D E LTA
Cooling Towers, Inc.




            Delta Cooling Towers
        Leader in Non-Corrosive Cooling Tower Technology
options
                                                                accessories


Standard Features                   Options

- HDPE Shell                        - Thermostatic Fan
- Corrosion-Proof Construction        On-Off Control
- Non-Clog PVC Water                - Ladders with Landing
  Distribution System                 Platforms
- High Energy Efficiency            - Pumps
- Totally Enclosed Cooling          - Control Panels
  Tower Motors                      - Indoor Storage Tanks
- PVC Fittings                      - Anti-Freeze Control
                                      Sump Packages




EXPERIENCE
Since 1970 Delta has provided cooling towers that stand
                                                                                                       •
up to process conditions and the outdoor elements like
no other cooling tower. Delta has coupled the
maintenance-free seamless plastic construction with                   30 Years of Cooling Tower
many other design features consistent with trouble-free               Manufacturing Experience
longevity. The unitary plastic shell of the tower carries the
industry best 15 Year Warranty.

CUSTOMIZE YOUR COOLING TOWER
Do you have any special requirements for your cooling
                                                                                                       •
tower - fitting locations, bottom outlets, gravity drain,
oversized fittings, pump suction, high temperatures, space
restrictions? Delta has a “Can-Do” orientation and we would               You decide how you
be glad to talk through your unique requirements and                     want your Delta Tower
provide the best solution for your application.

ONE-SOURCE RESPONSIBILITY
Delta has application engineers that can assist you in
                                                                           Let Delta supply your
                                                                                                       •
providing all the elements of a complete process cooling
                                                                               Complete System
system. Some of these items are listed below.
 - Plate & Frame Heat             - Control Panels
   Exchangers
                                  - Water Storage Tanks
 - Pre-Piped, Pre-Wired
                                  - Pumps
   Pump Stations
                                  - Closed Loop Cooling
 - Strainers and other Filters
                                    Systems                                               Member CTI
PIONEER®
                                                                      Forced Draft Cooling Towers
                                                                    10 to 400 ton cooling systems


CORROSION-                                                                                                                      DRIFT
PROOF SHELL                                                                                                                     ELIMINATOR
HDPE Plastic                                                                                                                    PVC drift eliminator
Construction can not                                                                                                            prevents water droplets
corrode and is                                                                                                                  from leaving the tower.
backed by 15 Year
Warranty.
                                                                                    •

LIGHTWEIGHT                          •                         •                                                                NOZZLE WATER
AND HEAVY                                                                                                                       DISTRIBUTION
DUTY                                                                 •                                                          SYSTEM
Plastic is lighter than                                                                                                         Non-Clog large orifice
conventional cooling                                                                                                            removable nozzles evenly
towers and average                                                                                                              distribute the water.
wall thickness is 5-10
times sheet metal
towers.                                  •
                                                                                                                  •
LEAK-PROOF
SUMP                                             •                                                                              AIR MOVING
                                                                                                                                SYSTEM
Molded as Unitary                                                                                                               Totally enclosed
(One-Piece) Structure                                                                                                           cooling tower motor
that has no joints to                                                                                                           powers centrifugal
leak or require re-                                        FILL MATERIAL                                                        blower with optional
caulking and sealing.                                                                                                           HDPE weather hood.
                                                           High efficiency spiral wound
                                                           PVC for maximum cooling.



  Model               Approximate Weight                      Dimensions            Capacity          Fan Motor          Sump Capacity
  Number              Shipping Operating                       Dia. x Ht.            Tons                HP                 Gallons
  ∆t-10                   350                705               38" x 78"                10                   1                    40
  ∆t-15                   360                725               38" x 78"                15                  1.5                   40
  ∆t-20                   385              750                 38" x 78"                20                   2                    40
  ∆t-25                   405                765               38" x 78"                25                   3                    40
  ∆t-30                   710             1500                 56" x 76"                30                   5                    75
  ∆t-40                   730             1525                 56" x 76"                40                   5                    75
  ∆t-50                   910             2610                 80" x 80"                50                   5                   157
  ∆t-75                   970             2675                 80" x 80"                75                  7.5                  157
  ∆t-100                 1030             2730                 80" x 80"                100                 10                   157
The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not,
in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
PARAGON®
                                                          Induced Draft Cooling Tower
                                                     100 to 1000 ton cooling systems


