The high power HVA200 VLF/DC tester is capable of testing cables up to 138 kV with a test voltage of 1,7 x Uo and allows diagnostics with Partial Discharge and Tan Delta. It is the smallest and lightest high voltage hipot tester offering Very Low Frequency testing at 0.1 Hz as well as DC output up to 200 kV.
13. 13
HVA200
Type HVA200
Input Voltage 3 x 230 V AC
Input Frequency 48 – 62 Hz
Power Input 8 kVA
Output Power 6 kVA
Output Voltage AC
0,01 Hz – 0,1 Hz
Sinus
0 – 138 kVrms (200kVpeak)
Output Voltage DC +/- 200 kV
Output Current DC 100 mA
Max. C Load 0,6 µF@0,1Hz / 6µF at 0,01Hz
Interface Optical fiber
Weight < 850 kg
Protection Class IP 22
18. 18
HVA200
Unlimited operating time
Dry System - no oil filled parts
- Easier transport
- Less maintenance
Simple transport
- Boxes
- Integration in a test van