1. Demonstration Thermography report
Company Testo Ltd Tester:
Newman Lane Andy McGrath - Testo
Alton, GU34 2QJ Phone: 01420 544433
E-Mail: info@testo.co.uk
Device Testo 880-3, 875-2 & 881-3 Serial No.: 1434423, 01729604 &
01710401
Lens: 32 degree, Wide Angle
Lens
Customer Testo Ltd Measuring Site:
Testo Thermal Imaging Demonstration Thermography Report
Cameras Various Applications for Testo Thermal
Demo Report Imaging cameras in HVAC.
Measuring Date: Various
Task Demonstration Thermography Report to highlight the capabilities of the
Testo Thermal Imaging cameras for various applications associated to
HVAC.
Page 1/15
2. Demonstration Thermography report
File: Date: Measuring Time:
IV_00518.BMT 14/01/2009 12:57:02
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 20.7 0.95 20.0 Spot Temp 1 to indicate
temperature variation across the
floor
Measure point 2 30.0 0.95 20.0 Spot Temp 2 to indicate
temperature variation across the
floor
Measure point 3 30.9 0.95 20.0 Spot Temp 3 to indicate
temperature variation across the
floor
Measure point 4 23.3 0.95 20.0 Spot Temp 4 to indicate
temperature variation across the
floor
Profile line:
Remarks:
Thermal Survey, specifically in a Utility Room for Trace and Access application.Thermal and Digital images
of Floor area taken as part of an investigation for possible leaks. Thermal image highlights temperature
variation across the floor, this is therefore an indication of the location of the heating pipework under the
floor.
Page 2/15
3. Demonstration Thermography report
File: Date: Measuring Time:
IV_00662.BMT 09/04/2009 08:27:40
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 19.7 0.95 20.0 -
Measure point 2 22.5 0.95 20.0 -
Measure point 3 19.2 0.95 20.0 -
Profile line:
Remarks:
Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of an
investigation for possible leaks. Thermal image highlights temperature variation across the floor, this is
therefore an indication of the location of the heating pipework under the floor.Spot temperature markers
highlight temperature difference across floor where heating pipework is located.
Page 3/15
4. Demonstration Thermography report
File: Date: Measuring Time:
IV_00663.BMT 09/04/2009 08:28:15
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 20.9 0.95 20.0 -
Measure point 2 23.5 0.95 20.0 -
Measure point 3 20.6 0.95 20.0 -
Profile line:
Remarks:
Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of an
investigation for possible leaks. Thermal image highlights temperature variation across the floor, this is
therefore an indication of the location of the heating pipework under the floor.Spot temperature markers
highlight temperature difference across floor where heating pipework is located.
Page 4/15
5. Demonstration Thermography report
File: Date: Measuring Time:
IV_00383.BMT 08/12/2008 13:26:37
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 17.6 0.95 20.0 Spot Temp 1 on Tiled Floor
adjacent to radiator
Measure point 2 16.9 0.95 20.0 Spot Temp 2 on Tiled Floor
adjacent to end of Skirting board
Measure point 3 16.6 0.95 20.0 Spot Temp 3 on Tiled Floor next
to glazed section
Measure point 4 14.3 0.95 20.0 Spot Temp 4 on Tiled floor area
away from where the hot water
pipes are located
Measure point 5 14.2 0.95 20.0 Spot Temp 5 on Tiled floor area
away from where the hot water
pipes are located
Profile line:
Remarks:
Demonstration Thermal survey conducted with Testo 880 series Thermal Imaging camera. Conducted in
Glazed walkway between Lounge and Kitchen extension.
The homeowner is complaining of possible water leak under the tiled floor. At the time that this Thermal and
Digital image were taken, the heat pattern effect from the hot water pipes under the floor were able to be
seen in the the Thermal image, travelling the length of the walkway but no anomaly is apparent at this stage.
Spot Temperatures have been added to the image to indicate the temperatures along the path of the pipes.
A temperature profile line graph has been added to the thermal image, to highlight the temperature variation
across the tiled floor.
Page 5/15
6. Demonstration Thermography report
File: Date: Measuring Time:
IV_00386.BMT 08/12/2008 13:32:32
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 18.1 0.95 20.0 Spot Temp 1 to indicate
temperature variation across the
floor
Measure point 2 18.4 0.95 20.0 Spot Temp 2 to indicate
temperature variation across the
floor
Measure point 3 15.7 0.95 20.0 Spot Temp 3 to indicate
temperature variation across the
floor
Measure point 4 14.9 0.95 20.0 Spot Temp 4 to indicate
temperature variation across the
floor
Hot spot 1 21.0 0.95 20.0 HS1 Hottest point on Thermal
Image
Profile line:
Remarks:
Thermal survey conducted with Testo 880 series Thermal Imaging camera for Trace and Access application.
In Glazed walkway between Lounge and Kitchen extension. The homeowner is complaining of possible
water leak under the tiled floor. The Thermal image shows the heat pattern effect from the heating pipes
under the floor, travelling the length of the walkway and now a hot spot can be seen clearly. This is an
indication of an anomaly, a possible leak from the central Heating system. The temperature in this area has
increased and is indicating an anomaly that requires investigation.
Page 6/15
7. Demonstration Thermography report
File: Date: Measuring Time:
IV_00585.BMT 10/03/2009 16:15:17
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 22.8 0.95 20.0 Spot Temp 1 for temperature
comparison.
Measure point 2 15.5 0.95 20.0 Spot Temp 2 for temperature
comparison.
Measure point 3 15.0 0.95 20.0 Spot Temp 3 for temperature
comparison.
Measure point 4 23.4 0.95 20.0 Spot Temp 4 for temperature
comparison.
Measure point 5 26.2 0.95 20.0 Spot Temp 5 for temperature
comparison.
