1. FPI 800P
Frequency Voltage kVa Kw Kva Kw
50Hz 400 800 640 900 720
60Hz 480 844 675 938 750
the above KW rating are at 0.8 pf
Guarantied within condition equivalent to those specification in ISO 8528-1,ISO 3046-1 and BS 5514-1.
* Prime power rating of the generating set is where a variable load and unlimited hours usage are applied
on the generating set with an Average load factor of 80% of the prime rating over each 24 hours period.
Note: That a 10% overload is availble for 1 hour in every 12 hours operation
** Standby power rating of the generating set is where a variable load limited to an annual usage up to 500
hours is applied, with 300 hours of which may be continous running. Note that no overload is permitted.
Engine Speed
Standby
Prime Power
75% of Prime Power
50% of Prime Power
Cooling Fan Air Flow m3/min (cfm) System designed for ambients up to 35ºC or 50ºC
Prime
Standby
Grade
Size
Qty
Prime
Standby
Prime
Standby
1800 L/1800L
Exhaust Gas Max
Temp
6 kpa
50 Hz
500 `c
500 `c
209 (7380.76)
209 (7380.76)
60 Hz
500 `c
500 `c
Silencer
Exhaust Gas Flow
m³/min (cfm)
Max Allowable Backpressure
Exhaust System
Industrial
6~
2
193 (6815.73)
193 (6815.73)
6 kpa
90 kw
Coolant Capacity
Cooling System
105 litres
86 kw
Heat Radiation to
Room
50 Hz
77kw
Twin thermostats, water pump
60 Hz
80 kw
Oil Cooling Method
113.4 litres
113.4 litres
Oil cooler with separate filter header
Wet sump with filler and dipstick
Cooling System
Lubrication oil filtersLube Oil
Lube Oil Capacity
Oil Pan
Oil FilterTtype
1800 rpm
230 (224)
226 (200)
214 (144)
205 (96)
Lubrication System
Fuel Tank Capacity: Open / Close
Fuel Filter Type
Fuel System
Class A2 Diesel
1500 rpm
212 (194)
210 (172)
210 (130)
213 (90)
Fuel Consumption
l/hr(US gal/hr)
76 (2683.91)
78 (2754.54)
Air Filter Type
Electrical Starting System
73 (2577.97)
60 Hz
Max air filter intake restriction 3.7 kpa 3.7 kpa
TA Luft (1986)
24 volt starter motor, 24 volt 70 amp battery charging alternator with integral voltage regulator and activating
switch
Combustion System
Displacement
Governor
Emissions Regulations
Direct injection
22.91 litres
1500
1800
Electronic - Digital
Paper Element (Replaceable)
50 Hz
69 (2436.71)
Aspiration
PERKINS 4006-23TAG3A
6 Vertical in-line
Turbocharged and Air-to-Air charge cooled
Engine Make And Model
Cylinders
Air System
Combustion Air Flow Cm/min(cfm)
Output Power Rating Prime Standby
Switch able speed 1500/1800 rpm
Engine Technical Data
rpm
2. 380 400 415 380 416 440 480
775 800 775 866 936 960 960
620 640 620 693 749 768 768
Xd % — 33.2 — — — — — 332
Xd % — 16.2 — — — — — 16.2
Xd % — 12.9 — — — — — 12.9
— 2048 — — — — — 2397.6
Noise Level (@ Free Field Conditions)
Weight (kg)
5393
7330
Width
(mm)
2000
2065
Height
(mm)
2450
3340
Type
open
Enclosed
Length (mm)
4520
5965
RAL 9011
Shipping Data
Water Fill
Cable Access
Emergency Stop
Canopy RAL Color
Chassis RAL Color
77dBA@7 meter
Radiator Water Filling Provision
Cable Inlet and Outlet Provision
External Emergency Push Button
RAL 2000
Transportation Tested Single Point Lifting Facility & Forklift Pockets
Drainage
60 (2118.88)
72 (2542.65)
Acoustic and Weather Proof
Polyester Powder Coated Galvanized Sheet
6
R448
±0.5%
IP-23
H
at No load <4%, on load <4%
<50
Regulation
Ingress Protection
Insulation Class
Total harmonic TGH/THC
TIF
Fuel & Water Drainage Provision
Gen-set Enclosure Specification (Optional)
Enclosure Type
Anticorrosive Protection
Access Doors
Cooling Air Flow-@50 Hzm³/min (fcm)
Cooling Air Flow-@60 Hzm³/min (fcm)
Alternator Technical Data Stamdford / or LS
Leroy Somer LSA 49.1 M75
4
6
Model Number
No. of Poles
A.V.R & Excitation
Number of Terminals (leads)
Output Voltage
V
KVA
Reactance (f.l.cl.F)
Motor Starting Capability Based
on 30% voltage dip and 0.8 PF (KVA)
Alternator Performance Data
KW
50 Hz 60 Hz
DSEController features
Engine Protections
Inputs and Outputs
3 No`s configuration analog inputs 6 No`s binary outputs
over under frequncy
4 No`s binary inputs charging alternator fault
Controller Make and Model
Generator Protections
over current
over/under frequency phases sequence
Gen-set text alarm log Engine hours history log
for more features we can use higher controler
Event and Performance Log
Auto mains failure (AMF) applications including remote communication, user configuration and
complete gen-set monitoring and protection, ready for generators with 3 ph 4 wire/3 ph 3 wire/
mono ph
oil pressure fuel level optional
coolant temprature coolant level optional
over/under voltage