Econet
             Where renewable and recoverable energy combine




Saving Energy,
Economy and
Environment with
Fläkt Woods
Our innovative Econet system is
                                                                     saving energy in several ways




T     he components in Fläkt Woods’ inno-
      vative Econet system are connected to-
gether to provide a more reliable and more
                                                          This is highly beneficial from an environmen-
                                                          tal point of view because much less energy
                                                          is used to transport the air through unneces-
efficient AHU system. Heat recovery, heating              sary components. Further development of the
and cooling are integrated into a common cir-             principle of energy recovery has also led to
cuit as heating/cooling coils, pumps, valves,             increases in efficiency of 50% compared with
pipe systems, insulation, etc. The result is a            traditional coil recovery systems.
shorter and more compact ventilation unit.




News
Dry-box solution (accessory)                              Twin pump solution (accessory)
High moisture combined with impurities in the             A twin pump solution is available for Econet. This
outdoor air can sometimes damage the outdoor              is the optimal solution for buildings where the
air filter. To protect the outdoor air filter, the pre-   ventilation is crucial for an ongoing process and
heater coil has traditionally been installed before       Econet must never stop. If one of the pumps has
the filter. This traditional solution reduces the         a breakdown, the twin pump solution sets the
energy recovery by 30%. Therefore, with Econet            other pump going.
dry-box solution both coils are connected in the
supply air instead. Advantages of this system
are that there is no impairment of the recovery,          Heat exchanger package
the system is self-regulating and the compo-              (accessory)
nents are protected from failure with the help of         In most cases some form of supplementary
Econet’s frost protection.                                heating or cooling is necessary. Instead of or-
                                                          dering cooling/heat exchanger separately, Fläkt
Controls                                                  Woods offer a complete heating exchanger
The control unit for Econet’s recovery function           package. This means that shorter delivery times
has been updated and has been given more flex-            are possible, and better precision is achieved in
ibility and better functionality. The control unit        the building.
can also be supplemented with its own efficien-
cy/energy measurement function.
Problem: Energy consumtions in buildings
 We spend approximately 90% of our time              heating and cooling through the ventilation
 indoors. A lot of energy resources are con-         system we have a lot to work with. Together
 sumed to maintain the right temperature             that means that you can make an impact on
 and air quality, which is becoming more and         somewhere about half of the total energy
 more important. On average, 68% of a build-         consumption of a building when focusing on
 ings energy needs are spent on heating, cool-       ventilation. That is something worth consid-
 ing and ventilation. Since we can affect both       ering!




 Solution: Energy efficient systems
Reusing energy
An obvious energy approach is to reuse the           were previously unusable can be used in the
heat and cooling. This mostly applies to reuse       Econet system.
of excisting energy in the exhaust air. It is best   An example of system optimization is to com-
achieved by using a recovery system with the         bine Econet with a chiller. The temperature of
highest recovery rate. Econet has a recovery         the cooling water is usually determined with
rate of 65 -75%.                                     reference to the requirement of the ventila-
                                                     tion unit, which leads to a relatively low cooling
System optimization                                  water temperature (6ºC). This means that the
Through its intelligent design, Econet is able to    efficiency of the chiller is limited. If an Econet
influence the entire energy chain. Thanks to the     system is used instead, the cooling water tem-
high degree of efficiency, the energy require-       perature can be increased significantly. This
ment can be reduced steeply. The entire energy       leads to a more efficient and smaller chiller,
chain from production, distribution to consump-      smaller pipe dimensions and pumps, i.e. econo-
tion can be optimized with the help of Econet,       mies in both investment costs and operating
thanks to the fact that energy sources that          costs are possible.




LCC sums it all up
                    SAVINGS
                                                     Within the industry we use an analysis ap-
COSTS




                                                     proach called “Life Cycle Cost“ when design-
                                                     ing ventilation systems. It balances the cost of
                                                     better components and smarter system con-
                                                     trol with savings in maintenance and energy
                                                     costs over the system’s life time.
                                                     Not surprisingly, a more expensive system
                                                     with better quality will be the cheapest solu-
                                                     tion in the long run as savings are made in
                                                     energy and maintenance.
                                          TIME
Heating                                                            Cooling

