Section

                                                                                                     3
Basic Unit Operation
Introduction
The following section provides basic instructions for starting the computer,
starting the engine, initializing the pumping unit, and shutting down the computer.


Step 1—Starting the Computer
The ACE pumping unit is equipped with an industrial computer that executes the
pumping unit’s automatic control software. Before the unit’s engine will start, the
software must be running. To start the software, perform the following steps:

    1. Turn on the pumping unit’s main electrical power switch (A, Figure 3.1).
    2. Turn on the industrial computer’s power switch (B, Figure 3.1). The
       computer will begin its boot-up process. After 1 to 2 minutes, the process
       will conclude and the NT operating system will display a Begin Logon
       window.
    3. With the Begin Logon window displayed, press the Ctrl, Alt, and Del
       keys simultaneously. The computer will display a Logon Information
       window.
    4. In the Logon Information window, type pump in the User Name entry
       field; then type pump in the Password entry field. Press OK and wait 1
       to 2 minutes for the startup process to end.




April 2001                                                                            Basic Unit Operation   3-1
A




                                                  12 14 16                                                                            OFF           ON
                                             10              18
                                         8



                                          VOLTS




                                              VOLTS                                                                                         POWER
              B
                                                                             ON                            ON                                                   RUN




                                                                             OFF                           OFF                                                  STOP

                                START                             COMPUTER                       FLOOD LIGHTS                 ETHER                      RUN/STOP




                                                   8                                  15                            15                       15




                                          TRANSMISSION                            FLOOD LIGHTS                  ETHER START                 ENGINE




                                        CHECK FUEL FILTER                                   ENGINE DIAGNOSTIC                          CHECK ENGINE




                                                         DISABLED                                          PRELUBE

                                                                                                           OFF

                                                         ACTIVE                                            WARM

                                          TRANSMISSION                                            ENGINE                               EMERGENCY
                                                                                                                                          KILL




                                                                    FRONT PANEL ASSEMBLY


             Figure 3.1—Main electrical power switch (A), and computer power switch (B)

                         When the startup process is complete, the pump control screen (Figure 3.2,
                         Page 3-3) will appear.




3-2   ACE Pump Operation and Service Manual                                                                                                                            April 2001
Resize
                                                               Minimize            Exit




Figure 3.2—Main pump control screen


Step 2—Starting the Engine
To start the engine, perform the following steps:

    1. With the pumping unit’s control software functioning, select the local unit
       to make it the active pumping unit for the control software. The local unit
       will have an asterisk beside its number. See the description of the
       Selected Pump list box in “Unit Information Area,” Section 5.
    2. Place the engine RUN/KILL switch in the RUN position.
    3. Confirm that the CHECK ENGINE light is off. Then start the pumping unit’s
       tractor and activate the PTO-driven hydraulic-start system.
    4. Press the unit’s engine START switch to start the engine, depressing the
       switch for no more than 30 seconds.
        If the unit does not start on the first attempt, release the START switch
        and allow the unit to rest approximately 30 seconds; then press the START
        switch again.




April 2001                                                                           Basic Unit Operation   3-3
Important        If the engine does not start after several attempts, observe the
                                          CHECK ENGINE light. If this light is on, the engine will not start.
                                          Press the engine throttle Up button to turn the light off. If the
                                          light remains on, contact a mechanic or electrical technician.

                             6. Deactivate the tractor’s hydraulic-start system.

                         Step 3—Initializing the Unit
                         When the pumping unit’s engine has been started and the pumping unit has been
                         selected as the control software’s active pumping unit, you are ready to initialize
                         the unit.

                         Important        Do not engage the transmission until you have completed the
                                          initialization process to verify the accuracy and operational
                                          setpoints of the sensors.

                         To initialize the unit, perform the following steps:

                             1. Check the operation of the pumping unit’s sensors by monitoring the
                                Gauge function control display (Page 6-2). If any of the sensors display
                                incorrect values, you may need to offset the sensors to the correct
                                operating values. If necessary, adjust the slope and span of the sensors.
                                For instructions on calibrating the sensors, see Page 6-6.

                         Important        Always offset the discharge pressure transducer to zero before
                                          bringing the pumping unit online against pressure. After the unit
                                          is online and pumping against pressure, offset the discharge
                                          pressure to match a “reference” pressure transmitter value if
                                          necessary.

                             2. Set the kickout pressure to a value determined by the stimulation supervi-
                                sor. The pressure kickout limit defaults to 500 psi at startup. For instruc-
                                tions on setting a unit’s kickout pressure, see Section 6.
                             3. Enter the desired pumping rate setpoint into the Ramp Setpoint system
                                parameter. For instructions on entering a new Ramp Setpoint system
                                parameter value, see Section 7.
                         To place the pumping unit in gear, press the Selected Truck, Group, or All Trucks
                         button. Then press the Engage button, and press the Ramp ON button to rapidly
                         bring the unit up to the desired flow-rate setpoint.


