𝐼 𝑃𝑉 𝑅𝑆 𝑁𝑆 𝐴𝑘𝑇 − 1] (𝑖𝑣) Where Vpv = Voc, Np = 1 and Ns = 36 PV module represents the fundamental power conversion unit of a PV generator system. The output characteristics of a PV module depend on the solar insolation, the cell temperature and the output voltage of the PV module. Since PV module has nonlinear characteristics, it is necessary to model it for the design and simulation of maximum power point tracking (MPPT) for PV system applications. The above mentioned equations are modelled by using common Simulink blocks as shown below fig:3 a. Subsystem 1 is shown in Figure 4. This model converts the module operating temperature given in degrees Celsius to Kelvin. b. subsystem 2 This model calculates the short circuit current ( ISC) at given operating temperature. Figure 4 gives the circuit under subsystem. c. Subsystem 3 is shown in Figure 4. This model takes short circuit current ISC at reference temp. = 2.55A and Module reference temperature TrK = 25oC as input. d. Subsystem 4 This model takes reverse saturation current Irs, Module reference temperature TrK = 250 C and Module operating temperature TaK as input and calculates module saturation current. e. This model takes operating temperature in Kelvin TaK and calculates the product NsAkT, the denominator of the exponential function in equation (4). f. This model executes the function given by the equation (4). The following function equation is used. This gives the circuit under subsystem 6. IPV = u(3)-u(4)*(exp((u(2)*(u(1)+u(6)))/(u(5)))-1) All the above six subsystem models are interconnected in such a way that to produce PV current at corresponding voltage. Fig.4 Interconnected Simulink model for all equations sub systems
  • 4. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 46 | Page The final model takes irradiation; operating temperature in Celsius and module voltage as input and gives the output current Ipv and output voltage Vpv and Rated Power Ppv.The workspace is added to measure Ipv, Vpv, and Ppv in this model. III. Modelling Of Multistring Five-Level Inverter Topology The proposed Three-phase multistring five-level inverter topology is shown in Fig. 5. It consists of three dc–dc boost converters connected to a common dc bus, an auxiliary circuit, and a full-bridge inverter configuration. Input sources, PV string 1, PV string 2, and PV string 3 are connected to the inverter via the dc– dc boost converters. Because the proposed inverter is used in a grid-connected PV system, the utility grid is used instead of a load. The dc–dc boost converters are used to track the maximum power point (MPP) independently and to step up inverter output voltage Vinv to be more than √2 of grid voltage Vg to ensure power flow from the PV arrays into the grid [12]. 𝑉𝑖𝑛 > 2 𝑉𝑔 2𝑉 𝑖𝑛 (v) The dc–dc boost converters are connected in parallel to avoid high dc-bus voltage, which will eventually increase the size of the capacitors and the inverter’s cost. Therefore, only two capacitors with equal capacitance rating are used as the dc bus, and the other dc–dc boost converters are connected to this dc bus, as shown in Fig. 5. Fig.5: Proposed approach of multilevel inverter Fig.6: Equivalent model of Pv module connected to grid A filtering inductance Lf is used to filter the current injected into the grid. The injected current must be sinusoidal with low harmonic distortion. In order to generate sinusoidal current, a sinusoidal PWM is used because it is one of the most effective methods. A sinusoidal PWM is obtained by comparing a high frequency carrier signal with a low-frequency sinusoid signal, which is the modulating or reference signal. The carrier has PV MODULE DC/DC CONVERTER LOAD/GRID PWM GENERATOR PI CONTROLLER
