4. Radiation. Safety.
The DMC 3000| New Features and Improvements
New Features
Vibration Alarms
Pocket and Belt Clips
Military Grade EMI Immunity
Multiple LED Alarm Indicators
5. Radiation. Safety.
The DMC 3000 | New Features and Improvements
Improvements
Larger Display
Louder Speaker
Ultra Bright LED
Expanded Energy Range
Uses a AAA Battery
9-11 Month Battery Life
6. Radiation. Safety.
The DMC 3000 | Overview
Display Features
- Large viewing angle
- 6-8 alpha-numeric digits
- 3 top mounted LED’s for alarms and dose increments
- Two push buttons for ease-of-use
7. Radiation. Safety.
The DMC 3000 | Overview
Alarm Features
- Alarming speaker with level > 85 dB (A)
at 30cm, frequency < 4800 Hz
- Tactile alarm (vibrator)
- High efficiency red flash LED on front of device
- Dose and dose rate alarms
- Alarm on battery removal
8. Radiation. Safety.
The DMC 3000 | Overview
Histogram Features
- Histogram is saved to non-volatile memory (EEPROM)
- Workers dose (1uSv/0.1 mrem)
- Stored in increments 10s, 1 min, 10 min, 1h, or 24h
- Event log marks events during the selected time period
- Stores data for several consecutive workers’ entries and exits
9. Radiation. Safety.
The DMC 3000 | Overview
Measurement Characteristics
Energy Response: 15 keV to 7 MeV at better than +/- 20%
Accuracy: <+/- 10% for Cs137 @ 21mSv/h
<= +/- 15% for Am241 and X:16keV
Measurement Range: 0.1uSv/hr to 10 Sv/hr (0.01mrem/h - 1000R/h)
Dose Display: 1uSv/hr to 10Sv/hr (0.1mrem/h - 1000R/h)
Rate Display: 0.01mSv/h to 10 Sv/h (1mrem/h to 1000R/h)
Dose Rate Linearity: <-/+ 20% up to 10 Sv/h
(1000 rem/h) for Co-60 & X-Ray H30 20 keV
Pulsed Field Linearity: <-/+ 20% up to 6 Sv/h
(600 rem/h) for Pulsed X-Rays, 20msec pulse
width, 1, 10 & 20 pulses/sec
Saturation: Indication above 6 Sv/h (600 rem/h)
Units Displayed: mSv, uSv, mrem
16. Radiation. Safety.
The DMC 3000 | Accessories
Wall Mounted Wireless
Wireless Desktop USB Reader
USB Reader
17. Radiation. Safety.
The DMC 3000 | Accessories
Transmits Real Time Data to
Telemetry Receivers
Low-power Optimized for AAA
Battery with Long Life
External Power Options and
900 MHz or 2.4 GHz
Frequencies
Telemetry Module
18. Radiation. Safety.
The DMC 3000 | Accessories
Upgrades to iDC Calibrator
New Carriage for IRD Calibrator
For DMC 3000
19. Radiation. Safety.
The DMC 3000 | Where to Buy
Europe Americas Asia
Mirion Technologies (MGPI), S.A. Mirion Technologies (MGPI), Inc. Mirion Technologies Shanghai
Lieu-dit Cales, route d’Eyguieres, 5000 Highlands Pkwy, Suite 150 Room 801, 78 Jianchang San Lu
13113 Lamanon Smyrna GA, 30082 Zhabei District, Shanghai 200436
France USA China
T: +33 490 595959 T: +1 770 432 2744 T: +86 21 6180 6920