1. ^ * t
NABL
National Accreditation Board for
Testing and Calibration Laboratories
Department of Science & Technology, India
CERTIFICATE OFACCREDITATION
QRICS CALIBRATION LABORATORIES PVT. LTD.
hasbeenassessedandaccreditedinaccordancewiththestandard
ISO/IEC17025:2005
"GeneralRquirementsfortheCompetenceofTesting&CalibrationLaboratories"
for itsfacilitiesat
'PARAS' Complex, GP/67, Office No.7,8&9 Basement,Thermax Ctiowk, MIDC,Chinchwad, Pune
inthe disciplineof
MECHANICAL CALIBRATION
(To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org)
Certificate Number C-0131
Issue Date 28/06/2012 Valid Until 27/06/2014
This certificateremains valid for the Scope of Accreditation as specified in the annexure subject to
continued satisfactory compliance to the above standard &the additional requirements of NABL.
Signed for and on behalf of NABL
Shallv Sharma Anil Relia Dr T Ramasami
3. "«*«,.
Laboratory
NflBL
Deportment of Science a Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/I EC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012 §
r
Valid Until 27.06.2014 '
Page 1of10
Quantity Measured/
Instrument
Range I Frequency "Calibration Measurement
Capability (±)
Remarks
1. EXTERNAL
MICROMETER '
L.C. 0.001mm
L.C. 0.01mm
2. CALIPER'
(Digital/ Dial/ Electronic)
L.C. 0.01mm
| (Vernier & Dial)
I L.C.0.02 mm
I
3. VERNIER DEPTH'
(Digital Type)
L.C. 0.01mm
(Vernier Type)
L.C. 0.02mm
Upto 100 mm
Upto 100mm
Upto 300 mm
Upto 600 mm
Upto 900 mm
Upto 1000mm
Upto 300 mm
Upto 600 mm
Upto 1000 mm
Upto 300 mm
Upto 600 mm
Upto 1000mm
Upto 300 mm
Upto 600 mm
Upto 300 mm
Upto 600 mm
2.0 urn
6.5 u,m
10.19 ^m
11.0 (am
12.0 (im
13.0 (am
10.4 jam
10.5 pm
17.6 urn
16.7 (im
16.8 urn
19.5 urn
12.9 urn
14.8 urn
18.4 urn
19.8 urn
Using Slip Gauge Blocks
Using Slip Gauge Blocks &
Plunger Dial
Using Caliper Checker &
Length Bar
Using Caliper Checker &
Length Bar
Using Caliper Checker &
Slip Gauges
4. Laboratory
MflBL
Department offScience a Technology. India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 2 of 10
Quantity Measured/
Instrument
Range/ Frequency "Calibration Measurement
Capability (±)
Remarks
HEIGHT GAUGE '
(Digital/Dial/Electronic)
L.C. 0.01mm
L.C. 0.02mm
ELECTRONIC
HEIGHT GAUGE3
L.C. 0.001mm
Linear
Squareness
DEPTH
MICROMETER'
L.C. 0.001mm
L.C. 0.01mm
HEIGHT
MICROMETER'
L.C. 0.002 mm
Upto 300 mm
Upto 600 mm
Upto 1000 mm
Upto 300 mm
Upto 600 mm
Upto 1000 mm
Upto 600 mm
Upto 600 mm
Upto 600 mm
Upto 100 mm
Upto 100mm
300mm
11.3 urn
11.3 urn
14.8 urn
17.5 urn
17.6 (am
19.4 urn
5.6 um
6.6 (am
11.0 urn
11.5 jam
12.0 urn
7.0
Using Caliper Checker &
Length Bar
Using Slip Gauges
& Cylinder Square
Using Analog Comparator &
Electronic Height Gauge
Using Slip Gauges
Using Lever Dial, Slip
Gauges &Surfaceplate
5. NflBL
Laboratory
Department of Science fi Technology, Indiq
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 3 of 10
I
1
I
I
8.