CORROSION-                                                                                                             DIRECT DRIVE
PROOF SHELL                                                                                                            AIR MOVING
HDPE Plastic                                                                          •                                SYSTEM
                                                                                                                       Totally enclosed cooling
Construction can not
corrode and is backed                                                                                                  tower motor powers
by 15 Year Warranty.                                                                                                   fiber-reinforced
                                                                                                                       polypropylene axial
                                                                                                                       propeller fan.


                                                     •
                                                                           •                    •
LIGHTWEIGHT
                                                       •                                  •                             FILL MATERIAL
AND                                                                                                                     High efficiency spiral
HEAVY DUTY                                                                                                              wound PVC cellular
Plastic is lighter than                                                                                                 design for maximum
conventional cooling                                                                                                    cooling.
towers and average
wall thickness is 5-10
times sheet metal
towers.




LEAK-PROOF                                                                                                              DRIFT
SUMP                                                                                                                    ELIMINATOR
Molded as Unitary                                                                                                       Polyethylene drift
(One-Piece)                                                                                                             eliminators prevent
Structure that has
no joints to leak or                                     •                                                              water droplets from
                                                                                                                        leaving the tower.
require re-caulking
and sealing.


                                                    WATER DISTRIBUTION SYSTEM
                                                    Self-propelled multiple PVC rotating arm system
                                                    evenly distributes the water.



  Model                Approximate Weight                     Dimensions            Capacity          Fan Motor          Sump Capacity
  Number               Shipping Operating                      Dia. x Ht.            Tons                HP                 Gallons
  ∆T-100I                 1510            4235                84" x 146"               100                   5                   330
  ∆T-125I                 1585            4310                84" x 146"               125                  7.5                  330
  ∆T-150I                 1785             5570                95" x 178"              150                  7.5                  468
  ∆T-175I                 1925            5810                 95" x 178"              175                  10                   468
  ∆T-200I                 3170            8440                114" x 210"              200                  10                   718
  ∆T-250I                 3365            8640                114" x 210"              250                  15                   718
The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not,
in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
TM SERIES™
                                                         Induced Draft Cooling Towers
                                                     250 to 20000 ton cooling systems
   DIRECT DRIVE                          FILL MATERIAL                          NOZZLE WATER                               DRIFT
   AIR MOVING                                                                   DISTRIBUTION                               ELIMINATOR
                                         High efficiency PVC
   SYSTEM                                                                       SYSTEM                                     Three pass PVC drift
                                         cellular design for
   Totally enclosed cooling              maximum cooling.                       Non-Clog large orifice                     eliminator prevents
   tower motors power                                                           removable nozzles evenly                   water droplets from
   multiple fiber-reinforced                                                    distribute the water.                      leaving the tower.
   polypropylene axial
   propeller fans within
   polyethylene velocity
   recovery stack.
                                •




                                 •                                                              •
                                                                                         •
                                                                                                      •
                                                                                 •
                                         •
                                                                 •
LIGHTWEIGHT                   LEAK-PROOF                   SELF                              CORROSION-                   INDEPENDENT
AND                           SUMP                         SUPPORTING                        PROOF SHELL                  CELL
DOUBLE-WALL                   Molded as Unitary            PLASTIC BASE                      HDPE Plastic                 CAPABILITY
Plastic is lighter than       (One-Piece) Structure        Tower can be set on flat          Construction can not         Independent Cells allow
conventional cooling          that has no joints to        surface or on I-Beams             corrode and is               isolation of cells for
towers and integrated         leak or require re-          placed in Integrally-             backed by 15 Year            operational flexibility.
double-wall is more           caulking and sealing.        Molded I-Beam Pockets             Warranty.
than 10 times the                                          for elevated installations.
average wall thickness
of metal towers.