  • 5. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 47 | Page a constant period; therefore, the switches have constant switching frequency. The switching instant is determined from the crossing of the carrier and the modulating signal. Modulation index Ma for a five-level PWM inverter is given as [13-14] 𝑀𝑎 = 𝐴 𝑚 2𝐴 𝑐 (vii) where Ac is the peak-to-peak value of carrier and Am is the peak value of voltage reference Vref . Because, in this paper, two reference signals that are identical to each other are used, (vii) can be expressed in terms of the amplitude of carrier signal Vc by replacing Ac with Vc, and Am = Vref1 = Vref2 = Vref . 𝑀 = 𝑉𝑟𝑒𝑓 2𝑣𝑐 (𝑣𝑖𝑖𝑖) From the PWM modulation, the analysis of harmonic components in the proposed inverter can be preformed. The output voltage produced by comparison of the two reference signals and the carrier signal can be expressed as [7] 𝑉0 𝜃 = 𝐴0 + (𝐴 𝑛 𝑐𝑜𝑠𝑛𝜃 + 𝐵𝑛 𝑠𝑖𝑛𝑛𝜃) ∞ 𝑛=1 (𝑖𝑥) If there are P pulses per quarter period, and it is an odd number, coefficients Bn and Ao would be zero, where n is an even number. Therefore, the (ix) can be rewritten as 𝑉0 𝜃 = 𝐴 𝑛 𝑐𝑜𝑠𝑛𝜃 ∞ 𝑛=1 (𝑥) 𝐴 𝑛 = − 2𝑉 𝑑𝑐 𝑛𝜋 [(−1)𝑖𝑛𝑡 ( 𝑖 2 )4 𝑖=1 𝑃 𝑚=0 sin⁡(𝑛𝛼 𝑚+𝑖)] (𝑥𝑖) Fig.7: carrier and reference signal for modulation index M=0.5 where m is a pulse number and α is the phase displacement angle. The Fourier series coefficients of the conventional single phase full-bridge inverter by sinusoidal PWM is given as 𝐴 𝑛 = − 𝑉𝑑𝑐 𝑛𝜋 [ −1 𝑚 𝑝 𝑚=1 sin⁡(𝑛𝛼 𝑚 )] (𝑥𝑖𝑖) Combinations of PV strings are used as the input voltage sources. The voltage across the strings are known as Vpv1, Vvp2, and Vpv3. Referring to (1) and (2), Vpv1, Vvp2, and Vvp3 are boosted by the dc–dc boost converters to exceed grid voltage Vg, and the voltage across the dc bus is known as Vpv. The operating principle of the proposed inverter is to generate five output-voltage levels, i.e., 0, +Vpv/2, +Vpv, −Vpv/2, −Vpv, as in Fig. 8. As shown in Fig. 5, an auxiliary circuit that consists of four diodes and a switch S4 is used between the dc- bus capacitors and the full-bridge inverter. Proper switching control of the auxiliary circuit can generate half level of PV supply voltage, i.e., +Vpv/2 and -Vpv/2 [15-17].
  • 6. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 48 | Page Fig. 8. Inverter output voltage (Vinv) and switching pattern for the five-level inverter Two reference signals Vref1 and Vref2 will take turns to be compared with the carrier signal at a time. If Vref1 exceeds the peak amplitude of carrier signal Vcarrier, then Vref2 will be compared with the carrier signal until it reaches zero. At this point onward, Vref1 takes over the comparison process until it exceeds Vcarrier. This will lead to a switching pattern, as shown in Fig. 8. Switches S4–S6 will be switching at the rate of the carrier signal frequency, while S7 and S8 will operate at a frequency that is equivalent to the fundamental frequency. Table I illustrates the level of Vinv during S4–S8 switch on and off. If one of the PV strings is disconnected from the dc bus, the operation of the other dc–dc boost converters will not be affected because they are connected in parallel. As the dc–dc boost converters are used to track the MPPT point, it can be concluded that the MPPT of the PV strings is done independently. Later expansion of the PV strings is also possible by adding a dc–dc boost converter, as shown in Fig. 5. TABLE I Inverter Output Voltage during S4–S8 switch ON and OFF S4 S5 S6 S7 S8 Vinv 1 0 0 0 1 +Vpv2 0 1 0 0 1 +Vpv 0 1 0 0 1 1 0 0 1 0 1 0 0 1 0 -Vpv2 0 0 1 1 0 -Vpv IV. Simulation Results And Discussion (a) PV Module Fig.9: Simulink model of PV module with workspace