9.
10.
Quantity Measured/
Instrument
INTERNAL
MICROMETER '
L.C. 0.01mm
PLUNGER DIAL '
L.C. 0.001 mm
L.C. 0.01 mm
LEVER DIAL '
L.C. 0.001 mm
L.C. 0.002 mm
Range / Frequency
Upto 25 mm
Upto 10 mm
Upto 50 mm
Upto 50 mm
0.14 mm
0.2mm
"Calibration Measurement Remarks j
Capability (±) 1
6.5 um
2.6 (im
3.2 (im
7.0 urn
2.6 ^m
3.1 um
i1
Using Plunger Dial & Slip 1
Gauges i
!
Using Electronic Probe 1
Using Dial Calibration Tester I
i
Using ElectronicProbe ',
$
L.C. 0.01 mm
11. DIAL THICKNESS
GAUGEl
L.C. 0.01 mm
12. PLAIN PLUG GAUGES/
CYLINDRICAL OD/
PIN1
13. SNAP GAUGE/
LENGTH GAUGE1
I mm
Upto 20 mm
Upto0 150mm
Upto 0 300 mm
Upto 300 mm
300 to 500 mm
7.0 urn
6.0 um
2.7 urn
3.4 um
3.2 urn
9.2 (am
Using Dial Calibration Tester
Using Slip Gauges
Using Plunger Dial & Slip '.
Gauges
Using Slip Gauges •'
3
Using ElectronicHeight f
Gauge !
6. NflBL
Laboratory
Department offScience a Technology, Indio
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 4 of 10
14.
15.
16.
17.
18.
19.
Quantity Measured/
Instrument
FEELER GAUGE '
BEVEL
PROTRACTOR '
ANGLE
PROTRACTOR/
COMBINATION SETl
STEEL TAPE l
L.C. 1mm
STEEL RULE '
V BLOCK l
Parallelism
Squareness
Range / Frequency
Upto 1mm
0 to 360°
Oto180°
Upto 50 m
Upto 1000mm
Upto 300 mm
Upto 300 mm
'Calibration Measurement Remarks f
Capability (±) f
4.0 (im
3 minof arc
35 min
0.16x j L mm
Vi
L inmtr
80.0 urn
5.0 urn
11.0 urn
1
Using Digimatic Micrometer I
Using Angle Block, Sine Bar, 1
Slip Gauges & Surface Plate 1
Using Angle Block, Sine Bar, 1
Slip Gauges & Surface Plat I
Using Length Measuring 1
Machine J
ji
Using Length Measuring |
Machine j
Using Surface Plate, Plunger
Dial & Analog Comparator
20. MASTER FOILS FOR
COAT THICKNESS'
21. THREAD PLUG
GAUGE'
(Maj0 &Effective 0)
22. THREAD RING '
(Effective 0)
Upto 1 mm
Upto M l 00
M3 toM100
4.0
4.3 um
2.5 urn
Using Digimatic Micrometer
Using Floating Carriage,
Measuring Pin & OD Master
Using LMM & Master Ring
7. Laboratory
MflBL
Deportment offScience S Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
I
Valid Until 27.06.2014 |
Page 5 of 10
Quantity Measured/
Instrument
Range/ Frequency "Calibration Measurement
Capability (±)
Remarks
23. BORE GAUGE'
(Transmission
Mechanism check only)
L.C. 0.001 mm
L.C. 0.01 mm
24. ENGINEERS
SQUARE/SQUARE
BLOCK/ANGLE
PLATE'
Squareness
Parallelism
25. SETTING ROD/RISER
BLOCKl
26. SPIRIT LEVEL1
27. DIAL CALIBRATION
TESTER'
L.C. 0.001 mm
28. ELECTRONIC
COMPARATOR
PROBE'
L.C. 0.0001 mm
L.C. 0.01 mm
Upto 1 mm stroke
Upto 1mm stroke
Upto 200 mm
Upto 25 mm
Upto 3 um
Upto 30 um
4.6 urn
7.0 urn
iO mm x 600 mm
10 mm x 600 mm
Upto 150mm
Upto 300 mm
Upto 600 mm
ll.Oum
5.4 (am
2.6 urn
3.0 um
4.0 um
9 um/m
2.6 um
1.4 um
1.2 m
Using Electonic Dial
Calibration Tester
Using Plunger Dial, Analog |
Comparator & Surface Plate |
Using Plunger Dial, Slip I
Gauges & Electronic Height|
Gauge *
Using Sinebar, Surface Plate
& Slip Gauge
Using Electronic Probe with
DRO & Slip Gauges
Using Slip Gauges
8. ^WSSWHP!^^
MflBL
Laboratory
Department offScience S Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 6 of 10
j<
29.