                         Shutting Down the Computer
                         At the end of a pumping operation, shut down the ACE pumping unit to prevent
                         potential startup problems during subsequent operations. This three-step process
                         consists of shutting down the pumping control software, shutting down the JLAN
                         software, and shutting down the NT operating system.



3-4   ACE Pump Operation and Service Manual                                                           April 2001
Shutting Down the Pumping Control Software
To properly shut down the pumping control software, perform the following steps:

    1. Verify that the pumping unit is in neutral.
    2. Press the Close button in the top right corner of the control screen (Figure
       3.2, Page 3-3). The pumping control software will close immediately.
    3. If the Close button does not appear on your screen, press the Minimize
       button to bring your full screen into view; then press the Close button to
       close the control software.

Shutting Down the JLAN Communications Software
When the pumping-control software closes, the JLAN communications software
for the pumping unit is displayed. This software must also be closed before the
industrial computer can be shut down.

To close the JLAN communications software, press the Close button (Figure 3.3).

                                                                             Resize
                                                                  Minimize            Exit




Figure 3.3—JLAN communications software window




April 2001                                                                            Basic Unit Operation   3-5
Shutting Down the NT Operating System
                         To shut down the NT operating system, perform the following steps:

                             1. Press the Start button (Figure 3.4). A Windows NT Workstation menu
                                will be displayed (Figure 3.5, Page 3-6).

                         Note            The location of the START button may vary between computers,
                                         depending on whether the task bar that contains the START button
                                         is positioned. However, the button has the same appearance on
                                         all computers.

                             2. With the Windows NT Workstation menu active, select Shut Down….
                                The Shut Down Windows dialog box (Figure 3.6, Page 3-6) will be
                                displayed.
                             3. Press the Yes button to continue the shutdown process. A Shutdown in
                                Progress window will be displayed briefly. When the NT operating
                                system has determined it is safe for the computer to be shut off, it will
                                replace the Shutdown in Progress window with Shut Down Computer.
                             4. When the Shut Down Computer window displays the message “It is now
                                safe to turn off your computer,” turn off the industrial computer’s power
                                switch (Figure 3.1, Page 3-1).
                             5. Turn off the pumping unit’s main electrical power switch (Figure 3.1).




                        Figure 3.4—Start button



3-6   ACE Pump Operation and Service Manual                                                       April 2001
Figure 3.5—NT system menu




Figure 3.6—Shut Down Windows window




April 2001                            Basic Unit Operation   3-7
3-8   ACE Pump Operation and Service Manual   April 2001

Weitere ähnliche Inhalte

Was ist angesagt?

Fordrazborka.zu8.ru lincoln
Fordrazborka.zu8.ru lincolnFordrazborka.zu8.ru lincoln
Fordrazborka.zu8.ru lincolnrukford
 
Vnx.su avensis-1997 owners-manual
Vnx.su avensis-1997 owners-manualVnx.su avensis-1997 owners-manual
Vnx.su avensis-1997 owners-manualgsx1
 
Variomat2 training
Variomat2 trainingVariomat2 training
Variomat2 trainingCalpeda
 
Calpeda control panel
Calpeda control panelCalpeda control panel
Calpeda control panelCalpeda
 
Caterpillar heui-controles-de-motor-3408 e-3412
Caterpillar heui-controles-de-motor-3408 e-3412Caterpillar heui-controles-de-motor-3408 e-3412
Caterpillar heui-controles-de-motor-3408 e-3412erick
 
Variable speed fire pump controllers
Variable speed fire pump controllersVariable speed fire pump controllers
Variable speed fire pump controllersmichaeljmack
 
Farallon Scooter DPV 2004 01-13 manual-mk-7_er
Farallon Scooter DPV 2004 01-13 manual-mk-7_erFarallon Scooter DPV 2004 01-13 manual-mk-7_er
Farallon Scooter DPV 2004 01-13 manual-mk-7_erAtlantic Scuba
 

Was ist angesagt? (9)

Fordrazborka.zu8.ru lincoln
Fordrazborka.zu8.ru lincolnFordrazborka.zu8.ru lincoln
Fordrazborka.zu8.ru lincoln
 
Vnx.su avensis-1997 owners-manual
Vnx.su avensis-1997 owners-manualVnx.su avensis-1997 owners-manual
Vnx.su avensis-1997 owners-manual
 
Diesel Fire Pump Controllers
Diesel Fire Pump ControllersDiesel Fire Pump Controllers
Diesel Fire Pump Controllers
 