  • 7. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 49 | Page With the developed model, the PV module characteristic is estimated as follows. (1) I-V and P-V characteristics under varying irradiation with constant temperature are obtained as shown in Figures 9(a) to 9(d). Between 0 and 1 s, the irradiation is 200W/m2, between 1 and 2 s it is 600 W/m, while from 2 s onwards it is 1000W/m2. 2. In Figure 9(b), the input temperature is shown which is constant at25 𝑂𝐶. Fig.9 (a) Insolation at different levels Fig.9 (b) Constant temperature input 3. The I-V and P-V output characteristics of PV module with varying irradiation at constant temperature are shown in Figure 9(c) and 9(d). Fig 9(c). Output – I-V characteristics with varying irradiation Fig 9(d). Output – P-V characteristics with varying irradiation From the above plots we can conclude that, when the irradiation increases, A. The current output increases B.The voltage output also increases. This results in net increase in power output with increase in irradiation at constant temperature. II. I-V and P-V Characteristics under constant irradiation with varying temperature are obtained in Figures 10(a) to 10(d). 1. In Figure 10(a) the time varying temperature signal is shown. Between 0 and 1 second, the temperature of 25 C is applied and it is increased to 50 and 750C. Fig 5(a). Input – Time varying temperature 0 1 2 3 4 5 6 7 8 9 10 0 0.2 0.4 0.6 0.8 1 1.2 1.4 INSOLATION Time (sec) untitled/Signal Builder : Group 1 0 1 2 3 4 5 6 7 8 9 10 24 24.2 24.4 24.6 24.8 25 25.2 25.4 25.6 25.8 26 Temperature Time (sec) untitled/Signal Builder : Group 1 0 5 10 15 20 25 0 0.5 1 1.5 2 2.5 3 PV Voltage(Vpv) PVCurrent(Ipv) V-I CHARACTERISTICS OF PV MODEL 1000W/m2 600W/m2 200W/m2 0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 45 PV Voltage(Vpv) PVPower(Ppv) P-V CHARACTERISTICS OF PV MODEL 1000 W/m2 600 W/m2 200 W/m2 0 1 2 3 4 5 6 7 8 0 10 20 30 40 50 60 70 80 TEMPERATURE Time (sec) untitled/Signal Builder : Group 1
  • 8. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 50 | Page 2. The I-V output characteristics of PV module with varying temperature at constant irradiation of 1000W/m2 are shown in Figure 10(b). Figure 10(b). Output – I-V characteristics with varying temperature 3. The P-V output characteristics of PV module with varying temperature at constant irradiation are shown in Figure 10(c). Figure 10(c). Output – P-V characteristics with varying temperature From above Case-ii we can conclude that, when the operating temperature increases, A. The current output increases marginally, but the voltage output decreases drastically B.Results in net reduction in power output with rise in temperature The results are verified and found matching with the manufacturer’s data sheet output curves. (b) GRID Connected system Simulations were performed by using MATLAB/Simulink to verify that the proposed inverter can practically be implemented in a PV system. It helps one to confirm the PWM switching strategy for the multistring five-level inverter. Then, this strategy is implemented in a real-time environment, i.e., the DSP to produce PWM switching signals for the switches. Fig. 10(a) shows the way the PWM switching signals are generated by using two reference signals and a triangular carrier signal. The resulting PWM signals for switches S4–S8 are shown in Fig. 10(b)–(f). Note that one leg of the inverter is operating at a high switching rate that is equivalent to the frequency of the carrier signal, while the other leg is operating at the rate of fundamental frequency (i.e., 50 Hz). The switch at the auxiliary circuit (S4) also operates at the rate of the carrier signal. As mentioned earlier, modulation index M will determine the shape of inverter output voltage Vinv and grid current Ig. Fig. 11 shows the simulation results of Vinv and Ig for different values of M. The dc-bus voltage is set to 200 V. Below figures shows that the power generated from Photo voltaic modules are collected as a DC source of low voltage ,thus generated voltage was step up by using DC-DC converters as a 200V .The voltage produced by converter is not AC source, to convert DC to Alternating current we used here a Inverter consisting of Sinusoidal Pulse width Modulation. The Harmonics generated by the source is very less and power factor is almost near by unity. 