     Model          Approximate Weight                    Dimensions                     Capacity          Fan Motor         Sump Capacity
     Group          Shipping Operating                    L x W x Ht.                     Tons                HP                Gallons
     1 Cell            5020           10670            16.5' x 8.5' x 15.5'              250-425              10-30                   480
     2 Cell           10040           21340            16.5' x 17.0' x 15.5'             460-820              20-60                   960
     3 Cell           15060           32010           16.5' x 25.5' x 16.5'             700-1200              30-90                  1400
     4 Cell           20080           42680           16.5' x 34.0' x 16.5'            910-1580              40-120                  1920
     5 Cell           25100           53350           16.5' x 42.5' x 16.5'            1120-1710             50-120                  2400
     6 Cell           30120           64020           16.5' x 51.0' x 16.5'            1340-2020             60-120                  2880
   The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not,
   in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
Delta Cooling Towers has made substantial investments in
manufacturing capabilities to provide the most trouble-free and longest lasting
cooling towers available.


      • Maintenance Free Unitarily Molded Leak-Proof Shell
      • High Density Polyethylene Casing Carries 15-Year Warranty
      • Perfect for Applications from the Routine to Extremely Corrosive
      • Factory Assembled for Simple Installation
      • Made In The USA - Consistent High Quality
      • 30 Years of Leadership in Non-Corrosive Cooling Tower Manufacturing




                    Delta Cooling Towers
        Leader in Non-Corrosive Cooling Tower Technology
                         134 Clinton Road, P.O. Box 952
                        Fairfield, New Jersey 07004-2970
            Tel: 973-227-0300 • Fax: 973-227-0458 • 800-BUY-DELTA
          E-mail: deltacooling@att.net • Website www.deltacooling.com

Weitere ähnliche Inhalte

Ähnlich wie Delta Cooling Tower

Soundown Yacht Presentation
Soundown Yacht PresentationSoundown Yacht Presentation
Soundown Yacht PresentationBovaMarine
 
JDWW001v6evapcocondenser
JDWW001v6evapcocondenserJDWW001v6evapcocondenser
JDWW001v6evapcocondenserKelly Erwin
 
CT turbosplash fill 190617
CT turbosplash  fill 190617 CT turbosplash  fill 190617
CT turbosplash fill 190617 tsi
 
Universal mag drive brochrue
Universal mag drive brochrueUniversal mag drive brochrue
Universal mag drive brochrueEko Kiswanto
 
Splicing theory & products
Splicing theory & productsSplicing theory & products
Splicing theory & productsmichaeljmack
 
Cooling tower
Cooling towerCooling tower
Cooling towerAshif AR
 
Aluminum pontoons for sale pontoons.com
Aluminum pontoons for sale  pontoons.comAluminum pontoons for sale  pontoons.com
Aluminum pontoons for sale pontoons.comJessica Tara
 
PacificValvesWedgeplugBrochureCV-408
PacificValvesWedgeplugBrochureCV-408PacificValvesWedgeplugBrochureCV-408
PacificValvesWedgeplugBrochureCV-408Dino Pedicelli
 
SPX Fills by He Bei RUIDE COOLINGTower Parts
SPX  Fills  by  He Bei RUIDE  COOLINGTower  Parts  SPX  Fills  by  He Bei RUIDE  COOLINGTower  Parts
SPX Fills by He Bei RUIDE COOLINGTower Parts Tim Yao
 
Polyflow Thermoflex Overview June 2012
Polyflow Thermoflex   Overview June 2012Polyflow Thermoflex   Overview June 2012
Polyflow Thermoflex Overview June 2012Polyflow Inc
 
Cooling tower BY G.DINESHPIRAN
Cooling tower BY G.DINESHPIRANCooling tower BY G.DINESHPIRAN
Cooling tower BY G.DINESHPIRANDinesh Piran-Gdp
 
Bicarbonator pressure blast_cabinet
Bicarbonator pressure blast_cabinetBicarbonator pressure blast_cabinet
Bicarbonator pressure blast_cabinetJane Smith
 
Universal seal brochure
Universal seal brochureUniversal seal brochure
Universal seal brochureEko Kiswanto
 
Cooling Tower Systems
 Cooling Tower Systems Cooling Tower Systems
Cooling Tower SystemsCoolingTower4
 