The design temperature in a heating system is traditionally        Econet can cool a building with other water temperatures
80/60°C. Econet is a low-temperature system, which means           that traditional systems. About 10ºC cooling water is in
that it is possible to use heating water at a temperature of       most cases sufficient as a feed temperature, whereas the
25-35ºC. This means that there is a possibility of utilizing hot   return temperature of the cooling water can be as high as
water that was previously considered to be unusable. The           22-26ºC. If a chiller is used, the cooling factor (COP) is in-
heat source for Econet can be the return water from district       creased as a consequence of a better working point. Econet
heating, waste/condenser heat or return water from radiator        is always prepared for cooling, which makes it possible to
systems, for example.                                              add cooling in a later stage.
Econet makes everybody a winner
       To lower the costs and care for the environment, Econet makes it possi-
       ble to use alternate energy sources instead of traditional. Thanks to this,
       Econet makes everybody a winner.



       Heat energy from a chiller                         Heat pump
       Refrigerators give off heat (condenser heat)       The lower the hot water temperature pro-
       when they produce cold. Liquid-borne con-          duced by a heat pump, the better the operat-
       denser heat from chillers is very often at a       ing economy. Econet can significantly lower
       low temperature (30-36ºC), which in the past       the hot water temperature down to a level
       has meant that it cannot be used and thus          of approximately 30ºC. This means that we
       goes to waste. Econet can utilize the waste        have a more efficient and smaller heat pump
       heat in order to heat the supply air. This way     with better operating economy.
       of saving energy is efficient in food shops
       and supermarkets.



       Energy from district heating                                               +23 °C

       Econet can utilize lower hot water tempera-
       tures, which makes it entirely possible to                               18 °C

       utilize the return heating water from the                                  27 °C             >30 ° C


       radiator system, for example. This means
       that the return heating water to the district
       heating network can be lowered to 20-25ºC                 -5 °C         +20 °C
       in optimal cases, which results in reduced
       energy costs.

       Energy from district cooling                       Energy from ground source cooling/
       In a district cooling system, it is important      seawater
       that the temperature of the return water           The temperature in the ground is largely
       to the district cooling system is as high as       constant (8-10ºC), i.e. it is more or less
       possible. In an Econet system, the highly          unaffected by the season. The temperature
       efficient coils can return the desired tem-        can rise slightly during the late autumn,
       perature level to the cooling water without        however, and this can lead to problems in
       over dimensioning the cooling coil in the          making use of the ground source cool-
       ventilation unit as in traditional systems.        ing. Econet can utilize temperatures of up
                                                          to 12ºC, which means that the system is
                                                          excellent for these environmentally friendly
                                                          energy sources.

                                                          Evaporative cooling
29°C                      19°C          24°C              The exhaust air unit can be supplemented
                                                          with a humidifier section where cooling
                                                          recovery is desired, and indirect evapora-
                               22°C
                                 11°C
                                                < 10 °C   tive cooling can be utilized in this way. This
                                                          method can significantly reduce the cooling
                                                          effect requirement from the chiller, which
              32°C            16°C                        results in a smaller chiller and lower operat-
                                                          ing costs.
Over 1000 Econet systems installed

Econet in superstores                             Econet in industries
The regrigerated counters emit waste heat         Within industry there is usually waste heat
that Econet can reuse. This energy is often       available. This heat is frequently sufficient for
wasted, but Econet uses it to heat the supply     Econet to heat the air, i.e. no primary heating
air.                                              is required to heat the air. Due to the recovery
                                                  principle employed by Econet it is possible to
References: ICA Maxi, Jönköping, Haninge,         position the units separately from each other,
Sweden/Prisma, Turku, Finland                     in addition there is no transfer of contaminated
                                                  exhaust air.


                                                  Reference: Volvo, Gothenburg, Sweden




Econet in offices and commercial                  Econet in hospitals
Buildings                                         In hospitals it is of severe importance that
The ventilation requirements in these types of    there is no leakage flow between supply- and
buildings vary during a day. Econet combined      exhaust air in order to keep the indoor air
with a VAV system creates a demand control-       hygienic. For the same reason, the ventilation
led ventilation, which gives a high comfort but   units also have to be easy to maintain. That is
saves energy when the rooms are empty. Coil       why only indirect energy recovery can be used,
recovery in Econet garantees no leakage flow      i.e coils. As the ventilation is in use day and
between supply and exhaust air and decreases      night reuse of energy is important in order to
the length of the unit. These buildings often     decrease the energy costs. Econet is the best
have access to ground source heating/cooling,     option for that.
and that makes Econet a perfect solution.



