Sun SPARC Enterprise
T5440
Rack Servers
Train-the-Trainer Course
Presenter



Sun Microsystems, Inc.
Sun Confidential
CDA Required
                           1
NDA Notification
This presentation contains information related to projects that are currently in planning
and/or development stages. This information represents the current intentions of Sun
Microsystems, Inc. However, all aspects of these projects, including, but not limited to
funding, availability, shipping dates, configurations, capacities, performance, and all
other characteristics are subject to change and/or cancellation without notice.
This material is confidential to Sun Microsystems and should be disclosed to non-
employees only under the terms of an executed confidential-disclosure agreement.
Distribution of this material to Sun Field Representatives should be done through the
GSO CDA process. Under no circumstances should these roadmaps be given directly to
a Sun Field Representative.
The information contained herein is considered privileged, confidential and protected
from disclosure. If you are not the intended recipient or their employee/agent
responsible for its delivery, you are requested to refrain from any duplication or
distribution of this message or its contents, in respect of the rights of the designated
recipient and sender and to delete it from your computer.




                                   Sun Internal and Approved Partners Only                  2
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC T2 Plus
• Sun SPARC Enterprise T5440 server
   > Overview of Features
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...


                           Sun Internal and Approved Partners Only   3
Industry's Most Highly Threaded Servers
Maximum Threading =
Higher Throughput, Greater Energy & Space Efficiency




                                                                              T5440
                                                                         Up to 256 Threads
                                    T5140/T5240
                                Up to 128 Threads

    T5120/T5220
   Up to 64 Threads
                      SB6320
                      US T2 blade
                               Sun Internal and Approved Partners Only                       4
UltraSPARC T2:                                                                              • Up to 8 cores @1.2GHz or 1.4GHz
TrueSystem On a Chip                                                                        • Up to 64 threads per CPU
                                                                                            • Up to 16 FB-DIMMs, 4 memory
                                                                                              controllers
       FB DIMM       FB DIMM      FB DIMM        FB DIMM
                                                                                                 > Up to 64GB memory (4GB DIMMs)
                                                                                                 > 2.5x memory BW of UltraSPARC T1
       FB DIMM       FB DIMM      FB DIMM        FB DIMM                                    • 8 x fully pipelined Floating Point units /
                                                                                              core, 1 per core
           MCU       MCU            MCU           MCU                                       • Dual 10Gbit Ethernet and PCI-E
                                                                                              integrated onto chip
      L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$
                                                                                            • 4MB L2 (8 banks) 16 way associative
                         Full Cross Bar
                                                                                            • Enhanced MAU/Security co-processor
      C0     C1
      FPU    FPU
                   C2
                   FPU
                           C3
                           FPU
                                 C4
                                 FPU
                                          C5
                                          FPU
                                                C6
                                                FPU
                                                         C7
                                                        FPU
                                                                                              per core
     MAU     MAU   MAU     MAU   MAU      MAU   MAU     MAU                                      > DES, 3DES, AES, RC4, SHA1,
                     DMA Sub-System                                                                SHA256, MD5, RSA to 2048 key,
                                                                                                   ECC,CRC32
        NIU                 Sys I/F
                                                                                            • Advanced Power saving features
      (E-net+)        Buffer Switch Core              PCI-E
                                                                                            • 65nm process technology
                         Power ~95W
                         <1.5W/thread         x8 @2.5GHz
  2x 10GE Ethernet                        4GBytes/s bi-directional
                                                              Sun Internal and Approved Partners Only                                      5
UltraSPARC T2 Processor
                                                                                                                  SPC SPARCv9 CMT Core
             L2 Data                                                                          L2 Data
             Bank 0                                                                           Bank 4              CCX Core-Cache Crossbar
              L2B0           SPARC    SPARC           SPARC              SPARC                 L2B4               L2$ Level 2 Cache Bank
             L2 Data
                             Core 0   Core 1          Core 5             Core 4
                                                                                              L2 Data             CLC Coherence & Link Controller
             Bank 1                                                                           Bank 5
                                                                                                                  MCU Memory Control Unit
              L2B1                                                                             L2B5
                                                                                                                  SIU System Interface Unit
                              L2       L2              L2                  L2
           MCU0                                                                                    MCU2           NCU Non-cacheable Unit
                       NCU




                             TAG0     TAG1            TAG5                TAG4                              FSR
                                                                                                                  MAC Media Access Controller




                                                                                       EFU
           MCU1                                                                                    MCU3

                                                                                                                  DMU Data Management Unit




                                                                   SIO
                                SII




              L2B3                             CCX                                             L2B7
     FSR                                                                    CCU                                   PEU PCI Express Unit
             L2 Data                                                                          L2 Data
             Bank 3                                                                           Bank 7
                              L2       L2              L2                  L2
              L2B2                                                                             L2B6
                             TAG2     TAG3            TAG7                TAG6
             L2 Data                                                                          L2 Data
             Bank 2                                                                           Bank 6


                             SPARC    SPARC           SPARC              SPARC
              DMU
                             Core 2   Core 3          Core 7             Core 6              RDP          TDS


              PEU


                                                                                                   RTX
             PSR               ESR              FSR                      MAC



For a video tour with Rick Hetherington, go to http://www.youtube.com/watch?v=B8DNexYcsa4
                                                 Sun Internal and Approved Partners Only                                                     6
UltraSPARC T2 Plus:                                                                                  • Per Socket
   Multi-Socket US T2                                                                                     > Up to 8 cores @1.2GHz or
Each Coherency Link 6.4GBytes/s per direction, 12.8GB/s total
                                                                                                             1.4GHz
   4 x Coherency links give Snoop bandwidth of 51.2GB/s                                                   > Up to 64 Threads per socket
                                                                            4x
                                                                         Coherency                        > 4MB L2$ 8 banks x 16 Way SA
                                                                           Links
                                                                                                          > Up to 8 FPU's, 1 per core
              FB-DIMM   FB-DIMM               FB-DIMM   FB-DIMM
                                                                                                          > Up to 8 Crypto cores, 1 per core
              FB-DIMM   FB-DIMM               FB-DIMM   FB-DIMM                                                    > DES, 3DES, AES, RC4, SHA1, SHA256,
                                                                                                                     MD5, RSA to 2048 key, ECC,CRC32
                   MCU                             MCU                                                         > 2 memory Controllers, 16 DIMMS
             CU               CU             CU               CU                                               > 25Read+13WriteGB/s Memory BW
        L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$                                                                        > One x8 PCIe interface
                           Full Cross Bar                                                             • Per system
        CO        C1     C2        C3   C4        C5     C6        C7                                     > 2 sockets glue-less
        FPU
        MAU
                 FPU
                MAU
                        FPU
                        MAU
                                  FPU
                                  MAU
                                        FPU
                                        MAU
                                                 FPU
                                                MAU
                                                        FPU
                                                        MAU
                                                                  FPU
                                                                  MAU
                                                                                                          > 4 sockets using UST2 Plus XBR
                                                                                                          > 16 or 32 PCIe lanes on 2 or 4
        System I/F                      PCI-Express                                                          Socket systems
                                                                                                      • 65nm process technology
             SSI                                        x8 @2.5GHz
             Bus         Power ~105W                     4GBytes/s
                         <1.5W/thread                   bi-directional

                                                                         Sun Internal and Approved Partners Only                                          7
UltraSPARC T2 Plus Processor
                                                         SPC SPARCv9 CMT Core
                                                         CCX Core-Cache Crossbar
                                                         L2$ Level 2 Cache Bank
                                                         CLC Coherence & Link Controller
                                                         MCU Memory Control Unit
                                                         SIU System Interface Unit
                                                         NCU Non-cacheable Unit
                                                         NCX Non-cacheable Crossbar
                                                         DMU Data Management Unit
                                                         PEU PCI Express Unit




               Sun Internal and Approved Partners Only                                 8
CMT Processor Comparison
                                  UltraSPARC T1              UltraSPARC T2      UltraSPARC T2 Plus
Technology                             90nm                       65nm                  65nm
# of Cores                                 8                         8                     8
# of Threads                              32                         64                   64
# of Sockets                               1                         1                   1–4
Core Frequency (Ghz)                   1 – 1.4                   1.2 – 1.4             1.2 – 1.4
Execution pipelines per core               1                         2                     2
Instructions per cycle per pipe            1                         1                     1
FPUs per chip                              1                         8                     8
I$ size (per core)                      16KB                       16KB                  16KB
D$ size (per core)                       8KB                        8KB                  8KB
L2$ size/Set Association           3MB/12-Way                 4MB/16-Way            4MB/16-Way
Memory Type                            DDR2                     FBDIMM-1              FBDIMM-1
Memory Bandwidth (GB/s)                  21.3                42READ + 21WRITE      25READ + 13WRITE
Coherence Bandwdth (GB/s)                  -                          -         4 x (6.4READ +6.4WRITE)
IO Bus                                  JBUS                     x8 PCIe               x8 PCIe
IO Bandwidth (GB/s)                      2.5                       2+2                   2+2
On-chip Networking                         -                    2 x 10GE                   -
Crypto Acceleration                      RSA              RSA, RC4, DES, 3DES, AES, SHA1-256, MD5
Power (Watts, Watts/thread)           72, 2.25                     95, 1.5           105, 1.6 *



                                    Sun Internal and Approved Partners Only                               9
UltraSPARC T2 Plus 2-Socket System

                                                               Coherency Links
       Dual Channel                Dual Channel                                              Dual Channel                 Dual Channel
         FBDIMM                      FBDIMM                                                       FBDIMM                    FBDIMM




      Memory Controller           Memory Controller                                              Memory Controller        Memory Controller

   Coherence      Coherence    Coherence    Coherence                                  Coherence           Coherence   Coherence   Coherence
     Unit             Unit        Unit          Unit                                       Unit              Unit        Unit            Unit


  UltraSPARC T2 Plus Cores, Crossbar, L2$                                             UltraSPARC T2 Plus Cores, Crossbar, L2$
               (8 cores, 64 threads, 4MB L2$)                                                         (8 cores, 64 threads, 4MB L2$)



            PCI-Express             NCU, DMU           NCX                                          PCI-Express            NCU, DMU             NCX




                                  System IO (Network, Disk, etc.)

                                                       Sun Internal and Approved Partners Only                                                        10
UltraSPARC T2 Plus 4-Socket System

                                                           6.4GB/s                                  6.4GB/s




                                            Dual Channel
                                  FBDIMM




                                                                                             Dual Channel
              US T2 Plus                                                                                                US T2 Plus




                                                                                                              FBDIMM
PCI-Express                                                                                                                           PCI-Express
                 8 Cores       6.4GB/s                                                         6.4GB/s                    8 Cores
                                  6.4GB/s                                                   6.4GB/s
               64 Threads                                           Coherence                                            64 Threads



                                           Dual Channel
                4MB L2$                                                                                                   4MB L2$
                                                                 Coherence(4)
                                                                     Hubs
                                 FBDIMM




                                                                                             Dual Channel
                                                                                                              FBDIMM
                                                                  Coherence
                                                                   Coherence
                                                                   UltraSPARC
                                                                  Hubs (4)
                                                                   Hubs (4)
                                                                    HubsPlus
                                                                     T2 (4)
                                   6.4GB/s                             XBR                  6.4GB/s
                                                                     44 ports/hub
                                                                      ports/hub
                               6.4GB/s                                 4 ports/hub                      6.4GB/s
                                            Dual Channel




                                                                     inin each dir
                                                                        each dir
                                  FBDIMM




                                                                                              Dual Channel
                                                                         in each dir




                                                                                                              FBDIMM
PCI-Express   US T2 Plus
                 VF                                                       4 ports/hub                                   US T2 Plus
                                                                                                                                      PCI-Express
                                                                      6.4GB/s per port
                               6.4GB/s                                                       6.4GB/s
                  8 Cores
                  8 Cores                                                in each dir     6.4GB/s                          8 Cores
                                  6.4GB/s
                 64 Threads
              8 Threads/Core                                                                                             64 Threads
                                           Dual Channel
                                 FBDIMM




                 4MB L2$                                                                                                  4MB L2$
                                                                                               Dual Channel

                4MB L2$                                                                                        FBDIMM




                                                             6.4GB/s              6.4GB/s



                                               Sun Internal and Approved Partners Only                                                              11
US T2 Plus XBR Coherency Hub Chips...
  • 4 XBR chips in a system                                                 • XBR routes non-cacheable PIOs to the
  • Each operates in its own                                                  appropriate IO device
    Coherency Plane(CP)                                                            > Forwarded to the Zambezi that owns the
       > A region of addressable space, unique                                            address space for processing
               to that plane                                                • DMA reads and writes are done
       >       Each XBR only tracks addresses in its
               own space                                                      through cachable memory space just
       >       Serializes accesses to coherent loads,                         like processor initiated memory
               stores and writebacks (TSO model)                              accesses
       >       40 bit Physical Address used
                                                                            • CP links are based on an FB-DIMM
       >       VF Snoop links to pass transactions
                                                                              physical interface, but a Sun protocol
  • Cacheable transactions                                                         > 6.4GBps/Direction/Port
                – Most Memory transactions                                         > 51.2GB/s bandwidth total
  • Non-Cacheable transactions                                                     > CP links are tolerant to a single lane failure
                – IO, Non-cachable memory,                                           (14 lanes per link)
                  Interrupts etc.                          Coherency Plane         > CRC and replay features in the protocol
                           Mem Interleave by
                                                             Designator              allow no-stop recovery
                           Coherency Plane
 Cachable/
Non-Cachable
                           Coherency plane
                              Designator
                             (512B/1GB)                                            > Memory structures are Parity protected

39               31 30       40 Bit Physical Address             10 9 8 7                        0
                                                       Sun Internal and Approved Partners Only                                    12
UltraSPARC T2/Plus CPU Core Block Diagram
                                                            • IFU – Instruction Fetch Unit
                                                               > 16 KB I$, 32B lines, 8-way SA
    TLU          IFU                                           > 64-entry fully-associative ITLB
                                                            • EXU0/1 – Integer Execution Units
                                                              > 4 threads share each unit
                                                              > Executes one integer
                                                                instruction/cycle
          EXU0         EXU1
                                                            • LSU – Load/Store Unit
                                                              > 8KB D$, 16B lines, 4-way SA
                                 MMU/                         > 128-entry fully-associative DTLB
                                 HWTW                       • FGU – Floating/Graphics Unit
                                                            • SPU – Stream Processing Unit
                                                              > Cryptographic acceleration
  SPU     FGU      LSU
                                                            • TLU – Trap Logic Unit
                                                              > Updates machine state, handles
                                                                 exceptions and interrupts
                                                            • MMU – Memory Management Unit
                                                              > Hardware tablewalk (HWTW)
                   Gasket
                                                                 – TLB miss handled by hardware
                                                              > 8KB, 64KB, 4MB, 256MB pages
                  xbar/L2
                              Sun Internal and Approved Partners Only                              13
Floating Point Unit

    • Each Core has its own Floating Point Unit. This removes
      completely the 2% FP restriction of T1.
    • Only a 6 cycle penalty to the FPU
      > T1 required upwards of 28 cycles
    • Fully-pipelined (except divide/sqrt)
            Data
      > Divide/sqrt in parallel with add or multiply operations of other
        threads
    • Full VIS 2.0 implementation in hardware, no emulation
    • FPU performs integer multiply, divide, population count
    • Multiplier incorporates enhancements for offloading modular
      arithmetic operations to the Crypto Unit



●


●                           Sun Internal and Approved Partners Only        14
UltraSPARC T2 Plus Crypto Performance
         Absolute maximums, measured by engineering using micro-benchmarks
               Application throughputs will be lower than these numbers

                                          Iterations/    Block      Cycles/
 Function             Comment                Block      (bytes)      Block          GB/S

DES                  2 rounds/cycle        16 rounds       8          8/9+           12.0
3DES                 2 rounds/cycle        48 rounds       8         25/24            4.0
RC4               3 overlapped cycles           1          1         37683           12.0
                Data into 44 words




                                                                                                  with UltraSPARC T2 Plus
AES-128K         4 words                        -          -           32              -
AES-192K         6 words into 52 words          -          -           37              -