Subsea And Deepwater Flow Assurance Insulation Challenges And New Developmen...
Subsea And Deepwater Flow Assurance Insulation  Challenges And New Developmen...Subsea And Deepwater Flow Assurance Insulation  Challenges And New Developmen...
Subsea And Deepwater Flow Assurance Insulation Challenges And New Developmen...Shiwei William Guan
 
Bnp 250 260_wetblast_cabinets
Bnp 250 260_wetblast_cabinetsBnp 250 260_wetblast_cabinets
Bnp 250 260_wetblast_cabinetsJane Smith
 
How to Improve Steam Turbine Head Rate and Increase Output
How to Improve Steam Turbine Head Rate and Increase OutputHow to Improve Steam Turbine Head Rate and Increase Output
How to Improve Steam Turbine Head Rate and Increase OutputMargaret Harrison
 

Ähnlich wie Delta Cooling Tower (20)

Soundown Yacht Presentation
Soundown Yacht PresentationSoundown Yacht Presentation
Soundown Yacht Presentation
 
JDWW001v6evapcocondenser
JDWW001v6evapcocondenserJDWW001v6evapcocondenser
JDWW001v6evapcocondenser
 
CT turbosplash fill 190617
CT turbosplash  fill 190617 CT turbosplash  fill 190617
CT turbosplash fill 190617
 
Universal mag drive brochrue
Universal mag drive brochrueUniversal mag drive brochrue
Universal mag drive brochrue
 
Splicing theory & products
Splicing theory & productsSplicing theory & products
Splicing theory & products
 
Cooling tower
Cooling towerCooling tower
Cooling tower
 
Aluminum pontoons for sale pontoons.com
Aluminum pontoons for sale  pontoons.comAluminum pontoons for sale  pontoons.com
Aluminum pontoons for sale pontoons.com
 
PacificValvesWedgeplugBrochureCV-408
PacificValvesWedgeplugBrochureCV-408PacificValvesWedgeplugBrochureCV-408
PacificValvesWedgeplugBrochureCV-408
 
SPX Fills by He Bei RUIDE COOLINGTower Parts
SPX  Fills  by  He Bei RUIDE  COOLINGTower  Parts  SPX  Fills  by  He Bei RUIDE  COOLINGTower  Parts
SPX Fills by He Bei RUIDE COOLINGTower Parts
 
Polyflow Thermoflex Overview June 2012
Polyflow Thermoflex   Overview June 2012Polyflow Thermoflex   Overview June 2012
Polyflow Thermoflex Overview June 2012
 
Cooling tower BY G.DINESHPIRAN
Cooling tower BY G.DINESHPIRANCooling tower BY G.DINESHPIRAN
Cooling tower BY G.DINESHPIRAN
 
Bicarbonator pressure blast_cabinet
Bicarbonator pressure blast_cabinetBicarbonator pressure blast_cabinet
Bicarbonator pressure blast_cabinet
 
Product
ProductProduct
Product
 
Universal seal brochure
Universal seal brochureUniversal seal brochure
Universal seal brochure
 
INTRODUCING AQUAFAN
INTRODUCING AQUAFANINTRODUCING AQUAFAN
INTRODUCING AQUAFAN
 
Cooling Tower Systems
 Cooling Tower Systems Cooling Tower Systems
Cooling Tower Systems
 
Subsea And Deepwater Flow Assurance Insulation Challenges And New Developmen...
Subsea And Deepwater Flow Assurance Insulation  Challenges And New Developmen...Subsea And Deepwater Flow Assurance Insulation  Challenges And New Developmen...
Subsea And Deepwater Flow Assurance Insulation Challenges And New Developmen...
 
