                        Introduction
sulaim_qais@yahoo.com                   February 2013


                        Overview FTTx
sulaim_qais@yahoo.com                                                          February 2013



     Malaysia is using single mode fiber with either 1310 nm or 1550 nm light signal
     depend on the distance. These lights are infrared light thus cannot be seen
     with naked eyes.




                                         Fusion splicing process is used to
                                         permanently join two fiber end
sulaim_qais@yahoo.com                                                                                          February 2013

                                                         TM UniFi
                                                                         All wireless adapter or device with standard
                                                                         (IEE802.11b/g/n) will work fine with wireless
                                                                         Residential Gateway (RG).




USB storage device can also be used as
share storage. This can be done by
connecting it to RG USB port .




 For RG detail configuration settings refer this site http://netops.tm.com.my/netops2/misc/TMRND%20RG%20Installation%20Guide%20R1.2.pdf
sulaim_qais@yahoo.com              February 2013

                        TM UniFi
sulaim_qais@yahoo.com                             February 2013


                        Building classification
sulaim_qais@yahoo.com                February 2013




             Single Dwelling Unit (SDU)
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                       February 2013


                         Indoor Fiber Cable Specification
      • Bend Insensitive Fiber ≤ 15mm bending radius
      • Macro Bending Loss, Maximum loss at 1550nm shall be 0.25dB and at
      1625nm shall be 1.0dB

      • Attenuation coefficient :
      i) Maximum 0.35 dB/km – from 1310nm to 1625nm regions.
      ii) Maximum 0.4 dB/km in the 1383nm ±3nm region.
      iii) Maximum 0.3 dB/km in the 1550nm region

      • tensile strength of the indoor cable shall be in excess of 80 N.
sulaim_qais@yahoo.com                                               February 2013

                        Fiber Termination Box (FTB)

                                  • FTB type approved by SIRIM
                                  • be suitable for 19” rack-mount and/or wall
                                  mounted
                                  • shall be complete with its respective mounting
                                  kits.
                                  • All edges shall be rounded
                                  • 1 SC/UPC (Standard Connector-Ultra Polish
                                  Connector)




  All conduits or cable enclosure need to be completely concealed
sulaim_qais@yahoo.com                                                          February 2013

                             Fiber Wall Socket (FWS)


                        provided by the developer with Standard Connector (SC)
                        output connector
                         Provided by the developer in all premises
                         Must be placed at 0.3m above the floor level and 0.3m
                        from the corner of the wall or from electrical points.
                         made from the non-corrosive material or treated metallic
                        material to resist corrosion placed adjacent to the electrical
                        power socket.
                         Recommend 2 AC power outlet min 1 near FWS
                         1 SC/UPC (Standard Connector-Ultra Polish Connector)
sulaim_qais@yahoo.com                                                           February 2013




• trunking must be used to lay the cable between the FTB, located at the outside wall, and the
FWS located inside the premise.
• trunking bending radius must greater than 10 times of the trunking size
• must be made from PVC or harder type of conduit with minimum 19mm diameter
sulaim_qais@yahoo.com                                                       February 2013




• developer must provide manhole to the nearest NFP manhole before the NFP can lay their
cable.
• FTB to FWS total IL <1.5 (TM standard) , 1.52 (MCMC standard) dB
sulaim_qais@yahoo.com                                          February 2013

                                       Pole Drop cable




             Drop cable can be 1 or 2 core single mode fiber

    • Drop Fibre generally must not exceed 50m
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                      February 2013
                                   Underground Cable




   • Drop Fibre must be connected to the premise wall FTB and at the other side it
   must be coiled inside the manhole and must be covered with end cap or terminate
   the fibre core inside the cable closure.
   • Drop Fibre generally must not exceed 50m
sulaim_qais@yahoo.com                                                  February 2013




        • FTB to FWS = IL <2.1 (TM Standard), 2.3 (MCMC standard) dB
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                           February 2013


      Manhole

     • Cover shall be made from fiber or any light material type which should be possible to
     be accessed by 1 person only
     • recommended size is JRC7 or JB30
     • be able to sustain up to 20 years
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                           February 2013