                                                                                                      New Ciphers
AES-256K         8 words into 60 words          -          -           41              -
AES-128        2 column over two cycles    10 rounds      16         30/30           6.36
AES-192        2 column over two cycles    12 rounds      16         36/36           5.28
AES-256        2 column over two cycles    14 rounds      16         42/42           4.56
SHA-1               2 cycles per step       80 steps      64        160/160          4.80
SHA-256             2 cycles per step       64 steps      64        128/128          6.00
MD5                 2 cycles per step       64 steps      64        128/128          6.00
CRC32c              32 bits per cycle           1          4            1           48.00




                     Wire Speed for UltraSPARC T2 Plus is around 5 GB/S
             16,000 new SSL sessions/sec using 1024 Asymmetric Key Exchange
 Export restrictions apply to some of the ciphers, requires installation of the Crypto Enabling
                      patch to use. Purchase a CD which contains the patch.
Affects IPsec related ciphers, SSL typeSun Internal and Approved Partners Only
                                        acceleration is unaffected and does not need enabling.             15
FB-DIMM Memory Interface


             Feature        UltraSPARC T1                       UltraSPARC T2          UltraSPARC T2 Plus
     Require Pins                1000                                440                         208
     Available Bandwidth    23GBytes/second                  50Gbytes/second          37.5Gbytes/second/socket
                                                            Up to 64x DIMM slots     Up to 32x DIMM slots/socket
     Memory Capacity       up to 16x DIMM slots
                                                          T5x20 uses 16 DIMM slots   T5x40 uses 8/16 DIMM slots
               Data
     Memory Controllers            4                                  4                           2
     Memory Latency              96ns                               126ns                       126ns
     DIMM speeds                400MHz                             667MHz                      667MHz
     DIMM Power               7watts/DIMM                     12.5Watts/DIMM               12.5Watts/DIMM




●


●                                      Sun Internal and Approved Partners Only                                     16
10/100/1000/10GbE Network Interfaces
    • Uses the Neptune Chip on the Motherboard which provides
      > Two RJ-45 ports dedicated for 10/100/1000
      > Two RJ-45 ports capable of 10/100/1000
         – Fitting a XAUI adapter disables the one of these ports per XAUI
    • Same 10 GbE XAUI cards as T5x20 server
    • 16 Rx and 24 Tx DMA channels for virtualization
         – Integrated NIU in T2 has 16 Tx channels
            Data
               – Raw UDP Tx performance on Neptune > T2 NIU
         – T2 processor network typically outperforms Neptune on most network
           benchmarks
    • Packet classification
      > Rx data can be HW classified at layer 2 ,3 and 4
         – Put into the separate Rx DMA buffers by classification rules
    • Same 'nxge' device driver as T2 NIU.
    • Performance estimates, testing/tuning ongoing
         – 1 port 10GbE TX/RX = 9.3 Gbps with CPUs still 65-75% idle
●
         – 2 port 10GbE TX/RX = 12-19Gbps (better if dedicate RX/TX ports)
●                              Sun Internal and Approved Partners Only          17
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...


                           Sun Internal and Approved Partners Only   18
SPARC Enterprise                                          Compute Density
                                                          • 4RU chassis
    T5440                                                 • 4-sockets – UltraSPARC T2 Plus
Quad Socket US T2 Plus                                         > Up to 32 cores @ 1.2GHz or 1.4Ghz
                                                               > Up to 256 threads
                                                          • Up to 64 FBDIMM slots
                                                               > 512 GB of memory (using 8GB DIMMS)
                                                          Reliable
                                                          • 4 Hot-Plug 2.5” SAS disks (Raid 0,1)
                                                          • DVD-RW
                                                          • 4 x Redundant(2+2), hot-swappable PSUs
●
    Up to 256 threads / 512GB memory                      • 4 x Redundant, hot-swappable Fans
                                                          • 2N PSU Redundancy, 1900 watts typical
    in a robust, redundant chassis                          consumption
●
    Taking CMT to the Mid-Range                           Expandable
                                                          • 4 x Processor+Memory card pairs
●
    LDOMs consolidation dream box                         • 8 x8 PCIe expansion slots (2 x XAUI)
                                                          • 4 Gigabit Ethernet (or up to 2 x 10GbE and
                                                            2 x1GbE)
                                                          • 4 x USB 2.0


                            Sun Internal and Approved Partners Only                                   19
T5440 Standard Configurations (PTO)
 Part Number                                                Description 4RU
                         2 x 1.2GHz, 8 Core CPU, 32GB (16 X 2GB), 2x 146GB SAS 2.5”disks, 4x
      SEVPCJF1Z
                                  1120W PSU, DVD-RW, 2 x Memory Expansion Boards
                         4 x 1.2GHz, 8 Core CPU, 64GB (32 X 2GB), 2x 146GB SAS 2.5”disks, 4x
      SEVPGLF1Z
                                  1120W PSU, DVD-RW, 4 x Memory Expansion Boards
                          4 x 1.4GHz, 8 Core CPU, 128GB (32 X 4GB), 2x 146GB SAS 2.5”disks,
      SEVPHSF1Z
                                 4x 1120W PSU, DVD-RW, 4 x Memory Expansion Boards


           ●
               All configs feature...
               ●
                   4 x 1GbE interface,
               ●
                   1 x DVD-RW slimline drive
               ●
                   8 x PCIe 8 lane slots (2 shared XAUI slots), 2 x16 mechanical
               ●
                   4 x USB 2.0 slots (2 front/2 back)
               ●
                   1 x DB9 Serial port
               ●   4 x Redundant, Hot-plug PSUs
               ●
                   4 x Redundant, hot-plug fans
               ●
                   2 x 146GB 2.5” SAS drives (can accommodate up to 4 drives)
               ●
                   RAID 0,1 from onboard LSI 1068E controller
               ●
                   1 Year On-Site Warranty
               ●   Rack mount kit with cable management arm
               ●
                   4 x Power Supply cables (country specific)

                                  Sun Internal and Approved Partners Only                      20
Sun Fire T5240/T5440 Differences

         Feature      SPARC Enterprise T5240                          SPARC Enterprise T5440
  Form Factor                  2U, 28” deep                                   4U, 24.5” deep
                         2x UltraSPARC T2 Plus                       Up to 4 x UltraSPARC T2 Plus
  CPU
                       1.2/1.4 GHz 64-128 threads                     1.2/1.4 GHz 128-256 threads
                          FB-DIMM 128GB MAX                              FB-DIMM, 512GB MAX
  Memory                        32x slots                                       64x Slots
                                4x GbE or                                       4x GbE or
  Network                3 x GbE + 1 x 10GbE or                          3 x GbE + 1 x 10GbE or
                           2 x GbE + 2 x 10GbE                             2 x GbE + 2 x 10GbE
  Internal Storage    Up to 16 x 2.5” SAS, hot-swap                  Up to 4 x 2.5” SAS, hot-swap
  Removable Media             1x DVD-RW                                        1x DVD-RW
  Serial                   1x RS-232, 4x USB                               1x RS-232, 4x USB
  PCI Express slots          6x (low profile)                                8x (low profile)
                      2x 1100W AC/2 x1200Watt DC                              4 x 1120W AC
  Power Supply
                          Redundant/Hot-Swap                              Redundant/Hot-Swap
  Fans                  5x Redundant/Hot-Swap                           4 x Redundant Hot-Swap

                                      Sun Internal and Approved Partners Only                       21
Front Panel
                   Service Required LED
                       Power/OK LED
Locator LED                   Power Button
        /Button
                                 Front Fan Fault LED                        System Label
                                     PSU Fault LED
                                        System Overheat Fault LED

                                                          Serial Number label




                                                                                                               DISK 2

                                                                                                                        DISK 3
                                                                                                      DVD-RW


                                                                                                               DISK 0

                                                                                                                        DISK 1
         Dual USB 2.0 ports
                                                            Sun Internal and Approved Partners Only                              22
Rear Panel
                                                                                                          PCI Card Securing
                                                                                                          Latches (internal)




PSU
Status
LED's
                              PSU 3



                              PSU 2


                              PSU 1
                                                      PCI 0
                                                              PCI 1

                                                                         PCI 2
                                                                                 PCI 3
                                                                                         PCI 4




                                                                                                                                             PCI 5
                                                                                                                                                      PCI 6

                                                                                                                                                                PCI 7
                                                      PCI 0


                                                                         PCI 2
                                                                                 PCI 3




                                                                                                                                             PCI 5
                                                                                                                                                      PCI 6

                                                                                                                                                                PCI 7
                              PSU 0


PCI 0    =   PCIe x8, mechanical x8                                                                                                  Quad Gigabit
PCI 1    =   PCIe x8, mechanical x16                                                              SP                                 Ethernet Ports
                                                                                                 Serial
PCI 2    =   PCIe x8, mechanical x8                                                               Port                    SP                                  NET 2     NET 3
                                                                                                                        Network
PCI 3    =   PCIe x8, mechanical x8                                       POSIX DB-9                  Chassis            Port
                                                                           Serial Port              Status LED's                   Dual
PCI 4    =   PCIe x8, mechanical x8, or XAUI 0 Card                                              and Locator Button               USB 2.0                     NET 0     NET 1
                                                                                                                                   Ports
PCI 5    =   PCIe x8, mechanical x8, or XAUI 1 Card
                                                                                                                                                              XAUI 1    XAUI 0
PCI 6    =   PCIe x8, mechanical x16
PCI 7    =   PCIe x8, mechanical x8
                                                                      Sun Internal and Approved Partners Only                                                                    23
Sun Fire T5440 Block Diagram         Mem                    CPU                 CPU                Mem                Mem                   CPU                CPU                Mem              CPU Module =
                                               Module                 Module              Module             Module             Module                Module             Module             Module            - 1 x VF CPU
                                                 0                      0                   2                  2                  1                     1                  3                  3               - 4 x FB-DIMM Slots
                                                                                                                                                                                                              Mem Module =
                                                                                                                                                                                                              - 12 x FB-DIMM Slots




                                                                    Plus




                                                                                        Plus




                                                                                                                                                     Plus




                                                                                                                                                                       Plus
                                                                     T2




                                                                                         T2




                                                                                                                                                      T2




                                                                                                                                                                        T2
           x4
                                  VRM




                                                          VRM




                                                                                 VRM




                                                                                                    VRM




                                                                                                                        VRM




                                                                                                                                             VRM




                                                                                                                                                                 VRM




                                                                                                                                                                                  VRM
           SAS

      LSI1068e
       x8 SAS
                                          4x FB Links         SSI                 SSI               4x FB Links                4x FB Links     SSI               SSI              4x FB Links
                                             PCIe x8                                                                                                                              PCIe x8
                                                                           PCIe x8                  CL0                              CL0                    PCIe x8
                                                                                                               US T2 XBR LPC
                                                                           CL0                                     0                                            CL0
                        x8                                                                          CL1                              CL1                                           x8                         x8
      PLX3                         PLX2                 x8                                                     US T2 XBR LPC                                                                    PLX1                     PLX0
     PEX8548                      PEX8548                                  CL1                                                                                  CL1                         PEX8548                     PEX8548
                                                                                                                   1
x8                                                 x1                                                                                                                             x8
                                                                                                    CL2                              CL2
                        x8         x8                                                                          US T2 XBR
                                                                                                                Zambezi                                                                         x8       x8
      x8                                                                   CL2                                     2     LPC                                    CL2                                                    x8       x8
                                                 PCIe-PCI
               x8                                                                                   CL3                              CL3                                                                       XAUI 1
                                 XAUI 0                                                                        US T2 XBR LPC                                                            Neptune
                                                                           CL3                                     3                                            CL3
                                                       USB
                                                       host

                                        x8
                                                                                                                                                                                        QUAD GbE
                                                                                 USB Hub           USB-IDE            4x SSI                                                              PHY
                                                                                                                      LPC              FPGA                      ILOM                   BCM5466R
                                                                                                                                                       PCI        Card

                                                                BACK                                          FRONT                  BACK                                          0        1        2   3
                                                                panel                                         panel                  panel
                                                                                                                                                            NET SER DB-9
     0     1        2        3     4             USB 2.0                          USB 2.0           DVD
                                                                                                   Sun Internal and Approved Partners Only                  MGT MGT                Quad 10/100/1000                5        6        7
                                                                                                                                                                                                                                     24
Internal View with Cards installed(T5440)                                               System Configuration
  4 Fans are required
                                                                                              Card (SCC)EEPROM




                                                 MEM 3                                                               PCIe 7 x8(m)/x8(e)
                                                                                                                     PCIe 6 x16(m)/x8(e)
                        MB/FT0


                                 MB/FT2
                                 MB/FT2          CPU 3                                                               XAUI/PCIe 5
                                                                                                                     x8(m)/x8(e)

                                                 CPU 1

                                                 MEM 1                                                               Service Processor
                                                                                                                      Daughter Card

                                                 MEM 2
                                                                                                                     XAUI/PCIe 4
                                                                                                                     x8(m)/x8(e)
                                                 CPU 2
                                 MB/FT3
                        MB/FT1


                                 MB/FT3




                                                                                                                     PCIe 3 x8(m)/x8(e)
                                                                                                                     PCIe 2 x8(m)/x8(e)

                                                 CPU 0                                                               PCIe 1 x16(m)/x8(e)
                                                                                                                     PCIe 0 x8(m)/x8(e)

                                                 MEM 0
  4 x SAS
Disk Chassis
                                             Power
                                          Distribution                                     Power
                          Disk               Board
                         Chassis                                                          Supplies



                                           Power BUS Bars
                                           RED = +12Volts
                                           BLUE = Ground
                                                                Chassis Intrusion Switch
                                                            Extension to top cover from MBD
                                               Sun Internal and Approved Partners Only                                              25
Internal View, cards removed(T5440)                                           System Configuration
                      US T2 Plus XBR Coherency Plane Chips                    Card (SCC)EEPROM




                                                                                                     PCIe 7 x8(m)/x8(e)
                                          MEM 3
                                                                                                     PCIe 6 x16(m)/x8(e)
    MB/FT0


             MB/FT2
             MB/FT2                       CPU 3                                                      XAUI 1/PCIe 5
                                                                                                      x8(m)/x8(e)

                                          CPU 1

                                          MEM 1                                                      Service Processor
                                                                                                      Daughter Card

                                          MEM 2
                                                                                                     XAUI 0/PCIe 4
                                                                                                      x8(m)/x8(e)
                                          CPU 2
             MB/FT3
    MB/FT1


             MB/FT3




                                                                                                     PCIe 3 x8(m)/x8(e)
                                                                                                     PCIe 2 x8(m)/x8(e)
                                          CPU 0                                                      PCIe 1 x16(m)/x8(e)
                                                                                                     PCIe 0 x8(m)/x8(e)
                                          MEM 0

                              Power
                           Distribution                                      Power
      Disk                    Board
     Chassis                                                                Supplies




                                               Chassis SeperatorFence

                                  Sun Internal and Approved Partners Only                                            26
Internal View, Motherboard only(T5440)                                                 Neptune Quad
                                DC-DC Converter Modules                                    GbE/10GbE NIC


                                                MEM 3

                                               CPU 3
          MB/FT0



                       MB/FT2
                       MB/FT2




                                                                                                             Quad GbE RJ-45
                                                                                                                  Ports
                                               CPU 1
                                                                                                              NET MGT port
                                                                                                             Dual USB 2.0 Port

                                               MEM 1                                                         System Status LEDs

                                                                                                             SER MGT port

                                               MEM 2                                                         DB-9 Serial Port


                                               CPU 2                                                         Service Processor
                                                                                                              Card Connector
                       MB/FT3
          MB/FT1




                                               CPU 0

                                               MEM 0


                                                                   PLX PCIe Switch
                                                                        Chips
                                                                                            'Southbridge'
                                                                                           Peripheral Chip
Fan connectors, with                                   LSI1068E Disk Controller
 speed control logic
                                                 Sun Internal and Approved Partners Only                                        27
Motherboard and CPU/MEM Card layout
                                  MEM 3