Bnp 250 260_wetblast_cabinets
Bnp 250 260_wetblast_cabinetsBnp 250 260_wetblast_cabinets
Bnp 250 260_wetblast_cabinets
 
SMG Permaseal Non Lubricated Tapered Plug Valve
SMG Permaseal Non Lubricated Tapered Plug ValveSMG Permaseal Non Lubricated Tapered Plug Valve
SMG Permaseal Non Lubricated Tapered Plug Valve
 
How to Improve Steam Turbine Head Rate and Increase Output
How to Improve Steam Turbine Head Rate and Increase OutputHow to Improve Steam Turbine Head Rate and Increase Output
How to Improve Steam Turbine Head Rate and Increase Output
 

Delta Cooling Tower

  • 1. D E LTA Cooling Towers, Inc. Delta Cooling Towers Leader in Non-Corrosive Cooling Tower Technology
  • 2. options accessories Standard Features Options - HDPE Shell - Thermostatic Fan - Corrosion-Proof Construction On-Off Control - Non-Clog PVC Water - Ladders with Landing Distribution System Platforms - High Energy Efficiency - Pumps - Totally Enclosed Cooling - Control Panels Tower Motors - Indoor Storage Tanks - PVC Fittings - Anti-Freeze Control Sump Packages EXPERIENCE Since 1970 Delta has provided cooling towers that stand • up to process conditions and the outdoor elements like no other cooling tower. Delta has coupled the maintenance-free seamless plastic construction with 30 Years of Cooling Tower many other design features consistent with trouble-free Manufacturing Experience longevity. The unitary plastic shell of the tower carries the industry best 15 Year Warranty. CUSTOMIZE YOUR COOLING TOWER Do you have any special requirements for your cooling • tower - fitting locations, bottom outlets, gravity drain, oversized fittings, pump suction, high temperatures, space restrictions? Delta has a “Can-Do” orientation and we would You decide how you be glad to talk through your unique requirements and want your Delta Tower provide the best solution for your application. ONE-SOURCE RESPONSIBILITY Delta has application engineers that can assist you in Let Delta supply your • providing all the elements of a complete process cooling Complete System system. Some of these items are listed below. - Plate & Frame Heat - Control Panels Exchangers - Water Storage Tanks - Pre-Piped, Pre-Wired - Pumps Pump Stations - Closed Loop Cooling - Strainers and other Filters Systems Member CTI
  • 3. PIONEER® Forced Draft Cooling Towers 10 to 400 ton cooling systems CORROSION- DRIFT PROOF SHELL ELIMINATOR HDPE Plastic PVC drift eliminator Construction can not prevents water droplets corrode and is from leaving the tower. backed by 15 Year Warranty. • LIGHTWEIGHT • • NOZZLE WATER AND HEAVY DISTRIBUTION DUTY • SYSTEM Plastic is lighter than Non-Clog large orifice conventional cooling removable nozzles evenly towers and average distribute the water. wall thickness is 5-10 times sheet metal towers. • • LEAK-PROOF SUMP • AIR MOVING SYSTEM Molded as Unitary Totally enclosed (One-Piece) Structure cooling tower motor that has no joints to powers centrifugal leak or require re- FILL MATERIAL blower with optional caulking and sealing. HDPE weather hood. High efficiency spiral wound PVC for maximum cooling. Model Approximate Weight Dimensions Capacity Fan Motor Sump Capacity Number Shipping Operating Dia. x Ht. Tons HP Gallons ∆t-10 350 705 38" x 78" 10 1 40 ∆t-15 360 725 38" x 78" 15 1.5 40 ∆t-20 385 750 38" x 78" 20 2 40 ∆t-25 405 765 38" x 78" 25 3 40 ∆t-30 710 1500 56" x 76" 30 5 75 ∆t-40 730 1525 56" x 76" 40 5 75 ∆t-50 910 2610 80" x 80" 50 5 157 ∆t-75 970 2675 80" x 80" 75 7.5 157 ∆t-100 1030 2730 80" x 80" 100 10 157 The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not, in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
