SCADA ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Typically, remote stations have the added capability to be interfaced by field operators via hand held devices to perform diagnostic and repair operations. The communications network is the medium for transporting information between remote stations and the MS. This is performed using telephone line, cable, or radio frequency. If the remote site is too isolated to be reached via direct radio signal, a radio repeater is used to link the site.  Simulation tools used to aid the operator in preventing disturbances. Simulation is used when the system which is to be analyse or design is complex to use analytical techniques (like aerodynamics). Simulation models can be descriptive and physical. Simulation models that are formulated called descriptive models. Physical models mostly are time-discrete showing the  act and interact of entities of a system. These models can be built after many steps involving computer programs. The state of the system changes as a consequence of events in the system . These events are considered to occur at discrete times; models are called discrete event simulation models. Simulation languages   Most well-known simulation languages are GASP IV, GPSS and SIMSCRIPT II.1
The process can be Industrial: include those of  manufacturing ,  production ,  power generation ,  fabrication , and  refining ,  Infrastructure  : include  water treatment  and distribution, wastewater collection and  treatment , oil and gas pipelines, electrical power transmission and distribution, and large communication systems.  Facility based  : including buildings, airports, ships, and space stations. They monitor and control  HVAC , access, and energy consumption.  HVAC " heating ,  ventilating , and  air conditioning " is sometimes referred to as  climate control   Little More About SCADA A SCADA system manages electricity distribution by collecting data from, and issuing commands to, geographically remote field control stations from a centralized location. In the Oil and Gas industry, refining and processing facilities use distributed control systems (DCS) while holding facilities and distribution systems utilize SCADA technology. The water supply infrastructure utilizes DCS for the processing operations but use SCADA technology for distribution operations. A waste treatment plant runs similar to that of the water supply infrastructure.
Suppose you have a simple electrical circuit consisting of a switch and a light.  Like this This circuit allows an operator to watch the light ( ) and know whether the switch is open or closed. The switch may indicate that a  motor is running or stopped , or whether a  door is open or closed , or even whether there has been a  fault or the equipment is working . So far there is nothing special about this.  But now imagine that the switch and the lamp were  100 kilometres apart . Obviously we couldn't have an electrical circuit this large, and it would now be a problem involving  communications equipment   Now complicate the problem a bit further.   Imagine we had  2000 such circuits . We could not afford  2000 communications circuits.  However someone found that we could use one communications circuit by sharing it. First we send the status  (open/closed or 0/1)  of the first circuit. Then we send the status of the second circuit, and so on. We need to indicate which circuit the status applies to when we send the data. The poor operator at the other end still has a problem. He has to watch all  2000 circuits . To simplify his task, we could use  a computer .  The computer would monitor all circuits, and tell the operator when he needs to look at a particular circuit. The computer will be told what the normal state of the circuit is and what state is an "alarm". It monitors all circuits, and informs the operator when any circuit goes into alarm. Simply called  SCADA .
Breaker Mechanism CT VT Transducer RTU Station computer Central control  (SCADA) Protective relay Mimic board Analog meters Monitoring & Control of local system using RTU: Automatic functions for local control performed by regulators, as well as sequence control performed by relays are integrated as software functions in the RTU.
One of key processes of  SCADA  is the ability to monitor an entire system in real time ( run with relatively little human intervention) . This is facilitated by data acquisitions including meter reading, checking statuses of sensors, etc.  The  SCADA  software is a graphical package using a Window NT Operation System.  The system, manufactured by  Power Measurement Ltd (PML),  provides the programming necessary to incorporate actual  AutoCAD  campus maps and diagrams, and to display real time information on top of the graphic background.
TECHNICAL FUNCTIONS OF SCADA: The SCADA system provides the following functions: Data acquisition: The basic information of the power system collected is called the Data Acquisition. The data is collected by means of CTs, PTs and transducers. It provides the telemetry measurement and status indication to the operator.  Supervisory control: It enables the operator to remotely control the devices. For example open and close of the circuit breaker. Tagging: It prevents the device from unauthorized operation. Means it authorizes the device to perform the specific operation. Alarms: It informs the operator about the unnecessary events and undesired conditions. Logging (Recording): It logs all the operating entry, all alarms and other information. In other words it keeps the record of all the events. Load shading: It provides both the automatic and manual control tripping of load during the emergency. Trending: It plots the measurement on the selected time scale.
ESSENTIAL FEATURES OF SCADA: The simple layout of the SCADA system with its essential features is shown below in the fig: The SCADA system enables the operator to attain the complete knowledge of the system in a single room by means of display. Almost all the SCADA systems are computer based (Digital computer). This computer is located in the master unit. The master unit is the heart of the SCADA system, it comprises many of the i/p and o/p equipments to receive and send the control message from and to the RTU.