                                  CPU 3

                                  CPU 1

                                  MEM 1

                                  MEM 2

                                  CPU 2

                                  CPU 0

                                  MEM 0

                             Motherboard




       CPU/Mem Board                                             Memory Board




                       Sun Internal and Approved Partners Only                  28
Memory Configuration Rules
• 1 or 4 CPU cards in a system
    > Each CPU card has an associated
      Memory Card                                                                            Card/Chassis
    > Unpopulated Cards must be filled                                                       Top
      with spacers
    > Unpopulated DIMMs must be filled                                UltraSPARC T2
                                                                            Plus
      with spacers                                                                     VRM
                                                                          CPU
• All DIMMS on a CPU & Memory                            VRM


  card pair must be the same size                                BR1/CH0/DO
                                                                 BR1/CH1/DO                                      BANK 0
  > 2GB, 4GB or 8GB only (no                                     BR0/CH0/DO
                                                                                              VRM           Install ALL DIMMs

      1GB)                                                       BR0/CH1/DO


  > May support Different DIMM
      sizes on different pairs...                                BR1/CH1/D2
                                                                 BR1/CH1/D3                                      BANK 3

• 3 Configs...                                                   BR1/CH0/D2
                                                                 BR1/CH0/D3
                                                                                                            Install ALL DIMMs


  > Fill Bank 0                                                           BR0/CH1/D2
                                                                                                                 BANK 2
  > Fill Banks 0,1                             VRM                        BR0/CH1/D3
                                                                                                            Install ALL DIMMs
                                                                          BR0/CH0/D2

  > Fill Banks 0,1,2,3                                                    BR0/CH0/D3
                                                                          BR0/CH1/D1
                                               VRM                        BR0/CH0/D1                             BANK 1

• All standard configs provide
                                                                                                            Install ALL DIMMs
                                                                          BR1/CH1/D1
                                                                          BR1/CH0/D1
  exactly 8 free DIMM slots
  simultaneously                  Sun Internal and Approved Partners Only                                                   29
Network Ports and Options




                                                       XAUI 0




                                                                                                          XAUI 1
   Device         NET 0           NET 1           NET 2           NET 3           XAUI 0          XAUI 1
   Driver         nxge0           nxge1           nxge2           nxge3           nxge0*          nxge1*
   PCI Device PCI@500/0/c/0,0 PCI@500/0/c/0,1 PCI@500/0/c/0,2 PCI@500/0/c/0,3 PCI@500/0/c/0,0 PCI@500/0/c/0,1



                                              NOTES
               All Ethernet ports provided by a single Neptune Chip on the motherboard                             NET 2   NET 3
NET 0 and NET 1 are disabled by XAUI 1 and XAUI0,if installed, to take advantage of 10GbE networking
          * If a XAUI card is installed, the matching RJ-45 port is disabled (NET 0 and NET 1)
                    XAUI cards take one of three current Fibre 10GbE transceivers
                    Short Reach(SR), Long Reach(LR) and Long Reach Multimode(LRM)                                  NET 0   NET 1
                       Copper versions of the XAUI card are expected Post-RR
 XAUI Cards consume the same physical space in the chassis as a PCI card, so are mutually exclusive
                              with PCI cards in the same location


                                                                Sun Internal and Approved Partners Only                            30
10GbE XAUI Option Cards
•   Interface to the Neptune chip to upgrade two of its ports to 1GbE
•   Cards each consume a PCI-E slot if installed
•   Attach to dedicated XAUI sockets on special risers
•   10Gbe XAUI Card
               – SESY7XA1Z
     > Requires Fibre Tranceivers
         – 10GbE Short Reach(SR)
               – SESY7XT1Z
         – 10GbE Long Reach (LR)
               – SESY7XT2Z
         – 10GbE Long Reach multimode (LRM)
               – part No. TBD

• Copper connector XAUI versions to follow post-RR


                                 Sun Internal and Approved Partners Only   31
PCIe Slots
Built In

• No Riser Cards are used, slots are directly on the motherboard
• Low Profile PCI-Express cards only
• Each Slot is capable of 25Watts power
• Total power capacity limited to 140Watts
  > Systems design point was to accommodate 8 x 17.5Watt Atlas(Quad GbE using
     Neptune) card
• Each Slot has x8 PCIe electrical capability and at least x8 mechanical connectors
• Slots 1 and 6 have x16 mechanical connectors
• XAUI cards in slots 4 and 5 replace PCIe cards in those slots




                                  Sun Internal and Approved Partners Only             32
PCIe External IO Expansion Unit
  aka Expansion Chassis, I/O Box
• Up to 2 x PCI Expansion Chassis are supported
  > P/N : SENX8BE1Z
  > 4RU, 19” rack compatible , 28” deep
  > 1 Host card supported per US T2 Plus
  > Each chassis is managed by host SP
• Only support PCIe card IO boats ( PCI-X ?)
  > Each 'boat' requires an Link Card in the host
     (ensign) and a link Card in the boat (captain)
     with special card between them
  > IO 'boat' supports 6 x PCIe x8 full-length, hot-
     pluggable PCIe cards
• Chassis default configs contain
  > 2 x Hot-plug redundant 600Watt PSU/FAN
     FRU's
  > 1 x PCIe 'boat', 1 link card pair(host-chassis)
     and cable
  > 6 x PCIe card carriers for x8 PCIe Cards
  > Customers can add a further PCIe 'boat'
      – P/N : SENX8TE1Z and more
                                      Sun Internal and Approved Partners Only   33
Disk Drives
• Disk drives are all 2.5” form factor
• Original Galaxy NEMO bracket (not Marlin Bracket)
• Support SAS only (Can mix SAS/SATA after qual)
• SAS Drives
      – 73GB @ 10K RPM
      – 146GB @ 10K RPM
      – 73GB @ 15K RPM
      – SSD (post-RR)
• Same disks as T2x00 systems

                                                                                   Disk LED's
                                                                                     Ready to Remove
                                                                                     Fault
                                                                                     Status




                                         Sun Internal and Approved Partners Only                 34
Disk Controller Options
• T5440 has embedded LSI 1068E on the motherboard
      – JBOD up to 4 disks
      – Controls internal disks only
      – Unused 4 ports are not used
      – RAID 0 (striping) and RAID 1(mirroring)
      – Hot-plug supported
      – Hot-swap in non-RAID configs is done with 'cfgadm'
• SGXPCIESAS-R-INT-Z NOT supported
  > Not available for T5440 due to chassis design and only 4 disk capacity
• SGXPCIESAS-R-EXT-Z Supported
     – For external disk arrays only (no internal ports)
     – 8 port SAS RAID 0,1,1E,5,5EE,6,10,50,60 (depending on number of disks available)
     – Adaptec Card and Firmware with Intel SunRiseLake chipset
     – Battery Backed Write Cache (BBWC) of 256MB, at least 72 hours capacity, much
       longer when new
                                    Sun Internal and Approved Partners Only               35
Fans and Cooling
• Front to Back cooling
• Two rows of fans provide redundancy
  > PSU fans provide sufficient redundancy
     for Disk cooling                                           Back                                                  Front


• Requires 4 Fans




                                                                                                            Disks
                                                                                 PSU's
      – Main System Cooling
                                                                                            MEM0
             – MB/FT0




                                                                                                             MB/FT2
                                                                                                   MB/FT3
                                                                                                   MB/FT3
                                                                                            CPU0
             – MB/FT1                                                                       CPU2
                                                                              Motherboard   MEM2
             – MB/FT2                                                                       MEM1




                                                                                                   MB/FT1


                                                                                                             MB/FT0
                                                                                                   MB/FT1
             – MB/FT3                                                                       CPU1
                                                                                            CPU3
      – PSU integrated Fan Cooling flow                                                     MEM3
             – Cools disk drives and PSU's
             – PSUFAN0
             – PSUFAN1
             – PSUFAN2
             – PSUFAN3



                                    Sun Internal and Approved Partners Only                                                   36
Fans modules and boards
                                                                                  Fan Fault
                                                                                 Amber LED
                                                                                Lit if fan faulty



• 4 Fans Required
  > 60 Seconds grace if FAN removed for service
• Fans are speed controlled by the Service Processor
• Speeds are independantly monitored by SP
• Speeds tuned to minimise vibrations
  > Built in vibration sensor
• Speeds chosen to minimise harmonic resonance
  with disk drives and other fans.
• Each fan has an Amber FAULT LED
      – if lit the fan module is faulty




                                      Sun Internal and Approved Partners Only                       37
Power Supplies
• PSU's are high efficiency
• Output 12V (and 3.3v standby)
                                                                       PSU Fault
• Most DC-DC conversion done in MBD                                      LED

• Integrated Fans
• 4 PSU's
  > 2 + 2 Redundancy (Grid Redundancy)
  > Rated at 1120Watts each.




  > BEWARE...
      – Same form factor as SunFire X4600 PSU's ... DO NOT MIX
                             Sun Internal and Approved Partners Only               38
Rack Mounting Options
• Two Rack mounting options are available..
• Standard Rack Mount (4 post)
  > P/N : SEVY9RK1Z
  > Same as Sun Fire X4600 server
  > Standard configs contain this kit
• Tool-less Rack Kit (4 post)
  >   P/N : SEVY9RK2Z
  >   Optional kit, purchased seperately
  >   Snaps into Sun and most 3rd party Racks
  >   Requires no tools to fit or remove
  >   Will replace tool-required version once available
                            Sun Internal and Approved Partners Only   39
Solaris for Sun SPARC Enterprise T5x40
• T5x40 servers will require Solaris10 5/08 (update 5) with
  patches
  > A Patch CD is supplied in the box
     – Likely to be out of date, so customers should check SunSolve...
• This incorporates several specific UltraSPARC T2/T2 Plus
  optimizations and for CMT servers in general
• Also includes some specific T5x40 optimisations
  >   UltraSPARC T2 Plus MPO optimisations
  >   nxge driver tweaks for 10GbE devices
  >   MMU DMA relaxed scheduling
  >   LDOMs pre-install upgrade to version 1.0.3 (US T2 Plus support)


                              Sun Internal and Approved Partners Only    40
Solaris FMA
• Now aware of CPU Core offlining
• PCIe Fabric diagnostics improved
• Crypto Unit offlining
• Neptune awareness (though XAUI's not diagnosed)
• POST memory CE tolerance improved
• FRU identity info improved in fault reports (part/ser #)
• Diagnostic Engines (DE)
       – Existing DE have been extended for T5x40
       – New Eversholt DE used for HostBridge, PCIe diagnostics
• Limitations...
             –   Can't isolate Uncorrectable Errors to a single DIMM
             –   PCIe riser cards not in topology
             –   XAUI card and XFP not in the topology
             –   SouthBridge chip is not diagnosed at this time (DVD, USB,...)
             –   IO Expansion box is not diagnosed via FMA
                                     Sun Internal and Approved Partners Only     41
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > System Architecture and Tours
   > Extra Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 3.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...


                           Sun Internal and Approved Partners Only   42
ILOM Features at a Glance
•   Hardware Control, Inventory, Monitoring
•   Host Configuration and Administration
•   SP Configuration and Administration
•   Logging, Auditing and Alerting
•   Authentication :
       – LDAP, RADIUS, Active Directory, Local Users
• Services :
       – SSH, HTTP(S), NTP, Syslog, SMTP
• Out-of-Band
       – Via Serial port, or dedicated Ethernet port
• In-Band
       – Via Host OS, firmware upload, Explorer, Syslog

                                   Sun Internal and Approved Partners Only   43
ILOM – Industry Standard Manageability
 • ILOM enables Sun systems to be easily integrated into third
   party management infrastructures
 • Key functionality
   >   IPMI 2.0
   >   SNMP V1, V2c, V3
   >   SSH 2.0
   >   LDAP, RADIUS & MS Active Directory authentication
   >   Browser UI, SMASH DMTF CLP + ALOM style CLI
 • NOTE : No RKVMS functionality like Galaxy ILOM
    > No Java plugin required
 • Browsers tested include, these base versions an later
   releases
       – Mozilla 1.7 on Solaris 10, IE 6.0 on W2K Server, Firefox
         1.0 and 1.5 on W2K server
                               Sun Internal and Approved Partners Only   44
ILOM – Industry Standard Manageability

 • Identical to ILOM 2.0 for T5x20
 • Default user is 'root' with password 'changeme'
    > Use for ILOM WEB GUI access and SSH access and IPMI
 • The ALOM 'admin' user is not defined by default, create this
   user with an ALOM CLI
 • Lost 'root' password and ILOM config is reset using jumpers
    > T5140/T5240 - Motherboard Jumper J10401 (short pins 1-2)
    > T5440 - SP Daughter card Jumper J1127 (short pins 1-2)
 • Note... 'sunservice' user shares the password of the 'root'
   user           ONLY FOR SERVICE ACCESS*
 • Passwords must be 8 to 16 chars (used to be max 8)
 • Max of 10 users allowed (used to be 16)
                           Sun Internal and Approved Partners Only   45
ILOM Common Tasks
• Setting up an ALOM 'admin' user from the ILOM CLI
  >   SUNSP00144F4641BD login: root
      Password: changeme
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      Warning: password is set to factory default.
      ->create /SP/users/admin role=Administrator cli_mode=alom
      Creating user...
      Enter new password: ********
      Enter new password again: ********
      Created /SP/users/admin2
      -> exit
      SUNSP00144F4641BD login: admin
      Password: ********
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      sc>



                                         Sun Internal and Approved Partners Only   46
ILOM Common Tasks
• Setting up ILOM IP configuration from the ILOM CLI
  >   SUNSP00144F4641BD login: root
      Password: changeme
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      Warning: password is set to factory default.
      -> set /SP/network state=enabled
      Set ’state’ to ’enabled’
      -> set /SP/network pendingipaddress=10.8.31.163
      Set ’pendingipaddress’ to ’10.8.31.163’
      -> set /SP/network pendingipdiscovery=static
      Set ’pendingipdiscovery’ to ’static’
      -> set /SP/network pendingipnetmask=255.255.252.0
      Set ’pendingipnetmask’ to ’255.255.252.0’                                      Static IP
      -> set /SP/network pendingipgateway=10.8.31.248                              configuration
      Set ’pendingipgateway’ to ’10.8.31.248’
      -> set /SP/network commitpending=true
      Set ’commitpending’ to ’true’
      ->

      -> set/SP/pendingipdiscovery=dhcp
      Set ’pendingipdiscovery’ to ’dhcp’
      -> set /SP/network commitpending=true
      Set ’commitpending’ to ’true’
      ->                                                                           Dynamic IP
                                                                                     (DHCP)
                                                                                   configuration



                                         Sun Internal and Approved Partners Only                   47
ILOM IPMI functionality
• IPMI is a widely used management protocol for x86 servers
• ... But its new for SPARC boxes...
• Download the required tools from
  > The Solaris Supplemental CD (an older binary package)
  > Latest is available at http://ipmitool.sourceforge.net
     – Binary packages (usually older versions) are available for Solaris x86 and SPARC, as
       well as Linux, Windows, Mac...etc
  > There is a Blueprint available from Sun also (mainly x64 centric, but applies to SPARC
    now too)
            – http://www.sun.com/blueprints/0107/820-1011.pdf


       -bash-ventus2$ /opt/ipmitool/bin/ipmitool     -U root -P changeme -H 10.10.10.10 sdr
       /MB/V_+1V0_VDD   | 1.01 Volts        | ok
       /MB/V_+3V3_STBY | 3.36 Volts         | ok                                                             Get the Sensor
       /MB/V_+3V3_MAIN | 3.36 Volts         | ok                                                                  Data
       /MB/V_+5V0_VCC   | 4.97 Volts        | ok                                                              Repository
       /MB/V_+12V0_MAIN | 12.16 Volts       | ok
       ..
       ..
       -bash-ventus2$ /opt/ipmitool/bin/ipmitool     -U root -P changeme -H 10.10.10.10 sunoem sbled set
       /SYS/LOCATE on
       /SYS/LOCATE      | ON                                                                               Set the System
       -bash-ventus2$                                                                                       Locator LED
                                                                                                               flashing


                                          Sun Internal and Approved Partners Only                                      48
ILOM Common Tasks
• Logging into the ILOM Web GUI
                                                               •   Point Web Browser at the IP address of
                                                                   the ILOM
                                                                    > Will automatically redirect to a
                                                                        secure HTTPS port
                                                                    > Best to disable any Web Proxies for
                                                                        best performance
                                                                    > Make sure port 80, 443 are open on
                                                                        any firewall
                                                               •   Log in as any defined user, default
                                                                   Administration user is 'root'




                     Sun Internal and Approved Partners Only                                                49
ILOM/ALOM Common Tasks
• A Tour of the ILOM Web GUI                                   •   GUI provides ways to set up IP address
                                                                   configurations for ILOM
                                                               •   Configure additional ILOM/ALOM users
                                                               •   Access Sensor Readings
                                                               •   Control System configurations
                                                               •   Carry out firmware updates.
                                                               •   etc....




