1. FPI 1000P
Frequency Voltage kVa Kw Kva Kw
50Hz 400 1000 728 1100 802
60Hz 480 995.2 818 1095 900
the above KW rating are at 0.8 pf
Guarantied within condition equivalent to those specification in ISO 8528-1,ISO 3046-1 and BS 5514-1.
* Prime power rating of the generating set is where a variable load and unlimited hours usage are applied
on the generating set with an Average load factor of 80% of the prime rating over each 24 hours period.
Note: That a 10% overload is availble for 1 hour in every 12 hours operation
** Standby power rating of the generating set is where a variable load limited to an annual usage up to 500
hours is applied, with 300 hours of which may be continous running. Note that no overload is permitted.
Engine Speed
Standby
Prime Power
75% of Prime Power
50% of Prime Power
Nil/Nil
Cooling Fan Air Flow m3/min (cfm)
Prime
Standby
Grade
Size
Qty
Prime
Standby
Prime
Standby
Length (mm) Wiedth (mm) Height (mm)
4600 2222 2508
Exhaust Gas Max
Temp
8 kpa
50 Hz
438 `c
465 `c
202 (7133.5)
202 (7133.5)
60 Hz
505 `c
505 `c
Silencer
Exhaust Gas Flow
m³/min (cfm)
Max Allowable Backpressure
Exhaust System
Industrial
6"
2
200 (7062.9)
200 (7062.9)
6.69 kpa
100 kw
Coolant Capacity
Cooling System
149 L
100 kw
Heat Radiation to
Room
50 Hz
80 kw
Water Cooled
60 Hz
85 kw
Oil Cooling Method
153 L
127 L
Full-flow spin-on
Water
Cooling System
1350 (47674.8) 1290 (45555.9)
API-CG4, SAE 15W-40 (10`c to 50 `c Ambient Temperature)Lube Oil
Lube Oil Capacity
Oil Pan
Oil FilterTtype
1800 rpm
249 (65.7)
224 (59.1)
162 (42.8)
108 (28.5)
Lubrication System
Fuel Tank Capacity: Open / Close
Fuel Filter Type
Fuel System
Class A2 Diesel
1500 rpm
286 (75.6)
226 (59.7)
163 (43.1)
109 (28.8)
Fuel Consumption
l/hr(US gal/hr)
72 (2542.6)
75 (2648.6)
Air Filter Type
Electrical Starting System
80.5 (2842.8)
60 Hz
Max air filter intake restriction 3.7 kpa 3.7 kpa
TA Luft (1986)
24 volt starter motor and 24 volt/40 amp alternator with integral regulator and DC output
Combustion System
Displacement
Governor
Emissions Regulations
Direct injection
30.561 litres
1500
1800
Electronic - Digital
Paper Element (Replaceable)
50 Hz
75.0 (2648.6)
Aspiration
PERKINS 4008TAG2A / 4008TAG2
8 vertical in-line
Turbocharged and air-to-air charge cooled
Engine Make And Model
Cylinders
Air System
Combustion Air Flow m³/min(cfm)
Output Power Rating Prime Standby
Switch able speed 1500/1800 rpm
Engine Technical Data
rpm
Shipping Data
Type
Open
Enclosed
Weight (kg)
8000
1090020 feets ISO HQ Continer
2. 380 400 415 440 380 416 440 480
1040 1040 1040 1040 1085 1185 1235 1300
832 832 832 832 868 948 988 1040
Xd % ̶— 394 ̶— ̶— ̶— ̶— ̶— 410
Xd % ̶— 108 ̶— ̶— ̶— ̶— ̶— 21.5
Xd % ̶— 17.6 ̶— ̶— ̶— ̶— ̶— 18.4
̶— 2100 ̶— ̶— ̶— ̶— ̶— 2550
Noise Level (@ Free Field Conditions)
Controller features
Engine Protections
Inputs and Outputs
3 No`s configuration analog inputs 6 No`s binary outputs
4 No`s binary inputs charging alternator fault
Controller Make and Model
Generator Protections
over current
Number of Terminals (leads)
Output Voltage
V
KVA
Reactance (f.l.cl.F)
Motor Starting Capability
Based on 30% voltage dip and 0.8 PF (KVA)
Alternator Performance Data
KW
THD at No Load %
Cooling Air Flow-@50 Hzm³/min (fcm)
Cooling Air Flow-@60 Hzm³/min (fcm)
Alternator Technical Data Stamdford / or LS
Leroy Somer LSA 49.1 L11
4 Poles
6
Model Number
No. of Poles
A.V.R & Excitation
Regulation
Ingress Protection
Insulation Class
Total harmonic TGH/THC
TIF
R220
±0.5%
IP23
H
<3.5%
108 (3813.98)
132 (4661.53)
1.2 m³/s
Acoustic and Weather Proof
Polyester Powder Coated Galvanized Sheet
4
Fuel & Water Drainage Provision
1.4 m³/s
DSE
over/under frequency phases sequence
Transportation Tested Single Point Lifting Facility & Forklift Pockets
Gen-set Enclosure Specification (Optional)
Enclosure Type
Anticorrosive Protection
Access Doors
Drainage
Water Fill
Cable Access
Emergency Stop
Canopy RAL Color
Chassis RAL Color
78 dBA @ 7 meter
Radiator Water Filling Provision
Cable Inlet and Outlet Provision
External Emergency Push Button
RAL 2000
Type
Open
Enclosed
Length (mm)
4600
RAL 9011
Shipping Data
over/under voltage over under frequncy
Weight (kg)
8000
10900
Width (mm)
2222
Height (mm)
2508
Gen-set text alarm log Engine hours history log
for more features we can use higher controler
Event and Performance Log
20 feet ISO HQ Continer
Auto mains failure (AMF) applications including remote communication, user configuration and
complete gen-set monitoring and protection, ready for generators with 3 ph 4 wire/3 ph 3 wire/
mono ph
oil pressure fuel level optional
coolant temprature coolant level optional