References: Akademiska Hus, Lund, Uppsala,        References: TYKS, Turku, Finland/St. Olav
Gothenburg, Sweden/Frankfurt Airport, Frank-      Hospital, Trondheim, Norway/Imperial College,
furt, Germany/NATO, Brussels, Belgium/Bris-       London, UK/Jansson Pharmacia, Antwerpen,
tol Museum, Bristol, UK                           Belgium
Increasing energy prices, legislation and a more environ-
mental consideration raise the demands and old tech-
niques are challenged with innovative solutions.

Our Econet system contains of an air handling unit and a prefabricated pump group that con-
trols the system. A heating exchanger package can be delivered as an accessory.




         The winning ideas of Econet

         - One common circuit for heating supply,         - Perfect for renewable energy sources
         cooling and heat recovery results in a di-       such as ground source water for cooling
         minished need of circulation pumps, pipe         and waste energy for heating.
         systems, valves, insulation etc. The result
         is a shorter unit and in most cases less         - The possibility of utilizing cooling recov-
         pressure loss.                                   ery reduces the cooling effect requirement
                                                          and evaporating cooling agent
         - A flexible control system that optimizes
         the reuse of energy.                             - Freeze-proof system

         - High recovery rate, especially suited for      - Separate air flows provide no air trans-
         variable air velocity systems.                   fer.

         - Exceptionally low temperature require-         - Our Dry-box solution protects the supply
         ment for hot water, allows the utilisation of    air filter without having a negative impact
         alternative sources of thermal energy.           on the recovery.

         - Ideal for district cooling/heating.
Fläkt Woods Group Brings Air to Life




                                                               Fläkt Woods is a global company providing solutions for ventilation and air
                                                               climate for buildings as well as fan solutions for Industry and Infrastructure
                                                               applications. Fläkt Woods Group has 20 manufacturing/engineering opertions
                                                               worldwide, sales offices in 30 countries and representation in 95 countries.




                                                               Head offices


                                                               Buildings Air Climate                                                     Industry Air Movement

                                                               Fläkt Woods AB                                                            Fläkt Woods
                                                               Kung Hans väg 12                                                          Axial Way
                                                               SE-192 68 SOLLENTUNA Sweden                                               COLCHESTER, CO4 5ZD
                                                               t +46 8 626 49 00                                                         United Kingdom
                                                               f +46 8 626 73 10                                                         t +44 1206 222 555
                                                                                                                                         f +44 1206 222 777


                                                               Sales Offices available World Wide –
                                                               See our website for details.

                                                               www.flaktwoods.com
FWG-Econet-GB-200806-8692 © Copyright 2008 Fläkt Woods Group




                                                               Due to a policy of continuous development and improvement the right is
                                                               reserved to supply products which may differ from those illustrated and
                                                               described in this publication. Certified dimensions will be supplied on
                                                               request on receipt of order.

Weitere ähnliche Inhalte

Was ist angesagt?

Assignment- report
Assignment- reportAssignment- report
Assignment- reportimwenhao
 
Hot water-plumbing-system
Hot water-plumbing-systemHot water-plumbing-system
Hot water-plumbing-systemnhmurad
 
Bs presentation slides
Bs presentation slidesBs presentation slides
Bs presentation slidesSyafiq Zariful
 
Matt Bullwinkel: Solar Hot Water Systems for the North Country
Matt Bullwinkel: Solar Hot Water Systems for the North CountryMatt Bullwinkel: Solar Hot Water Systems for the North Country
Matt Bullwinkel: Solar Hot Water Systems for the North CountryAnn Heidenreich
 
Renewable Energy Systems For Building Professionals Great Lakes Brewing Com...
Renewable Energy Systems For Building Professionals   Great Lakes Brewing Com...Renewable Energy Systems For Building Professionals   Great Lakes Brewing Com...
Renewable Energy Systems For Building Professionals Great Lakes Brewing Com...gogeisel
 
01 stephen-harrison solar heat pump
01 stephen-harrison solar heat pump01 stephen-harrison solar heat pump
01 stephen-harrison solar heat pumpCarlos Lehman
 
Energy saving by evaporative cooling in AHUs
Energy saving by evaporative cooling in AHUsEnergy saving by evaporative cooling in AHUs
Energy saving by evaporative cooling in AHUsCAREL Industries S.p.A
 