All the data of operations of RTU are transmitted to the master control unit and after collecting the information the data are feed back to the RTU.  Also master unit consists of several modems which are used to convert the digital into analog or analog into digital message depending upon the requirement. The received information of the master unit is displayed on VDU and then is printed for permanent record. In addition the SCADA system also comprises some more peripheral equipment such as control console, VDU, Alarms, Printers, D/A converter and Recording instruments.  Visual Display Unit (VDU) replaces mimic board to represent one line diagram, tabular display, bar charts, curves and event lists and used for entering commands to system. Modern system includes the color display which is used to distinguish b/w the different voltage levels. Also different colors differentiate the operator to understand the open and close of CB, also the flashing indication can be made which determines the change of the state of any device.  The audible alarms can be used to alert the operator from the fault or condition. The printers are used to have the permanent records of the events. The D/A converter are used to convert the digital information into the analog information, and then the information is supplied to the indicating or the recording instruments. The recording instruments are used to store the data of each remote station unit.
FUNCTIONAL DIAGRAM OF SCADA: The functional diagram of SCADA consists of several parts such as Data base, Data acquisition, Main machine interface and application program etc, are shown below in the fig:
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
PERFORMANCE MONITORING: The performance monitoring is used to enhance the operations availability of SCADA or control center systems. The basis requirement for the control center is the availability of the SCADA and its communication systems as well as RTU. All of these equipments must be greater than the rated capacity of the power system network. The power system must remains in the operation even at the time of the electrical faults, mechanical failure, and other environmental conditions. The basic philosophy of performance monitoring is that if any single fault occurs with the SCADA system, then the SCADA system should be able to withstand against that fault and operates without any disturbance. For that purpose several facilities such as fail over equipments, backup hardware and device are provided with the computer to bypass the faulty program in order to recover the operational status of the SCADA system. The availability is increased by the equipments redundancy. The software availability is increased by including the error detection, error handling, and fail over recovery and automatic restart facility. The performance monitoring nowadays is used in all SCADA ad other control centers b/c it provides the whole software availability and control of hardware.
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
LAYOUT OF VDU DISPLAY: The VDU display is used in SCADA to observe different states of the system. It enables the operator to find out the desired information in fast manner. The VDU display consists of two kinds of information (i.e. General information and specific information). The general information as the name implies is generally used for all display and is thus always shown on the screen. The specific information is used to any specified device, it is only used when is desired. The general information will of course different for different systems. But the most general layout of the VDU display is shown below in the fig:
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
MAIN TASKS IN POWER SYSTEM OPERATION: The main tasks of power system can be divided into the following categories: 1. Planning operations 2. Operation control 3. Operating accounting and financial control The above tasks are performed by the National control center, Regional control center, District control center and Major substation control rooms. 1) Planning of operations: Planning means the formulating and preparing actions before put into the use. Planning is done for next hour, next day, next week, next month, and next year and for long range. Planning tasks includes:    The  national load center  performs the following tasks: First of all load prediction followed by generator scheduling, spinning reserves, planning of reserves, planning of maintenance schedules, planning of energy resource, selection of energy resource, hydro-thermal generation co-ordination, planning of power exchange b/w two regions and planning of installation of HVDC lines.    The  Regional load center  performs the following tasks: First of all load prediction followed by generator scheduling, planning of reserves, planning of maintenance schedules and selection of load scheduling.    The  District load center  performs the following tasks: First of all short term planning in terms of regional level planning and then followed by planning of generation and reserves, and planning of load shedding in district.     The  Power station and sub-station control room  performs the following tasks:  Work planning for hourly, daily, weekly, monthly.
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
The  power station and sub-station control room  performs the following tasks: -Generation, start, stop function -Automatic restoration function -Control and protection functions Maintenance The  transmission sub-station  performs the following tasks: -Switching operation -Protective functions -Voltage control and reactive power compensation -Data collection -Load shedding instructions. 3) Operating accounting and financial control: The operating accounting deals with the data collection and evaluation and then preparation of the financial reports and billings. The task includes first of all the data collection regarding the power produced, and then billing on that power interchange for adjacent station, then estimate the performance of the power station, then estimate the price of the power available for the consumer.
Control Components of an Industrial Control System (ICS)
[object Object],[object Object],[object Object],[object Object]
SOME VIEWS ABOUT SCADA
 
