Gauges are often the sole source of data on critical equipment such as pumps. Learn how to detect issues in your process or with your equipment using local pressure indicators.
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
5 Ways to Troubleshoot Critical Equipment with Gauges
1. 1 DISCHARGE PRESSURE
Problem: Poor Pump Performance
Is the Pump Damaged? Process Off-Spec?
Problem: Mechanical Seal Failure
Is the Seal Receiving Adequate Cooling? Lubrication?
Is pressure reading
at design?
4 PRIMARY FLUSH PRESSURE
15-30 psig higher than
suction pressure?
SECONDARY FLUSH
PRESSURE
5
30 psig higher than
primary flush pressure?
2 SUCTION PRESSURE
Is suction pressure
reading at design?
3 SUPPLY PRESSURE
Strainer clogged, or other
upstream process issues.
Efficiency is
reduced from
internal wear
to pump.
Pressure not
adequate to
maintain cool,
clean seal
chamber -
grit & heat
accelerate
wear.
Barrier contamination
& accelerated seal face
wear possible from
low set pressure.
YES
NO NO
NO NO
5 Ways Gauges Help Troubleshoot Critical Equipment