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...Fran Hereth
 
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET Journal
 
Design and Development of Combined system of air cooler and water chiller sys...
Design and Development of Combined system of air cooler and water chiller sys...Design and Development of Combined system of air cooler and water chiller sys...
Design and Development of Combined system of air cooler and water chiller sys...SANJAY NEOLIA
 
Thermal Engineering - II
Thermal Engineering - IIThermal Engineering - II
Thermal Engineering - IIGOBINATHS18
 
WSPE Geothermal Presentation
WSPE Geothermal PresentationWSPE Geothermal Presentation
WSPE Geothermal PresentationDan Rehbein
 
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...dbpublications
 
An Introduction to Air to water, Air Source, Heat Pump Systems
An Introduction to Air to water, Air Source, Heat Pump SystemsAn Introduction to Air to water, Air Source, Heat Pump Systems
An Introduction to Air to water, Air Source, Heat Pump SystemsSpaceAir
 
Air2o introduction Cairo May 17th 2016 v.1.2
Air2o introduction Cairo May 17th 2016 v.1.2Air2o introduction Cairo May 17th 2016 v.1.2
Air2o introduction Cairo May 17th 2016 v.1.2TAQAMISR
 
MEC441 - Solar Panel Cooling System
MEC441 - Solar Panel Cooling SystemMEC441 - Solar Panel Cooling System
MEC441 - Solar Panel Cooling SystemLuis Lituma
 
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...rahulmonikasharma
 
Energy Efficiency Potential in Food & Beverage Industries in Nepal
Energy Efficiency Potential in Food & Beverage Industries in NepalEnergy Efficiency Potential in Food & Beverage Industries in Nepal
Energy Efficiency Potential in Food & Beverage Industries in Nepaleecfncci
 
Compact solar water heater - micoe
Compact solar water heater - micoeCompact solar water heater - micoe
Compact solar water heater - micoeGoogle
 

Was ist angesagt? (20)

Assignment- report
Assignment- reportAssignment- report
Assignment- report
 
Hot water-plumbing-system
Hot water-plumbing-systemHot water-plumbing-system
Hot water-plumbing-system
 
Bs presentation slides
Bs presentation slidesBs presentation slides
Bs presentation slides
 
Matt Bullwinkel: Solar Hot Water Systems for the North Country
Matt Bullwinkel: Solar Hot Water Systems for the North CountryMatt Bullwinkel: Solar Hot Water Systems for the North Country
Matt Bullwinkel: Solar Hot Water Systems for the North Country
 
Renewable Energy Systems For Building Professionals Great Lakes Brewing Com...
Renewable Energy Systems For Building Professionals   Great Lakes Brewing Com...Renewable Energy Systems For Building Professionals   Great Lakes Brewing Com...
Renewable Energy Systems For Building Professionals Great Lakes Brewing Com...
 
01 stephen-harrison solar heat pump
01 stephen-harrison solar heat pump01 stephen-harrison solar heat pump
01 stephen-harrison solar heat pump
 
Swh 0209
Swh 0209Swh 0209
Swh 0209
 
Energy saving by evaporative cooling in AHUs
Energy saving by evaporative cooling in AHUsEnergy saving by evaporative cooling in AHUs
Energy saving by evaporative cooling in AHUs
 
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...
Field Guide to Solar DHW Systems for Multifamily Buildings-edit3 11-11-13 wit...
 
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
 
Design and Development of Combined system of air cooler and water chiller sys...
Design and Development of Combined system of air cooler and water chiller sys...Design and Development of Combined system of air cooler and water chiller sys...
Design and Development of Combined system of air cooler and water chiller sys...
 
Thermal Engineering - II
Thermal Engineering - IIThermal Engineering - II
Thermal Engineering - II
 
WSPE Geothermal Presentation
WSPE Geothermal PresentationWSPE Geothermal Presentation
WSPE Geothermal Presentation
 
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...
Solar Heating System for Building – Water Heating, Pipe Dimension and Insulat...
 