Profile line:
Remarks:
Thermal and Digital images of a domestic radiator.
Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and the
Testo IR software.
Spot temperature markers have been added to show the temperature variation across the radiator. A
temperature profile line graph has also been added to visually show the temperature profile across the raditor
vertically.
Page 7/15
8. Demonstration Thermography report
File: Date: Measuring Time:
IV_00596.BMT 10/03/2009 16:21:02
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 29.7 0.95 20.0 Spot Temp 1 for temperature
comparison.
Measure point 2 26.0 0.95 20.0 Spot Temp 2 for temperature
comparison.
Measure point 3 20.5 0.95 20.0 Spot Temp 3 for temperature
comparison.
Profile line:
Remarks:
Thermal and Digital images of a domestic radiator.
Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and the
Testo IR software.
Spot temperature markers have been added to show the temperature variation across the radiator. A
temperature profile line graph has also been added to visually show the temperature profile across the raditor
diagonally. The palette has been changed to Hot/Cold.
Page 8/15
9. Demonstration Thermography report
File: Date: Measuring Time:
IV_00601.BMT 10/03/2009 16:24:10
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 31.2 0.95 20.0 -
Measure point 2 27.6 0.95 20.0 -
Measure point 3 22.0 0.95 20.0 -
Measure point 4 39.0 0.95 20.0 -
Histogram:
Profile line:
Remarks:
Thermal and Digital images of a domestic radiator.
Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and the
Testo IR software.
Additional spot temperature markers have been added to show the temperature variation across the radiator.
A temperature profile line graph has also been added to visually show the temperature profile across the
raditor diagonally. A Histogram has also been applied to the thermal image which defines the number of
temperature points at specific temperatures within a defined area.
Page 9/15
10. Demonstration Thermography report
File: Date: Measuring Time:
IV_00537.BMT 29/01/2009 10:58:15
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 29.5 0.95 20.0 Spot Temp 1 indicates Floor
temperature above the coil
Measure point 2 29.4 0.95 20.0 Spot Temp 2 indicates Floor
temperature above the coil
Measure point 3 22.7 0.95 20.0 Spot Temp 3, indicates the floor
temperature at section where
there is no heating coil
Measure point 4 28.9 0.95 20.0 Spot Temp 4 indicates Floor
temperature above the coil
Measure point 5 29.1 0.95 20.0 Spot Temp 5 indicates Floor
temperature above the coil
Measure point 6 24.8 0.95 20.0 Spot Temp 6, indicates the floor
temperature at section where
there is no heating coil
Measure point 7 30.0 0.95 20.0 Spot Temp 7 indicates Floor
temperature above the coil
Measure point 8 29.1 0.95 20.0 Spot Temp 8 indicates Floor
temperature above the coil
Measure point 9 24.5 0.95 20.0 Spot Temp 9, indicates the floor
temperature at section where
there is no heating coil
Hot spot 1 33.9 0.95 20.0 Auto Hot spot indicator
Page 10/15
11. Demonstration Thermography report
Profile line:
Remarks:
Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.
The Thermal image highlights the location of the underfloor heating coils.
A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures across
the underfloor heating coils.
Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.
The thermal image is shown in "Iron" palette.
Page 11/15
12. Demonstration Thermography report
File: Date: Measuring Time:
IV_00538.BMT 29/01/2009 10:58:30
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 34.8 0.95 20.0 -
Measure point 2 31.7 0.95 20.0 -
Measure point 3 35.0 0.95 20.0 -
Hot spot 1 39.1 0.95 20.0 -
Profile line:
Remarks:
Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.
The Thermal image highlights the underfloor heating coils.
The thermal image also has the auto Hot spot indicator applied to indicate automatically, the hottest point
"HS1" in the designated area.
A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures across
the underfloor heating coils.
Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.
The Thermal image is shown in "Iron" Palette.
Page 12/15
13. Demonstration Thermography report
File: Date: Measuring Time:
IV_01244.BMT 04/09/2009 17:37:00
Picture parameters:
Emissivity: 0.96
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 24.9 0.96 20.0 -
Measure point 2 44.4 0.96 20.0 -
Measure point 3 51.0 0.96 20.0 -
Measure point 4 43.4 0.96 20.0 -
Remarks:
Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water system,
Dual Pump for shower. Thermal image highlights temperature variation across the equipment and pipework,
Spot temperature markers highlight temperature difference in respect of the pipework and pump and indicate
which sections are operational.
Page 13/15
14. Demonstration Thermography report
File: Date: Measuring Time:
IV_01224.BMT 04/09/2009 16:45:34
Picture parameters:
Emissivity: 0.96
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 44.7 0.96 20.0 -
Hot spot 1 47.8 0.96 20.0 -
Profile line:
Remarks:
Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water Pump.
Thermal image highlights temperature variation across the equipment and pipework, Spot temperature
markers highlight temperature difference in respect of the pipework and pump and indicate which sections
are operational.
Review:
Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameraS and
the Testo IR software.
This is an example report for Demonstration purposes only. The format is the "Standard" report template from
the selection of Report Templates available in the software.
There are various subjects for the Thermal images and this report is compiled to indicate the capability of the
cameras and the software for a number of applications in the HVAC Industry.
Some of the features of the camera and software have been applied to the Thermal images.
Spot Temperature markers have been added to the thermal images to indicate temperatures.
Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point
Page 14/15
15. Demonstration Thermography report
Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point
in the defined area.
Temperature Profile Line Graph shows the temperature variation in graph form across the subject.
Palettes Various palettes (from the range available) have been used.
The images are automatically Time and Date Stamped to verify the time and date when the images were
taken.
The report also details the Emissivity value relating to the image taken.
25/09/2009 ,
Andy McGrath - Testo
Page 15/15