  • 4. PARAGON® Induced Draft Cooling Tower 100 to 1000 ton cooling systems CORROSION- DIRECT DRIVE PROOF SHELL AIR MOVING HDPE Plastic • SYSTEM Totally enclosed cooling Construction can not corrode and is backed tower motor powers by 15 Year Warranty. fiber-reinforced polypropylene axial propeller fan. • • • LIGHTWEIGHT • • FILL MATERIAL AND High efficiency spiral HEAVY DUTY wound PVC cellular Plastic is lighter than design for maximum conventional cooling cooling. towers and average wall thickness is 5-10 times sheet metal towers. LEAK-PROOF DRIFT SUMP ELIMINATOR Molded as Unitary Polyethylene drift (One-Piece) eliminators prevent Structure that has no joints to leak or • water droplets from leaving the tower. require re-caulking and sealing. WATER DISTRIBUTION SYSTEM Self-propelled multiple PVC rotating arm system evenly distributes the water. Model Approximate Weight Dimensions Capacity Fan Motor Sump Capacity Number Shipping Operating Dia. x Ht. Tons HP Gallons ∆T-100I 1510 4235 84" x 146" 100 5 330 ∆T-125I 1585 4310 84" x 146" 125 7.5 330 ∆T-150I 1785 5570 95" x 178" 150 7.5 468 ∆T-175I 1925 5810 95" x 178" 175 10 468 ∆T-200I 3170 8440 114" x 210" 200 10 718 ∆T-250I 3365 8640 114" x 210" 250 15 718 The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not, in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
  • 5. TM SERIES™ Induced Draft Cooling Towers 250 to 20000 ton cooling systems DIRECT DRIVE FILL MATERIAL NOZZLE WATER DRIFT AIR MOVING DISTRIBUTION ELIMINATOR High efficiency PVC SYSTEM SYSTEM Three pass PVC drift cellular design for Totally enclosed cooling maximum cooling. Non-Clog large orifice eliminator prevents tower motors power removable nozzles evenly water droplets from multiple fiber-reinforced distribute the water. leaving the tower. polypropylene axial propeller fans within polyethylene velocity recovery stack. • • • • • • • • LIGHTWEIGHT LEAK-PROOF SELF CORROSION- INDEPENDENT AND SUMP SUPPORTING PROOF SHELL CELL DOUBLE-WALL Molded as Unitary PLASTIC BASE HDPE Plastic CAPABILITY Plastic is lighter than (One-Piece) Structure Tower can be set on flat Construction can not Independent Cells allow conventional cooling that has no joints to surface or on I-Beams corrode and is isolation of cells for towers and integrated leak or require re- placed in Integrally- backed by 15 Year operational flexibility. double-wall is more caulking and sealing. Molded I-Beam Pockets Warranty. than 10 times the for elevated installations. average wall thickness of metal towers. Model Approximate Weight Dimensions Capacity Fan Motor Sump Capacity Group Shipping Operating L x W x Ht. Tons HP Gallons 1 Cell 5020 10670 16.5' x 8.5' x 15.5' 250-425 10-30 480 2 Cell 10040 21340 16.5' x 17.0' x 15.5' 460-820 20-60 960 3 Cell 15060 32010 16.5' x 25.5' x 16.5' 700-1200 30-90 1400 4 Cell 20080 42680 16.5' x 34.0' x 16.5' 910-1580 40-120 1920 5 Cell 25100 53350 16.5' x 42.5' x 16.5' 1120-1710 50-120 2400 6 Cell 30120 64020 16.5' x 51.0' x 16.5' 1340-2020 60-120 2880 The information, recommendations and opinions set forth herein are offered solely for your consideration, inquiry and verification, and are not, in part or total, to be construed as constituting a warranty or representation for which we assume legal responsibility.
  • 6. Delta Cooling Towers has made substantial investments in manufacturing capabilities to provide the most trouble-free and longest lasting cooling towers available. • Maintenance Free Unitarily Molded Leak-Proof Shell • High Density Polyethylene Casing Carries 15-Year Warranty • Perfect for Applications from the Routine to Extremely Corrosive • Factory Assembled for Simple Installation • Made In The USA - Consistent High Quality • 30 Years of Leadership in Non-Corrosive Cooling Tower Manufacturing Delta Cooling Towers Leader in Non-Corrosive Cooling Tower Technology 134 Clinton Road, P.O. Box 952 Fairfield, New Jersey 07004-2970 Tel: 973-227-0300 • Fax: 973-227-0458 • 800-BUY-DELTA E-mail: deltacooling@att.net • Website www.deltacooling.com