IO Interface (1).pptx

  1. EN 8086 MPU DATA RD DEN DT/R ALE BHE/S7 M/IO AD0-AD15, A16/S3- A19/S6 WR DIR EN G EN ADDRESS DECODER 8KX8 8KX8 MEMORY CS CS ADDRESS OE WR 74LS245 74LS244 74LS373 74LS138
  2. 4 BHE*
  3. R 1 0
  4. 8086 Minimum Mode A18 A0 : D7 D6 A19 D5 D4 D3 D2 D1 D0 directly
  5. : mov al, 55 mov dx, 0F000h out dx, al : 74LS245 B0 B1 B2 B3 B4 B5 B6 B7 A0 A1 A2 A3 A4 A5 A6 A7 E DIR 5V 543210 A 1 A 1 A 1 A 1 A 1 A 1 A 9 A 8 A 7 A 6 A 5 A 4 A 3 A 2 A 1 A 0 IOW via bidirectional 8086 Minimum Mode A18 A0 : D7 D6 A19 D5 D4 D3 D2 D1 D0 What is the problem ?
  6. : mov al, 55 mov dx, 0F000h out dx, al : 74LS373 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 D0 D1 D2 D3 D4 D5 D6 D7 G EN 0V 543210 A 1 A 1 A 1 A 1 A 1 A 1 A 9 A 8 A 7 A 6 A 5 A 4 A 3 A 2 A 1 A 0 IOW 8086 Minimum Mode A18 A0 : D7 D6 A19 D5 D4 D3 D2 D1 D0
  7. 8086 74LS373 Data bus 74LS138 Address bus
  8. a b c g d e f Digit -abcdefg- hex Digit -abcdefg- hex 0 -1111110- 7Eh 1 -0110000- 30h 2 -1101101- 6Dh 3 -1111001- 79h 4 -0110011- 33h 5 -1011011- 5Bh 6 -1011111- 5Fh 7 -1110000- 70h 8 -1111111- 7Fh 9 -1111011- 7Bh A -1110111- 77h B -0011111- 1Fh C -1001110- 4Eh D -0111101- 3Dh E -1001111- 4Fh F -1000111- 47h
  9. R VCC S1 A R VCC S1 A Toggle Switch Push button Switch
  10. : mov al, 55 mov dx, 0F000h in al, dx : 74LS245 B0 B1 B2 B3 B4 B5 B6 B7 A0 A1 A2 A3 A4 A5 A6 A7 E DIR 0V 543210 A 1 A 1 A 1 A 1 A 1 A 1 A 9 A 8 A 7 A 6 A 5 A 4 A 3 A 2 A 1 A 0 IOR 8086 Minimum Mode A18 A0 : D7 D6 A19 D5 D4 D3 D2 D1 D0 Be careful to the DIR control 5V
  11. T1 T2 T3 T4 T1 T2 T3 Tw T4 Bus Cycle Bus Cycle One Wait State CLK (RD is kept high) Mem Write I/O Output Status Status A(19-16) BHE AD(15-0) Data Out A A Data Out Latch Address Latch Address ALE Mem I/O M / IO Write Write WR Latch Data Latch Data Transmit Transmit DT/R Disable Enable Disable Enable DEN Ready Ready Wait READY Valid Valid AB(19-0) Data Out Data Out DB(15-0) A,BHE A,BHE
  12. T1 T2 T3 T4 T1 T2 T3 Tw Tw T4 Bus Cycle Bus Cycle Two Wait States States CLK Status Status A(19-16) BHE A,BHE A,BHE (WR is kept high) Mem Read I/O Input A Data In A Data In AD(15-0) Latch Address Latch Address ALE Mem I/O M / IO Read Read RD Receive Receive DT/R Disable Enable Disable Enable DEN Ready Ready Wait Wait READY Valid Valid AB(19-0) Data In Data In DB(15-0)
  13. 74LS373 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 G EN 74LS373 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 G EN 5 4 3 2 1 0 A 1 A 1 A 1 A 1 A 1 A 1 A9 A 8 A 7 A 6 A 5 A 4 A 3 A 2 A 1 5V 74LS245 B0 B1 B2 B3 B4 B5 B6 B7 A0 A1 A2 A3 A4 A5 A6 A7 E DIR 5V 74LS245 B0 B1 B2 B3 B4 B5 B6 B7 A0 A1 A2 A3 A4 A5 A6 A7 E DIR M/ IO WR RD BAD0-BAD15 SD8-SD15 DD8-DD15 DD0-DD7 SD0-SD7 8086 CPU 74LS245 SLD0 SLD1 SLS0 SLS1 IORD IOWR A0 BHE
  14. M/IO RD WR BHE A0 A15 –A3 A2 A1 SLD1 SLD0 SLS1 SLS0 1 X X X X X X X 1 1 1 1 0 0 1 0 0 0 1 0 1 1 0 0 0 0 1 1 0 0 1 0 1 1 1 0 0 0 1 0 1 0 1 0 1 1 0 1 0 1 0 0 0 0 1 0 0 0 1 1 0 1 0 1 0 0 1 0 1 0 1 1 0 1 0 0 1 0 1 0 0 1 1 1 X X X X X X 0 X 1 1 1 1 TRUTH TABLE
  15. 1. Draw the complete block diagram for an 8086 Microprocessor system with 8-push button switches and 8-LEDs in detail assigning the switches address at (44h) and the LEDs address at (44h) also . 3. Redraw the same block diagram if you have 32-switches and 32 –LEDs, starting with the address (5002h) for both input and output then write a program to read the switch states and output them to the LEDs in accordance.
  16. Required Circuits in Maximum-mode GND AD14 AD13 AD12 AD11 AD10 AD9 AD8 AD7 AD6 AD5 AD4 AD3 AD2 AD1 AD0 NMI INTR CLK GND VCC AD15 A16/S3 A17/S4 A18/S5 A19/S6 HOLD HLDA ALE READY RESET BHE/S7 MN/MX RD WR M/IO DT/R DEN INTA TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 31 30 29 28 27 26 25 24 23 22 21 40 39 38 37 36 35 34 33 32 8086 (Vcc) Min Mode GND AD14 AD13 AD12 AD11 AD10 AD9 AD8 AD7 AD6 AD5 AD4 AD3 AD2 AD1 AD0 NMI INTR CLK GND VCC AD15 A16/S3 A17/S4 A18/S5 A19/S6 RQGT0 RQT1 QS0 READY RESET BHE/S7 MN/MX RD LOCK S2 S1 S0 QS1 TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 31 30 29 28 27 26 25 24 23 22 21 40 39 38 37 36 35 34 33 32 8086 (GND) Max Mode
  17. 8288 BUS Controller
  18. IO/M DT/R SSO CHARACTERISTICS 0 0 0 Code Access 0 0 1 Read Memory 0 1 0 Write Memory 0 1 1 Passive 1 0 0 Interrupt Acknowledge 1 0 1 Read I/O port 1 1 0 Write I/O port 1 1 1 Halt Read Write Control Signals S0 S1 S0
  19. 8086 maximum mode bus interface