                     Sun Internal and Approved Partners Only                                                50
ALOM 2.0 vs. 1.4 CLI Differences
• Default CLI appearance is ILOM
      – User is 'root'
      – Must create an 'admin' Administrator user with the ALOM CLI
• Flashupdate in new ALOM expects a TFTP server not an FTP server
• ALOM IP address changes now active only after running ...
      – 'setsc netsc_commit true'
      – Previously changes were active only after SC reset
      – DHCP is enabled by default
• View firmware versions with
      – 'showhost version'                              sc> showhost version
                                                         Sun System Firmware 7.0.0_build_13 2007/08/10 23:44



• Only Admin and Operator roles
                                                        Host flash versions:
                                                           Hypervisor 1.5.0.build_13**PROTOTYPE** 2007/08/10 22:54
                                                           OBP 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:25

  are defined
                                                           Sun Fire[TM] Huron POST 4.27.0.build_04***PROTOTYPE BUILD***
                                                        2007/08/10 13:51




                             Sun Internal and Approved Partners Only                                                      51
ALOM backward Compatibilty CLI
• Uses ALOM-CMT 1.2 for a base feature set
• Includes ALOM-CMT 1.4 features...
  >   break -d
  >   Host Watchdog Timer
  >   Bootmode LDOMs awareness
  >   Forward SP events to Hot/Solaris syslog via inband channel




                           Sun Internal and Approved Partners Only   52
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > Comparison to SunFire T1000/T2000/T5x20
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...

                           Sun Internal and Approved Partners Only   53
Logical Domains 1.0.3 Features

• UltraSPARC T2 Plus Platform Support
  > 128 domains supported at RR
     – 256 domains work on T5440, may be qualified later, requires Solaris fixes
• Feature Set very similar to 1.0.2
• I/O domain can reboot while the other domains keep running
  > Dependent domains would wait for I/O transactions to complete
• LDoms SNMP MIB
  > Modeled after industry standard DMTF CIM (Common Information Model)
  > Running on control domain to enable remote SNMP monitoring
• Domain minimization support
  > Minimal/reduced Solaris installation
  > Base minimal packages plus optional ones for guest, control, I/O or service
    domains
                              Sun Internal and Approved Partners Only              54
Logical Domains 1.0.3 Requirements
 • Solaris 10 05/08 (update 5) and required patches
 • Systems firmware version
      – T5x40 Firmware 7.1.5b = SP FW 2.0.4.20+
      – T5x20/SB6320 Firmware 7.0.4+ = SP FW 2.0.4.0+
      – T2000/T1000/T6300/Pelton Firmware 6.5.x
 • SUNWldm.v LDOMs Manager Package
      – Version 1.0.3




                           Sun Internal and Approved Partners Only   55
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > Comparison to SunFire T1000/T2000/T5x20
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...

                           Sun Internal and Approved Partners Only   56
Option Parts List for T5440(ATO)

  Part Number   Option Description                                                  Available
   SEVY1CB1Z    T2 Plus CPU module, 8 core, 1.2GHz, 8GB(4x2GB) with memory board    RR
   SEVY1CC1Z    T2 Plus CPU module, 8 core, 1.2GHz, 16GB(4x4GB) with memory board   RR
   SEVY1CD1Z    T2 Plus CPU module, 8 core, 1.2GHz, 32GB(4x8GB) with memory board
   SEVY1DD1Z    T2 Plus CPU module, 8 core, 1.4GHz, 32GB(4x8GB) with memory board
   SEVY1DB1Z    T2 Plus CPU module, 8 core, 1.4GHz, 8GB(4x2GB) with memory board    Subject to 1.4GHz availability
   SEVY1DC1Z    T2 Plus CPU module, 8 core, 1.4GHz, 16GB(4x4GB) with memory board   Subject to 1.4GHz availability
   SESY2A1Z     2GB Memory Expansion kit(2x1GB)
   SESY2B2Z     4GB Memory Expansion kit(2x2GB)                                     Non-Extended ECC version, no mixing
   SESY2D1Z     16GB Memory Expansion kit (2 X8 GB)
   SESY2C1Z     8GB Memory Expansion kit(2x4GB)
   SESVY3A11Z   73GB 10Krpm, 2.5” SAS Drive
   SESVY3C11Z   146GB 10Krpm, 2.5” SAS Drive
   SESVY3A21Z   73GB 15Krpm, 2.5” SAS Drive
   SEVY9PS51Z   1120W AC Power Supply
   SEVY9DV1Z    DVD, 8x DVD-RW Slimline module
   SEVY9RK1Z    Slide Rail Kit, Screw Mounting
   SEVY9RK2Z    Slide Rail Kit, Toolless Mounting




                                        Sun Internal and Approved Partners Only                                           57
Option Parts List for T5440 (cont..)
         Part Number                              Option Description                             Avialable   Max number
SG-XPCIE1FC-QF4                             Qlogic, 4Gb, PCI-E Single Port                          RR            8
SG-XPCIE2FC-QF4                             Qlogic, 4Gb, PCI-E Dual Port                            RR            8
SG-XPCIE1FC-EM4                           Emulex, 4Gb, PCI-E Single Port                            RR            8
SG-XPCIE2FC-EM4                             Emulex, 4Gb, PCI-E Dual Port                            RR            8
SG-XPCIE2SCSI-U320Z                          U320 SCSI, PCI-E Dual Port                             RR            8
SG-XPCIE8SAS-E-Z                                  SAS, 8 Port, PCI-E                                RR            8
SGXCPCIESAS-R-EXT-Z                    SAS, 8 Port External RAID Controller                         RR            2
X7281A-2                          Northstar Dual port GigE MMF Low profile PCI-E                    RR            8
X7280A-2                          Northstar Dual port GigE UTP Low profile PCI-E                    RR            8
X1236A-Z                                Infiniband HBA, Dual 4x ports, PCI-E                        RR            8
X4447A-Z                          Atlas Quad Port, GigE Copper, PCI-E (up to 3/6)                   RR            8
X1027A-Z                                    Atlas Dual Port, 10GigE, PCI-E                          RR            4
X5558A                                 Tranceiver 10GE SR XFP (XAUI/Atlas)                          RR            -
X5560A-Z                               Tranceiver 10GE LR XFP (XAUI/Atlas)                          RR            -

X3000A-Z                             XVR-300, PCI-E x8 Graphics cards (up to 1)                     RR           4
SESY7XA1Z                                        10GbE XAUI card                                    RR           2
TBD                                       10GbE XAUI Copper 10g Base-T                             TBD           2
X6000A                                      Sun Crypto Accelerator 6000                             RR           2

SENY8BE1Z                         External IO Expansion Unit – PCI-E base Config                    RR           2
SENY8TE1Z              PCI-Express “boat” for External IO Expansion Unit (6 Hot Plug carriers)      RR           4
SELY8LK1Z                           Copper link kit for IO Expansion unit “boat”                    RR           4




                                                Sun Internal and Approved Partners Only                                   58
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > Comparison to SunFire T1000/T2000/T5x20
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...

                           Sun Internal and Approved Partners Only   59
Tuning Out of the Box
• Using Solaris 10 05/08 (update 5) with Patches
  > MPO optimisations used
  > DMA relaxed Ordering implemented
  > Default pages sizes for
         –   Initdata Segments is 64kB pages
         –   Private Anon, Heap, Process Stack, Text, Shared Anon segments are 4MB pages
         –   ISM and DISM use 256MB pages
         –   New variables introduced to control these sizes if changes are needed
                – max_uheap_lpsize,max_ustack_lpsize, max_privmap_lpsize,
                  max_shm_lpsize, max_uidata_lpsize, max_utext_lpsize, max_shm_lpsize
  > L2 Cache hashing implemented
         –   helps randomise accesses to L2 caches and ease thrashing
  > Stack biasing implemented
         –   D-Cache is only 4 Way associative... 8 threads
         –   Running multiple copies of a binary can lead process stacks aligning in the cache
             and to hot lines in the cache
         –   Stack Bias slews the stack variable for processes.
                                 Sun Internal and Approved Partners Only                         60
Tuning Out of the Box (continued..)
  > Processor Groups introduced
     – Helps associate CPUs with some shared resources (int/FP pipelines,
       Crypto units etc)
     – Enables improved multi-level CMT load balancing and affinity policies
  > 'bcopy'/'uiomove' Optimizations
           –   Key kernel operations
           –   new implementation about 2x faster than previous

• Optimisations will require patching of S10 05/08
  >   These will be post RR patches as they become available
  >   Most fixes are already committed in update 5
  >   Check patch levels for customers with performance issues
  >   Also check Firmware versions as this can improve performance
      too...

                                   Sun Internal and Approved Partners Only     61
Tuning Recommendations
• Less involved than with T2000
• S10 5/08 is more 'automatic'
        – OOB optimised page size selection, thread scheduling, block copy, IP instances for
          zones, page coloring etc...
• If tuning is necessary remember...
   >   Improved pipeline results in Single threaded performance around 20% better
   >   Floating Point is no longer an issue
   >   Start with T2000 tuning options
   >   Use updated trapstat, cpustat,
• LDOMs may be an easier way to scale poorly threaded applications
• Solaris Crypto framework is still being tuned
   > Great for big packets, working on improving small packets

• A Blueprint is being prepared (Denis Sheahan)



                                     Sun Internal and Approved Partners Only                   62
Tuning Recommendations (cont..)
• Refer to UltraSPARC T1 applications tuning best practices...
  > http://www.sun.com/servers/coolthreads/tnb/applications.jsp
• CoolTools are being updated for UltraSPARC T2 and T2 Plus
  > http://www.sun.com/servers/coolthreads/overview/cooltools.jsp
• Sun Studio 12 is UltraSPARC T1 and T2/T2 Plus aware
  > Recompiling without code changes should benefit T1/T2/T2 Plus apps
• LDOMs configs can benefit significantly from a transition to T5x20 platform
  > Multiple IO/Service domains with higher bandwidth PCI busses
  > Make sure appropriate LDOMs tuning and sizing is carried out
• Wider Crypto capability, so ensure code is using PKCS#11 framework
  > Ensure that the ncp (SSL, RSA, DSA etc) and n2cp (bulk ciphers),
     n2rng(random number generator) drivers are used appropriately


                               Sun Internal and Approved Partners Only          63
PCIe Performance
• Easily two to four times the performance of T5x20 (two or
  four PCIe Busses)
• All PCI card slots are x8 PCI electrically
  > Single level hierarchy
  > Cut through switching
  > PCI-E relaxed ordering for higher performance
• Performance per bus...
  > Marketing performance =              4000MB/sec
  > Theoretical Rate with overheads =    3790MB/sec
  > Max. DMA Achievable(bidirectional) = 3096MB/sec
     – with 128byte packets
     – And 512 byte read size
                         Sun Internal and Approved Partners Only   64
Agenda
• Introduction
• Comparision of the UltraSPARC T2 to UltraSPARC VF
• Sun SPARC Enterprise T5x40 servers
   > Overview of Features
   > System Architecture and Tours
   > Memory, Networking and IO Expansion
   > Disks, Fans and Power Supplies
   > Solaris for T5x40
• ILOM 2.0
• LDOMs for T5x40
• CRUs/FRUs and Configuration Options
• Tuning and Performance
• Tools, Information and References
• Q & A ...


                           Sun Internal and Approved Partners Only   65
Tools and Information
• Cool Tools
    – http://www.sun.com/servers/coolthreads/overview/cooltools.jsp
• SUNWIN Tokens
  > Sun SPARC Enterprise T5440
     – Architecture Whitepaper                                          : 526122
     – JTF                                                              : 526118
  > T5440 RAS Whitepaper                                                : TBA
• Video Tours
  > Check the Sun.com product pages
• Power Calculators
  > Check the Sun.com product pages

                              Sun Internal and Approved Partners Only              66
Further Information
• Presto
  > T5440
  > http://sunwebcollab.east.sun.com/gm/document-1.26.680780/Batoka_PRESTO.html

• Installed Business Base (IBB) Promotions
  > http://sunwebcollab.east.sun.com/gm/document-1.26.680782/Batoka_IBB_Promo.html

• Start Up Essentials program
  > http://sunwebcollab.east.sun.com/gm/document-1.26.680794/Maramba_Batoka_SU_April1.html




                                   Sun Internal and Approved Partners Only               67
Reference Information
• T5440 Engineering TOI
     – http://ittdev.east.sun.com/TechTalk2/EngineeringTOIs/
• ILOM/ALOM User Guides
      – http://www.sun.com/products-n-solutions/hardware/docs/pdf/819-1160-13.pdf
      – http://www.sun.com/products-n-solutions/hardware/docs/pdf/819-7981-10.pdf
• Solaris FMA
      – http://fma.eng
      – http://lightside.sfbay/n2-fma/docs.php
•




                                    Sun Internal and Approved Partners Only         68
Thank You
Sun Microsystems



                   69
T5x40 PCI Topology




              Sun Internal and Approved Partners Only   70
10GbE Networking Substantiation
10GbE price for 2 x SR-fiber PCI-E adaptors = $6,740. From HP DL380G5 pricing on HP Store, www.hp.com, 12/17/07. Cost for 2 x 10GbE
and SR transceivers for Maramba and Batoka are $1,800. From sun.com, 12/17/07




                                                     Sun Internal and Approved Partners Only                                          71

Weitere ähnliche Inhalte

Was ist angesagt?

