  1. 1. DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING A PRESENTATION ON 132 KV Substation, kasia,KUSHINAGAR under uppcl ,lucknow Session: - 2015-2016 Presented By:- ABRAR AHAMED E.N FINAL YEAR 1346521001
  2. 2. OUTLINE OF PRESENTATION INTRODUCTION  GENERAL DISCUSSION ON SUB STATION  FEEDERS  Equipments :-  Lightning arrester (L.A.)  Capacitive voltage transformer  Wave trap (PLCC)  Isolator  Instrument transformers :-C.T. & P.T.  Circuit breaker :- definition & types  Bus bar  Power transformer:-introduction & main parts  Protective relays :- introduction & Buchhloz relay  SUMMARY
  3. 3. INTRODUCTION  The creation of Uttar Pradesh Power Corporation Ltd. (UPPCL) on January 14, 2000 is the result of power sector reforms and restructuring in UP (India) which is the focal point of the Power Sector, responsible for planning and managing the sector through its transmission, distribution and supply of electricity.  For efficient operation & management Uttar Pradesh Power Corporation Limited (UPPCL) is further restructured into:-  Dakshinanchal Vidyut Vitaran Nigam Limited (DVVNL) - Agra Zone  Madhyanchal Vidyut Vitaran Nigam Limited (MVVNL) – Lucknow Zone  Pashchimanchal Vidyut Vitaran Nigam Limited (PVVNL) - Meerut Zone  Purvanchal Vidyut Vitaran Nigam Limited (PUVVNL) - Varanasi Zone  Kanpur Electricity Supply Company(KESCO) - Kanpur City  Lucknow Electricity Supply Administration (LESA) - Lucknow City  Uttar Pradesh Power Transmission Limited (UPPTCL) - State Transmission Utility
  4. 4. SUBSTATION Part of Electricity Generation Transmission of Electricity Distribution of Electricity Voltage is Transform High to Low or vice-versa using Transformers Ex.-400kV/220kV substation 220kV/132kV substation 132kV/33kV substation 33kV/11kV substation 33kV/.4kV substation
  5. 5. 132 kV substation KASIA It is divided into two parts:- A. Panel Section  Control Panel Section  Relay and Protection Panel Section B. Switch Yard  132kV section  33kV section C. Battery Room (Extra)
  6. 6. A. Panel Section It is a room which contains all types of panels. It has two sections:-  Control Panel Section It contain panels related to controlling of instruments. E.g.:- feeder panel, transformer panel, etc.  Relay And Protection Panel Section It contains panels related to relay systems and protection systems. E.g.:- Relay panel, line protection panel, etc.
  7. 7. B. Switch Yard It is the field where components used in controlling supply and measuring supply(incoming and outgoing) are placed. Some of these components are:-  C.Bs  Isolators  C.Ts  P.Ts  L.As  Transformers, etc.
  8. 8. SINGLE LINE DIAGRAM OF 132 KV KASIA
  9. 9. CT 132 Kv incoming from DEORIA LIGHTNING ARRESTORS CVT WAVE TRAP CIRCUIT BREAKER LINE ISOLATOR BUS PT with BUS ISOLATOR ISOLATOR LA LA with EARTH SWITCH 33 kV OUTPUT ISOLATORS with EARTH SWITCH CT CAPACITOR BANK MAIN TRANSFORMER PT with BUS ISOLATOR CB ISOLATOR CT CB EQUIPMENTS FLOW SIMILAR TO 33kV SIMILAR TO 11kV (DITRIBUTION)
  10. 10. DEORIA-132 kV GORAKHPUR-132 kV FEEDERS HATA-33 kV KUSHINAGAR-33 kV KASIA/HATA TH-33kV PADRAUNA-33kV RAVINDRNAGR-33 kV FAJILNAGAR-33 kV RAMKOLA-33 kV SABYA-33 kV KASIA-33 kV 132/33kV SUB STATION KASIA SUGAR MILL-132 kV RAJA PAKAD-132 kV
  11. 11. -EQUIPMENTS - LIGHTENING ARRESTER-  Protect the Insulation & Conductors of the system from damaging effect of LIGHTNING
  12. 12. CAPACITIVE VOLTAGE TRANSFORMER Step down extra high voltage signals. Provide a low voltage signal. For MEASUREMENT of voltage. To operate a protective relay.
