1. Eligibility Criteria for Passive OEM:
. OEM should be in Interconnection business with converge solution offering with
various Connectivity platforms like Structure cabling, Telecom Network, GPON
network etc.
. OEM should have been market leader at least once in Indian Structured Cabling
Market. (Supporting Media Reports required).
. OEM should have at least 30% market share in SCS Market.
. OEM should have presence Indian market with manufacturing and product
Development center in India.
. OEM should have technology development program partnership with any one of
the top 3 Active networking (Switches and Routers) OEM’s globally.(Reference
required)
. OEM should have at least One RCDD certified person sitting in India
. All material should be from one OEM make only.
. OEM should have an experience in supply and execution of at least 3 similar
type of Network in India. (Customer Certificate required alteast for one project).
. OEM should have done 1 Institution Campus Network on same type of
technology and products. ( Reference Required)
. OEM should have at least 4 training centers in India
3. FOR TECHNICAL BID AND COMPLIANCE STATEMENT FOR UTP CABLING SYSTEM
UTP CABLING SYSTEM
Sr Compliance
No. Details Specification Deviation
1 Type Unshielded twisted pair cabling system, Certificate by Yes / No
Intertek (ETL) for the 4-Connectors channel testing to
the Cat 6 Cabling system as per the ANSI/TIA 568 C.2
& as well as the ISO 11801 standards up to 600 MHz.
2 Networks 10 / 100/1000 Ethernet, 155 Mbps ATM, 1000 Mbps Yes / No
Supported IEEE 802.3ab Ethernet, and proposed Cat 6 Gigabit
Ethernet
3 TIA / EIA 568 C.2 ETL Verified / UL Listed Yes / No
4 Warranty 25 year systems warranty; Warranty to cover Yes / No
Bandwidth of the specified and installed cabling
system, and the installation costs
5 Performance Yes / No
characteristics to (a) Attenuation, Pair-to-pair and PS NEXT, ELFEXT
be provided along and PSELFEXT, Return Loss, ACR and PS ACR for 4-
with bid connector channel
(b) Should perform to CAT6 with short channel Yes / No
(c) 4-Connectors channel testing to the Cat 6 Cabling Yes / No
system as per the ANSI/TIA 568 C.2 & as well as the
ISO 11801 standards up to 600 MHz.
(d)Should have a PSNEXT margin of 7.5 dB over Yes / No
CAT6
(e) CAT6 cabling system should be tested and verified
by the Independent third party laboratories for Zero
BER (Bit Error Rate) testing at the data transmission
speed of 1 Gbit/s.
4. UTP CABLE
Sr Compliance
No. Details Specification Deviation
Type Unshielded Twisted Pair, Category 6, TIA / EIA 568- Yes / No
1 C.2 & ISO/IEC 11801
2 Conductors 23 AWG solid bare copper Yes / No
3 Insulation Polyethylene Yes / No
4 Jacket Flame Retardant PVC Yes / No
Pair Separator Cross-member (+) fluted Spline.
5 Approvals (a) UL Listed / UL Verified Yes / No
(b) ETL verified to TIA / EIA Cat 6 Yes / No
Operating Yes / No
6 temperature -20 Deg. C to +60 Deg. C
Storage
Temperature -20 Deg. C to +80 Deg. C
Frequency tested Yes / No
7 up to Minimum 600 MHz
8 Packing Box of 305 meters Yes / No
Cable Outer Yes / No
9 Diameter .23 inches
Delay Skew 45ns MAX. Yes / No
10
11 Bend Radius 4 * Cable Diameter Yes / No
12 Impedance 100 Ohms + / - 15 ohms, 1 to 600 MHz. Yes / No
UL/NEC Ratings CMR Rated Yes / No
13
Mutual 5.6 NF MAX /100 Mtr. Yes / No
14 Capacitance
Conductor 66.58 Ohms Max / KM Yes / No
15 Resistance
Propagation Delay 536 ns/100 Mtrs. MAX @ 250 Mhz Yes / No
16
Performance Yes / No
characteristics to
be provided along Attenuation, Pair-to-pair and PS NEXT, ELFEXT and
17 with bid PSELFEXT, Return Loss, ACR and PS ACR
Yes / No
18 ROHS Compliant ROHS/ELV Compliant
5. UTP JACKS
Sr Compliance
No. Details Specification Deviation
1 Type PCB based, Unshielded Twisted Pair, Category 6, Yes / No
TIA /EIA 568-C.2 and ISO/IEC 11801
2 Modular Jack 750 mating cycles Yes / No
3 Wire terminal 200 termination cycles Yes / No
4 Integrated bend-limiting strain-relief unit for cable entry
Accessories
Integrated hinged dust cover Yes / No
Support cable pair termination process on the jacks at Yes / No
90 degree angle.
Bidder should have a mechanism to maintain the Yes / No
quality of the termination ir-respective of the skill level
of the termination staff.