TiDBのトランザクション
TiDBのトランザクションTiDBのトランザクション
TiDBのトランザクションAkio Mitobe
 
Oracle RAC Internals - The Cache Fusion Edition
Oracle RAC Internals - The Cache Fusion EditionOracle RAC Internals - The Cache Fusion Edition
Oracle RAC Internals - The Cache Fusion EditionMarkus Michalewicz
 
F5 Solutions for Service Providers
F5 Solutions for Service ProvidersF5 Solutions for Service Providers
F5 Solutions for Service ProvidersBAKOTECH
 
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日IBM Analytics Japan
 
LDAP - Lightweight Directory Access Protocol
LDAP - Lightweight Directory Access ProtocolLDAP - Lightweight Directory Access Protocol
LDAP - Lightweight Directory Access ProtocolS. Hasnain Raza
 
Open Liberty / WebSphere Liberty
Open Liberty / WebSphere LibertyOpen Liberty / WebSphere Liberty
Open Liberty / WebSphere LibertyTakakiyo Tanaka
 
CCNA 1 Routing and Switching v5.0 Chapter 9
CCNA 1 Routing and Switching v5.0 Chapter 9CCNA 1 Routing and Switching v5.0 Chapter 9
CCNA 1 Routing and Switching v5.0 Chapter 9Nil Menon
 
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.NAVER D2
 
New Generation Oracle RAC Performance
New Generation Oracle RAC PerformanceNew Generation Oracle RAC Performance
New Generation Oracle RAC PerformanceAnil Nair
 
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018Toru Makabe
 
Comment hacker Active Directory de A à Z? - Par Sylvain Cortès
Comment hacker Active Directory de A à Z? - Par Sylvain CortèsComment hacker Active Directory de A à Z? - Par Sylvain Cortès
Comment hacker Active Directory de A à Z? - Par Sylvain CortèsIdentity Days
 
High availability deep dive high-end srx series
High availability deep dive high-end srx seriesHigh availability deep dive high-end srx series
High availability deep dive high-end srx seriesMuhammad Denis Iqbal
 
Disaggregating Ceph using NVMeoF
Disaggregating Ceph using NVMeoFDisaggregating Ceph using NVMeoF
Disaggregating Ceph using NVMeoFShapeBlue
 
Database Security for PCI DSS
Database Security for PCI DSSDatabase Security for PCI DSS
Database Security for PCI DSSOhyama Masanori
 
Oracle Exadata Management with Oracle Enterprise Manager
Oracle Exadata Management with Oracle Enterprise ManagerOracle Exadata Management with Oracle Enterprise Manager
Oracle Exadata Management with Oracle Enterprise ManagerEnkitec
 
MySQL/MariaDB Proxy Software Test
MySQL/MariaDB Proxy Software TestMySQL/MariaDB Proxy Software Test
MySQL/MariaDB Proxy Software TestI Goo Lee
 

Was ist angesagt? (20)

TiDBのトランザクション
TiDBのトランザクションTiDBのトランザクション
TiDBのトランザクション
 
Oracle RAC Internals - The Cache Fusion Edition
Oracle RAC Internals - The Cache Fusion EditionOracle RAC Internals - The Cache Fusion Edition
Oracle RAC Internals - The Cache Fusion Edition
 
F5 Solutions for Service Providers
F5 Solutions for Service ProvidersF5 Solutions for Service Providers
F5 Solutions for Service Providers
 
LDAP
LDAPLDAP
LDAP
 
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日
Db2 & Db2 Warehouse v11.5.4 最新情報アップデート2020年8月25日
 
VLAN
VLANVLAN
VLAN
 
LDAP - Lightweight Directory Access Protocol
LDAP - Lightweight Directory Access ProtocolLDAP - Lightweight Directory Access Protocol
LDAP - Lightweight Directory Access Protocol
 
Open Liberty / WebSphere Liberty
Open Liberty / WebSphere LibertyOpen Liberty / WebSphere Liberty
Open Liberty / WebSphere Liberty
 
CCNA 1 Routing and Switching v5.0 Chapter 9
CCNA 1 Routing and Switching v5.0 Chapter 9CCNA 1 Routing and Switching v5.0 Chapter 9
CCNA 1 Routing and Switching v5.0 Chapter 9
 
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.
[135] 오픈소스 데이터베이스, 은행 서비스에 첫발을 내밀다.
 
Basics of ssl
Basics of sslBasics of ssl
Basics of ssl
 
New Generation Oracle RAC Performance
New Generation Oracle RAC PerformanceNew Generation Oracle RAC Performance
New Generation Oracle RAC Performance
 
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018
帰ってきた インフラ野郎 Azureチーム ~Azure データセンターテクノロジー解体新書2018春~ - de:code2018
 
Comment hacker Active Directory de A à Z? - Par Sylvain Cortès
Comment hacker Active Directory de A à Z? - Par Sylvain CortèsComment hacker Active Directory de A à Z? - Par Sylvain Cortès
Comment hacker Active Directory de A à Z? - Par Sylvain Cortès
 
High availability deep dive high-end srx series
High availability deep dive high-end srx seriesHigh availability deep dive high-end srx series
High availability deep dive high-end srx series
 
Disaggregating Ceph using NVMeoF
Disaggregating Ceph using NVMeoFDisaggregating Ceph using NVMeoF
Disaggregating Ceph using NVMeoF
 
Database Security for PCI DSS
Database Security for PCI DSSDatabase Security for PCI DSS
Database Security for PCI DSS
 
Oracle Exadata Management with Oracle Enterprise Manager
Oracle Exadata Management with Oracle Enterprise ManagerOracle Exadata Management with Oracle Enterprise Manager
Oracle Exadata Management with Oracle Enterprise Manager
 
MySQL/MariaDB Proxy Software Test
MySQL/MariaDB Proxy Software TestMySQL/MariaDB Proxy Software Test
MySQL/MariaDB Proxy Software Test
 
Bgp tutorial for ISP
Bgp tutorial for ISPBgp tutorial for ISP
Bgp tutorial for ISP
 

Andere mochten auch

Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentationSun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentationxKinAnx
 
Sun fire x4140, x4240, x4440 server customer presentation
Sun fire x4140, x4240, x4440 server customer presentationSun fire x4140, x4240, x4440 server customer presentation
Sun fire x4140, x4240, x4440 server customer presentationxKinAnx
 
Power Searching Google And Google Scholar
Power Searching Google And Google ScholarPower Searching Google And Google Scholar
Power Searching Google And Google ScholarLaura Wilson
 
Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini linkAhmed Nabeeh
 
Game Based Learning for Language Learners
Game Based Learning for Language LearnersGame Based Learning for Language Learners
Game Based Learning for Language LearnersShelly Sanchez Terrell
 
Connecting With the Disconnected
Connecting With the DisconnectedConnecting With the Disconnected
Connecting With the DisconnectedChris Wejr
 

Andere mochten auch (6)

Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentationSun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
 
Sun fire x4140, x4240, x4440 server customer presentation
Sun fire x4140, x4240, x4440 server customer presentationSun fire x4140, x4240, x4440 server customer presentation
Sun fire x4140, x4240, x4440 server customer presentation
 
Power Searching Google And Google Scholar
Power Searching Google And Google ScholarPower Searching Google And Google Scholar
Power Searching Google And Google Scholar
 
Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini link
 
Game Based Learning for Language Learners
Game Based Learning for Language LearnersGame Based Learning for Language Learners
Game Based Learning for Language Learners
 
Connecting With the Disconnected
Connecting With the DisconnectedConnecting With the Disconnected
Connecting With the Disconnected
 

Ähnlich wie Sun sparc enterprise t5440 server technical presentation

Trend - HPC-29mai2012
Trend - HPC-29mai2012Trend - HPC-29mai2012
Trend - HPC-29mai2012Agora Group
 
Fujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU SpecificationsFujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU Specificationsinside-BigData.com
 
Exaflop In 2018 Hardware
Exaflop In 2018   HardwareExaflop In 2018   Hardware
Exaflop In 2018 HardwareJacob Wu
 
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Jeff Larkin
 
HP - HPC-29mai2012
HP - HPC-29mai2012HP - HPC-29mai2012
HP - HPC-29mai2012Agora Group
 
Introducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsIntroducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsAnalog Devices, Inc.
 
SUN主机产品介绍.ppt
SUN主机产品介绍.pptSUN主机产品介绍.ppt
SUN主机产品介绍.pptPencilData
 
IBM System x3850 X5 Technical Presenation abbrv.
IBM System x3850 X5 Technical Presenation abbrv.IBM System x3850 X5 Technical Presenation abbrv.
IBM System x3850 X5 Technical Presenation abbrv.meye0611
 
2013 02 08 annunci power 7 plus sito cta
2013 02 08 annunci power 7 plus sito cta2013 02 08 annunci power 7 plus sito cta
2013 02 08 annunci power 7 plus sito ctaLorenzo Corbetta
 
Sparc t4 2 system technical overview
Sparc t4 2 system technical overviewSparc t4 2 system technical overview
Sparc t4 2 system technical overviewsolarisyougood
 
QsNetIII, An HPC Interconnect For Peta Scale Systems
QsNetIII, An HPC Interconnect For Peta Scale SystemsQsNetIII, An HPC Interconnect For Peta Scale Systems
QsNetIII, An HPC Interconnect For Peta Scale SystemsFederica Pisani
 
If AMD Adopted OMI in their EPYC Architecture
If AMD Adopted OMI in their EPYC ArchitectureIf AMD Adopted OMI in their EPYC Architecture
If AMD Adopted OMI in their EPYC ArchitectureAllan Cantle
 
GPUDirect RDMA and Green Multi-GPU Architectures
GPUDirect RDMA and Green Multi-GPU ArchitecturesGPUDirect RDMA and Green Multi-GPU Architectures
GPUDirect RDMA and Green Multi-GPU Architecturesinside-BigData.com
 
Cisco UCS - Servidores
Cisco  UCS  - ServidoresCisco  UCS  - Servidores
Cisco UCS - ServidoresBruno Banha
 

Ähnlich wie Sun sparc enterprise t5440 server technical presentation (20)

Trend - HPC-29mai2012
Trend - HPC-29mai2012Trend - HPC-29mai2012
Trend - HPC-29mai2012
 
Ibm power7
Ibm power7Ibm power7
Ibm power7
 
Sun Microsystems
Sun MicrosystemsSun Microsystems
Sun Microsystems
 
Gpu archi
Gpu archiGpu archi
Gpu archi
 
Fujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU SpecificationsFujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU Specifications
 
Exaflop In 2018 Hardware
Exaflop In 2018   HardwareExaflop In 2018   Hardware
Exaflop In 2018 Hardware
 
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
 
HP - HPC-29mai2012
HP - HPC-29mai2012HP - HPC-29mai2012
HP - HPC-29mai2012
 
Fpga technology
Fpga technologyFpga technology
Fpga technology
 
Introducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsIntroducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin Processors
 
Cuda tutorial
Cuda tutorialCuda tutorial
Cuda tutorial
 
SUN主机产品介绍.ppt
SUN主机产品介绍.pptSUN主机产品介绍.ppt
SUN主机产品介绍.ppt
 
IBM System x3850 X5 Technical Presenation abbrv.
IBM System x3850 X5 Technical Presenation abbrv.IBM System x3850 X5 Technical Presenation abbrv.
IBM System x3850 X5 Technical Presenation abbrv.
 
2013 02 08 annunci power 7 plus sito cta
2013 02 08 annunci power 7 plus sito cta2013 02 08 annunci power 7 plus sito cta
2013 02 08 annunci power 7 plus sito cta
 
Phytium 64 core cpu preview
Phytium 64 core cpu previewPhytium 64 core cpu preview
Phytium 64 core cpu preview
 
Sparc t4 2 system technical overview
Sparc t4 2 system technical overviewSparc t4 2 system technical overview
Sparc t4 2 system technical overview
 
QsNetIII, An HPC Interconnect For Peta Scale Systems
QsNetIII, An HPC Interconnect For Peta Scale SystemsQsNetIII, An HPC Interconnect For Peta Scale Systems
QsNetIII, An HPC Interconnect For Peta Scale Systems
 
If AMD Adopted OMI in their EPYC Architecture
If AMD Adopted OMI in their EPYC ArchitectureIf AMD Adopted OMI in their EPYC Architecture
If AMD Adopted OMI in their EPYC Architecture
 
GPUDirect RDMA and Green Multi-GPU Architectures
GPUDirect RDMA and Green Multi-GPU ArchitecturesGPUDirect RDMA and Green Multi-GPU Architectures
GPUDirect RDMA and Green Multi-GPU Architectures
 
Cisco UCS - Servidores
Cisco  UCS  - ServidoresCisco  UCS  - Servidores
Cisco UCS - Servidores
 

Mehr von xKinAnx

Engage for success ibm spectrum accelerate 2
Engage for success   ibm spectrum accelerate 2Engage for success   ibm spectrum accelerate 2
Engage for success ibm spectrum accelerate 2xKinAnx
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep diveAccelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep divexKinAnx
 
Software defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudSoftware defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudxKinAnx
 
Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 xKinAnx
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...xKinAnx
 
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directionsxKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...xKinAnx
 
Presentation disaster recovery in virtualization and cloud
Presentation   disaster recovery in virtualization and cloudPresentation   disaster recovery in virtualization and cloud
Presentation disaster recovery in virtualization and cloudxKinAnx
 
Presentation disaster recovery for oracle fusion middleware with the zfs st...
Presentation   disaster recovery for oracle fusion middleware with the zfs st...Presentation   disaster recovery for oracle fusion middleware with the zfs st...
Presentation disaster recovery for oracle fusion middleware with the zfs st...xKinAnx
 
Presentation differentiated virtualization for enterprise clouds, large and...
Presentation   differentiated virtualization for enterprise clouds, large and...Presentation   differentiated virtualization for enterprise clouds, large and...
Presentation differentiated virtualization for enterprise clouds, large and...xKinAnx
 
Presentation desktops for the cloud the view rollout
Presentation   desktops for the cloud the view rolloutPresentation   desktops for the cloud the view rollout
Presentation desktops for the cloud the view rolloutxKinAnx
 

Mehr von xKinAnx (20)

Engage for success ibm spectrum accelerate 2
Engage for success   ibm spectrum accelerate 2Engage for success   ibm spectrum accelerate 2
Engage for success ibm spectrum accelerate 2
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep diveAccelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
 
Software defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudSoftware defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloud
 
Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 Ibm spectrum virtualize 101
Ibm spectrum virtualize 101
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
 
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
 
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
 
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
 
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
 
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
 
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
 
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
 
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
 
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
 
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
 
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
 
Presentation disaster recovery in virtualization and cloud
Presentation   disaster recovery in virtualization and cloudPresentation   disaster recovery in virtualization and cloud
Presentation disaster recovery in virtualization and cloud
 
Presentation disaster recovery for oracle fusion middleware with the zfs st...
Presentation   disaster recovery for oracle fusion middleware with the zfs st...Presentation   disaster recovery for oracle fusion middleware with the zfs st...
Presentation disaster recovery for oracle fusion middleware with the zfs st...
 
Presentation differentiated virtualization for enterprise clouds, large and...
Presentation   differentiated virtualization for enterprise clouds, large and...Presentation   differentiated virtualization for enterprise clouds, large and...
Presentation differentiated virtualization for enterprise clouds, large and...
 
Presentation desktops for the cloud the view rollout
Presentation   desktops for the cloud the view rolloutPresentation   desktops for the cloud the view rollout
Presentation desktops for the cloud the view rollout
 

Kürzlich hochgeladen

Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebUiPathCommunity
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfLoriGlavin3
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity PlanDatabarracks
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024Stephanie Beckett
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfHyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfPrecisely
 
Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteDianaGray10
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsSergiu Bodiu
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024Lonnie McRorey
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsPixlogix Infotech
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyAlfredo García Lavilla
 

Kürzlich hochgeladen (20)

Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio Web
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdf
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity Plan
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special Edition
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfHyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
 
Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test Suite
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platforms
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and Cons
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easy
 

