Slit lamp  By  praveen.p D.optom,B.optm
Slit lamp are used in the examination of the anterior segment of the eye . Where they allow the practitioner to perform a careful examination of cornea ,conjunctiva and lids. In modern instrument the microscope and light source are coupled so that the light shines on the same part of the eye that the microscope is focused .
This coupling  facilitates examination  of the eye . The instrument is called a slit lamp because in the normal mode of operation . The light source  produces a thin vertical slit of light at the eye . When this slit of light shines along a different axis to that of the microscope the clinician see a section of living eye.
Main parts of slit lamp Silt lamp microscopes Illumination  systems . Mechanical coupling .
Attachments of slit lamp Fundus  examination  Gonioscopy Tonometry Laser photo coagulation  Measuring the visual acuity in patients with hazy media .
Slit lamp microscopes The magnification of slit lamp microscope is usually with in the range of *6 to * 40 . At higher magnifications the small and often uncontrollable movement of the patient’s eye make the image jump around so much that an examination cannot be performed satisfactorily . This range of magnifications and the large working distance mean that compound rather than simple microscope have to be used .
In most basic form composed of microscopes are composed of   two optical elements . An objective and an eyepiece .[in the fig shown as two simple positive lenses. In reality the eye piece and occasionally the objective are composed of a series of lenses to reduce aberrations .
Range of magnifications The use of different objectives. The use of different eyepieces.  The Littmann- Galilean telescope principle . With a zoom system .
The use of different objectives This is one of the oldest and possibly still the most frequently used technique for obtaining  different magnifications . The different objectives are usually placed on a turret type of arrangement that allows them to be fairy rapidly changed during an examination .
The system is usually limited to two sets of objective lenses due to the confinements of space in and around the objective area of slit-lamp.
The use of different eye pieces  This technique is usually used in the cheaper slit lamps it is the only means of changing the magnification . It is not a very convenient technique as it requires the practitioner to pull out the current eye pieces and replace them Normally they are kept in a drawer attached to the instrument table .
More than two pairs of eye pieces to be provide with the slit lamp . The technique alone provides a very limited range of magnifications.
The littmann Galilean telescope principle The Galilean magnification changer developed by littmann [1950]  It is completely separate optics that sit nearly b the objective and eye piece lenses and does not require either of them to change . It provides a larger range of magnifications than the other technique .
Typically five via a turrent arrangement which is completely enclosed within the microscope’s body . It is called Galilean system because it utilizes Galilean telescopes to alter the magnification . The Galilean telescopes have two optical components a positive and a negative lens .
The parallel light rays both enters and leaves the system and under goes some degree of magnification which is dependent upon the power and separation of two lens . Galilean telescope fits with in the standard slit lamp microscope along with a rely lens in the manner . By reversing the order of the lenses in the telescope a different magnification can be achieve with out altering any optical elements.
Zoom systems Recently expensive slit-lamps have been produced with a zoom systems that allow a continuously variable degree of magnification . The Nikon instrument contains the zoom system with in the objective of the microscope and offers a range of  magnifications from *7 to *35.
Illumination systems The objective of the slit-lamp illumination system is to produce a bright light evenly illuminated ,finely focused ,adjustable slit of light at the eye . Almost all slit –lamp manufactures have adopted the koller illumination system .
Koller  illumination system  The filament of the bulb is imaged by the condenser lenses at or close to projector lens . The projector lens forms an image of the slit at the eye . The diameter of the projection lens is usually fairly small in size. This has two advantage :- first is keep the aberrations of the lens down ,which results in a better quality image .
Second :- it  increases the depth of focus of the slit and thereby produces a better optical section of the eye . While the optics of the condenser are not as critical as that of the other elements of the slit – lamp care must be taken in their design so as not to introduce too much chromatic aberration which will tend to cause fingers at the slit image .
To reduce the aberration is normally achieved by using two or more lenses in the condenser system . The light source used in slit –lamp illumination systems is a tungsten filament bulb . For safety reasons ,they are run on relatively low voltages  Slit-lamp can now be obtained with halogen filled bulbs.
The diag slit-lamp  It use a optic fiber to convey the light from a high –power halogen bulb . It is housed in a special fan cooled box to the slit lamp .
Advantage  Decrease the weight of slit- lamp  Allow it to be hand held by the practitioner .
Mechanical coupling of microscope and illumination system  Microscope and illumination system slit-lamp are linked together around a common axis or rotation that co insides with their focal plans. Microscope focused where the illumination system is focused . Without changing the focus the microscope and the illumination system can rotated around their axis .
The movement towards or away from the eye and from side to side is usually achieved via a joy stick . Up and down movement is obtained via some screw device .
Optom.praveenmails @gmail.com   Relax