See description in Annex. A Following Figure provides a generic SCADA Network Architecture that provides for an electric power example and an oil & gas/water example.
may consist of  line graphics  and  schematic symbols  to represent process elements, or may consist of  digital photographs  of the process equipment overlain with animated symbols. View of Mimic diagrams
 
 
 
 
Annex. A ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Firewall  – A device on a communications network that can be programmed to filter information based on the information content, source or destination. Human Machine Interface (HMI)  – The hardware or software through which an operator interacts with a controller. An HMI can range from a physical control panel with buttons and indicator lights to an industrial PC with a color graphics display running dedicated HMI software. Internet  – a system of linked networks that are worldwide in scope and facilitate data communication services. The Internet is currently a communications highway for millions of users. Input/Output (I/O)  – Module relaying information sent to the processor from connected devices (input) and to the connected devices from the processor (output). Light Tower  – A device containing series of indicator lights and an embedded controller used to indicate the state of a process based on an input signal. Local Area Network (LAN) –  A network of computers that span a relatively small space. Each computer on the network is called a node, has its own hardware and runs its own programs, but can also access any other data or devices connected to the LAN. Printers, modems and other devices can also be separate nodes on a LAN. Modem  – A device that allows a computer to communicate through a phone line. Management Information System (MIS)  – A software system for accessing data from production resources and procedures required to collect, process, and distribute data for use in decision making. Manufacturing Execution System (MES)  – Systems that use network computing to automate production control and process automation. By downloading “recipes” and work schedules and uploading production results, a MES bridges the gap between business and plant- floor or process-control systems.
OPC Client/Server  – Mechanism for providing interoperability between disparate field devices, automation/control, and business systems. Peer-to-Peer network  – A networking configuration where there is no server and computers connect with each other to share data. Each computer acts as both a client (information requestor) and a server (information provider). Pressure Sensor  – A sensor system that produces an electrical signal related to the pressure acting on it by its surrounding medium. Primary Domain Controller  – A Windows NT server responsible for managing domain information, such as login IDs and passwords. Printer  – A device which converts digital data to human readable text on a paper medium. Proximity Sensor  – A non-contact sensor with the ability to detect the presence of a target, within a specified range. Redundant Control Server  – A backup to the control server that maintains the current state of the control server at all times. Remote Terminal Unit (RTU)  – A computer with radio interfacing used in remote situations where communications via wire is unavailable. RTUs are usually used to communicate with remote field equipment. PLCs with radio communication capabilities are also used in place of RTUs.
Sensor  - A device that senses or detects the value of a process variable and generates a signal related to the value. Additional transmitting hardware is required to convert the basic sensor signal to a standard transmission signal. Sensor is defined as the complete sensing and transmitting device. Supervisory Control and Data Acquisition System (SCADA)  – Similar to a Distributed Control System with the exception of sub-control systems being geographically dispersed over large areas and accessed using Remote Terminal Servers. Temperature Sensor  – A sensor system that produces an electrical signal related to its temperature and, as a consequence, senses the temperature of its surrounding medium. Workstation  – A computer used for tasks such as programming, engineering, and design. Wide Area Network  – A network that spans a larger area than a LAN. It consists of two or more LANs connected to each other via telephone lines or some other means of connection. Wireless Device  – A device that can connect to a manufacturing system via radio or infrared waves to typically collect/monitor data, and also in cases to modify control set points.

