5. Saving Your Energy -Means- Reducing Your Costs -Leads to- Protecting the Environment
6.
7.
8.
9.
10.
11.
12.
13. Greenhouse effect? 4% absorbed by clouds. 17% reflected by clouds. 6% reflected by surface. 19% absorbed by water vapor, dust Earth 100% 46% absorbed by ground Earth acts as Solar Collector
14. ENERGY COST REDUCTION Option 1 Electrical Distribution Correction Option 2 Motor Efficiency Improvement Option 3 System Matching and Process optimization Energy Efficient Equipments ~ Energy Efficient Procedures
15.
16. PHASE IMBALANCE Phase imbalance should be within 1% to avoid de-rating of the motor. If the measured line voltages are 403, 406, and 415 volts, the average is 408 volts. VOLTAGE IMBALANCE IS: [(408 – 403) / 408 ] x 100 = 1.225 % Current imbalance creates voltage imbalance
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30. HOW TO IMPROVE PF When all the reactive power demand of the system is provided by installed capacitors and reactive power utilization from DISCOs (power source) is zero, we say power factor improvement is 100%, 0.98 Optimum
43. SYSTEM MATCHING AND PROCESS OPTIMIZATION Change or reconfigure the process or application so that less input power is required. Downsize the over sized pumps, fans, compressors or other driven loads if possible. Install more efficient mechanical subsystems. Check that coupling, gearbox, fan or pump must be energy efficient. Electric Motors
44. PROCESS OPTIMIZATION Reducing circulation fan speed from 80% to 60%; power consumption was reduced by 54 %. REGULATE FAN SPEEDS WITH TEMPERATURE Unwise use of machines Average Speed Reduction 10% 20% 30% 40% 50% 60% Potential Energy Savings 22% 44% 61% 73% 83% 91%
45.
46.
47. LIGHT OUTPUT- T8 & T5 – All lights with ECG Lighting System T8 Luminux Plus T5 (at 35 0 C) T8 Luminux Plus T5 (at 35 0 C) T8 Luminux Plus T5 (at 35 0 C) Power 18 Watt 14 Watt 36 Watt 28 Watt 58 Watt 35 Watt lm 1,300 1,350 3,200 2,900 5,000 3,650 lm / W 72,2 96,4 88,8 103,6 86,2 104,3
49. ENERGY SAVING IN LIGHTING T-12 lighting system up gradation to T-8 = (kWh saved/year)(Rs./kWh ) = (20,000 kWh saved/year)(8 Rs./kWh ) = 160,000 Rs. = (# fixtures) [(40 watts-T12)—(36 watts-T8 )] = (1000) [( 40 watts )-( 36 watts )] = 4 kW = (kW savings)(Annual Operating Hours) = (4 kW)(8000 hours/year) = 32,000. kWh/year KW Savings KWh Savings Rs. Savings per year Lighting System
50.
51.
52. Hand operated machines; like Generators Water pumps Washing machines Flour grinding machines etc… THINK ABOUT IT . World population of 6B, increasing to perhaps 10B by 2050 FUTURE BUSINESS???