More Related Content

What's hot

Bifocal Spectacles..
Bifocal Spectacles..Bifocal Spectacles..
Bifocal Spectacles..
Vishakh Nair
 
Bifocal lenses: types and principles
Bifocal lenses: types and principlesBifocal lenses: types and principles
Bifocal lenses: types and principles
Garima Poudel
 

What's hot (20)

Bifocal Spectacles..
Bifocal Spectacles..Bifocal Spectacles..
Bifocal Spectacles..
 
Frame measurementsand markings
Frame measurementsand markingsFrame measurementsand markings
Frame measurementsand markings
 
Frame types and parts
Frame types and partsFrame types and parts
Frame types and parts
 
Astigmatic lens
Astigmatic lensAstigmatic lens
Astigmatic lens
 
Slit Lamp Biomicroscopy
Slit  Lamp BiomicroscopySlit  Lamp Biomicroscopy
Slit Lamp Biomicroscopy
 
Lenticular lenses
Lenticular lensesLenticular lenses
Lenticular lenses
 
Slit lamp techniques.pptx
Slit lamp techniques.pptxSlit lamp techniques.pptx
Slit lamp techniques.pptx
 
The Slit lamp Biomicroscope
The Slit lamp BiomicroscopeThe Slit lamp Biomicroscope
The Slit lamp Biomicroscope
 
Bifocal lenses: types and principles
Bifocal lenses: types and principlesBifocal lenses: types and principles
Bifocal lenses: types and principles
 
Visual function assessment in low vision
Visual function assessment in low visionVisual function assessment in low vision
Visual function assessment in low vision
 
Maddox rod
Maddox rodMaddox rod
Maddox rod
 
Low vision aid
Low vision aidLow vision aid
Low vision aid
 
Magnifiers
MagnifiersMagnifiers
Magnifiers
 
Amsler grid
Amsler gridAmsler grid
Amsler grid
 
Potential acuity meter
Potential acuity meterPotential acuity meter
Potential acuity meter
 
Non contact tonometer ppt
Non contact tonometer pptNon contact tonometer ppt
Non contact tonometer ppt
 
Low vision aids magnification
Low vision aids magnificationLow vision aids magnification
Low vision aids magnification
 
Slit lamp biomicroscopy
Slit lamp biomicroscopySlit lamp biomicroscopy
Slit lamp biomicroscopy
 
Base curve
Base curveBase curve
Base curve
 
Optical aberrations
Optical aberrationsOptical aberrations
Optical aberrations
 

Viewers also liked

Viewers also liked (7)

laser lenses for retinal diseases
 laser lenses for retinal diseases laser lenses for retinal diseases
laser lenses for retinal diseases
 
Blepharitis : Overview and management
Blepharitis : Overview and managementBlepharitis : Overview and management
Blepharitis : Overview and management
 
Slit lamp in Ophthalmology
Slit lamp in OphthalmologySlit lamp in Ophthalmology
Slit lamp in Ophthalmology
 
Slit lamp – biomicroscopy of eye
Slit lamp – biomicroscopy of eyeSlit lamp – biomicroscopy of eye
Slit lamp – biomicroscopy of eye
 
Slit lamp biomicroscopy
Slit lamp biomicroscopySlit lamp biomicroscopy
Slit lamp biomicroscopy
 
Lenses of slit lamp biomicroscope & indirect ophthalmoscope.
Lenses of slit lamp biomicroscope & indirect ophthalmoscope.Lenses of slit lamp biomicroscope & indirect ophthalmoscope.
Lenses of slit lamp biomicroscope & indirect ophthalmoscope.
 