       Underground duct-ways
• required to connect the road side manhole to the
Telecommunication Room (TR) inside the building or direct to
the building
• should be build to accommodate the local line for 20 years
period in future expectation
• material of the duct shall be PVC or harder and must be
strong enough to protect the cable inside
• duct diameter must be minimum of 50 mm
• The duct routes must be as straight without sharp bends and
not obstructed.
• The maximum allowable bending radius is 20 times of duct
diameter.
• shall ensure that the constructed ducting system has a
minimal risk from the nature disaster including flood
• duct sectional length (manhole centre to manhole centre
distance) of 180m to 220m
sulaim_qais@yahoo.com                                                           February 2013




      • This design is applicable if the depth of the drain is less than 450mm (1.5
      feet)
      • small pit with minimum size 300mm X 300 mm X 300mm shall be prepared
      for easy access during the maintenance work
sulaim_qais@yahoo.com                                                      February 2013




      • depth of the drain is more than 450mm (1.5feet)
      • the duct must be protected by minimum 100mm of GI pipe to cover the duct from
      broken
sulaim_qais@yahoo.com                       February 2013




                        • meet ITU G.657A
sulaim_qais@yahoo.com               February 2013




                        Other SDU
sulaim_qais@yahoo.com                           February 2013


                            Other SDU example
                 Shop lot
sulaim_qais@yahoo.com                                                 February 2013




        Developer must provide a space minimum 600mm x 600mm beside FTB
sulaim_qais@yahoo.com                                          February 2013


                           Internal cable for building

Internal Fibre cable is used for corridor and indoor cabling




       • Single-Mode and meets specification ITU-T G.657A
sulaim_qais@yahoo.com                February 2013




              Multi Dwelling Unit (MDU)
sulaim_qais@yahoo.com                                February 2013

                                    MDU building
   Cabling for MDU consist of 4 elements as below:
   a.         Campus backbone cabling
   b.         Building backbone-vertical cable
   c.         Building horizontal cable
   d.        Telecommunication outlet cabling.
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                             February 2013


       • Number of effective core for each premise is two cores for business
       building and one core for residential building.

       • highly recommended to have minimum 30% spare cores for business and
       10% of spare core for residential building.

       •internal cabling must be tested and the result must be submitted to the
       NFP during the cabling approval process.

       •All the cable must be tested from point to point for every termination.

       •All the internal cabling for MDU must have a code or naming convention
       and tagged properly for easier maintenance and connection with NFP’s
       cable. All tag must be stated clearly and sealed with transparent material for
       easy to read.

       •All cables need to be inventoried and one copy of inventory information
       must be submitted to the NFP during the cabling approval process

       •Main hole at the road side until duct way into the building shall be provided
       by building owner
sulaim_qais@yahoo.com                                                           February 2013




code or naming convention for the Internal Vertical Cable must follow standard
as shown :
sulaim_qais@yahoo.com                                                          February 2013


                                 Horizontal cable
  horizontal cable is referred to the cabling between Floor Riser FTB to FWS inside each
  individualunit premise


                 The internal horizontal cable must be covered
                either
                a. Through ducting
                b. Concealed inside the wall
                c. Concealed underground floor
                c. using conduit through the ceiling
sulaim_qais@yahoo.com                                                  February 2013




    Network boundary 1 - Network Boundary between the NFP’s and the building
    management
    Network boundary 2 - Network Boundary between the building management and
    the individual customers
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                         February 2013

                        Riser Specification
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                          February 2013




• campus backbone cable and Internal Vertical Cable are normally same
• Cable type must be loose tube or ribbon single mode fibres with features comply with
G.652D or G.657A specification
sulaim_qais@yahoo.com                                                                February 2013


            Internal Horizontal Cable typically follows the specifications defined
            for distribution fibre and the type must single-mode fibre.
sulaim_qais@yahoo.com                                                         February 2013




      manhole, with minimum specification of JC9C size with 4 duct ways for
      connection to the nearest NFP’s manhole
sulaim_qais@yahoo.com                  February 2013

                        Cable trench
sulaim_qais@yahoo.com                                 February 2013

                         Telecommunication room
     house the service provider equipment and cable
sulaim_qais@yahoo.com   February 2013
sulaim_qais@yahoo.com                                                            February 2013

     • shall be provided with electrical AC supply from the utility supplies at a nominal
     of 415 V, 3 phase, 4 wires, 50 Hz system or at a nominal voltage of 240V AC Single-
     Phase system with solidly earth system.