0 2 4 6 8 10 12 14 16 18 1.6 1.8 2 2.2 2.4 2.6 PV Voltage(Vpv) PVCurrent(Ipv) V-I CHARACTERISTICS OF PV MODEL CONSTANT INSOLATION 1000W/m2 Tref 25 oC Tref 50 oC Tref 75 oC 0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 45 PV Voltage(Vpv) PVPower(Ppv) P-V CHARACTERISTICS AT CONSTANT INSOLATION 1000 W/m2 Tref 25 oC Tref 50 oC Tref 75 oC
  • 9. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 51 | Page Fig.11: Multilevel inverter for three phase system Fig.12: Simulink block with PV and control strategy of Grid system Fig.12(a).Reference and carrier signal generation Fig.12 (b).Inverter output voltage i.e. grid connected voltage 0 0.005 0.01 0.015 0.02 0.025 -20 -10 0 10 20 30 40 Amplitude Time(S) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 -200 -150 -100 -50 0 50 100 150 200 Time(s) PhaseVoltage(V) INVERTER OUTPUT VOLTAGE(GRID VOLTAGE)
  • 10. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 52 | Page Fig.12(c).Inverter output current i.e. grid current Fig.12(d).FFT analysis of grid connected system_R_ Phase VII. Conclusion This paper has presented the step-by-step procedure for modelling the PV module is presented with three-phase multistring five-level inverter for PV application. This mathematical modelling procedure serves as an aid to induce more people into photovoltaic research and gain a closer understanding of I-V and P-V characteristics of PV module. A novel PWM control scheme with two reference signals and a carrier signal has been used to generate the PWM switching signals. The circuit topology, control algorithm, and operating principle of the proposed inverter have been analysed in detail. The configuration is suitable for PV application as the PV strings operate independently and later expansion is possible. Furthermore, the experimental results indicate that the THD of the multistring five-level inverter is much less than that of the conventional multistring three-level inverter. In addition, both grid voltage and grid current are in phase at near-unity power factor. References Proceedings Papers: [1 ] M.Veerachary, “Power Tracking for Nonlinear PV Sources with Coupled Inductor SEPIC Converter,” IEEE Transactions on Aerospace and Electronic Systems, vol. 41, No. 3, July 2005. [2] I. H. Altas and A.M. Sharaf, “A Photovoltaic Array Simulation Model for Matlab-Simulink GUI Environment,” IEEE, Clean Electrical Power, International Conference on Clean Electrical Power (ICCEP '07), June 14-16, 2007, Ischia, Italy. [3] S.Chowdhury, S.P.Chowdhury, G.A.Taylor, and Y.H.Song, “Mathematical Modelling and Performance Evaluation of a Stand- Alone Polycrystalline PV Plant with MPPT Facility,” IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, July 20-24, 2008, Pittsburg, USA. [4] Jee-Hoon Jung, and S. Ahmed, “Model Construction of Single Crystalline Photovoltaic Panels for Real-time Simulation,” IEEE Energy Conversion Congress & Expo, September 12-16, 2010, Atlanta, USA. [5] S. Nema, R.K.Nema, and G.Agnihotri, “Matlab / Simulink based study of photovoltaic cells / modules / array and their experimental verification,” International Journal of Energy and Environment, pp.487- 500, Volume 1, Issue 3, 2010. [6] N. A. Rahim and S. Mekhilef, “Implementation of three-phase grid connected inverter for photovoltaic solar power generation system,” in Proc. IEEE PowerCon, Oct. 2002, vol. 1, pp. 570–573. 0.02 0.03 0.04 0.05 0.06 0.07 0.08 -10 -5 0 5 10 Time(s) Gridcurrent(A) GRID CURRENT