30.
31.
32.
33.
34.
35.
36.
Quantity Measured/
Instrument
PISTOL CALIPER '
L.C. 0.1mm
STANDARD STEEL
WIRE GAUGE '
FLOW CUP1
(Jet Dia)
CENTER DISTANCE '
SETTINGRING
GAUGE '
PLAIN RING GAUGE'
SINE BAR 1
Angle
Parallelism
Roller Distance
COMPARATOR
STAND l
Flatness
Squareness
Range / Frequency "Calibration Measurement Remarks
Capability (±)
0 to 50 mm
0 to 10 mm
0 4.0 mm
Upto 300 mm
Upto 100mm
Upto 100mm
100 mm to 300 mm
Upto 200 mm
Upto 200 mm
Upto 200 mm
Upto 300 mm
Upto 300 mm
60 um
13.0 um
4.0 urn
9.0 um
2.8 urn
5.40 um
5.50 um
11.0 Sec
3.5 um
5.4 um
4.6 um
6.7 um
Using Slip Gauge
Using Feeler Gauge & Slip j
Gauge ]
Using Hole Test & Digimatic
Mic. |
Using ElectronicHeight j
Gauge 1
Using LMM
Using Electronic Height
Gauge
Using Slip Gauge & Surface
Plate ;
Using Dial Comparator i
37. TAPER THREAD
PLUG1
Upto 100mm 5.0 Using FloatingCarriage •
I
9. ^*;»ii«a9S3a^^
NflBL
Laboratory
Department of Science S Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 7 of 10
38.
39.
40.
41.
Quantity Measured/
Instrument
TWO PINDIAL '
L.C. 0.01 mm
L.C. 0.025mm
DIAL SNAP GAUGE '
STRAIGHT EDGE '
Straightness
Parallelism
OD MASTER '
Diameter
Concentricity
Range / Frequency "Calibration Measurement Remarks
Capability (±)
0 to 75 mm
0 to 75 mm
Upto 100 mm
Upto 1000 mm
Upto 1000mm
Upto 100mm
Upto 100mm
8.0 urn
16.0 urn
2.5 urn
9.0 urn
5.5 urn
3.0 urn
3.5 urn
Using Micrometer & Dial
Calibration Tester
Using Slip Gauges
Using Surface Plate &
Plunger Dial
Using Analog Comparator i
Slip Gauges
42. PLAIN TAPER PLUG
GAUGE'
43. RADIUS GAUGE l
44. THREAD PITCH
GAUGE'
Angle
Linear
45. PLAIN TAPER RING
GAUGE'
Angle Measurement upto
100mm
Upto 25 mm
60°
60°
Angle Measurement
12minof Arc
7.9 urn
12minof Arc
8.5 urn
60"
Using Profile Projector/
Electronic Height Gauge &
Slip Gauges
Using Profile Projector
Using Profile Projector
Using ElectronicHeight
Gauge/ Gauge Blocks
10. ^^^
Laboratory
NflBL
Department offScience a Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 8 of 10
Quantity Measured/
Instrument
Range/ Frequency "Calibration Measurement
Capability (±)
Remarks
46. V GROOVE
MICROMETER'
L.C. 0.01 mm
L.C. 0.001 mm
47. GRATICULE'
L.C. 0.05 mm
Linear
48. SURFACE PLATE 2
49. FLOATING
CARRIAGE l
L.C. 0.0001 mm
50. THREAD MEASURING
WIRES'
51. THREAD MEASURING
PRISMS '
52. SLIP GAUGE SET'
Upto 100mm
Upto 100mm
0 to 25mm
2500 mm x 2500 mm
Oto 100mm
0.17 mm to 6.35mm
A/B/C/D
Upto 20 mm
20 mm to 50 mm
50 mm to 100 mm