An Introduction to Air to water, Air Source, Heat Pump Systems
An Introduction to Air to water, Air Source, Heat Pump SystemsAn Introduction to Air to water, Air Source, Heat Pump Systems
An Introduction to Air to water, Air Source, Heat Pump Systems
 
Air2o introduction Cairo May 17th 2016 v.1.2
Air2o introduction Cairo May 17th 2016 v.1.2Air2o introduction Cairo May 17th 2016 v.1.2
Air2o introduction Cairo May 17th 2016 v.1.2
 
MEC441 - Solar Panel Cooling System
MEC441 - Solar Panel Cooling SystemMEC441 - Solar Panel Cooling System
MEC441 - Solar Panel Cooling System
 
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...
Performance Improvement of Solar PV Cells using Various Cooling Methods: A Re...
 
Energy Efficiency Potential in Food & Beverage Industries in Nepal
Energy Efficiency Potential in Food & Beverage Industries in NepalEnergy Efficiency Potential in Food & Beverage Industries in Nepal
Energy Efficiency Potential in Food & Beverage Industries in Nepal
 
Compact solar water heater - micoe
Compact solar water heater - micoeCompact solar water heater - micoe
Compact solar water heater - micoe
 

Andere mochten auch

Combi Cooler Tech Detail Gb 8733
Combi Cooler Tech Detail Gb 8733Combi Cooler Tech Detail Gb 8733
Combi Cooler Tech Detail Gb 8733Bartosz Pijawski
 
Combi Cooler Presentation Pl
Combi Cooler Presentation PlCombi Cooler Presentation Pl
Combi Cooler Presentation PlBartosz Pijawski
 
Combi Cooler - Energy efficient cooling unit for air handling units
Combi Cooler - Energy efficient cooling unit for air handling unitsCombi Cooler - Energy efficient cooling unit for air handling units
Combi Cooler - Energy efficient cooling unit for air handling unitsBartosz Pijawski
 
Econet Presentation 2007 Eng
Econet Presentation 2007 EngEconet Presentation 2007 Eng
Econet Presentation 2007 EngBartosz Pijawski
 
Eu Air Handling Unit Gb 200809
Eu Air Handling Unit Gb 200809Eu Air Handling Unit Gb 200809
Eu Air Handling Unit Gb 200809Bartosz Pijawski
 
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)Smoke Mater Smia Technical Catalogue 2009 09 (Eng)
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)Bartosz Pijawski
 

Andere mochten auch (8)

Combi Cooler Tech Detail Gb 8733
Combi Cooler Tech Detail Gb 8733Combi Cooler Tech Detail Gb 8733
Combi Cooler Tech Detail Gb 8733
 
Combi Cooler Presentation Pl
Combi Cooler Presentation PlCombi Cooler Presentation Pl
Combi Cooler Presentation Pl
 
Combi Cooler - Energy efficient cooling unit for air handling units
Combi Cooler - Energy efficient cooling unit for air handling unitsCombi Cooler - Energy efficient cooling unit for air handling units
Combi Cooler - Energy efficient cooling unit for air handling units
 
IQ Stars
IQ StarsIQ Stars
IQ Stars
 
Econet Presentation 2007 Eng
Econet Presentation 2007 EngEconet Presentation 2007 Eng
Econet Presentation 2007 Eng
 
Eu Air Handling Unit Gb 200809
Eu Air Handling Unit Gb 200809Eu Air Handling Unit Gb 200809
Eu Air Handling Unit Gb 200809
 
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)Smoke Mater Smia Technical Catalogue 2009 09 (Eng)
Smoke Mater Smia Technical Catalogue 2009 09 (Eng)
 
Bms system basic
Bms system  basicBms system  basic
Bms system basic
 

Ähnlich wie Econet Marketing Brochure 8692 Gb 2008 08

Energy Efficient Equipments in building architecture presentation
Energy Efficient Equipments in building architecture presentationEnergy Efficient Equipments in building architecture presentation
Energy Efficient Equipments in building architecture presentationShailja km
 
Energy efficint colling
Energy efficint collingEnergy efficint colling
Energy efficint collingpaneliya sagar
 
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoon
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoonP Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoon
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoonshakamie
 
2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.pptRAMIREDDY49
 
renewable resources in buildings case study
renewable resources in buildings case studyrenewable resources in buildings case study
renewable resources in buildings case studyBarsha
 
Solar cooling has lots of advantages
Solar cooling has lots of advantagesSolar cooling has lots of advantages
Solar cooling has lots of advantagesFrans Romeijn
 
Gas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part LGas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part LNuTech Renewables Ltd
 