  • shall be equipped with a 20A TPN metal clad Distribution Box (DB) of 20A
  • shall be equipped with daylight type fluorescent lighting that can provide a minimum of
  300 Lux luminance at floor level.
  • FTB must be located at the right most position as this is the nearest point leading to the
  internal riser NFP’s network elements will be located adjacent to the FTB
sulaim_qais@yahoo.com                                                         February 2013




         Insertion Loss (IL) FTB inside Telecommunication room, to FWS inside each
         individual premise must not exceed 2.2 dB.

Weitere ähnliche Inhalte

Was ist angesagt?

35992488 gpon-fundamentals-20070606-a
35992488 gpon-fundamentals-20070606-a35992488 gpon-fundamentals-20070606-a
35992488 gpon-fundamentals-20070606-a
Truong_RFD
 
FIBER OPTIC CABLE
FIBER OPTIC CABLEFIBER OPTIC CABLE
FIBER OPTIC CABLE
Man Mat
 
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Bruno Teixeira
 
Pemasangan sistem rangkaian komputer
Pemasangan sistem rangkaian komputerPemasangan sistem rangkaian komputer
Pemasangan sistem rangkaian komputer
nurnabila28
 
FTTX with Passive Optical Networks
FTTX with Passive Optical NetworksFTTX with Passive Optical Networks
FTTX with Passive Optical Networks
Anuradha Udunuwara
 
Passive Optical LAN Solution - White Paper
Passive Optical LAN Solution - White PaperPassive Optical LAN Solution - White Paper
Passive Optical LAN Solution - White Paper
Syed Firas
 

Was ist angesagt? (20)

Fttx ftth cabling system
Fttx ftth cabling systemFttx ftth cabling system
Fttx ftth cabling system
 
35992488 gpon-fundamentals-20070606-a
35992488 gpon-fundamentals-20070606-a35992488 gpon-fundamentals-20070606-a
35992488 gpon-fundamentals-20070606-a
 
OFC Trenching
OFC TrenchingOFC Trenching
OFC Trenching
 
FIBER OPTIC CABLE
FIBER OPTIC CABLEFIBER OPTIC CABLE
FIBER OPTIC CABLE
 
Coaxial Cable
Coaxial CableCoaxial Cable
Coaxial Cable
 
Fttx planning and design
Fttx planning and designFttx planning and design
Fttx planning and design
 
Passive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overviewPassive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overview
 
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
 
5G Enablers for new network
5G Enablers for new network5G Enablers for new network
5G Enablers for new network
 
Nota abc kabel 1
Nota abc kabel 1Nota abc kabel 1
Nota abc kabel 1
 
Optical fiber Communication training ppt
Optical fiber Communication training pptOptical fiber Communication training ppt
Optical fiber Communication training ppt
 
FTTH Basics
FTTH BasicsFTTH Basics
FTTH Basics
 
Pemasangan sistem rangkaian komputer
Pemasangan sistem rangkaian komputerPemasangan sistem rangkaian komputer
Pemasangan sistem rangkaian komputer
 
GPON-Fundamentals_Huawei.pdf
GPON-Fundamentals_Huawei.pdfGPON-Fundamentals_Huawei.pdf
GPON-Fundamentals_Huawei.pdf
 
FTTx Basics & Its Network Basics
FTTx Basics & Its Network BasicsFTTx Basics & Its Network Basics
FTTx Basics & Its Network Basics
 
GPON
GPONGPON
GPON
 
FTTX with Passive Optical Networks
FTTX with Passive Optical NetworksFTTX with Passive Optical Networks
FTTX with Passive Optical Networks
 
Passive Optical LAN Solution - White Paper
Passive Optical LAN Solution - White PaperPassive Optical LAN Solution - White Paper
Passive Optical LAN Solution - White Paper
 
GPON Introduction
GPON IntroductionGPON Introduction
GPON Introduction
 
Bluetooth
BluetoothBluetooth
Bluetooth
 

Andere mochten auch

Trien khai volktek ftth o vnpt
Trien khai volktek ftth o vnptTrien khai volktek ftth o vnpt
Trien khai volktek ftth o vnpt
BaoKhanhCorp
 
Micro trenching services by t.t ehsan sdn bhd
Micro trenching services by t.t ehsan sdn bhdMicro trenching services by t.t ehsan sdn bhd
Micro trenching services by t.t ehsan sdn bhd
T.T EHSAN SDN BHD
 

Andere mochten auch (15)