  • 11. Mathematical Modelling of PV Module With multilevel 3-Ø inverter using SPWM technique for grid application www.iosrjournals.org 53 | Page Journal Papers: [7] Aryuanto Soetedjo*, Abraham Lomi, Yusuf Ismail Nakhoda, Awan Uji Krismanto, “Modelling of Maximum Power Point Tracking Controller for Solar Power System: TELKOMNIKA, , pp. 419~430 e-ISSN: 2087-278X.,Vol.10, No.3, July 2012. [8] V. Fernão Pires*, J. F. Martins**, D. Foito*, Chen Hão , “ A Grid Connected Photovoltaic System with a Multilevel Inverter and a Le-Blanc Transformer,” INTERNATIONAL JOURNAL of RENEWABLE ENERGY RESEARCH Vitor Fernão Pires et al., Vol.2, No.1, 2012. [9] Alias Khamis, Mohamed,H. Shareef,A. Ayob” Modelling and simulation of a micro grid tested using photovoltaic and battery based power generation” Journal of Asian Scientific Research 2(11):658-666 [10] Tarak Salmi*, Mounir Bouzguenda**, Adel Gastli**, Ahmed Masmoudi* “MATLAB/Simulink Based Modelling of Solar Photovoltaic Cell,” INTERNATIONAL JOURNAL of RENEWABLE ENERGY RESEARCH Tarak Salmi et al., Vol.2, No.2, 2012. [11] M. Meinhardt and G. Cramer, “Past, present and future of grid-connected photovoltaic- and hybrid-power-systems,” in Proc. IEEE- PES Summer Meeting, Jul. 2000, vol. 2, pp. 1283–1288. Proceedings Papers: [12] S. Kouro, J. Rebolledo, and J. Rodriguez, “Reduced switching-frequency modulation algorithm for high-power multilevel inverters,” IEEE Trans. Ind. Electron., vol. 54, no. 5, pp. 2894–2901, Oct. 2007. [13] S. J. Park, F. S. Kang, M. H. Lee, and C. U. Kim, “A new single-phase five level PWM inverter employing a deadbeat control scheme,” IEEE Trans. Power Electron., vol. 18, no. 18, pp. 831–843, May 2003. [14] L. M. Tolbert and T. G. Habetler, “Novel multilevel inverter carrier-based PWM method,” IEEE Trans. Ind. Appl., vol. 35, no. 5, pp. 1098–1107, Sep./Oct. 1999. [15] Y. Liu, H. Hong, and A. Q. Huang, “Real-time calculation of switching angles minimizing THD for multilevel inverters with step modulation,” IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 285–293, Feb. 2009. [16] N. S. Choi, J. G. Cho, and G. H. Cho, “A general circuit topology of multilevel inverter,” in Proc. IEEE 22th Annu. PESC, Jun. 24– 27, 1991, pp. 96–103. [17] G. Carrara, S. Gardella, M. Marchesoni, R. Salutari, and G. Sciutto, “A new multilevel PWM method: A theoretical analysis,” IEEE Trans. Power Electron., vol. 7, no. 3, pp. 497–505, Jul. 1992. IX. NOMENCLATURE Vpv is output voltage of a PV module (V) Ipv is output current of a PV module (A) Tr is the reference temperature = 298 K T is the module operating temperature in Kelvin Iph is the light generated current in a PV module (A) Io is the PV module saturation current (A) A = B is an ideality factor = 1.6 k is Boltz man constant = 1.3805 × 10-23 J/K q is Electron charge = 1.6 × 10-19 C Rs is the series resistance of a PV module ISCr is the PV module short-circuit current at 25 oC at 1000W/m2 = 2.55A Ki is the short-circuit current temperature co-efficient at ISCr = 0.0017A / oC 𝜆 is the PV module illumination (W/m2) = 1000W/m2 Ego is the band gap for silicon = 1.1 eV Ns is the number of cells connected in series Ma is Modulation index Vout Inverter output voltage Vg is Grid voltage,Ig is Grid current Np is the number of cells connected in parallel. Lunavath. Hemsingh was born in Andhra Pradesh, India, in 1988. He received the B.Tech (EEE) degree from Jawaharlal Nehru Technological University, Hyderabad, India, in 2010, The M.Tech. Degree in power and Energy systems from the National Institute of Technology Karnataka, Surathkal, India in 2012 He is currently Working as a Asst.Execuitive Engineer (Electrical) ,Power Electronics & Automation division in Neyveli Lignite Corporation Ltd ,Tamilnadu,India. His research interests are Power electronics and Automation of multilevel inverters, PI current control techniques, photovoltaic inverters, and dc–dc converters.