Heat Exchanger recuperators
Heat Exchanger  recuperators  Heat Exchanger  recuperators
Heat Exchanger recuperators Ali Abdullah
 
Aircon Saver
Aircon SaverAircon Saver
Aircon Saverselengia
 
Geothermal Heat for Radiant Floors
Geothermal Heat for Radiant FloorsGeothermal Heat for Radiant Floors
Geothermal Heat for Radiant FloorsApple Built Homes
 
Academic project report
Academic project reportAcademic project report
Academic project reportravi wankhede
 
Energy efficient cooling
Energy  efficient  coolingEnergy  efficient  cooling
Energy efficient coolingrohit goud
 
Boiler doc 01 intro
Boiler doc 01   introBoiler doc 01   intro
Boiler doc 01 introMars Tsani
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlHossam Zein
 
Air Conditioning case study
Air Conditioning case studyAir Conditioning case study
Air Conditioning case studySona Rawat
 

Ähnlich wie Econet Marketing Brochure 8692 Gb 2008 08 (20)

Energy Efficient Equipments in building architecture presentation
Energy Efficient Equipments in building architecture presentationEnergy Efficient Equipments in building architecture presentation
Energy Efficient Equipments in building architecture presentation
 
Energy efficint colling
Energy efficint collingEnergy efficint colling
Energy efficint colling
 
Adiabetic econet
Adiabetic econetAdiabetic econet
Adiabetic econet
 
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoon
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoonP Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoon
P Sundelin: Econet - matalaenergiajärjestelmä ilmanvaihtoon
 
2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt
 
renewable resources in buildings case study
renewable resources in buildings case studyrenewable resources in buildings case study
renewable resources in buildings case study
 
Solar cooling has lots of advantages
Solar cooling has lots of advantagesSolar cooling has lots of advantages
Solar cooling has lots of advantages
 
SP1037 TECHFEST
SP1037 TECHFESTSP1037 TECHFEST
SP1037 TECHFEST
 
Gas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part LGas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part L
 
Heat Exchanger recuperators
Heat Exchanger  recuperators  Heat Exchanger  recuperators
Heat Exchanger recuperators
 
Aircon Saver
Aircon SaverAircon Saver
Aircon Saver
 
Geothermal Heat for Radiant Floors
Geothermal Heat for Radiant FloorsGeothermal Heat for Radiant Floors
Geothermal Heat for Radiant Floors
 
Low cost active heat storage
Low cost active heat storageLow cost active heat storage
Low cost active heat storage
 
Academic project report
Academic project reportAcademic project report
Academic project report
 
Energy efficient cooling
Energy  efficient  coolingEnergy  efficient  cooling
Energy efficient cooling
 
195
195195
195
 
Assigment2
Assigment2Assigment2
Assigment2
 
Boiler doc 01 intro
Boiler doc 01   introBoiler doc 01   intro
Boiler doc 01 intro
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Air Conditioning case study
Air Conditioning case studyAir Conditioning case study
Air Conditioning case study
 