Awt Uvcw Communes Et Haut DéBit
Awt Uvcw Communes Et Haut DéBitAwt Uvcw Communes Et Haut DéBit
Awt Uvcw Communes Et Haut DéBit
 
Trien khai volktek ftth o vnpt
Trien khai volktek ftth o vnptTrien khai volktek ftth o vnpt
Trien khai volktek ftth o vnpt
 
Traps and manhole aditya kumar barn1 ar14002
Traps and manhole aditya kumar barn1 ar14002Traps and manhole aditya kumar barn1 ar14002
Traps and manhole aditya kumar barn1 ar14002
 
FTTB build out overview
FTTB build out overviewFTTB build out overview
FTTB build out overview
 
Quality in fttx deployments
Quality in fttx deploymentsQuality in fttx deployments
Quality in fttx deployments
 
Micro trenching services by t.t ehsan sdn bhd
Micro trenching services by t.t ehsan sdn bhdMicro trenching services by t.t ehsan sdn bhd
Micro trenching services by t.t ehsan sdn bhd
 
Structured cabling
Structured cablingStructured cabling
Structured cabling
 
Automation of GIS for FTTx Networks
Automation of GIS for  FTTx NetworksAutomation of GIS for  FTTx Networks
Automation of GIS for FTTx Networks
 
Automated and Optimised FTTx Planning
Automated and Optimised FTTx PlanningAutomated and Optimised FTTx Planning
Automated and Optimised FTTx Planning
 
Take control of your FTTH network design
Take control of your FTTH network designTake control of your FTTH network design
Take control of your FTTH network design
 
Structured Cabling Technologies
Structured Cabling TechnologiesStructured Cabling Technologies
Structured Cabling Technologies
 
ALU GPON TRAINING 3
ALU GPON TRAINING 3ALU GPON TRAINING 3
ALU GPON TRAINING 3
 
Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2
 
ALU GPON TRAINING 1
ALU GPON TRAINING 1ALU GPON TRAINING 1
ALU GPON TRAINING 1
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentals
 

Ähnlich wie FTTx Malaysia Standard

Tai lieu tong quan antena
Tai lieu tong quan antenaTai lieu tong quan antena
Tai lieu tong quan antena
Van Kiem Nguyen
 
3m-clear-solutions-for-ftth-white-paper
3m-clear-solutions-for-ftth-white-paper3m-clear-solutions-for-ftth-white-paper
3m-clear-solutions-for-ftth-white-paper
John Sherard
 
Gm Brand Rex Greek 2009 Optical
Gm Brand Rex Greek  2009 OpticalGm Brand Rex Greek  2009 Optical
Gm Brand Rex Greek 2009 Optical
Gianluca Musetti
 
passive-optical-lan-solutions-brochure
passive-optical-lan-solutions-brochurepassive-optical-lan-solutions-brochure
passive-optical-lan-solutions-brochure
Moin Sabri
 

Ähnlich wie FTTx Malaysia Standard (20)

Tai lieu tong quan antena
Tai lieu tong quan antenaTai lieu tong quan antena
Tai lieu tong quan antena
 
3m-clear-solutions-for-ftth-white-paper
3m-clear-solutions-for-ftth-white-paper3m-clear-solutions-for-ftth-white-paper
3m-clear-solutions-for-ftth-white-paper
 
Mecatraction - SOLFIL+ Earthing Clamps
Mecatraction - SOLFIL+ Earthing Clamps Mecatraction - SOLFIL+ Earthing Clamps
Mecatraction - SOLFIL+ Earthing Clamps
 
Cable Installation 2013
Cable Installation 2013Cable Installation 2013
Cable Installation 2013
 
unit4domesticwiringandinstruments-220608154915-ac268fee.pdf
unit4domesticwiringandinstruments-220608154915-ac268fee.pdfunit4domesticwiringandinstruments-220608154915-ac268fee.pdf
unit4domesticwiringandinstruments-220608154915-ac268fee.pdf
 
unit 4 domestic wiring and instruments.pptx
unit 4 domestic wiring and instruments.pptxunit 4 domestic wiring and instruments.pptx
unit 4 domestic wiring and instruments.pptx
 
An Introduction to HDTV Principles-Part 4
An Introduction to HDTV Principles-Part 4An Introduction to HDTV Principles-Part 4
An Introduction to HDTV Principles-Part 4
 
Nestor Cables Solutions
Nestor Cables SolutionsNestor Cables Solutions
Nestor Cables Solutions
 