More Related Content

What's hot

Scada system architecture, types and applications
Scada system architecture, types and applicationsScada system architecture, types and applications
Scada system architecture, types and applicationsUchi Pou
 
67469276 scada
67469276 scada67469276 scada
67469276 scadathangbd
 
How scada systems work
How scada systems workHow scada systems work
How scada systems workelprocus
 
PLC, DCS and PLC vs DCS Presentation by Jitender Singh Shekhawat
PLC, DCS and PLC vs DCS Presentation by Jitender Singh ShekhawatPLC, DCS and PLC vs DCS Presentation by Jitender Singh Shekhawat
PLC, DCS and PLC vs DCS Presentation by Jitender Singh ShekhawatJitender Singh Shekhawat
 
Scada classification
Scada classificationScada classification
Scada classificationAhmed Sebaii
 
Industrial automation (PLC, SCADA, VFD & HMI)
Industrial automation (PLC, SCADA, VFD & HMI)Industrial automation (PLC, SCADA, VFD & HMI)
Industrial automation (PLC, SCADA, VFD & HMI)Praveen Ramola
 
Basics of Automation, PLC and SCADA
Basics of Automation, PLC and SCADABasics of Automation, PLC and SCADA
Basics of Automation, PLC and SCADAIndira Kundu
 
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.kgaurav113
 
Scada
ScadaScada
ScadaTribi
 
Scada systems basics winnie mbau
Scada systems basics winnie mbauScada systems basics winnie mbau
Scada systems basics winnie mbauwinnie15
 
Scada and power system automation
Scada and power system automationScada and power system automation
Scada and power system automationShubham Kapoor
 
Industrial Automation (PLC, SCADA & HMI) by Nilesh Jha
Industrial Automation (PLC, SCADA & HMI) by Nilesh JhaIndustrial Automation (PLC, SCADA & HMI) by Nilesh Jha
Industrial Automation (PLC, SCADA & HMI) by Nilesh JhaNilesh Jha
 
PLC and SCADA in Industrial Automation
PLC and SCADA in Industrial AutomationPLC and SCADA in Industrial Automation
PLC and SCADA in Industrial AutomationNikhil nnk
 
123126804 scada
123126804 scada123126804 scada
123126804 scadathangbd
 

What's hot (20)

Scada system architecture, types and applications
Scada system architecture, types and applicationsScada system architecture, types and applications
Scada system architecture, types and applications
 
67469276 scada
67469276 scada67469276 scada
67469276 scada
 
How scada systems work
How scada systems workHow scada systems work
How scada systems work
 
PLC, DCS and PLC vs DCS Presentation by Jitender Singh Shekhawat
PLC, DCS and PLC vs DCS Presentation by Jitender Singh ShekhawatPLC, DCS and PLC vs DCS Presentation by Jitender Singh Shekhawat
PLC, DCS and PLC vs DCS Presentation by Jitender Singh Shekhawat
 
Introducing scada
Introducing scadaIntroducing scada
Introducing scada
 
Scada ppt
Scada  pptScada  ppt
Scada ppt
 
Scada classification
Scada classificationScada classification
Scada classification
 
Industrial automation (PLC, SCADA, VFD & HMI)
Industrial automation (PLC, SCADA, VFD & HMI)Industrial automation (PLC, SCADA, VFD & HMI)
Industrial automation (PLC, SCADA, VFD & HMI)
 
Basics of Automation, PLC and SCADA
Basics of Automation, PLC and SCADABasics of Automation, PLC and SCADA
Basics of Automation, PLC and SCADA
 
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.
WHAT IS SCADA AND BASIC KNOWLEDGE ABOUT IT.
 
Scada
ScadaScada
Scada
 
SCADA
SCADASCADA
SCADA
 
Scada systems basics winnie mbau
Scada systems basics winnie mbauScada systems basics winnie mbau
Scada systems basics winnie mbau
 
Variable frequency Drive
Variable frequency DriveVariable frequency Drive
Variable frequency Drive
 
Scada and power system automation
Scada and power system automationScada and power system automation
Scada and power system automation
 
PLC and SCADA
PLC and SCADAPLC and SCADA
PLC and SCADA
 
Industrial Automation (PLC, SCADA & HMI) by Nilesh Jha
Industrial Automation (PLC, SCADA & HMI) by Nilesh JhaIndustrial Automation (PLC, SCADA & HMI) by Nilesh Jha
Industrial Automation (PLC, SCADA & HMI) by Nilesh Jha
 
PLC and SCADA in Industrial Automation
PLC and SCADA in Industrial AutomationPLC and SCADA in Industrial Automation
PLC and SCADA in Industrial Automation
 
SCADA
SCADASCADA
SCADA
 
123126804 scada
123126804 scada123126804 scada
123126804 scada
 

Similar to Scada System

SCADA only for the advance version of the module
SCADA only for the advance version of the moduleSCADA only for the advance version of the module
SCADA only for the advance version of the moduleAJITTHAKUR68
 