5 Housing Polyphenylene oxide, 94V-0 rated. Yes / No
6 110 Blocks polycarbonate, 94V-0 rated Yes / No
7 Jack contacts Beryllium copper, plated with 1.27 mm [.000050] thick Yes / No
gold in localized area and 3.81 mm [.000150] minimum
thick tin-lead in solder area over 1.27 mm [.000050]
minimum thick nickel under plate
8 Wiring blocks Polycarbonate, 94V-0 rated Yes / No
9 Approvals (a) UL Listed / CSA Approved Yes / No
(b) ETL verified to TIA / EIA Cat 6 Yes / No
10 Performance Attenuation, NEXT, PS NEXT, FEXT and Return Loss Yes / No
Characteristics to
be provided with
bid
11 Yes / No
ROHS Compliant ROHS/ELV Compliant
6. UTP JACK PANELS 24 PORT
Sr Compliance
No. Details Specification Deviation
Type 24-port, Modular, PCB based, Unshielded Twisted Yes / No
Pair, Category 6, TIA / EIA 568-C.2 and ISO/IEC
1 11801
2 Ports 24 Yes / No
Port arrangement Configured as 6 Port Module with individually
3 replaceable CAT-6 Jacks
Circuit Front of each module shall be capable of accepting 9 Yes / No
4 Identification mm to 12 mm labels
Port Identification 9mm or 12mm Labels on each of 24-ports (to be Yes / No
5 included in supply
6 Modular Jack 750 mating cycles
7 Wire terminal 200 termination cycles Yes / No
8 Accessories Integrated bend-limiting strain-relief unit for cable entry Yes / No
Yes / No
9 Materials
Housing Polyphenylene oxide, 94V-0 rated Yes / No
Wiring blocks Polycarbonate, 94V-0 rated Yes / No
Jack contacts Beryllium copper, plated with 1.27 mm [.000050] thick Yes / No
gold in localized area and 3.81 mm [.000150] minimum
thick tin-lead in solder area over 1.27 mm [.000050]
minimum thick nickel under plate
Panel Black, powder coated steel Yes / No
10 Approvals UL listed / ETL Verified Yes / No
Termination Yes / No
11 Pattern TIA / EIA 568 A and B;
Yes / No
12 ROHS Compliant ROHS/ELV Compliant
UTP JACK PANELS 48 PORT
7. Type 1U Patch panel
Ports 48
Should be available in both Angled & straight
Port arrangement 4 Modules of 12-ports each, with individually replaceable RJ-45 Jacks
with Strain relief and bend-limiting boot for cable
Category Category 6 exceeding TIA / EIA 568-C.2 & ISO/IEC 11801 exceeding
component performance
Wiring Compatible either T568A or T568B
Port Identification Capable of accepting an icon to indicate its function
Termination All four pairs of a four pair cable to be terminated at one time
technique
Height 1 U (1.75 inches)
Electrical
Characteristics
Modular Jack 750 mating cycles
Wire terminal 200 termination cycles
Pull Force 89N
Voltage 150VAC max
Operating Temp -40 to 70 deg C
Materials
Modular Jack Polyphenylene oxide, 94V-0 rated
Housing
IDC Connecting Polycarbonate, 94V-0 rated
Block
Panel Black powder coated steel
Contacts Beryllium copper, plated with 1.27um thick gold in localized area & 3.8 um
minimum thick matte tin in solder area over 1.27 um minimum thick nickel
underplate
Insulation Phosphorous bronze, plated with 3.81 um minimum thick matte tin over
Displacement 1.27 um minimum thick nickel underplate
contact
Warranty 25 Years
ROHS ROHS Compliance
Approvals UL Listed
Performance Insertion Loss, Return Loss, NEXT & FEXT
Characteristics to
be provided with
bid
Insertion Loss At 100 MHz – Max 0.06 dB & at 250 MHz – Max 0.10dB
Return Loss At 100 MHz – Min 33.2 dB & at 250 MHz – Min 17.4 dB
NEXT At 100 MHz – Min 57.7 dB & at 250 MHz – Min 47.9 dB
FEXT At 100 MHz – Min 48.7 dB & at 250 MHz – Min 40.1 dB
8. WORKSTATION / EQUIPMENT PATCH CORDS
Sr Compliance
No. Details Specification Deviation
1 Type Unshielded Twisted Pair, Category 6, TIA / EIA 568- Yes / No
C.2 & ISO/IEC 11801
2 Conductor 24 AWG 7 / 32, stranded copper conductors 100 Ohm Yes / No
3 Length 4 feet, 7 feet, 10 feet Yes / No
4 Plug Protection Yes / No
Transparent Slim boot
5 Warranty 25-year component Yes / No
6 Insulation Flame Retardant Polyethylene Yes / No
7 Yes / No
ROHS Compliant ROHS/ELV Compliant
FACE PLATE
Sr Compliance
No. Details Specification Deviation
1 Type Single Gang Yes / No
2 Material ABS / UL 94 V-0 Yes / No
3 No. of ports One/Two Yes / No
Yes / No