1.2x
7.0 urn
2.17 urn
30.0
+
100
2.7 urn
1.4 urn
1.4 um
um
0.14 urn
0.23 urn
0.32 xm
Using OD Master
Using Profile Projector
Using Spirit Level
Using Slip Gauges, OD
Master &Mandril
Using Electronic Probe
As per IS 6311 |
$
I
Using Electronic Probe 1
As per IS 6150 J
Using Slip Gauge Calibrator }
11. Laboratory
NflBL
Department offScience fi Technology, India
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 9 of 10
Quantity Measured/
Instrument
Range/ Frequency "Calibration Measurement
Capability (±)
Remarks
S3. PROFILE PROJECTOR'
X-Y Axis
L.C. 0.001 mm
L.C. 0.005 mm
Angular Scale
Magnification
54. TRAVERSE OF
CUPPING MACHINE 2
L.C. 0.05 mm
55. PRESSURE GAUGE
CALIBRATION '
Upto 300 mm Screen &
Traverse 100 mm
56. PRESSURE / VACUUM
GAUGE
CALIBRATION 3
57. PRESSURE GAUGE
CALIBRATION 2
0 to 20 mm
1 kg/cm2to 65 kg/cm2
70 kg/cm2to 700 kg/cm2
0 to 20 kg/cm2
0 to 700 kg/cm2
-0.68 kg/cm2to 0 kg/cm2
0 to 20 kg/cm2
0 to 700 kg/cm2
2.5 urn
6.5 jam
4 minof arc
0.07%
0 to 0.06 mm
4.7%ofrdg
0.53% of rdg
3.35% of rdg
11.61% of rdg
6.67% of rdg
8.23% of rdg
11.61% of rdg
Using Slip Gauges, Steel
Ball, Digital Caliper & Angle
Blocks
Using Digital Depth Vernier
Using Dead Weight Tester
Using Digital Pressure GaugeS
and Pumping Set |
by Comparison Method
Using Digital Pressure Gauge|
and Pumping Set
Comparison Method
Using Digital Pressure Gauge 1
and Pumping Set J
Comparison Method |
12. Laboratory
NflBL
Department offScience a Technology, Indiq
SCOPE OF ACCREDITATION
QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office
No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune
Accreditation Standard ISO/IEC 17025:2005
Discipline Mechanical Calibration
Certificate Number C-0131
Last Amended on 06.05.2013
Issue Date 28.06.2012
Valid Until 27.06.2014
Page 10 of 10
Quantity Measured/
Instrument
Range/ Frequency "Calibration Measurement
Capability (±)
Remarks
58. HANDTORQUE
TOOLS l
All Classes Type I & II
0 to 5Nm
0 to 20Nm
Oto 100 Nm
0 to 500 Nm
Oto lOOONm
0.98% of rdg
0.98% of rdg
0.58% of rdg
0.62% of rdg
0.85% of rdg
Using DigitalTorqueWrench
Calibration System
as per IS/ISO6789
* Measurement Capability is expressedas an uncertainty (±) at a confidence probability of 95%
1 Only in Permanent Laboratory
2 Only for Site Calibration
3 The laboratory is also capable for site calibration however; the uncertainty at site depends on the prevailingactual
environmental conditionsand masterequipment used.