ITU Bending.pdf
ITU Bending.pdfITU Bending.pdf
ITU Bending.pdf
 
IDS Cable Ducting, Cable Chambers & Vaults
IDS Cable Ducting, Cable Chambers & VaultsIDS Cable Ducting, Cable Chambers & Vaults
IDS Cable Ducting, Cable Chambers & Vaults
 
Presentation of optical fiber connector
Presentation of optical fiber connectorPresentation of optical fiber connector
Presentation of optical fiber connector
 
Gm Brand Rex Greek 2009 Optical
Gm Brand Rex Greek  2009 OpticalGm Brand Rex Greek  2009 Optical
Gm Brand Rex Greek 2009 Optical
 
Sam cables presentation
Sam cables presentation Sam cables presentation
Sam cables presentation
 
Cybersecurity- 2017 R1.pptx
 Cybersecurity- 2017 R1.pptx Cybersecurity- 2017 R1.pptx
Cybersecurity- 2017 R1.pptx
 
1-3-Design and Implementation of Fiber Optics In Buildings - Dr. Omar Rawda
1-3-Design and Implementation of Fiber Optics In Buildings - Dr. Omar Rawda1-3-Design and Implementation of Fiber Optics In Buildings - Dr. Omar Rawda
1-3-Design and Implementation of Fiber Optics In Buildings - Dr. Omar Rawda
 
Design and Implementation of fibre optics in-buildings; Standards, Legislatio...
Design and Implementation of fibre optics in-buildings; Standards, Legislatio...Design and Implementation of fibre optics in-buildings; Standards, Legislatio...
Design and Implementation of fibre optics in-buildings; Standards, Legislatio...
 
C5 wimes and spd, david bray
C5 wimes and spd, david brayC5 wimes and spd, david bray
C5 wimes and spd, david bray
 
Fiber optics 2-1
Fiber optics 2-1Fiber optics 2-1
Fiber optics 2-1
 
passive-optical-lan-solutions-brochure
passive-optical-lan-solutions-brochurepassive-optical-lan-solutions-brochure
passive-optical-lan-solutions-brochure
 
TiniFiber - An Armored Fiber Innovation
TiniFiber - An Armored Fiber InnovationTiniFiber - An Armored Fiber Innovation
TiniFiber - An Armored Fiber Innovation
 

Mehr von sulaim_qais (10)

2018867974 sulaim (2)
2018867974 sulaim (2)2018867974 sulaim (2)
2018867974 sulaim (2)
 
38 GHz rectangular patch antenna CST
38 GHz rectangular patch antenna CST38 GHz rectangular patch antenna CST
38 GHz rectangular patch antenna CST
 
Super heterodyne
Super heterodyneSuper heterodyne
Super heterodyne
 
Phase lock loop (pll)
Phase lock loop (pll)Phase lock loop (pll)
Phase lock loop (pll)
 
Notes about Lynas advanced material plan (lamp)
Notes about Lynas advanced material plan (lamp)Notes about Lynas advanced material plan (lamp)
Notes about Lynas advanced material plan (lamp)
 
Something about Antenna design
Something about Antenna designSomething about Antenna design
Something about Antenna design
 
Rectangular patch Antenna
Rectangular patch AntennaRectangular patch Antenna
Rectangular patch Antenna
 
Transformer design
Transformer designTransformer design
Transformer design
 
Malaysia Television services
Malaysia Television servicesMalaysia Television services
Malaysia Television services
 
Fiber Optic Termination
Fiber Optic TerminationFiber Optic Termination
Fiber Optic Termination
 

Kürzlich hochgeladen

+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Kürzlich hochgeladen (20)

Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 

FTTx Malaysia Standard

  • 1. sulaim_qais@yahoo.com February 2013 Fiber to The x (FTTx) Malaysia Installation Standard
  • 2. sulaim_qais@yahoo.com February 2013 Introduction
  • 3. sulaim_qais@yahoo.com February 2013 Overview FTTx
  • 4. sulaim_qais@yahoo.com February 2013 Malaysia is using single mode fiber with either 1310 nm or 1550 nm light signal depend on the distance. These lights are infrared light thus cannot be seen with naked eyes. Fusion splicing process is used to permanently join two fiber end
  • 5. sulaim_qais@yahoo.com February 2013 TM UniFi All wireless adapter or device with standard (IEE802.11b/g/n) will work fine with wireless Residential Gateway (RG). USB storage device can also be used as share storage. This can be done by connecting it to RG USB port . For RG detail configuration settings refer this site http://netops.tm.com.my/netops2/misc/TMRND%20RG%20Installation%20Guide%20R1.2.pdf
  • 6. sulaim_qais@yahoo.com February 2013 TM UniFi
  • 7. sulaim_qais@yahoo.com February 2013 Building classification
  • 8. sulaim_qais@yahoo.com February 2013 Single Dwelling Unit (SDU)
  • 9. sulaim_qais@yahoo.com February 2013
  • 10. sulaim_qais@yahoo.com February 2013 Indoor Fiber Cable Specification • Bend Insensitive Fiber ≤ 15mm bending radius • Macro Bending Loss, Maximum loss at 1550nm shall be 0.25dB and at 1625nm shall be 1.0dB • Attenuation coefficient : i) Maximum 0.35 dB/km – from 1310nm to 1625nm regions. ii) Maximum 0.4 dB/km in the 1383nm ±3nm region. iii) Maximum 0.3 dB/km in the 1550nm region • tensile strength of the indoor cable shall be in excess of 80 N.
  • 11. sulaim_qais@yahoo.com February 2013 Fiber Termination Box (FTB) • FTB type approved by SIRIM • be suitable for 19” rack-mount and/or wall mounted • shall be complete with its respective mounting kits. • All edges shall be rounded • 1 SC/UPC (Standard Connector-Ultra Polish Connector) All conduits or cable enclosure need to be completely concealed
  • 12. sulaim_qais@yahoo.com February 2013 Fiber Wall Socket (FWS) provided by the developer with Standard Connector (SC) output connector  Provided by the developer in all premises  Must be placed at 0.3m above the floor level and 0.3m from the corner of the wall or from electrical points.  made from the non-corrosive material or treated metallic material to resist corrosion placed adjacent to the electrical power socket.  Recommend 2 AC power outlet min 1 near FWS  1 SC/UPC (Standard Connector-Ultra Polish Connector)
  • 13. sulaim_qais@yahoo.com February 2013 • trunking must be used to lay the cable between the FTB, located at the outside wall, and the FWS located inside the premise. • trunking bending radius must greater than 10 times of the trunking size • must be made from PVC or harder type of conduit with minimum 19mm diameter
  • 14. sulaim_qais@yahoo.com February 2013 • developer must provide manhole to the nearest NFP manhole before the NFP can lay their cable. • FTB to FWS total IL <1.5 (TM standard) , 1.52 (MCMC standard) dB
  • 15. sulaim_qais@yahoo.com February 2013 Pole Drop cable Drop cable can be 1 or 2 core single mode fiber • Drop Fibre generally must not exceed 50m
  • 16. sulaim_qais@yahoo.com February 2013
  • 17. sulaim_qais@yahoo.com February 2013 Underground Cable • Drop Fibre must be connected to the premise wall FTB and at the other side it must be coiled inside the manhole and must be covered with end cap or terminate the fibre core inside the cable closure. • Drop Fibre generally must not exceed 50m
  • 18. sulaim_qais@yahoo.com February 2013 • FTB to FWS = IL <2.1 (TM Standard), 2.3 (MCMC standard) dB
  • 19. sulaim_qais@yahoo.com February 2013
  • 20. sulaim_qais@yahoo.com February 2013 Manhole • Cover shall be made from fiber or any light material type which should be possible to be accessed by 1 person only • recommended size is JRC7 or JB30 • be able to sustain up to 20 years
  • 21. sulaim_qais@yahoo.com February 2013
  • 22. sulaim_qais@yahoo.com February 2013 Underground duct-ways • required to connect the road side manhole to the Telecommunication Room (TR) inside the building or direct to the building • should be build to accommodate the local line for 20 years period in future expectation • material of the duct shall be PVC or harder and must be strong enough to protect the cable inside • duct diameter must be minimum of 50 mm • The duct routes must be as straight without sharp bends and not obstructed. • The maximum allowable bending radius is 20 times of duct diameter. • shall ensure that the constructed ducting system has a minimal risk from the nature disaster including flood • duct sectional length (manhole centre to manhole centre distance) of 180m to 220m