Looking deep into retina : indirect ophthalmoscopy and fundus drawing
Looking deep into retina : indirect ophthalmoscopy and fundus drawingLooking deep into retina : indirect ophthalmoscopy and fundus drawing
Looking deep into retina : indirect ophthalmoscopy and fundus drawing
 

Similar to Slit lamp

slit Lamp ppt-1.ppt
slit Lamp ppt-1.pptslit Lamp ppt-1.ppt
slit Lamp ppt-1.ppt
Gulafsha Saifi
 
slit-lamp-160212142229.pdf
slit-lamp-160212142229.pdfslit-lamp-160212142229.pdf
slit-lamp-160212142229.pdf
anju468752
 

Similar to Slit lamp (20)

Slit lamp biomicroscope
Slit lamp biomicroscopeSlit lamp biomicroscope
Slit lamp biomicroscope
 
Instrumentaion - MICROSCOPE
Instrumentaion - MICROSCOPEInstrumentaion - MICROSCOPE
Instrumentaion - MICROSCOPE
 
Slit lamp biomicroscopy and operating microscope
Slit lamp biomicroscopy and operating microscopeSlit lamp biomicroscopy and operating microscope
Slit lamp biomicroscopy and operating microscope
 
Slit lamp biomicroscopy
Slit lamp biomicroscopySlit lamp biomicroscopy
Slit lamp biomicroscopy
 
Slitlampexamination dinesh
Slitlampexamination dineshSlitlampexamination dinesh
Slitlampexamination dinesh
 
Slit lampbiomicroscopy-jinal & dhara
Slit lampbiomicroscopy-jinal & dharaSlit lampbiomicroscopy-jinal & dhara
Slit lampbiomicroscopy-jinal & dhara
 
Slitlamp bimicroscopy
Slitlamp bimicroscopy Slitlamp bimicroscopy
Slitlamp bimicroscopy
 
Slit lump biomicroscope
Slit lump biomicroscopeSlit lump biomicroscope
Slit lump biomicroscope
 
slit Lamp ppt-1.ppt
slit Lamp ppt-1.pptslit Lamp ppt-1.ppt
slit Lamp ppt-1.ppt
 
Slit lamp evaluation
Slit lamp evaluationSlit lamp evaluation
Slit lamp evaluation
 
slit-lamp-160212142229.pdf
slit-lamp-160212142229.pdfslit-lamp-160212142229.pdf
slit-lamp-160212142229.pdf
 
Slit lamp ..
Slit lamp ..Slit lamp ..
Slit lamp ..
 
light microscopy seminar.pptx
light microscopy seminar.pptxlight microscopy seminar.pptx
light microscopy seminar.pptx
 
SLIT LAMP
SLIT LAMPSLIT LAMP
SLIT LAMP
 
Compound microscope
Compound microscopeCompound microscope
Compound microscope
 
Microscope
 Microscope Microscope
Microscope
 
09 fundus camera
09 fundus camera09 fundus camera
09 fundus camera
 
Microscope .pptx
Microscope  .pptxMicroscope  .pptx
Microscope .pptx
 
Introduction to microscopy
Introduction to microscopyIntroduction to microscopy
Introduction to microscopy
 
Microscope and its types
Microscope and its typesMicroscope and its types
Microscope and its types
 

Recently uploaded

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
Joaquim Jorge
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 

Recently uploaded (20)

Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 

Slit lamp

  • 1. Slit lamp By praveen.p D.optom,B.optm
  • 2. Slit lamp are used in the examination of the anterior segment of the eye . Where they allow the practitioner to perform a careful examination of cornea ,conjunctiva and lids. In modern instrument the microscope and light source are coupled so that the light shines on the same part of the eye that the microscope is focused .
  • 3. This coupling facilitates examination of the eye . The instrument is called a slit lamp because in the normal mode of operation . The light source produces a thin vertical slit of light at the eye . When this slit of light shines along a different axis to that of the microscope the clinician see a section of living eye.
  • 4. Main parts of slit lamp Silt lamp microscopes Illumination systems . Mechanical coupling .
  • 5.
  • 6. Attachments of slit lamp Fundus examination Gonioscopy Tonometry Laser photo coagulation Measuring the visual acuity in patients with hazy media .
  • 7. Slit lamp microscopes The magnification of slit lamp microscope is usually with in the range of *6 to * 40 . At higher magnifications the small and often uncontrollable movement of the patient’s eye make the image jump around so much that an examination cannot be performed satisfactorily . This range of magnifications and the large working distance mean that compound rather than simple microscope have to be used .
  • 8. In most basic form composed of microscopes are composed of two optical elements . An objective and an eyepiece .[in the fig shown as two simple positive lenses. In reality the eye piece and occasionally the objective are composed of a series of lenses to reduce aberrations .
  • 9. Range of magnifications The use of different objectives. The use of different eyepieces. The Littmann- Galilean telescope principle . With a zoom system .
  • 10. The use of different objectives This is one of the oldest and possibly still the most frequently used technique for obtaining different magnifications . The different objectives are usually placed on a turret type of arrangement that allows them to be fairy rapidly changed during an examination .
  • 11. The system is usually limited to two sets of objective lenses due to the confinements of space in and around the objective area of slit-lamp.
  • 12. The use of different eye pieces This technique is usually used in the cheaper slit lamps it is the only means of changing the magnification . It is not a very convenient technique as it requires the practitioner to pull out the current eye pieces and replace them Normally they are kept in a drawer attached to the instrument table .
  • 13. More than two pairs of eye pieces to be provide with the slit lamp . The technique alone provides a very limited range of magnifications.
  • 14. The littmann Galilean telescope principle The Galilean magnification changer developed by littmann [1950] It is completely separate optics that sit nearly b the objective and eye piece lenses and does not require either of them to change . It provides a larger range of magnifications than the other technique .
  • 15. Typically five via a turrent arrangement which is completely enclosed within the microscope’s body . It is called Galilean system because it utilizes Galilean telescopes to alter the magnification . The Galilean telescopes have two optical components a positive and a negative lens .
  • 16. The parallel light rays both enters and leaves the system and under goes some degree of magnification which is dependent upon the power and separation of two lens . Galilean telescope fits with in the standard slit lamp microscope along with a rely lens in the manner . By reversing the order of the lenses in the telescope a different magnification can be achieve with out altering any optical elements.
  • 17. Zoom systems Recently expensive slit-lamps have been produced with a zoom systems that allow a continuously variable degree of magnification . The Nikon instrument contains the zoom system with in the objective of the microscope and offers a range of magnifications from *7 to *35.
  • 18. Illumination systems The objective of the slit-lamp illumination system is to produce a bright light evenly illuminated ,finely focused ,adjustable slit of light at the eye . Almost all slit –lamp manufactures have adopted the koller illumination system .
  • 19. Koller illumination system The filament of the bulb is imaged by the condenser lenses at or close to projector lens . The projector lens forms an image of the slit at the eye . The diameter of the projection lens is usually fairly small in size. This has two advantage :- first is keep the aberrations of the lens down ,which results in a better quality image .
  • 20. Second :- it increases the depth of focus of the slit and thereby produces a better optical section of the eye . While the optics of the condenser are not as critical as that of the other elements of the slit – lamp care must be taken in their design so as not to introduce too much chromatic aberration which will tend to cause fingers at the slit image .
  • 21. To reduce the aberration is normally achieved by using two or more lenses in the condenser system . The light source used in slit –lamp illumination systems is a tungsten filament bulb . For safety reasons ,they are run on relatively low voltages Slit-lamp can now be obtained with halogen filled bulbs.
  • 22.
  • 23. The diag slit-lamp It use a optic fiber to convey the light from a high –power halogen bulb . It is housed in a special fan cooled box to the slit lamp .
  • 24. Advantage Decrease the weight of slit- lamp Allow it to be hand held by the practitioner .
  • 25. Mechanical coupling of microscope and illumination system Microscope and illumination system slit-lamp are linked together around a common axis or rotation that co insides with their focal plans. Microscope focused where the illumination system is focused . Without changing the focus the microscope and the illumination system can rotated around their axis .
  • 26. The movement towards or away from the eye and from side to side is usually achieved via a joy stick . Up and down movement is obtained via some screw device .