Sun sparc enterprise t5440 server technical presentation

  • 1. Sun SPARC Enterprise T5440 Rack Servers Train-the-Trainer Course Presenter Sun Microsystems, Inc. Sun Confidential CDA Required 1
  • 2. NDA Notification This presentation contains information related to projects that are currently in planning and/or development stages. This information represents the current intentions of Sun Microsystems, Inc. However, all aspects of these projects, including, but not limited to funding, availability, shipping dates, configurations, capacities, performance, and all other characteristics are subject to change and/or cancellation without notice. This material is confidential to Sun Microsystems and should be disclosed to non- employees only under the terms of an executed confidential-disclosure agreement. Distribution of this material to Sun Field Representatives should be done through the GSO CDA process. Under no circumstances should these roadmaps be given directly to a Sun Field Representative. The information contained herein is considered privileged, confidential and protected from disclosure. If you are not the intended recipient or their employee/agent responsible for its delivery, you are requested to refrain from any duplication or distribution of this message or its contents, in respect of the rights of the designated recipient and sender and to delete it from your computer. Sun Internal and Approved Partners Only 2
  • 3. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC T2 Plus • Sun SPARC Enterprise T5440 server > Overview of Features > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 3
  • 4. Industry's Most Highly Threaded Servers Maximum Threading = Higher Throughput, Greater Energy & Space Efficiency T5440 Up to 256 Threads T5140/T5240 Up to 128 Threads T5120/T5220 Up to 64 Threads SB6320 US T2 blade Sun Internal and Approved Partners Only 4
  • 5. UltraSPARC T2: • Up to 8 cores @1.2GHz or 1.4GHz TrueSystem On a Chip • Up to 64 threads per CPU • Up to 16 FB-DIMMs, 4 memory controllers FB DIMM FB DIMM FB DIMM FB DIMM > Up to 64GB memory (4GB DIMMs) > 2.5x memory BW of UltraSPARC T1 FB DIMM FB DIMM FB DIMM FB DIMM • 8 x fully pipelined Floating Point units / core, 1 per core MCU MCU MCU MCU • Dual 10Gbit Ethernet and PCI-E integrated onto chip L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ • 4MB L2 (8 banks) 16 way associative Full Cross Bar • Enhanced MAU/Security co-processor C0 C1 FPU FPU C2 FPU C3 FPU C4 FPU C5 FPU C6 FPU C7 FPU per core MAU MAU MAU MAU MAU MAU MAU MAU > DES, 3DES, AES, RC4, SHA1, DMA Sub-System SHA256, MD5, RSA to 2048 key, ECC,CRC32 NIU Sys I/F • Advanced Power saving features (E-net+) Buffer Switch Core PCI-E • 65nm process technology Power ~95W <1.5W/thread x8 @2.5GHz 2x 10GE Ethernet 4GBytes/s bi-directional Sun Internal and Approved Partners Only 5
  • 6. UltraSPARC T2 Processor SPC SPARCv9 CMT Core L2 Data L2 Data Bank 0 Bank 4 CCX Core-Cache Crossbar L2B0 SPARC SPARC SPARC SPARC L2B4 L2$ Level 2 Cache Bank L2 Data Core 0 Core 1 Core 5 Core 4 L2 Data CLC Coherence & Link Controller Bank 1 Bank 5 MCU Memory Control Unit L2B1 L2B5 SIU System Interface Unit L2 L2 L2 L2 MCU0 MCU2 NCU Non-cacheable Unit NCU TAG0 TAG1 TAG5 TAG4 FSR MAC Media Access Controller EFU MCU1 MCU3 DMU Data Management Unit SIO SII L2B3 CCX L2B7 FSR CCU PEU PCI Express Unit L2 Data L2 Data Bank 3 Bank 7 L2 L2 L2 L2 L2B2 L2B6 TAG2 TAG3 TAG7 TAG6 L2 Data L2 Data Bank 2 Bank 6 SPARC SPARC SPARC SPARC DMU Core 2 Core 3 Core 7 Core 6 RDP TDS PEU RTX PSR ESR FSR MAC For a video tour with Rick Hetherington, go to http://www.youtube.com/watch?v=B8DNexYcsa4 Sun Internal and Approved Partners Only 6
  • 7. UltraSPARC T2 Plus: • Per Socket Multi-Socket US T2 > Up to 8 cores @1.2GHz or Each Coherency Link 6.4GBytes/s per direction, 12.8GB/s total 1.4GHz 4 x Coherency links give Snoop bandwidth of 51.2GB/s > Up to 64 Threads per socket 4x Coherency > 4MB L2$ 8 banks x 16 Way SA Links > Up to 8 FPU's, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > Up to 8 Crypto cores, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > DES, 3DES, AES, RC4, SHA1, SHA256, MD5, RSA to 2048 key, ECC,CRC32 MCU MCU > 2 memory Controllers, 16 DIMMS CU CU CU CU > 25Read+13WriteGB/s Memory BW L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ > One x8 PCIe interface Full Cross Bar • Per system CO C1 C2 C3 C4 C5 C6 C7 > 2 sockets glue-less FPU MAU FPU MAU FPU MAU FPU MAU FPU MAU FPU MAU FPU MAU FPU MAU > 4 sockets using UST2 Plus XBR > 16 or 32 PCIe lanes on 2 or 4 System I/F PCI-Express Socket systems • 65nm process technology SSI x8 @2.5GHz Bus Power ~105W 4GBytes/s <1.5W/thread bi-directional Sun Internal and Approved Partners Only 7
  • 8. UltraSPARC T2 Plus Processor SPC SPARCv9 CMT Core CCX Core-Cache Crossbar L2$ Level 2 Cache Bank CLC Coherence & Link Controller MCU Memory Control Unit SIU System Interface Unit NCU Non-cacheable Unit NCX Non-cacheable Crossbar DMU Data Management Unit PEU PCI Express Unit Sun Internal and Approved Partners Only 8
  • 9. CMT Processor Comparison UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 Plus Technology 90nm 65nm 65nm # of Cores 8 8 8 # of Threads 32 64 64 # of Sockets 1 1 1–4 Core Frequency (Ghz) 1 – 1.4 1.2 – 1.4 1.2 – 1.4 Execution pipelines per core 1 2 2 Instructions per cycle per pipe 1 1 1 FPUs per chip 1 8 8 I$ size (per core) 16KB 16KB 16KB D$ size (per core) 8KB 8KB 8KB L2$ size/Set Association 3MB/12-Way 4MB/16-Way 4MB/16-Way Memory Type DDR2 FBDIMM-1 FBDIMM-1 Memory Bandwidth (GB/s) 21.3 42READ + 21WRITE 25READ + 13WRITE Coherence Bandwdth (GB/s) - - 4 x (6.4READ +6.4WRITE) IO Bus JBUS x8 PCIe x8 PCIe IO Bandwidth (GB/s) 2.5 2+2 2+2 On-chip Networking - 2 x 10GE - Crypto Acceleration RSA RSA, RC4, DES, 3DES, AES, SHA1-256, MD5 Power (Watts, Watts/thread) 72, 2.25 95, 1.5 105, 1.6 * Sun Internal and Approved Partners Only 9
  • 10. UltraSPARC T2 Plus 2-Socket System Coherency Links Dual Channel Dual Channel Dual Channel Dual Channel FBDIMM FBDIMM FBDIMM FBDIMM Memory Controller Memory Controller Memory Controller Memory Controller Coherence Coherence Coherence Coherence Coherence Coherence Coherence Coherence Unit Unit Unit Unit Unit Unit Unit Unit UltraSPARC T2 Plus Cores, Crossbar, L2$ UltraSPARC T2 Plus Cores, Crossbar, L2$ (8 cores, 64 threads, 4MB L2$) (8 cores, 64 threads, 4MB L2$) PCI-Express NCU, DMU NCX PCI-Express NCU, DMU NCX System IO (Network, Disk, etc.) Sun Internal and Approved Partners Only 10
  • 11. UltraSPARC T2 Plus 4-Socket System 6.4GB/s 6.4GB/s Dual Channel FBDIMM Dual Channel US T2 Plus US T2 Plus FBDIMM PCI-Express PCI-Express 8 Cores 6.4GB/s 6.4GB/s 8 Cores 6.4GB/s 6.4GB/s 64 Threads Coherence 64 Threads Dual Channel 4MB L2$ 4MB L2$ Coherence(4) Hubs FBDIMM Dual Channel FBDIMM Coherence Coherence UltraSPARC Hubs (4) Hubs (4) HubsPlus T2 (4) 6.4GB/s XBR 6.4GB/s 44 ports/hub ports/hub 6.4GB/s 4 ports/hub 6.4GB/s Dual Channel inin each dir each dir FBDIMM Dual Channel in each dir FBDIMM PCI-Express US T2 Plus VF 4 ports/hub US T2 Plus PCI-Express 6.4GB/s per port 6.4GB/s 6.4GB/s 8 Cores 8 Cores in each dir 6.4GB/s 8 Cores 6.4GB/s 64 Threads 8 Threads/Core 64 Threads Dual Channel FBDIMM 4MB L2$ 4MB L2$ Dual Channel 4MB L2$ FBDIMM 6.4GB/s 6.4GB/s Sun Internal and Approved Partners Only 11
  • 12. US T2 Plus XBR Coherency Hub Chips... • 4 XBR chips in a system • XBR routes non-cacheable PIOs to the • Each operates in its own appropriate IO device Coherency Plane(CP) > Forwarded to the Zambezi that owns the > A region of addressable space, unique address space for processing to that plane • DMA reads and writes are done > Each XBR only tracks addresses in its own space through cachable memory space just > Serializes accesses to coherent loads, like processor initiated memory stores and writebacks (TSO model) accesses > 40 bit Physical Address used • CP links are based on an FB-DIMM > VF Snoop links to pass transactions physical interface, but a Sun protocol • Cacheable transactions > 6.4GBps/Direction/Port – Most Memory transactions > 51.2GB/s bandwidth total • Non-Cacheable transactions > CP links are tolerant to a single lane failure – IO, Non-cachable memory, (14 lanes per link) Interrupts etc. Coherency Plane > CRC and replay features in the protocol Mem Interleave by Designator allow no-stop recovery Coherency Plane Cachable/ Non-Cachable Coherency plane Designator (512B/1GB) > Memory structures are Parity protected 39 31 30 40 Bit Physical Address 10 9 8 7 0 Sun Internal and Approved Partners Only 12
  • 13. UltraSPARC T2/Plus CPU Core Block Diagram • IFU – Instruction Fetch Unit > 16 KB I$, 32B lines, 8-way SA TLU IFU > 64-entry fully-associative ITLB • EXU0/1 – Integer Execution Units > 4 threads share each unit > Executes one integer instruction/cycle EXU0 EXU1 • LSU – Load/Store Unit > 8KB D$, 16B lines, 4-way SA MMU/ > 128-entry fully-associative DTLB HWTW • FGU – Floating/Graphics Unit • SPU – Stream Processing Unit > Cryptographic acceleration SPU FGU LSU • TLU – Trap Logic Unit > Updates machine state, handles exceptions and interrupts • MMU – Memory Management Unit > Hardware tablewalk (HWTW) Gasket – TLB miss handled by hardware > 8KB, 64KB, 4MB, 256MB pages xbar/L2 Sun Internal and Approved Partners Only 13
  • 14. Floating Point Unit • Each Core has its own Floating Point Unit. This removes completely the 2% FP restriction of T1. • Only a 6 cycle penalty to the FPU > T1 required upwards of 28 cycles • Fully-pipelined (except divide/sqrt) Data > Divide/sqrt in parallel with add or multiply operations of other threads • Full VIS 2.0 implementation in hardware, no emulation • FPU performs integer multiply, divide, population count • Multiplier incorporates enhancements for offloading modular arithmetic operations to the Crypto Unit ● ● Sun Internal and Approved Partners Only 14
  • 15. UltraSPARC T2 Plus Crypto Performance Absolute maximums, measured by engineering using micro-benchmarks Application throughputs will be lower than these numbers Iterations/ Block Cycles/ Function Comment Block (bytes) Block GB/S DES 2 rounds/cycle 16 rounds 8 8/9+ 12.0 3DES 2 rounds/cycle 48 rounds 8 25/24 4.0 RC4 3 overlapped cycles 1 1 37683 12.0 Data into 44 words with UltraSPARC T2 Plus AES-128K 4 words - - 32 - AES-192K 6 words into 52 words - - 37 - New Ciphers AES-256K 8 words into 60 words - - 41 - AES-128 2 column over two cycles 10 rounds 16 30/30 6.36 AES-192 2 column over two cycles 12 rounds 16 36/36 5.28 AES-256 2 column over two cycles 14 rounds 16 42/42 4.56 SHA-1 2 cycles per step 80 steps 64 160/160 4.80 SHA-256 2 cycles per step 64 steps 64 128/128 6.00 MD5 2 cycles per step 64 steps 64 128/128 6.00 CRC32c 32 bits per cycle 1 4 1 48.00 Wire Speed for UltraSPARC T2 Plus is around 5 GB/S 16,000 new SSL sessions/sec using 1024 Asymmetric Key Exchange Export restrictions apply to some of the ciphers, requires installation of the Crypto Enabling patch to use. Purchase a CD which contains the patch. Affects IPsec related ciphers, SSL typeSun Internal and Approved Partners Only acceleration is unaffected and does not need enabling. 15
  • 16. FB-DIMM Memory Interface Feature UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 Plus Require Pins 1000 440 208 Available Bandwidth 23GBytes/second 50Gbytes/second 37.5Gbytes/second/socket Up to 64x DIMM slots Up to 32x DIMM slots/socket Memory Capacity up to 16x DIMM slots T5x20 uses 16 DIMM slots T5x40 uses 8/16 DIMM slots Data Memory Controllers 4 4 2 Memory Latency 96ns 126ns 126ns DIMM speeds 400MHz 667MHz 667MHz DIMM Power 7watts/DIMM 12.5Watts/DIMM 12.5Watts/DIMM ● ● Sun Internal and Approved Partners Only 16
  • 17. 10/100/1000/10GbE Network Interfaces • Uses the Neptune Chip on the Motherboard which provides > Two RJ-45 ports dedicated for 10/100/1000 > Two RJ-45 ports capable of 10/100/1000 – Fitting a XAUI adapter disables the one of these ports per XAUI • Same 10 GbE XAUI cards as T5x20 server • 16 Rx and 24 Tx DMA channels for virtualization – Integrated NIU in T2 has 16 Tx channels Data – Raw UDP Tx performance on Neptune > T2 NIU – T2 processor network typically outperforms Neptune on most network benchmarks • Packet classification > Rx data can be HW classified at layer 2 ,3 and 4 – Put into the separate Rx DMA buffers by classification rules • Same 'nxge' device driver as T2 NIU. • Performance estimates, testing/tuning ongoing – 1 port 10GbE TX/RX = 9.3 Gbps with CPUs still 65-75% idle ● – 2 port 10GbE TX/RX = 12-19Gbps (better if dedicate RX/TX ports) ● Sun Internal and Approved Partners Only 17
  • 18. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 18
  • 19. SPARC Enterprise Compute Density • 4RU chassis T5440 • 4-sockets – UltraSPARC T2 Plus Quad Socket US T2 Plus > Up to 32 cores @ 1.2GHz or 1.4Ghz > Up to 256 threads • Up to 64 FBDIMM slots > 512 GB of memory (using 8GB DIMMS) Reliable • 4 Hot-Plug 2.5” SAS disks (Raid 0,1) • DVD-RW • 4 x Redundant(2+2), hot-swappable PSUs ● Up to 256 threads / 512GB memory • 4 x Redundant, hot-swappable Fans • 2N PSU Redundancy, 1900 watts typical in a robust, redundant chassis consumption ● Taking CMT to the Mid-Range Expandable • 4 x Processor+Memory card pairs ● LDOMs consolidation dream box • 8 x8 PCIe expansion slots (2 x XAUI) • 4 Gigabit Ethernet (or up to 2 x 10GbE and 2 x1GbE) • 4 x USB 2.0 Sun Internal and Approved Partners Only 19
  • 20. T5440 Standard Configurations (PTO) Part Number Description 4RU 2 x 1.2GHz, 8 Core CPU, 32GB (16 X 2GB), 2x 146GB SAS 2.5”disks, 4x SEVPCJF1Z 1120W PSU, DVD-RW, 2 x Memory Expansion Boards 4 x 1.2GHz, 8 Core CPU, 64GB (32 X 2GB), 2x 146GB SAS 2.5”disks, 4x SEVPGLF1Z 1120W PSU, DVD-RW, 4 x Memory Expansion Boards 4 x 1.4GHz, 8 Core CPU, 128GB (32 X 4GB), 2x 146GB SAS 2.5”disks, SEVPHSF1Z 4x 1120W PSU, DVD-RW, 4 x Memory Expansion Boards ● All configs feature... ● 4 x 1GbE interface, ● 1 x DVD-RW slimline drive ● 8 x PCIe 8 lane slots (2 shared XAUI slots), 2 x16 mechanical ● 4 x USB 2.0 slots (2 front/2 back) ● 1 x DB9 Serial port ● 4 x Redundant, Hot-plug PSUs ● 4 x Redundant, hot-plug fans ● 2 x 146GB 2.5” SAS drives (can accommodate up to 4 drives) ● RAID 0,1 from onboard LSI 1068E controller ● 1 Year On-Site Warranty ● Rack mount kit with cable management arm ● 4 x Power Supply cables (country specific) Sun Internal and Approved Partners Only 20