SCADA (Supervisory Control & data Acquisation) PPT
SCADA (Supervisory Control & data Acquisation) PPTSCADA (Supervisory Control & data Acquisation) PPT
SCADA (Supervisory Control & data Acquisation) PPTDeepeshK4
 
Introduction To SCADA
Introduction To SCADAIntroduction To SCADA
Introduction To SCADAKunal gupta
 
Scada system Final Hakeem luqman pak version.pptx
Scada system Final Hakeem luqman pak version.pptxScada system Final Hakeem luqman pak version.pptx
Scada system Final Hakeem luqman pak version.pptxFaisalSheraz4
 
Airtificial Intelligence in Power System
Airtificial Intelligence in Power SystemAirtificial Intelligence in Power System
Airtificial Intelligence in Power SystemPratik Doshi
 
SCADA - Wikipedia, the free encyclopedia
SCADA - Wikipedia, the free encyclopediaSCADA - Wikipedia, the free encyclopedia
SCADA - Wikipedia, the free encyclopediaRaj Bakshi
 
Paper id 37201531
Paper id 37201531Paper id 37201531
Paper id 37201531IJRAT
 
Scada systems automating electrical distribution
Scada systems automating electrical distributionScada systems automating electrical distribution
Scada systems automating electrical distributionSHUBHAM SAINI
 
SCADA ... Supervisory control and data acquisition
SCADA ... Supervisory control and data acquisitionSCADA ... Supervisory control and data acquisition
SCADA ... Supervisory control and data acquisitionManohar Tatwawadi
 
Semester syllabus
Semester syllabusSemester syllabus
Semester syllabusbramesh316
 
Scada Based Online Circuit Breaker Monitoring System
Scada Based Online Circuit Breaker Monitoring SystemScada Based Online Circuit Breaker Monitoring System
Scada Based Online Circuit Breaker Monitoring SystemIOSR Journals
 
An introduction to scada fundamentals and implementation
An introduction to scada fundamentals and implementationAn introduction to scada fundamentals and implementation
An introduction to scada fundamentals and implementationRahul Mehra
 

Similar to Scada System (20)

SCADA only for the advance version of the module
SCADA only for the advance version of the moduleSCADA only for the advance version of the module
SCADA only for the advance version of the module
 
Fps scada
Fps scadaFps scada
Fps scada
 
03 scada.synopsis
03 scada.synopsis03 scada.synopsis
03 scada.synopsis
 
SCADA (Supervisory Control & data Acquisation) PPT
SCADA (Supervisory Control & data Acquisation) PPTSCADA (Supervisory Control & data Acquisation) PPT
SCADA (Supervisory Control & data Acquisation) PPT
 
Scada in hydropower plant
Scada in  hydropower plantScada in  hydropower plant
Scada in hydropower plant
 
Scada in hydropower plant
Scada  in  hydropower plantScada  in  hydropower plant
Scada in hydropower plant
 
Introduction To SCADA
Introduction To SCADAIntroduction To SCADA
Introduction To SCADA
 
Scada system Final Hakeem luqman pak version.pptx
Scada system Final Hakeem luqman pak version.pptxScada system Final Hakeem luqman pak version.pptx
Scada system Final Hakeem luqman pak version.pptx
 
Scada primer
Scada primerScada primer
Scada primer
 
Scada primer
Scada primerScada primer
Scada primer
 
Airtificial Intelligence in Power System
Airtificial Intelligence in Power SystemAirtificial Intelligence in Power System
Airtificial Intelligence in Power System
 
SCADA - Wikipedia, the free encyclopedia
SCADA - Wikipedia, the free encyclopediaSCADA - Wikipedia, the free encyclopedia
SCADA - Wikipedia, the free encyclopedia
 
Dcs vs scada
Dcs vs scadaDcs vs scada
Dcs vs scada
 
Paper id 37201531
Paper id 37201531Paper id 37201531
Paper id 37201531
 
Scada systems automating electrical distribution
Scada systems automating electrical distributionScada systems automating electrical distribution
Scada systems automating electrical distribution
 
SCADA ... Supervisory control and data acquisition
SCADA ... Supervisory control and data acquisitionSCADA ... Supervisory control and data acquisition
SCADA ... Supervisory control and data acquisition
 
