2100
1150 x 1045
FLASHING BY SPECIALIST
TIMBER BALUSTRADE TO
CLIENTS SPECIFICATION
EXISTING BRAAI ROOM
EXISTING
VIBRECRETE WALL
EXISTING VIBRECRETE
WALL
830
FFL 0.000
WALL PLATE LVL
2.400
D&W HEIGHT
2.100
RIDGE LINE
3.600
11503001110950
BOUNDARYLINE
SCALE 1:100
NORTH WEST ELEVATION
EGL
BOUNDARYLINE
3510
399
1410
1150 x 545
75mmX50mm PURLINS AT 1000mm C/C. ON
250 MICRON PVC ON S.A. PINE TRUSSES AT
1000mm CENTERS.
FOUNDATION BRICK WALL
WITH AIR BRICKS FOR VENTILATION
INSTALL NEW 125 X 100mm PVC GUTTER WITH 75mm
DIAMETER DOWNPIPE TO DISCHARGE INTO 110mm
DIAMETER UPVC STORMWATER PIPE TAKEN TO STREET
SCALE 1:100
EGL
WALL PLATE LVL
2.400
1110399
FFL 0.000
D&W HEIGHT
2.100
3002100
14102100
3510
75mmX50mm PURLINS AT 1000mm C/C. ON
250 MICRON PVC ON S.A. PINE TRUSSES AT
1000mm CENTERS.
FLASHING BY SPECIALIST
EXISTING
VIBRECRETE WALL
SOUTH EAST ELEVATION
830
BOUNDARYLINE
RIDGE LINE
3.600
ALL EXPOSED TIMBER TO BE
TREATED TO SUPPLIERS
SPECIFICATIONS
1150 x 1045
FOUNDATION BRICK WALL
WITH AIR BRICKS FOR VENTILATION
INSTALL NEW 125 X 100mm PVC GUTTER WITH 75mm
DIAMETER DOWNPIPE TO DISCHARGE INTO 110mm
DIAMETER UPVC STORMWATER PIPE TAKEN TO STREET
SOUTH WEST ELEVATION
SCALE 1:100
BOUNDARYLINE
D&W HEIGHT
2.100
WALL PLATE LVL
2.400
2100
3510
T. AND G. S.A. PINE
112 x 15mm
BARGE BOARD
1150 x 1045
FOUNDATION BRICK WALL
WITH AIR BRICKS FOR VENTILATION
EXISTING DWELLING
EXISTING
VIBRECRETE WALL
500
300
EGL
95011101150399
FFL 0.000
RIDGE LINE
3.600
1410
75mmX50mm PURLINS AT 1000mm C/C. ON
250 MICRON PVC ON S.A. PINE TRUSSES AT
1000mm CENTERS.
BOUNDARYLINE
EGL
D&W HEIGHT
2.100
21001410
RIDGE LINE
3.600
2100
112 x 15mm
BARGE BOARD
FOUNDATION BRICK BALL
WITH AIR BRICKS FOR VENTILATION
EXISTING VIBRECRETE WALL
NORTH EAST ELEVATION
SCALE 1:100
500
3003991110
FFL 0.000
3510
EXISTING DWELLING
WALL PLATE LVL
2.400
75mmX50mm PURLINS AT 1000mm C/C. ON
250 MICRON PVC ON S.A. PINE TRUSSES AT
1000mm CENTERS.
T. AND G. S.A. PINE
FFL 0.110
RIDGE LINE
3.710
SCALE 1:50
SECTION A-A
D&W HEIGHT
2.210
EGL
399
2400
2400
3510
EXISTING DWELLING
152x50mm BEARER BEAM
500
76x50mm JOIST
TIMBER FLOOR TO CLIENTS
SPECIFICATION
500
2100
BOUNDARYLINE
300
WALL PLATE LVL
2.510
1110
SUPPORT BEAMS
75mmX50mm PURLINS AT 900mm C/C. ON
250 MICRON PVC ON S.A. PINE TRUSSES AT
1000mm CENTERS
75 x 50mm PURLINS
EXISTING VIBRECRETE WALL
800 x 300
CONCRETE
FOUNDATION
800 x 300
CONCRETE
FOUNDATION
38x 38mm S.A. PINE BATTERNS
@ MAX. 450 C/C
WENDY HOUSE
TIMBER
12mm EVERITE NUTEC FIBRE
CEMENT FLAT SHEETS
INSTALLED ON INTERNAL FACADES FOR
FIRE PROTECTION
INSTALL NEW 125 X 100mm PVC GUTTER WITH 75mm
DIAMETER DOWNPIPE TO DISCHARGE INTO 110mm
DIAMETER UPVC STORMWATER PIPE TAKEN TO STREET
OWNER:
DESCRIPTION:
DRAWING:
ARCHITECT:
REGISTRATION NUMBER:
DRAWN:
SCALE:
DATE:
DRAWING NUMBER:
MR HEYS
AS BUILT
WENDY HOUSE ON
ERF 2147 ,
ABALONE STREET,
RICHWOOD, CAPE TOWN
ELEVATIONS AND
SECTION
ANDRE F DU TOIT
6234
DAVID DINSDALE
1:100 / 1:50 / AS SHOWN
NOVEMBER 2014
14/11/16/02
NOTE:
DRAWINGS MUST BE READ IN
CONJUNCTION WITH EACH OTHER