  • 21. Sun Fire T5240/T5440 Differences Feature SPARC Enterprise T5240 SPARC Enterprise T5440 Form Factor 2U, 28” deep 4U, 24.5” deep 2x UltraSPARC T2 Plus Up to 4 x UltraSPARC T2 Plus CPU 1.2/1.4 GHz 64-128 threads 1.2/1.4 GHz 128-256 threads FB-DIMM 128GB MAX FB-DIMM, 512GB MAX Memory 32x slots 64x Slots 4x GbE or 4x GbE or Network 3 x GbE + 1 x 10GbE or 3 x GbE + 1 x 10GbE or 2 x GbE + 2 x 10GbE 2 x GbE + 2 x 10GbE Internal Storage Up to 16 x 2.5” SAS, hot-swap Up to 4 x 2.5” SAS, hot-swap Removable Media 1x DVD-RW 1x DVD-RW Serial 1x RS-232, 4x USB 1x RS-232, 4x USB PCI Express slots 6x (low profile) 8x (low profile) 2x 1100W AC/2 x1200Watt DC 4 x 1120W AC Power Supply Redundant/Hot-Swap Redundant/Hot-Swap Fans 5x Redundant/Hot-Swap 4 x Redundant Hot-Swap Sun Internal and Approved Partners Only 21
  • 22. Front Panel Service Required LED Power/OK LED Locator LED Power Button /Button Front Fan Fault LED System Label PSU Fault LED System Overheat Fault LED Serial Number label DISK 2 DISK 3 DVD-RW DISK 0 DISK 1 Dual USB 2.0 ports Sun Internal and Approved Partners Only 22
  • 23. Rear Panel PCI Card Securing Latches (internal) PSU Status LED's PSU 3 PSU 2 PSU 1 PCI 0 PCI 1 PCI 2 PCI 3 PCI 4 PCI 5 PCI 6 PCI 7 PCI 0 PCI 2 PCI 3 PCI 5 PCI 6 PCI 7 PSU 0 PCI 0 = PCIe x8, mechanical x8 Quad Gigabit PCI 1 = PCIe x8, mechanical x16 SP Ethernet Ports Serial PCI 2 = PCIe x8, mechanical x8 Port SP NET 2 NET 3 Network PCI 3 = PCIe x8, mechanical x8 POSIX DB-9 Chassis Port Serial Port Status LED's Dual PCI 4 = PCIe x8, mechanical x8, or XAUI 0 Card and Locator Button USB 2.0 NET 0 NET 1 Ports PCI 5 = PCIe x8, mechanical x8, or XAUI 1 Card XAUI 1 XAUI 0 PCI 6 = PCIe x8, mechanical x16 PCI 7 = PCIe x8, mechanical x8 Sun Internal and Approved Partners Only 23
  • 24. Sun Fire T5440 Block Diagram Mem CPU CPU Mem Mem CPU CPU Mem CPU Module = Module Module Module Module Module Module Module Module - 1 x VF CPU 0 0 2 2 1 1 3 3 - 4 x FB-DIMM Slots Mem Module = - 12 x FB-DIMM Slots Plus Plus Plus Plus T2 T2 T2 T2 x4 VRM VRM VRM VRM VRM VRM VRM VRM SAS LSI1068e x8 SAS 4x FB Links SSI SSI 4x FB Links 4x FB Links SSI SSI 4x FB Links PCIe x8 PCIe x8 PCIe x8 CL0 CL0 PCIe x8 US T2 XBR LPC CL0 0 CL0 x8 CL1 CL1 x8 x8 PLX3 PLX2 x8 US T2 XBR LPC PLX1 PLX0 PEX8548 PEX8548 CL1 CL1 PEX8548 PEX8548 1 x8 x1 x8 CL2 CL2 x8 x8 US T2 XBR Zambezi x8 x8 x8 CL2 2 LPC CL2 x8 x8 PCIe-PCI x8 CL3 CL3 XAUI 1 XAUI 0 US T2 XBR LPC Neptune CL3 3 CL3 USB host x8 QUAD GbE USB Hub USB-IDE 4x SSI PHY LPC FPGA ILOM BCM5466R PCI Card BACK FRONT BACK 0 1 2 3 panel panel panel NET SER DB-9 0 1 2 3 4 USB 2.0 USB 2.0 DVD Sun Internal and Approved Partners Only MGT MGT Quad 10/100/1000 5 6 7 24
  • 25. Internal View with Cards installed(T5440) System Configuration 4 Fans are required Card (SCC)EEPROM MEM 3 PCIe 7 x8(m)/x8(e) PCIe 6 x16(m)/x8(e) MB/FT0 MB/FT2 MB/FT2 CPU 3 XAUI/PCIe 5 x8(m)/x8(e) CPU 1 MEM 1 Service Processor Daughter Card MEM 2 XAUI/PCIe 4 x8(m)/x8(e) CPU 2 MB/FT3 MB/FT1 MB/FT3 PCIe 3 x8(m)/x8(e) PCIe 2 x8(m)/x8(e) CPU 0 PCIe 1 x16(m)/x8(e) PCIe 0 x8(m)/x8(e) MEM 0 4 x SAS Disk Chassis Power Distribution Power Disk Board Chassis Supplies Power BUS Bars RED = +12Volts BLUE = Ground Chassis Intrusion Switch Extension to top cover from MBD Sun Internal and Approved Partners Only 25
  • 26. Internal View, cards removed(T5440) System Configuration US T2 Plus XBR Coherency Plane Chips Card (SCC)EEPROM PCIe 7 x8(m)/x8(e) MEM 3 PCIe 6 x16(m)/x8(e) MB/FT0 MB/FT2 MB/FT2 CPU 3 XAUI 1/PCIe 5 x8(m)/x8(e) CPU 1 MEM 1 Service Processor Daughter Card MEM 2 XAUI 0/PCIe 4 x8(m)/x8(e) CPU 2 MB/FT3 MB/FT1 MB/FT3 PCIe 3 x8(m)/x8(e) PCIe 2 x8(m)/x8(e) CPU 0 PCIe 1 x16(m)/x8(e) PCIe 0 x8(m)/x8(e) MEM 0 Power Distribution Power Disk Board Chassis Supplies Chassis SeperatorFence Sun Internal and Approved Partners Only 26
  • 27. Internal View, Motherboard only(T5440) Neptune Quad DC-DC Converter Modules GbE/10GbE NIC MEM 3 CPU 3 MB/FT0 MB/FT2 MB/FT2 Quad GbE RJ-45 Ports CPU 1 NET MGT port Dual USB 2.0 Port MEM 1 System Status LEDs SER MGT port MEM 2 DB-9 Serial Port CPU 2 Service Processor Card Connector MB/FT3 MB/FT1 CPU 0 MEM 0 PLX PCIe Switch Chips 'Southbridge' Peripheral Chip Fan connectors, with LSI1068E Disk Controller speed control logic Sun Internal and Approved Partners Only 27
  • 28. Motherboard and CPU/MEM Card layout MEM 3 CPU 3 CPU 1 MEM 1 MEM 2 CPU 2 CPU 0 MEM 0 Motherboard CPU/Mem Board Memory Board Sun Internal and Approved Partners Only 28
  • 29. Memory Configuration Rules • 1 or 4 CPU cards in a system > Each CPU card has an associated Memory Card Card/Chassis > Unpopulated Cards must be filled Top with spacers > Unpopulated DIMMs must be filled UltraSPARC T2 Plus with spacers VRM CPU • All DIMMS on a CPU & Memory VRM card pair must be the same size BR1/CH0/DO BR1/CH1/DO BANK 0 > 2GB, 4GB or 8GB only (no BR0/CH0/DO VRM Install ALL DIMMs 1GB) BR0/CH1/DO > May support Different DIMM sizes on different pairs... BR1/CH1/D2 BR1/CH1/D3 BANK 3 • 3 Configs... BR1/CH0/D2 BR1/CH0/D3 Install ALL DIMMs > Fill Bank 0 BR0/CH1/D2 BANK 2 > Fill Banks 0,1 VRM BR0/CH1/D3 Install ALL DIMMs BR0/CH0/D2 > Fill Banks 0,1,2,3 BR0/CH0/D3 BR0/CH1/D1 VRM BR0/CH0/D1 BANK 1 • All standard configs provide Install ALL DIMMs BR1/CH1/D1 BR1/CH0/D1 exactly 8 free DIMM slots simultaneously Sun Internal and Approved Partners Only 29
  • 30. Network Ports and Options XAUI 0 XAUI 1 Device NET 0 NET 1 NET 2 NET 3 XAUI 0 XAUI 1 Driver nxge0 nxge1 nxge2 nxge3 nxge0* nxge1* PCI Device PCI@500/0/c/0,0 PCI@500/0/c/0,1 PCI@500/0/c/0,2 PCI@500/0/c/0,3 PCI@500/0/c/0,0 PCI@500/0/c/0,1 NOTES All Ethernet ports provided by a single Neptune Chip on the motherboard NET 2 NET 3 NET 0 and NET 1 are disabled by XAUI 1 and XAUI0,if installed, to take advantage of 10GbE networking * If a XAUI card is installed, the matching RJ-45 port is disabled (NET 0 and NET 1) XAUI cards take one of three current Fibre 10GbE transceivers Short Reach(SR), Long Reach(LR) and Long Reach Multimode(LRM) NET 0 NET 1 Copper versions of the XAUI card are expected Post-RR XAUI Cards consume the same physical space in the chassis as a PCI card, so are mutually exclusive with PCI cards in the same location Sun Internal and Approved Partners Only 30
  • 31. 10GbE XAUI Option Cards • Interface to the Neptune chip to upgrade two of its ports to 1GbE • Cards each consume a PCI-E slot if installed • Attach to dedicated XAUI sockets on special risers • 10Gbe XAUI Card – SESY7XA1Z > Requires Fibre Tranceivers – 10GbE Short Reach(SR) – SESY7XT1Z – 10GbE Long Reach (LR) – SESY7XT2Z – 10GbE Long Reach multimode (LRM) – part No. TBD • Copper connector XAUI versions to follow post-RR Sun Internal and Approved Partners Only 31
  • 32. PCIe Slots Built In • No Riser Cards are used, slots are directly on the motherboard • Low Profile PCI-Express cards only • Each Slot is capable of 25Watts power • Total power capacity limited to 140Watts > Systems design point was to accommodate 8 x 17.5Watt Atlas(Quad GbE using Neptune) card • Each Slot has x8 PCIe electrical capability and at least x8 mechanical connectors • Slots 1 and 6 have x16 mechanical connectors • XAUI cards in slots 4 and 5 replace PCIe cards in those slots Sun Internal and Approved Partners Only 32
  • 33. PCIe External IO Expansion Unit aka Expansion Chassis, I/O Box • Up to 2 x PCI Expansion Chassis are supported > P/N : SENX8BE1Z > 4RU, 19” rack compatible , 28” deep > 1 Host card supported per US T2 Plus > Each chassis is managed by host SP • Only support PCIe card IO boats ( PCI-X ?) > Each 'boat' requires an Link Card in the host (ensign) and a link Card in the boat (captain) with special card between them > IO 'boat' supports 6 x PCIe x8 full-length, hot- pluggable PCIe cards • Chassis default configs contain > 2 x Hot-plug redundant 600Watt PSU/FAN FRU's > 1 x PCIe 'boat', 1 link card pair(host-chassis) and cable > 6 x PCIe card carriers for x8 PCIe Cards > Customers can add a further PCIe 'boat' – P/N : SENX8TE1Z and more Sun Internal and Approved Partners Only 33
  • 34. Disk Drives • Disk drives are all 2.5” form factor • Original Galaxy NEMO bracket (not Marlin Bracket) • Support SAS only (Can mix SAS/SATA after qual) • SAS Drives – 73GB @ 10K RPM – 146GB @ 10K RPM – 73GB @ 15K RPM – SSD (post-RR) • Same disks as T2x00 systems Disk LED's Ready to Remove Fault Status Sun Internal and Approved Partners Only 34
  • 35. Disk Controller Options • T5440 has embedded LSI 1068E on the motherboard – JBOD up to 4 disks – Controls internal disks only – Unused 4 ports are not used – RAID 0 (striping) and RAID 1(mirroring) – Hot-plug supported – Hot-swap in non-RAID configs is done with 'cfgadm' • SGXPCIESAS-R-INT-Z NOT supported > Not available for T5440 due to chassis design and only 4 disk capacity • SGXPCIESAS-R-EXT-Z Supported – For external disk arrays only (no internal ports) – 8 port SAS RAID 0,1,1E,5,5EE,6,10,50,60 (depending on number of disks available) – Adaptec Card and Firmware with Intel SunRiseLake chipset – Battery Backed Write Cache (BBWC) of 256MB, at least 72 hours capacity, much longer when new Sun Internal and Approved Partners Only 35
  • 36. Fans and Cooling • Front to Back cooling • Two rows of fans provide redundancy > PSU fans provide sufficient redundancy for Disk cooling Back Front • Requires 4 Fans Disks PSU's – Main System Cooling MEM0 – MB/FT0 MB/FT2 MB/FT3 MB/FT3 CPU0 – MB/FT1 CPU2 Motherboard MEM2 – MB/FT2 MEM1 MB/FT1 MB/FT0 MB/FT1 – MB/FT3 CPU1 CPU3 – PSU integrated Fan Cooling flow MEM3 – Cools disk drives and PSU's – PSUFAN0 – PSUFAN1 – PSUFAN2 – PSUFAN3 Sun Internal and Approved Partners Only 36
  • 37. Fans modules and boards Fan Fault Amber LED Lit if fan faulty • 4 Fans Required > 60 Seconds grace if FAN removed for service • Fans are speed controlled by the Service Processor • Speeds are independantly monitored by SP • Speeds tuned to minimise vibrations > Built in vibration sensor • Speeds chosen to minimise harmonic resonance with disk drives and other fans. • Each fan has an Amber FAULT LED – if lit the fan module is faulty Sun Internal and Approved Partners Only 37
  • 38. Power Supplies • PSU's are high efficiency • Output 12V (and 3.3v standby) PSU Fault • Most DC-DC conversion done in MBD LED • Integrated Fans • 4 PSU's > 2 + 2 Redundancy (Grid Redundancy) > Rated at 1120Watts each. > BEWARE... – Same form factor as SunFire X4600 PSU's ... DO NOT MIX Sun Internal and Approved Partners Only 38
  • 39. Rack Mounting Options • Two Rack mounting options are available.. • Standard Rack Mount (4 post) > P/N : SEVY9RK1Z > Same as Sun Fire X4600 server > Standard configs contain this kit • Tool-less Rack Kit (4 post) > P/N : SEVY9RK2Z > Optional kit, purchased seperately > Snaps into Sun and most 3rd party Racks > Requires no tools to fit or remove > Will replace tool-required version once available Sun Internal and Approved Partners Only 39
  • 40. Solaris for Sun SPARC Enterprise T5x40 • T5x40 servers will require Solaris10 5/08 (update 5) with patches > A Patch CD is supplied in the box – Likely to be out of date, so customers should check SunSolve... • This incorporates several specific UltraSPARC T2/T2 Plus optimizations and for CMT servers in general • Also includes some specific T5x40 optimisations > UltraSPARC T2 Plus MPO optimisations > nxge driver tweaks for 10GbE devices > MMU DMA relaxed scheduling > LDOMs pre-install upgrade to version 1.0.3 (US T2 Plus support) Sun Internal and Approved Partners Only 40
  • 41. Solaris FMA • Now aware of CPU Core offlining • PCIe Fabric diagnostics improved • Crypto Unit offlining • Neptune awareness (though XAUI's not diagnosed) • POST memory CE tolerance improved • FRU identity info improved in fault reports (part/ser #) • Diagnostic Engines (DE) – Existing DE have been extended for T5x40 – New Eversholt DE used for HostBridge, PCIe diagnostics • Limitations... – Can't isolate Uncorrectable Errors to a single DIMM – PCIe riser cards not in topology – XAUI card and XFP not in the topology – SouthBridge chip is not diagnosed at this time (DVD, USB,...) – IO Expansion box is not diagnosed via FMA Sun Internal and Approved Partners Only 41
  • 42. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > System Architecture and Tours > Extra Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 3.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 42
  • 43. ILOM Features at a Glance • Hardware Control, Inventory, Monitoring • Host Configuration and Administration • SP Configuration and Administration • Logging, Auditing and Alerting • Authentication : – LDAP, RADIUS, Active Directory, Local Users • Services : – SSH, HTTP(S), NTP, Syslog, SMTP • Out-of-Band – Via Serial port, or dedicated Ethernet port • In-Band – Via Host OS, firmware upload, Explorer, Syslog Sun Internal and Approved Partners Only 43
  • 44. ILOM – Industry Standard Manageability • ILOM enables Sun systems to be easily integrated into third party management infrastructures • Key functionality > IPMI 2.0 > SNMP V1, V2c, V3 > SSH 2.0 > LDAP, RADIUS & MS Active Directory authentication > Browser UI, SMASH DMTF CLP + ALOM style CLI • NOTE : No RKVMS functionality like Galaxy ILOM > No Java plugin required • Browsers tested include, these base versions an later releases – Mozilla 1.7 on Solaris 10, IE 6.0 on W2K Server, Firefox 1.0 and 1.5 on W2K server Sun Internal and Approved Partners Only 44