Semester syllabus
Semester syllabusSemester syllabus
Semester syllabus
 
SCADA Overview
SCADA OverviewSCADA Overview
SCADA Overview
 
Scada Based Online Circuit Breaker Monitoring System
Scada Based Online Circuit Breaker Monitoring SystemScada Based Online Circuit Breaker Monitoring System
Scada Based Online Circuit Breaker Monitoring System
 
An introduction to scada fundamentals and implementation
An introduction to scada fundamentals and implementationAn introduction to scada fundamentals and implementation
An introduction to scada fundamentals and implementation
 

Scada System

  • 1.
  • 2. Typically, remote stations have the added capability to be interfaced by field operators via hand held devices to perform diagnostic and repair operations. The communications network is the medium for transporting information between remote stations and the MS. This is performed using telephone line, cable, or radio frequency. If the remote site is too isolated to be reached via direct radio signal, a radio repeater is used to link the site. Simulation tools used to aid the operator in preventing disturbances. Simulation is used when the system which is to be analyse or design is complex to use analytical techniques (like aerodynamics). Simulation models can be descriptive and physical. Simulation models that are formulated called descriptive models. Physical models mostly are time-discrete showing the act and interact of entities of a system. These models can be built after many steps involving computer programs. The state of the system changes as a consequence of events in the system . These events are considered to occur at discrete times; models are called discrete event simulation models. Simulation languages Most well-known simulation languages are GASP IV, GPSS and SIMSCRIPT II.1
  • 3. The process can be Industrial: include those of manufacturing , production , power generation , fabrication , and refining , Infrastructure : include water treatment and distribution, wastewater collection and treatment , oil and gas pipelines, electrical power transmission and distribution, and large communication systems. Facility based : including buildings, airports, ships, and space stations. They monitor and control HVAC , access, and energy consumption. HVAC " heating , ventilating , and air conditioning " is sometimes referred to as climate control Little More About SCADA A SCADA system manages electricity distribution by collecting data from, and issuing commands to, geographically remote field control stations from a centralized location. In the Oil and Gas industry, refining and processing facilities use distributed control systems (DCS) while holding facilities and distribution systems utilize SCADA technology. The water supply infrastructure utilizes DCS for the processing operations but use SCADA technology for distribution operations. A waste treatment plant runs similar to that of the water supply infrastructure.
  • 4. Suppose you have a simple electrical circuit consisting of a switch and a light. Like this This circuit allows an operator to watch the light ( ) and know whether the switch is open or closed. The switch may indicate that a motor is running or stopped , or whether a door is open or closed , or even whether there has been a fault or the equipment is working . So far there is nothing special about this. But now imagine that the switch and the lamp were 100 kilometres apart . Obviously we couldn't have an electrical circuit this large, and it would now be a problem involving communications equipment Now complicate the problem a bit further. Imagine we had 2000 such circuits . We could not afford 2000 communications circuits. However someone found that we could use one communications circuit by sharing it. First we send the status (open/closed or 0/1) of the first circuit. Then we send the status of the second circuit, and so on. We need to indicate which circuit the status applies to when we send the data. The poor operator at the other end still has a problem. He has to watch all 2000 circuits . To simplify his task, we could use a computer . The computer would monitor all circuits, and tell the operator when he needs to look at a particular circuit. The computer will be told what the normal state of the circuit is and what state is an "alarm". It monitors all circuits, and informs the operator when any circuit goes into alarm. Simply called SCADA .
  • 5. Breaker Mechanism CT VT Transducer RTU Station computer Central control (SCADA) Protective relay Mimic board Analog meters Monitoring & Control of local system using RTU: Automatic functions for local control performed by regulators, as well as sequence control performed by relays are integrated as software functions in the RTU.
  • 6. One of key processes of SCADA is the ability to monitor an entire system in real time ( run with relatively little human intervention) . This is facilitated by data acquisitions including meter reading, checking statuses of sensors, etc. The SCADA software is a graphical package using a Window NT Operation System.  The system, manufactured by Power Measurement Ltd (PML), provides the programming necessary to incorporate actual AutoCAD campus maps and diagrams, and to display real time information on top of the graphic background.
  • 7. TECHNICAL FUNCTIONS OF SCADA: The SCADA system provides the following functions: Data acquisition: The basic information of the power system collected is called the Data Acquisition. The data is collected by means of CTs, PTs and transducers. It provides the telemetry measurement and status indication to the operator. Supervisory control: It enables the operator to remotely control the devices. For example open and close of the circuit breaker. Tagging: It prevents the device from unauthorized operation. Means it authorizes the device to perform the specific operation. Alarms: It informs the operator about the unnecessary events and undesired conditions. Logging (Recording): It logs all the operating entry, all alarms and other information. In other words it keeps the record of all the events. Load shading: It provides both the automatic and manual control tripping of load during the emergency. Trending: It plots the measurement on the selected time scale.