Econet Marketing Brochure 8692 Gb 2008 08

  • 1. Econet Where renewable and recoverable energy combine Saving Energy, Economy and Environment with Fläkt Woods
  • 2. Our innovative Econet system is saving energy in several ways T he components in Fläkt Woods’ inno- vative Econet system are connected to- gether to provide a more reliable and more This is highly beneficial from an environmen- tal point of view because much less energy is used to transport the air through unneces- efficient AHU system. Heat recovery, heating sary components. Further development of the and cooling are integrated into a common cir- principle of energy recovery has also led to cuit as heating/cooling coils, pumps, valves, increases in efficiency of 50% compared with pipe systems, insulation, etc. The result is a traditional coil recovery systems. shorter and more compact ventilation unit. News Dry-box solution (accessory) Twin pump solution (accessory) High moisture combined with impurities in the A twin pump solution is available for Econet. This outdoor air can sometimes damage the outdoor is the optimal solution for buildings where the air filter. To protect the outdoor air filter, the pre- ventilation is crucial for an ongoing process and heater coil has traditionally been installed before Econet must never stop. If one of the pumps has the filter. This traditional solution reduces the a breakdown, the twin pump solution sets the energy recovery by 30%. Therefore, with Econet other pump going. dry-box solution both coils are connected in the supply air instead. Advantages of this system are that there is no impairment of the recovery, Heat exchanger package the system is self-regulating and the compo- (accessory) nents are protected from failure with the help of In most cases some form of supplementary Econet’s frost protection. heating or cooling is necessary. Instead of or- dering cooling/heat exchanger separately, Fläkt Controls Woods offer a complete heating exchanger The control unit for Econet’s recovery function package. This means that shorter delivery times has been updated and has been given more flex- are possible, and better precision is achieved in ibility and better functionality. The control unit the building. can also be supplemented with its own efficien- cy/energy measurement function.
  • 3. Problem: Energy consumtions in buildings We spend approximately 90% of our time heating and cooling through the ventilation indoors. A lot of energy resources are con- system we have a lot to work with. Together sumed to maintain the right temperature that means that you can make an impact on and air quality, which is becoming more and somewhere about half of the total energy more important. On average, 68% of a build- consumption of a building when focusing on ings energy needs are spent on heating, cool- ventilation. That is something worth consid- ing and ventilation. Since we can affect both ering! Solution: Energy efficient systems Reusing energy An obvious energy approach is to reuse the were previously unusable can be used in the heat and cooling. This mostly applies to reuse Econet system. of excisting energy in the exhaust air. It is best An example of system optimization is to com- achieved by using a recovery system with the bine Econet with a chiller. The temperature of highest recovery rate. Econet has a recovery the cooling water is usually determined with rate of 65 -75%. reference to the requirement of the ventila- tion unit, which leads to a relatively low cooling System optimization water temperature (6ºC). This means that the Through its intelligent design, Econet is able to efficiency of the chiller is limited. If an Econet influence the entire energy chain. Thanks to the system is used instead, the cooling water tem- high degree of efficiency, the energy require- perature can be increased significantly. This ment can be reduced steeply. The entire energy leads to a more efficient and smaller chiller, chain from production, distribution to consump- smaller pipe dimensions and pumps, i.e. econo- tion can be optimized with the help of Econet, mies in both investment costs and operating thanks to the fact that energy sources that costs are possible. LCC sums it all up SAVINGS Within the industry we use an analysis ap- COSTS proach called “Life Cycle Cost“ when design- ing ventilation systems. It balances the cost of better components and smarter system con- trol with savings in maintenance and energy costs over the system’s life time. Not surprisingly, a more expensive system with better quality will be the cheapest solu- tion in the long run as savings are made in energy and maintenance. TIME
  • 4. Heating Cooling The design temperature in a heating system is traditionally Econet can cool a building with other water temperatures 80/60°C. Econet is a low-temperature system, which means that traditional systems. About 10ºC cooling water is in that it is possible to use heating water at a temperature of most cases sufficient as a feed temperature, whereas the 25-35ºC. This means that there is a possibility of utilizing hot return temperature of the cooling water can be as high as water that was previously considered to be unusable. The 22-26ºC. If a chiller is used, the cooling factor (COP) is in- heat source for Econet can be the return water from district creased as a consequence of a better working point. Econet heating, waste/condenser heat or return water from radiator is always prepared for cooling, which makes it possible to systems, for example. add cooling in a later stage.