  • 45. ILOM – Industry Standard Manageability • Identical to ILOM 2.0 for T5x20 • Default user is 'root' with password 'changeme' > Use for ILOM WEB GUI access and SSH access and IPMI • The ALOM 'admin' user is not defined by default, create this user with an ALOM CLI • Lost 'root' password and ILOM config is reset using jumpers > T5140/T5240 - Motherboard Jumper J10401 (short pins 1-2) > T5440 - SP Daughter card Jumper J1127 (short pins 1-2) • Note... 'sunservice' user shares the password of the 'root' user ONLY FOR SERVICE ACCESS* • Passwords must be 8 to 16 chars (used to be max 8) • Max of 10 users allowed (used to be 16) Sun Internal and Approved Partners Only 45
  • 46. ILOM Common Tasks • Setting up an ALOM 'admin' user from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. ->create /SP/users/admin role=Administrator cli_mode=alom Creating user... Enter new password: ******** Enter new password again: ******** Created /SP/users/admin2 -> exit SUNSP00144F4641BD login: admin Password: ******** Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. sc> Sun Internal and Approved Partners Only 46
  • 47. ILOM Common Tasks • Setting up ILOM IP configuration from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. -> set /SP/network state=enabled Set ’state’ to ’enabled’ -> set /SP/network pendingipaddress=10.8.31.163 Set ’pendingipaddress’ to ’10.8.31.163’ -> set /SP/network pendingipdiscovery=static Set ’pendingipdiscovery’ to ’static’ -> set /SP/network pendingipnetmask=255.255.252.0 Set ’pendingipnetmask’ to ’255.255.252.0’ Static IP -> set /SP/network pendingipgateway=10.8.31.248 configuration Set ’pendingipgateway’ to ’10.8.31.248’ -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> -> set/SP/pendingipdiscovery=dhcp Set ’pendingipdiscovery’ to ’dhcp’ -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> Dynamic IP (DHCP) configuration Sun Internal and Approved Partners Only 47
  • 48. ILOM IPMI functionality • IPMI is a widely used management protocol for x86 servers • ... But its new for SPARC boxes... • Download the required tools from > The Solaris Supplemental CD (an older binary package) > Latest is available at http://ipmitool.sourceforge.net – Binary packages (usually older versions) are available for Solaris x86 and SPARC, as well as Linux, Windows, Mac...etc > There is a Blueprint available from Sun also (mainly x64 centric, but applies to SPARC now too) – http://www.sun.com/blueprints/0107/820-1011.pdf -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sdr /MB/V_+1V0_VDD | 1.01 Volts | ok /MB/V_+3V3_STBY | 3.36 Volts | ok Get the Sensor /MB/V_+3V3_MAIN | 3.36 Volts | ok Data /MB/V_+5V0_VCC | 4.97 Volts | ok Repository /MB/V_+12V0_MAIN | 12.16 Volts | ok .. .. -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sunoem sbled set /SYS/LOCATE on /SYS/LOCATE | ON Set the System -bash-ventus2$ Locator LED flashing Sun Internal and Approved Partners Only 48
  • 49. ILOM Common Tasks • Logging into the ILOM Web GUI • Point Web Browser at the IP address of the ILOM > Will automatically redirect to a secure HTTPS port > Best to disable any Web Proxies for best performance > Make sure port 80, 443 are open on any firewall • Log in as any defined user, default Administration user is 'root' Sun Internal and Approved Partners Only 49
  • 50. ILOM/ALOM Common Tasks • A Tour of the ILOM Web GUI • GUI provides ways to set up IP address configurations for ILOM • Configure additional ILOM/ALOM users • Access Sensor Readings • Control System configurations • Carry out firmware updates. • etc.... Sun Internal and Approved Partners Only 50
  • 51. ALOM 2.0 vs. 1.4 CLI Differences • Default CLI appearance is ILOM – User is 'root' – Must create an 'admin' Administrator user with the ALOM CLI • Flashupdate in new ALOM expects a TFTP server not an FTP server • ALOM IP address changes now active only after running ... – 'setsc netsc_commit true' – Previously changes were active only after SC reset – DHCP is enabled by default • View firmware versions with – 'showhost version' sc> showhost version Sun System Firmware 7.0.0_build_13 2007/08/10 23:44 • Only Admin and Operator roles Host flash versions: Hypervisor 1.5.0.build_13**PROTOTYPE** 2007/08/10 22:54 OBP 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:25 are defined Sun Fire[TM] Huron POST 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:51 Sun Internal and Approved Partners Only 51
  • 52. ALOM backward Compatibilty CLI • Uses ALOM-CMT 1.2 for a base feature set • Includes ALOM-CMT 1.4 features... > break -d > Host Watchdog Timer > Bootmode LDOMs awareness > Forward SP events to Hot/Solaris syslog via inband channel Sun Internal and Approved Partners Only 52
  • 53. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > Comparison to SunFire T1000/T2000/T5x20 > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 53
  • 54. Logical Domains 1.0.3 Features • UltraSPARC T2 Plus Platform Support > 128 domains supported at RR – 256 domains work on T5440, may be qualified later, requires Solaris fixes • Feature Set very similar to 1.0.2 • I/O domain can reboot while the other domains keep running > Dependent domains would wait for I/O transactions to complete • LDoms SNMP MIB > Modeled after industry standard DMTF CIM (Common Information Model) > Running on control domain to enable remote SNMP monitoring • Domain minimization support > Minimal/reduced Solaris installation > Base minimal packages plus optional ones for guest, control, I/O or service domains Sun Internal and Approved Partners Only 54
  • 55. Logical Domains 1.0.3 Requirements • Solaris 10 05/08 (update 5) and required patches • Systems firmware version – T5x40 Firmware 7.1.5b = SP FW 2.0.4.20+ – T5x20/SB6320 Firmware 7.0.4+ = SP FW 2.0.4.0+ – T2000/T1000/T6300/Pelton Firmware 6.5.x • SUNWldm.v LDOMs Manager Package – Version 1.0.3 Sun Internal and Approved Partners Only 55
  • 56. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > Comparison to SunFire T1000/T2000/T5x20 > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 56
  • 57. Option Parts List for T5440(ATO) Part Number Option Description Available SEVY1CB1Z T2 Plus CPU module, 8 core, 1.2GHz, 8GB(4x2GB) with memory board RR SEVY1CC1Z T2 Plus CPU module, 8 core, 1.2GHz, 16GB(4x4GB) with memory board RR SEVY1CD1Z T2 Plus CPU module, 8 core, 1.2GHz, 32GB(4x8GB) with memory board SEVY1DD1Z T2 Plus CPU module, 8 core, 1.4GHz, 32GB(4x8GB) with memory board SEVY1DB1Z T2 Plus CPU module, 8 core, 1.4GHz, 8GB(4x2GB) with memory board Subject to 1.4GHz availability SEVY1DC1Z T2 Plus CPU module, 8 core, 1.4GHz, 16GB(4x4GB) with memory board Subject to 1.4GHz availability SESY2A1Z 2GB Memory Expansion kit(2x1GB) SESY2B2Z 4GB Memory Expansion kit(2x2GB) Non-Extended ECC version, no mixing SESY2D1Z 16GB Memory Expansion kit (2 X8 GB) SESY2C1Z 8GB Memory Expansion kit(2x4GB) SESVY3A11Z 73GB 10Krpm, 2.5” SAS Drive SESVY3C11Z 146GB 10Krpm, 2.5” SAS Drive SESVY3A21Z 73GB 15Krpm, 2.5” SAS Drive SEVY9PS51Z 1120W AC Power Supply SEVY9DV1Z DVD, 8x DVD-RW Slimline module SEVY9RK1Z Slide Rail Kit, Screw Mounting SEVY9RK2Z Slide Rail Kit, Toolless Mounting Sun Internal and Approved Partners Only 57
  • 58. Option Parts List for T5440 (cont..) Part Number Option Description Avialable Max number SG-XPCIE1FC-QF4 Qlogic, 4Gb, PCI-E Single Port RR 8 SG-XPCIE2FC-QF4 Qlogic, 4Gb, PCI-E Dual Port RR 8 SG-XPCIE1FC-EM4 Emulex, 4Gb, PCI-E Single Port RR 8 SG-XPCIE2FC-EM4 Emulex, 4Gb, PCI-E Dual Port RR 8 SG-XPCIE2SCSI-U320Z U320 SCSI, PCI-E Dual Port RR 8 SG-XPCIE8SAS-E-Z SAS, 8 Port, PCI-E RR 8 SGXCPCIESAS-R-EXT-Z SAS, 8 Port External RAID Controller RR 2 X7281A-2 Northstar Dual port GigE MMF Low profile PCI-E RR 8 X7280A-2 Northstar Dual port GigE UTP Low profile PCI-E RR 8 X1236A-Z Infiniband HBA, Dual 4x ports, PCI-E RR 8 X4447A-Z Atlas Quad Port, GigE Copper, PCI-E (up to 3/6) RR 8 X1027A-Z Atlas Dual Port, 10GigE, PCI-E RR 4 X5558A Tranceiver 10GE SR XFP (XAUI/Atlas) RR - X5560A-Z Tranceiver 10GE LR XFP (XAUI/Atlas) RR - X3000A-Z XVR-300, PCI-E x8 Graphics cards (up to 1) RR 4 SESY7XA1Z 10GbE XAUI card RR 2 TBD 10GbE XAUI Copper 10g Base-T TBD 2 X6000A Sun Crypto Accelerator 6000 RR 2 SENY8BE1Z External IO Expansion Unit – PCI-E base Config RR 2 SENY8TE1Z PCI-Express “boat” for External IO Expansion Unit (6 Hot Plug carriers) RR 4 SELY8LK1Z Copper link kit for IO Expansion unit “boat” RR 4 Sun Internal and Approved Partners Only 58
  • 59. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > Comparison to SunFire T1000/T2000/T5x20 > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 59
  • 60. Tuning Out of the Box • Using Solaris 10 05/08 (update 5) with Patches > MPO optimisations used > DMA relaxed Ordering implemented > Default pages sizes for – Initdata Segments is 64kB pages – Private Anon, Heap, Process Stack, Text, Shared Anon segments are 4MB pages – ISM and DISM use 256MB pages – New variables introduced to control these sizes if changes are needed – max_uheap_lpsize,max_ustack_lpsize, max_privmap_lpsize, max_shm_lpsize, max_uidata_lpsize, max_utext_lpsize, max_shm_lpsize > L2 Cache hashing implemented – helps randomise accesses to L2 caches and ease thrashing > Stack biasing implemented – D-Cache is only 4 Way associative... 8 threads – Running multiple copies of a binary can lead process stacks aligning in the cache and to hot lines in the cache – Stack Bias slews the stack variable for processes. Sun Internal and Approved Partners Only 60
  • 61. Tuning Out of the Box (continued..) > Processor Groups introduced – Helps associate CPUs with some shared resources (int/FP pipelines, Crypto units etc) – Enables improved multi-level CMT load balancing and affinity policies > 'bcopy'/'uiomove' Optimizations – Key kernel operations – new implementation about 2x faster than previous • Optimisations will require patching of S10 05/08 > These will be post RR patches as they become available > Most fixes are already committed in update 5 > Check patch levels for customers with performance issues > Also check Firmware versions as this can improve performance too... Sun Internal and Approved Partners Only 61
  • 62. Tuning Recommendations • Less involved than with T2000 • S10 5/08 is more 'automatic' – OOB optimised page size selection, thread scheduling, block copy, IP instances for zones, page coloring etc... • If tuning is necessary remember... > Improved pipeline results in Single threaded performance around 20% better > Floating Point is no longer an issue > Start with T2000 tuning options > Use updated trapstat, cpustat, • LDOMs may be an easier way to scale poorly threaded applications • Solaris Crypto framework is still being tuned > Great for big packets, working on improving small packets • A Blueprint is being prepared (Denis Sheahan) Sun Internal and Approved Partners Only 62
  • 63. Tuning Recommendations (cont..) • Refer to UltraSPARC T1 applications tuning best practices... > http://www.sun.com/servers/coolthreads/tnb/applications.jsp • CoolTools are being updated for UltraSPARC T2 and T2 Plus > http://www.sun.com/servers/coolthreads/overview/cooltools.jsp • Sun Studio 12 is UltraSPARC T1 and T2/T2 Plus aware > Recompiling without code changes should benefit T1/T2/T2 Plus apps • LDOMs configs can benefit significantly from a transition to T5x20 platform > Multiple IO/Service domains with higher bandwidth PCI busses > Make sure appropriate LDOMs tuning and sizing is carried out • Wider Crypto capability, so ensure code is using PKCS#11 framework > Ensure that the ncp (SSL, RSA, DSA etc) and n2cp (bulk ciphers), n2rng(random number generator) drivers are used appropriately Sun Internal and Approved Partners Only 63
  • 64. PCIe Performance • Easily two to four times the performance of T5x20 (two or four PCIe Busses) • All PCI card slots are x8 PCI electrically > Single level hierarchy > Cut through switching > PCI-E relaxed ordering for higher performance • Performance per bus... > Marketing performance = 4000MB/sec > Theoretical Rate with overheads = 3790MB/sec > Max. DMA Achievable(bidirectional) = 3096MB/sec – with 128byte packets – And 512 byte read size Sun Internal and Approved Partners Only 64
  • 65. Agenda • Introduction • Comparision of the UltraSPARC T2 to UltraSPARC VF • Sun SPARC Enterprise T5x40 servers > Overview of Features > System Architecture and Tours > Memory, Networking and IO Expansion > Disks, Fans and Power Supplies > Solaris for T5x40 • ILOM 2.0 • LDOMs for T5x40 • CRUs/FRUs and Configuration Options • Tuning and Performance • Tools, Information and References • Q & A ... Sun Internal and Approved Partners Only 65
  • 66. Tools and Information • Cool Tools – http://www.sun.com/servers/coolthreads/overview/cooltools.jsp • SUNWIN Tokens > Sun SPARC Enterprise T5440 – Architecture Whitepaper : 526122 – JTF : 526118 > T5440 RAS Whitepaper : TBA • Video Tours > Check the Sun.com product pages • Power Calculators > Check the Sun.com product pages Sun Internal and Approved Partners Only 66
  • 67. Further Information • Presto > T5440 > http://sunwebcollab.east.sun.com/gm/document-1.26.680780/Batoka_PRESTO.html • Installed Business Base (IBB) Promotions > http://sunwebcollab.east.sun.com/gm/document-1.26.680782/Batoka_IBB_Promo.html • Start Up Essentials program > http://sunwebcollab.east.sun.com/gm/document-1.26.680794/Maramba_Batoka_SU_April1.html Sun Internal and Approved Partners Only 67
  • 68. Reference Information • T5440 Engineering TOI – http://ittdev.east.sun.com/TechTalk2/EngineeringTOIs/ • ILOM/ALOM User Guides – http://www.sun.com/products-n-solutions/hardware/docs/pdf/819-1160-13.pdf – http://www.sun.com/products-n-solutions/hardware/docs/pdf/819-7981-10.pdf • Solaris FMA – http://fma.eng – http://lightside.sfbay/n2-fma/docs.php • Sun Internal and Approved Partners Only 68
  • 70. T5x40 PCI Topology Sun Internal and Approved Partners Only 70
  • 71. 10GbE Networking Substantiation 10GbE price for 2 x SR-fiber PCI-E adaptors = $6,740. From HP DL380G5 pricing on HP Store, www.hp.com, 12/17/07. Cost for 2 x 10GbE and SR transceivers for Maramba and Batoka are $1,800. From sun.com, 12/17/07 Sun Internal and Approved Partners Only 71