  • 8. ESSENTIAL FEATURES OF SCADA: The simple layout of the SCADA system with its essential features is shown below in the fig: The SCADA system enables the operator to attain the complete knowledge of the system in a single room by means of display. Almost all the SCADA systems are computer based (Digital computer). This computer is located in the master unit. The master unit is the heart of the SCADA system, it comprises many of the i/p and o/p equipments to receive and send the control message from and to the RTU.
  • 9. All the data of operations of RTU are transmitted to the master control unit and after collecting the information the data are feed back to the RTU. Also master unit consists of several modems which are used to convert the digital into analog or analog into digital message depending upon the requirement. The received information of the master unit is displayed on VDU and then is printed for permanent record. In addition the SCADA system also comprises some more peripheral equipment such as control console, VDU, Alarms, Printers, D/A converter and Recording instruments. Visual Display Unit (VDU) replaces mimic board to represent one line diagram, tabular display, bar charts, curves and event lists and used for entering commands to system. Modern system includes the color display which is used to distinguish b/w the different voltage levels. Also different colors differentiate the operator to understand the open and close of CB, also the flashing indication can be made which determines the change of the state of any device. The audible alarms can be used to alert the operator from the fault or condition. The printers are used to have the permanent records of the events. The D/A converter are used to convert the digital information into the analog information, and then the information is supplied to the indicating or the recording instruments. The recording instruments are used to store the data of each remote station unit.
  • 10. FUNCTIONAL DIAGRAM OF SCADA: The functional diagram of SCADA consists of several parts such as Data base, Data acquisition, Main machine interface and application program etc, are shown below in the fig:
  • 11.
  • 12.
  • 13. PERFORMANCE MONITORING: The performance monitoring is used to enhance the operations availability of SCADA or control center systems. The basis requirement for the control center is the availability of the SCADA and its communication systems as well as RTU. All of these equipments must be greater than the rated capacity of the power system network. The power system must remains in the operation even at the time of the electrical faults, mechanical failure, and other environmental conditions. The basic philosophy of performance monitoring is that if any single fault occurs with the SCADA system, then the SCADA system should be able to withstand against that fault and operates without any disturbance. For that purpose several facilities such as fail over equipments, backup hardware and device are provided with the computer to bypass the faulty program in order to recover the operational status of the SCADA system. The availability is increased by the equipments redundancy. The software availability is increased by including the error detection, error handling, and fail over recovery and automatic restart facility. The performance monitoring nowadays is used in all SCADA ad other control centers b/c it provides the whole software availability and control of hardware.
  • 14.
  • 15. LAYOUT OF VDU DISPLAY: The VDU display is used in SCADA to observe different states of the system. It enables the operator to find out the desired information in fast manner. The VDU display consists of two kinds of information (i.e. General information and specific information). The general information as the name implies is generally used for all display and is thus always shown on the screen. The specific information is used to any specified device, it is only used when is desired. The general information will of course different for different systems. But the most general layout of the VDU display is shown below in the fig:
  • 16.
  • 17.
  • 18.
  • 19. MAIN TASKS IN POWER SYSTEM OPERATION: The main tasks of power system can be divided into the following categories: 1. Planning operations 2. Operation control 3. Operating accounting and financial control The above tasks are performed by the National control center, Regional control center, District control center and Major substation control rooms. 1) Planning of operations: Planning means the formulating and preparing actions before put into the use. Planning is done for next hour, next day, next week, next month, and next year and for long range. Planning tasks includes:  The national load center performs the following tasks: First of all load prediction followed by generator scheduling, spinning reserves, planning of reserves, planning of maintenance schedules, planning of energy resource, selection of energy resource, hydro-thermal generation co-ordination, planning of power exchange b/w two regions and planning of installation of HVDC lines.  The Regional load center performs the following tasks: First of all load prediction followed by generator scheduling, planning of reserves, planning of maintenance schedules and selection of load scheduling.  The District load center performs the following tasks: First of all short term planning in terms of regional level planning and then followed by planning of generation and reserves, and planning of load shedding in district.  The Power station and sub-station control room performs the following tasks: Work planning for hourly, daily, weekly, monthly.