  • 23. sulaim_qais@yahoo.com February 2013 • This design is applicable if the depth of the drain is less than 450mm (1.5 feet) • small pit with minimum size 300mm X 300 mm X 300mm shall be prepared for easy access during the maintenance work
  • 24. sulaim_qais@yahoo.com February 2013 • depth of the drain is more than 450mm (1.5feet) • the duct must be protected by minimum 100mm of GI pipe to cover the duct from broken
  • 25. sulaim_qais@yahoo.com February 2013 • meet ITU G.657A
  • 26. sulaim_qais@yahoo.com February 2013 Other SDU
  • 27. sulaim_qais@yahoo.com February 2013 Other SDU example Shop lot
  • 28. sulaim_qais@yahoo.com February 2013 Developer must provide a space minimum 600mm x 600mm beside FTB
  • 29. sulaim_qais@yahoo.com February 2013 Internal cable for building Internal Fibre cable is used for corridor and indoor cabling • Single-Mode and meets specification ITU-T G.657A
  • 30. sulaim_qais@yahoo.com February 2013 Multi Dwelling Unit (MDU)
  • 31. sulaim_qais@yahoo.com February 2013 MDU building Cabling for MDU consist of 4 elements as below: a. Campus backbone cabling b. Building backbone-vertical cable c. Building horizontal cable d. Telecommunication outlet cabling.
  • 32. sulaim_qais@yahoo.com February 2013
  • 33. sulaim_qais@yahoo.com February 2013 • Number of effective core for each premise is two cores for business building and one core for residential building. • highly recommended to have minimum 30% spare cores for business and 10% of spare core for residential building. •internal cabling must be tested and the result must be submitted to the NFP during the cabling approval process. •All the cable must be tested from point to point for every termination. •All the internal cabling for MDU must have a code or naming convention and tagged properly for easier maintenance and connection with NFP’s cable. All tag must be stated clearly and sealed with transparent material for easy to read. •All cables need to be inventoried and one copy of inventory information must be submitted to the NFP during the cabling approval process •Main hole at the road side until duct way into the building shall be provided by building owner
  • 34. sulaim_qais@yahoo.com February 2013 code or naming convention for the Internal Vertical Cable must follow standard as shown :
  • 35. sulaim_qais@yahoo.com February 2013 Horizontal cable horizontal cable is referred to the cabling between Floor Riser FTB to FWS inside each individualunit premise The internal horizontal cable must be covered either a. Through ducting b. Concealed inside the wall c. Concealed underground floor c. using conduit through the ceiling
  • 36. sulaim_qais@yahoo.com February 2013 Network boundary 1 - Network Boundary between the NFP’s and the building management Network boundary 2 - Network Boundary between the building management and the individual customers
  • 37. sulaim_qais@yahoo.com February 2013
  • 38. sulaim_qais@yahoo.com February 2013 Riser Specification
  • 39. sulaim_qais@yahoo.com February 2013
  • 40. sulaim_qais@yahoo.com February 2013
  • 41. sulaim_qais@yahoo.com February 2013 • campus backbone cable and Internal Vertical Cable are normally same • Cable type must be loose tube or ribbon single mode fibres with features comply with G.652D or G.657A specification
  • 42. sulaim_qais@yahoo.com February 2013 Internal Horizontal Cable typically follows the specifications defined for distribution fibre and the type must single-mode fibre.
  • 43.
  • 44. sulaim_qais@yahoo.com February 2013 manhole, with minimum specification of JC9C size with 4 duct ways for connection to the nearest NFP’s manhole
  • 45. sulaim_qais@yahoo.com February 2013 Cable trench
  • 46. sulaim_qais@yahoo.com February 2013 Telecommunication room house the service provider equipment and cable
  • 47. sulaim_qais@yahoo.com February 2013
  • 48. sulaim_qais@yahoo.com February 2013 • shall be provided with electrical AC supply from the utility supplies at a nominal of 415 V, 3 phase, 4 wires, 50 Hz system or at a nominal voltage of 240V AC Single- Phase system with solidly earth system. • shall be equipped with a 20A TPN metal clad Distribution Box (DB) of 20A • shall be equipped with daylight type fluorescent lighting that can provide a minimum of 300 Lux luminance at floor level. • FTB must be located at the right most position as this is the nearest point leading to the internal riser NFP’s network elements will be located adjacent to the FTB
  • 49. sulaim_qais@yahoo.com February 2013 Insertion Loss (IL) FTB inside Telecommunication room, to FWS inside each individual premise must not exceed 2.2 dB.