Variomat2 training
Variomat2 trainingVariomat2 training
Variomat2 training
 
Calpeda control panel
Calpeda control panelCalpeda control panel
Calpeda control panel
 
Caterpillar heui-controles-de-motor-3408 e-3412
Caterpillar heui-controles-de-motor-3408 e-3412Caterpillar heui-controles-de-motor-3408 e-3412
Caterpillar heui-controles-de-motor-3408 e-3412
 
Variable speed fire pump controllers
Variable speed fire pump controllersVariable speed fire pump controllers
Variable speed fire pump controllers
 
Farallon Scooter DPV 2004 01-13 manual-mk-7_er
Farallon Scooter DPV 2004 01-13 manual-mk-7_erFarallon Scooter DPV 2004 01-13 manual-mk-7_er
Farallon Scooter DPV 2004 01-13 manual-mk-7_er
 
Antilock brakes
Antilock brakesAntilock brakes
Antilock brakes
 

Ähnlich wie Ace pump section_3

action-d20dt-repairs-manual.pdf
action-d20dt-repairs-manual.pdfaction-d20dt-repairs-manual.pdf
action-d20dt-repairs-manual.pdfalexgeneral
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manualofpsdjksemmds
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manualufjjdjkksdekmd
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manualujfjjkskkmmem
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manualdfjkskeeplol
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfukdkksmmd
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualufjjsjekkemd
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualfjsjjekdkme
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfifkksem9didok
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdff8soekmdmdm
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualfujsjefkksekmm
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualhhfjksekmm
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfzao908wangsa
 

Ähnlich wie Ace pump section_3 (20)

action-d20dt-repairs-manual.pdf
action-d20dt-repairs-manual.pdfaction-d20dt-repairs-manual.pdf
action-d20dt-repairs-manual.pdf
 
Fadal Power On-Off Operator Manual.pdf
Fadal Power On-Off Operator Manual.pdfFadal Power On-Off Operator Manual.pdf
Fadal Power On-Off Operator Manual.pdf
 
Fadal power on off - operator manual
Fadal power on off - operator manualFadal power on off - operator manual
Fadal power on off - operator manual
 
Fadal Operator's Manual
Fadal Operator's ManualFadal Operator's Manual
Fadal Operator's Manual
 
Project on PLC (SILO)
Project on PLC (SILO)Project on PLC (SILO)
Project on PLC (SILO)
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manual
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manual
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manual
 
Jcb ams js machines service repair manual
Jcb ams js machines service repair manualJcb ams js machines service repair manual
Jcb ams js machines service repair manual
 
Presentation PLC
Presentation PLCPresentation PLC
Presentation PLC
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manual
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manual
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manual
 
Jcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manualJcb 1 tht dumper service repair manual
Jcb 1 tht dumper service repair manual
 
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdfJCB 1THT Dumper Service Repair Manual Instant Download.pdf
JCB 1THT Dumper Service Repair Manual Instant Download.pdf
 