  13. 13. WAVE TRAP (PLCC) POWER LINE CARRIER COMMUNICATION Exchange of data and transfer of messages between substations. WAVE TRAP-TRAPPING the unwanted waves.
  14. 14. ISOLATORS  Used for completely DE-ENERGISED the electrical circuit for SERVICE or MAINTENANCE.  Separate the circuit at NO LOAD CONDITION.
  15. 15. INSTRUMENT TRANSFORMERS INSTRUMENT TRANSFORMERS are used for measurement and protective applications together with equipments such as meters & relays Types- A) CURRENT TRANSFORMER B) POTENTIAL TRANSFORMER
  16. 16. CIRCUIT BREAKER Automatically Operated ELECTRICAL SWITCH. Designed to protect the ckt. from overload or SHORT CKT. Separate Healthy & Faulty Section of ckt. Operate at ON LOAD Condition.
  17. 17. VACUUM CIRCUIT BREAKERS Vacuum circuit breakers are circuit breakers which are used to protect medium and high voltage circuits from dangerous electrical situations AIR-BLAST CIRCUIT BREAKER Fast operations ,suitability for repeated operation , auto reclosed , unit type multi break constructions ,simple assembly , modest maintenance are some of the main features of air blast circuit breakers. A compressors plant necessary to maintain high air pressure in the air receiver. TYPES OF CIRCUIT BREAKERS OIL CIRCUIT BREAKER A high-voltage circuit breaker in which the arc is drawn in oil to dissipate the heat and extinguish the arc; the intense heat of the arc decomposes the oil . SULPAR HEXAFLUORIDE CIRCUIT BREAKER (SF6) Sulpharhexafluoride (SF6) gas is used as the arc quenching medium . The SF6 is an electronegative gas and has a strong tendency to absorb free electrons. Circuit breakers have been developed for voltage 115KV to 230KV , power rating10 MVA
  18. 18. BUS BAR  A bus bar is a conducting bar that carries heavy currents to supply several electric circuits.  Made up of copper rod or thin walled tubes. TYPES:- - MAIN BUS BAR. - AUXILIARY BUS BAR
  19. 19. POWERTRANSFORMER A Static Device. Transfer Power from One circuit to another circuit No Change in FREQUENCY. Principle-FARADAY ’s LAW of ELECTROMAGNETIC INDUCTION. Types- 1. STEP UP TRANSFORMER:: O/P Voltage > I/P Voltage. 2. STEP DOWN TRANSFORMER :: O/P Voltage < I/P Voltage.
  20. 20. FIGURE of POWERTRANSFORMERs
  21. 21. PARTS OF TRANSFORMER  core  Winding(H.V winding, L.V winding, tertiary winding)  transformer OILS  PRESSURE RELIEF VALVE  BREATHER  Conservator  RADIATER  Tap changer  Tank
  22. 22. Protective Relay is a sensing device and is designed to detect operating conditions on an electric circuit. It trips the circuit breaker when fault is detected. PROTECTIVE RELAYS TYPESOFRELAY  Overcurrent relay  Differential relay  Tripping relay  Directional Relay  Auxiliary Relay
  23. 23.  A gas actuated relay.  it is installed in b/w the conservator and the main tank.  PRINCIPLE:- Whenever a fault occurs inside the transformers, the oil of the tank gets overheated and gases are generated. The heat generated by the high local current causes the transformer oil to decompose and produce gas which can be used to detect the faults. BUCHHOLZRELAY
  24. 24. BATTERY ROOM  DC battery shell be installed in the power house for  Emergency power.  Protection.  Alarm and indication.
  25. 25. TRANSFORMERS Also known as the heart of substations. These are used to reduce the voltages at appropriate levels CURRENT VOLTAGE TRANSFORMERS It is a used in power systems to step down extra high voltage signals and provide a low voltage signal, for measurement or to operate a protective relay WAVETRAP Traps the high frequency signalsISOLATORS Used for maintenance of the circuit in no load condition CIRCUIT BREAKER used to protect the equipment by opening the circuit for over current and over voltages LIGHTINING ARRESTER Used for protecting the equipment from surge voltages SUMMARY OF EQUIPMENTs RELAY Used to sense the faults

×