  • 5. Econet makes everybody a winner To lower the costs and care for the environment, Econet makes it possi- ble to use alternate energy sources instead of traditional. Thanks to this, Econet makes everybody a winner. Heat energy from a chiller Heat pump Refrigerators give off heat (condenser heat) The lower the hot water temperature pro- when they produce cold. Liquid-borne con- duced by a heat pump, the better the operat- denser heat from chillers is very often at a ing economy. Econet can significantly lower low temperature (30-36ºC), which in the past the hot water temperature down to a level has meant that it cannot be used and thus of approximately 30ºC. This means that we goes to waste. Econet can utilize the waste have a more efficient and smaller heat pump heat in order to heat the supply air. This way with better operating economy. of saving energy is efficient in food shops and supermarkets. Energy from district heating +23 °C Econet can utilize lower hot water tempera- tures, which makes it entirely possible to 18 °C utilize the return heating water from the 27 °C >30 ° C radiator system, for example. This means that the return heating water to the district heating network can be lowered to 20-25ºC -5 °C +20 °C in optimal cases, which results in reduced energy costs. Energy from district cooling Energy from ground source cooling/ In a district cooling system, it is important seawater that the temperature of the return water The temperature in the ground is largely to the district cooling system is as high as constant (8-10ºC), i.e. it is more or less possible. In an Econet system, the highly unaffected by the season. The temperature efficient coils can return the desired tem- can rise slightly during the late autumn, perature level to the cooling water without however, and this can lead to problems in over dimensioning the cooling coil in the making use of the ground source cool- ventilation unit as in traditional systems. ing. Econet can utilize temperatures of up to 12ºC, which means that the system is excellent for these environmentally friendly energy sources. Evaporative cooling 29°C 19°C 24°C The exhaust air unit can be supplemented with a humidifier section where cooling recovery is desired, and indirect evapora- 22°C 11°C < 10 °C tive cooling can be utilized in this way. This method can significantly reduce the cooling effect requirement from the chiller, which 32°C 16°C results in a smaller chiller and lower operat- ing costs.
  • 6. Over 1000 Econet systems installed Econet in superstores Econet in industries The regrigerated counters emit waste heat Within industry there is usually waste heat that Econet can reuse. This energy is often available. This heat is frequently sufficient for wasted, but Econet uses it to heat the supply Econet to heat the air, i.e. no primary heating air. is required to heat the air. Due to the recovery principle employed by Econet it is possible to References: ICA Maxi, Jönköping, Haninge, position the units separately from each other, Sweden/Prisma, Turku, Finland in addition there is no transfer of contaminated exhaust air. Reference: Volvo, Gothenburg, Sweden Econet in offices and commercial Econet in hospitals Buildings In hospitals it is of severe importance that The ventilation requirements in these types of there is no leakage flow between supply- and buildings vary during a day. Econet combined exhaust air in order to keep the indoor air with a VAV system creates a demand control- hygienic. For the same reason, the ventilation led ventilation, which gives a high comfort but units also have to be easy to maintain. That is saves energy when the rooms are empty. Coil why only indirect energy recovery can be used, recovery in Econet garantees no leakage flow i.e coils. As the ventilation is in use day and between supply and exhaust air and decreases night reuse of energy is important in order to the length of the unit. These buildings often decrease the energy costs. Econet is the best have access to ground source heating/cooling, option for that. and that makes Econet a perfect solution. References: Akademiska Hus, Lund, Uppsala, References: TYKS, Turku, Finland/St. Olav Gothenburg, Sweden/Frankfurt Airport, Frank- Hospital, Trondheim, Norway/Imperial College, furt, Germany/NATO, Brussels, Belgium/Bris- London, UK/Jansson Pharmacia, Antwerpen, tol Museum, Bristol, UK Belgium
  • 7. Increasing energy prices, legislation and a more environ- mental consideration raise the demands and old tech- niques are challenged with innovative solutions. Our Econet system contains of an air handling unit and a prefabricated pump group that con- trols the system. A heating exchanger package can be delivered as an accessory. The winning ideas of Econet - One common circuit for heating supply, - Perfect for renewable energy sources cooling and heat recovery results in a di- such as ground source water for cooling minished need of circulation pumps, pipe and waste energy for heating. systems, valves, insulation etc. The result is a shorter unit and in most cases less - The possibility of utilizing cooling recov- pressure loss. ery reduces the cooling effect requirement and evaporating cooling agent - A flexible control system that optimizes the reuse of energy. - Freeze-proof system - High recovery rate, especially suited for - Separate air flows provide no air trans- variable air velocity systems. fer. - Exceptionally low temperature require- - Our Dry-box solution protects the supply ment for hot water, allows the utilisation of air filter without having a negative impact alternative sources of thermal energy. on the recovery. - Ideal for district cooling/heating.
  • 8. Fläkt Woods Group Brings Air to Life Fläkt Woods is a global company providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and Infrastructure applications. Fläkt Woods Group has 20 manufacturing/engineering opertions worldwide, sales offices in 30 countries and representation in 95 countries. Head offices Buildings Air Climate Industry Air Movement Fläkt Woods AB Fläkt Woods Kung Hans väg 12 Axial Way SE-192 68 SOLLENTUNA Sweden COLCHESTER, CO4 5ZD t +46 8 626 49 00 United Kingdom f +46 8 626 73 10 t +44 1206 222 555 f +44 1206 222 777 Sales Offices available World Wide – See our website for details. www.flaktwoods.com FWG-Econet-GB-200806-8692 © Copyright 2008 Fläkt Woods Group Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order.