Bernini ATM910.pdf
Bernini ATM910.pdfBernini ATM910.pdf
Bernini ATM910.pdf
 
Cat
CatCat
Cat
 

Ace pump section_3

  • 1. Section 3 Basic Unit Operation Introduction The following section provides basic instructions for starting the computer, starting the engine, initializing the pumping unit, and shutting down the computer. Step 1—Starting the Computer The ACE pumping unit is equipped with an industrial computer that executes the pumping unit’s automatic control software. Before the unit’s engine will start, the software must be running. To start the software, perform the following steps: 1. Turn on the pumping unit’s main electrical power switch (A, Figure 3.1). 2. Turn on the industrial computer’s power switch (B, Figure 3.1). The computer will begin its boot-up process. After 1 to 2 minutes, the process will conclude and the NT operating system will display a Begin Logon window. 3. With the Begin Logon window displayed, press the Ctrl, Alt, and Del keys simultaneously. The computer will display a Logon Information window. 4. In the Logon Information window, type pump in the User Name entry field; then type pump in the Password entry field. Press OK and wait 1 to 2 minutes for the startup process to end. April 2001 Basic Unit Operation 3-1
  • 2. A 12 14 16 OFF ON 10 18 8 VOLTS VOLTS POWER B ON ON RUN OFF OFF STOP START COMPUTER FLOOD LIGHTS ETHER RUN/STOP 8 15 15 15 TRANSMISSION FLOOD LIGHTS ETHER START ENGINE CHECK FUEL FILTER ENGINE DIAGNOSTIC CHECK ENGINE DISABLED PRELUBE OFF ACTIVE WARM TRANSMISSION ENGINE EMERGENCY KILL FRONT PANEL ASSEMBLY Figure 3.1—Main electrical power switch (A), and computer power switch (B) When the startup process is complete, the pump control screen (Figure 3.2, Page 3-3) will appear. 3-2 ACE Pump Operation and Service Manual April 2001
  • 3. Resize Minimize Exit Figure 3.2—Main pump control screen Step 2—Starting the Engine To start the engine, perform the following steps: 1. With the pumping unit’s control software functioning, select the local unit to make it the active pumping unit for the control software. The local unit will have an asterisk beside its number. See the description of the Selected Pump list box in “Unit Information Area,” Section 5. 2. Place the engine RUN/KILL switch in the RUN position. 3. Confirm that the CHECK ENGINE light is off. Then start the pumping unit’s tractor and activate the PTO-driven hydraulic-start system. 4. Press the unit’s engine START switch to start the engine, depressing the switch for no more than 30 seconds. If the unit does not start on the first attempt, release the START switch and allow the unit to rest approximately 30 seconds; then press the START switch again. April 2001 Basic Unit Operation 3-3
  • 4. Important If the engine does not start after several attempts, observe the CHECK ENGINE light. If this light is on, the engine will not start. Press the engine throttle Up button to turn the light off. If the light remains on, contact a mechanic or electrical technician. 6. Deactivate the tractor’s hydraulic-start system. Step 3—Initializing the Unit When the pumping unit’s engine has been started and the pumping unit has been selected as the control software’s active pumping unit, you are ready to initialize the unit. Important Do not engage the transmission until you have completed the initialization process to verify the accuracy and operational setpoints of the sensors. To initialize the unit, perform the following steps: 1. Check the operation of the pumping unit’s sensors by monitoring the Gauge function control display (Page 6-2). If any of the sensors display incorrect values, you may need to offset the sensors to the correct operating values. If necessary, adjust the slope and span of the sensors. For instructions on calibrating the sensors, see Page 6-6. Important Always offset the discharge pressure transducer to zero before bringing the pumping unit online against pressure. After the unit is online and pumping against pressure, offset the discharge pressure to match a “reference” pressure transmitter value if necessary. 2. Set the kickout pressure to a value determined by the stimulation supervi- sor. The pressure kickout limit defaults to 500 psi at startup. For instruc- tions on setting a unit’s kickout pressure, see Section 6. 3. Enter the desired pumping rate setpoint into the Ramp Setpoint system parameter. For instructions on entering a new Ramp Setpoint system parameter value, see Section 7. To place the pumping unit in gear, press the Selected Truck, Group, or All Trucks button. Then press the Engage button, and press the Ramp ON button to rapidly bring the unit up to the desired flow-rate setpoint. Shutting Down the Computer At the end of a pumping operation, shut down the ACE pumping unit to prevent potential startup problems during subsequent operations. This three-step process consists of shutting down the pumping control software, shutting down the JLAN software, and shutting down the NT operating system. 3-4 ACE Pump Operation and Service Manual April 2001
  • 5. Shutting Down the Pumping Control Software To properly shut down the pumping control software, perform the following steps: 1. Verify that the pumping unit is in neutral. 2. Press the Close button in the top right corner of the control screen (Figure 3.2, Page 3-3). The pumping control software will close immediately. 3. If the Close button does not appear on your screen, press the Minimize button to bring your full screen into view; then press the Close button to close the control software. Shutting Down the JLAN Communications Software When the pumping-control software closes, the JLAN communications software for the pumping unit is displayed. This software must also be closed before the industrial computer can be shut down. To close the JLAN communications software, press the Close button (Figure 3.3). Resize Minimize Exit Figure 3.3—JLAN communications software window April 2001 Basic Unit Operation 3-5
  • 6. Shutting Down the NT Operating System To shut down the NT operating system, perform the following steps: 1. Press the Start button (Figure 3.4). A Windows NT Workstation menu will be displayed (Figure 3.5, Page 3-6). Note The location of the START button may vary between computers, depending on whether the task bar that contains the START button is positioned. However, the button has the same appearance on all computers. 2. With the Windows NT Workstation menu active, select Shut Down…. The Shut Down Windows dialog box (Figure 3.6, Page 3-6) will be displayed. 3. Press the Yes button to continue the shutdown process. A Shutdown in Progress window will be displayed briefly. When the NT operating system has determined it is safe for the computer to be shut off, it will replace the Shutdown in Progress window with Shut Down Computer. 4. When the Shut Down Computer window displays the message “It is now safe to turn off your computer,” turn off the industrial computer’s power switch (Figure 3.1, Page 3-1). 5. Turn off the pumping unit’s main electrical power switch (Figure 3.1). Figure 3.4—Start button 3-6 ACE Pump Operation and Service Manual April 2001
  • 7. Figure 3.5—NT system menu Figure 3.6—Shut Down Windows window April 2001 Basic Unit Operation 3-7
  • 8. 3-8 ACE Pump Operation and Service Manual April 2001