1. Marshall Ryerson Andek Territory Manager 7440 Lime Hollow Dr SE Grand Rapids, MI 49546 616-299-1751 [email_address] 22 Year Old EPDM Andek Roof Restoration www.andek.com
2. Ponding – The batten bars, cover strips, and seams produce raised areas that let water pool and often cause EPDM seam failures. These areas are easily repaired using Andek products which are not affected by ponding water. Andek products are UL and FM rated offering a light reflective Energy Star rating with a 10 yr renewable manufactures watertight warranty. Seam Failure – EPDM seam failures occur as the material shrinks and lose elasticity. Seams are easily repaired using reinforced Andek Roof Fab material over the seams, while the black roof is turned white using UL and FM rated products with a light reflective Energy Star rating which can provide a 10 yr renewable manufactures watertight warranty . Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - mrc11@comcast.net
3.
4. Black EPDM Temp 204.5°F at base of AC unit Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - mrc11@comcast.net May 20, 2009 80 Degree Air Temp Scrim Reinforced Andek ROOFAB embedded in Andek POLAROOF RAC over all EPDM Field Seams. 50 square feet per gallon coverage (30 wet mils) Sample of Andek ROOFAB embedded in Andek RAC Existing smooth surface EPDM roof can be left in place and used as a canvass to accept the new Andek system. New waterproofing system will incorporate the thickness of the existing EPDM plus the thickness of the new Andek system and will qualify for a new 10 year manufacturer’s warranty which may be renewable. The existing roof and insulation can be reused and saved while protecting precious landfill space. Sustainable Roof – Seams beginning to separate Out of Warranty - Reaching useful service life EPDM Roofing 22 Yrs Old
5. Andek Product Sample Thermal Image Shot EPDM vs . Andek Black EPDM Temp 195.5°F May 20, 2009 80 Degree Air Temp Andek RAC Coating Temp over EPDM 77.5°F Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - mrc11@comcast.net Scrim Reinforced Andek ROOFAB embedded in Andek POLAROOF RAC over all EPDM Field Seams. 50 square feet per gallon coverage (30 wet mils) Sample of Andek ROOFAB embedded in Andek RAC Existing smooth surface EPDM roof can be left in place and used as a canvass to accept the new Andek system. New waterproofing system will incorporate the thickness of the existing EPDM plus the thickness of the new Andek system and will qualify for a new 10 year manufacturer’s warranty which may be renewable. The existing roof and insulation can be reused and saved while protecting precious landfill space. Sustainable Roof – Seams beginning to separate Out of Warranty - Reaching useful service life EPDM Roofing 22 Yrs Old