4 ROHS Compliant ROHS/ELV Compliant
10. Sr
No. Specifications Requirement Compliance Deviation
1 6 - core Single Mode, Armoured, Loose-tube, Gel Yes / No
Cable Type filled
2 Fibre Type Single Mode, 9/125 micron primary coated buffers Yes / No
3 No. of cores 6 Yes / No
4 Armour Corrugated Steel Tape Armour Yes / No
5 Cable Construction Yes / No
Type BELLCORE GR 20 / IEC 794-1
6 Attenuation @ 1310nm<= 0.40 db/KM Typical <=0.50 MAX Yes / No
@1550nm <= 0.30 dB/KM Typical <=0.40 MAX Yes / No
7 Cut Off Wave length <1260 Yes / No
8 @ 1310nm 9.3 + - 0.5 Yes / No
Mode Field Diameter @1550nm 10.5 + - 1.0
9 Yes / No
Clad Diameter (um) 125 + - 1
10 Yes / No
Concentricity (um) <=0.6
11 Yes / No
NON-Circularity (%) <=1
12 Yes / No
Coat Diameter 245 + - 10
13 Zero Dispersion Yes / No
Wavelength (um) 1310 + - 10
14 Yes / No
Tensile Strength 1500 Newtons
15 Yes / No
Crush Resistance 440 N/cm
16 Bend Radius Yes / No
(Installation/Unloaded) 10 D / 20 D
17 Yes / No
Cable Diameter 9.0 + - 0.5 mm
18 Yes / No
Lose Tube Diameter 3.0 + - 0.15 mm
19 Operating Yes / No
Temperature -40 Degree C to +70 Degree C
11. Fiber Optic LIU with Pigtails, Splice Trays& Splice Protectors (Fully Loaded)
Sr No. Specifications Requirement Compliance Deviation
1 Connector Type SC-Style, Simplex Yes / No
2 Operating temperature -40 Degree C to +85 Degree C Yes / No
3 Durability & color Yes / No
3 MM connectors 500 cycles, Beige Yes / No
4 SM connectors 220 cycles, Blue Yes / No
5 Ferrules Pre-radiused Ceramic Ferrules Yes / No
6 Attenuation Not more than 0.75 dB per mated pair Yes / No
7 Fiber Optic Patch panels
9 FMS- Front Patching / 1U • 19” / ETSI versions available Yes / No
Splicing Shelf
The FMS fiber management shelf series is Yes / No
ideal for high density front patching
applications.
Its compact design and high density capacity Yes / No
allows it to deliver carrier class fiber
management to central offices,POPs, FTTx,
mobile systems and LANs.
• High Density: Yes / No
1U: 12/24 Fiber terminations Yes / No
• Should be supplied loaded with secondary Yes / No
coated SC pigtails
• Mounting brackets can be placed in different Yes / No
positions
10 • Drawer concept allows for o Easy access to splicing tray Yes / No
o Easy access to back side of connector Yes / No
• Trays with hinges(book type) which allows Yes / No
facilitates easy fiber management and greater
access during installation and rework
• Fiber guides, radius controls & secure tie Yes / No
downs provided
11 Dimensions Width- 450 mm & Depth - 280 mm , Height – Yes / No
44 mm
12 Color RAL 7035 / Black Yes / No
12. SC to SC Patch Cord
Sr
No. Specifications Requirement Compliance Deviation
1 Make and Type SC to SC Duplex Fiber Optic Patch Cord 3 Mtr,9/125 Yes / No
Micron
2 Cable Sheath LSZH Yes / No
3 Cable Diameter Yes / No
2.5 mm twin zip
4 Ferrule Yes / No
Ceramic
5 Buffer Yes / No
.9 mm easy strip
6 Insertion Loss MAX .3 db Typical .15 db Yes / No
7 Return Loss > 45 db Yes / No
8 Temperature Range -25 Deg. C +70 Deg. C Yes / No
9 Yes / No
ROHS ROHS/ELV Compliant
SC to LC Patch Cord
Sr
No. Specifications Requirement Compliance Deviation
1 SC to LC Duplex Fiber Optic Patch Cords 3m 9/ 125 Yes / No
Make and Type– micron
2 Cable Sheath LSZH Yes / No
3 Yes / No
Cable Diameter 1.8 mm mini twin zip
4 Ferrule Ceramic Yes / No
5 Buffer .6 mm Yes / No
6 Return Loss > 45 db Yes / No
7 Insertion Loss .1 db Typical Max .3 db Yes / No
8 Yes / No
ROHS ROHS/ELV Compliant
23 Warranty
Owner seeks warranty for the installed cable plant from the OEM equipment supplier. Bidder shall
ensure that the OEM norms for supply, installation, testing and documentation as specified by the
OEM supplier shall be adhered to, provided those are in line with TIA / EIA standards and Owner
requirement specifications. The warranty shall be provided by the OEM vendor to Owner and
shall be administered in India. The duration of the warranty shall be for a minimum of 25 years
and shall cover the system performance, application assurance and the costs of the supply of
components and installation.