  • 20.
  • 21. The power station and sub-station control room performs the following tasks: -Generation, start, stop function -Automatic restoration function -Control and protection functions Maintenance The transmission sub-station performs the following tasks: -Switching operation -Protective functions -Voltage control and reactive power compensation -Data collection -Load shedding instructions. 3) Operating accounting and financial control: The operating accounting deals with the data collection and evaluation and then preparation of the financial reports and billings. The task includes first of all the data collection regarding the power produced, and then billing on that power interchange for adjacent station, then estimate the performance of the power station, then estimate the price of the power available for the consumer.
  • 22. Control Components of an Industrial Control System (ICS)
  • 23.
  • 25.  
  • 26. See description in Annex. A Following Figure provides a generic SCADA Network Architecture that provides for an electric power example and an oil & gas/water example.
  • 27. may consist of line graphics and schematic symbols to represent process elements, or may consist of digital photographs of the process equipment overlain with animated symbols. View of Mimic diagrams
  • 28.  
  • 29.  
  • 30.  
  • 31.  
  • 32.
  • 33. Firewall – A device on a communications network that can be programmed to filter information based on the information content, source or destination. Human Machine Interface (HMI) – The hardware or software through which an operator interacts with a controller. An HMI can range from a physical control panel with buttons and indicator lights to an industrial PC with a color graphics display running dedicated HMI software. Internet – a system of linked networks that are worldwide in scope and facilitate data communication services. The Internet is currently a communications highway for millions of users. Input/Output (I/O) – Module relaying information sent to the processor from connected devices (input) and to the connected devices from the processor (output). Light Tower – A device containing series of indicator lights and an embedded controller used to indicate the state of a process based on an input signal. Local Area Network (LAN) – A network of computers that span a relatively small space. Each computer on the network is called a node, has its own hardware and runs its own programs, but can also access any other data or devices connected to the LAN. Printers, modems and other devices can also be separate nodes on a LAN. Modem – A device that allows a computer to communicate through a phone line. Management Information System (MIS) – A software system for accessing data from production resources and procedures required to collect, process, and distribute data for use in decision making. Manufacturing Execution System (MES) – Systems that use network computing to automate production control and process automation. By downloading “recipes” and work schedules and uploading production results, a MES bridges the gap between business and plant- floor or process-control systems.
  • 34. OPC Client/Server – Mechanism for providing interoperability between disparate field devices, automation/control, and business systems. Peer-to-Peer network – A networking configuration where there is no server and computers connect with each other to share data. Each computer acts as both a client (information requestor) and a server (information provider). Pressure Sensor – A sensor system that produces an electrical signal related to the pressure acting on it by its surrounding medium. Primary Domain Controller – A Windows NT server responsible for managing domain information, such as login IDs and passwords. Printer – A device which converts digital data to human readable text on a paper medium. Proximity Sensor – A non-contact sensor with the ability to detect the presence of a target, within a specified range. Redundant Control Server – A backup to the control server that maintains the current state of the control server at all times. Remote Terminal Unit (RTU) – A computer with radio interfacing used in remote situations where communications via wire is unavailable. RTUs are usually used to communicate with remote field equipment. PLCs with radio communication capabilities are also used in place of RTUs.
  • 35. Sensor - A device that senses or detects the value of a process variable and generates a signal related to the value. Additional transmitting hardware is required to convert the basic sensor signal to a standard transmission signal. Sensor is defined as the complete sensing and transmitting device. Supervisory Control and Data Acquisition System (SCADA) – Similar to a Distributed Control System with the exception of sub-control systems being geographically dispersed over large areas and accessed using Remote Terminal Servers. Temperature Sensor – A sensor system that produces an electrical signal related to its temperature and, as a consequence, senses the temperature of its surrounding medium. Workstation – A computer used for tasks such as programming, engineering, and design. Wide Area Network – A network that spans a larger area than a LAN. It consists of two or more LANs connected to each other via telephone lines or some other means of connection. Wireless Device – A device that can connect to a manufacturing system via radio or infrared waves to typically collect/monitor data, and also in cases to modify control set points.