888/890
Enter the Titrando world
888 Titrando – potentiometric titrator
    890 Titrando – Karl Fischer titrator




2
• Touch Control with large color screen


• Titration software PC Control or tiamoTM for operation via PC


• Intuitive operation


• Intelligent Exchange Units


• Intelligent electrodes «iTrodes» for the 888 Titrando


• Potentiometric titration with the 888 Titrando


• Karl Fischer titration with the 890 Titrando


• Sample Processor control


• Lab Link for Intranet and Internet


• Online help


• Complies with FDA regulation 21 CFR Part 11


• USB interfaces for sample changer, printer, PC keyboard, barcode reader...




                                                                               3
Overview of the 888 Titrando and
    890 Titrando




                                                           888 Titrando                 890 Titrando
    Intelligent dosing elements for titration          1 integrated Dosimat         1 integrated Dosimat
                                                        for Exchange Unit            for Exchange Unit
    Additional dosing elements (dispensing only)          3 x 805 Dosimat              3 x 805 Dosimat
                                                        with Exchange Unit           with Exchange Unit
                                                          3 x 800 Dosino               3 x 800 Dosino
                                                         with Dosing Unit              with Dosing Unit
    Intelligent Exchange Unit with integral data
                                                                              Yes
    chip
    Increments per cylinder volume (Exchange Unit)                         20’000
    Measuring interface for pH, U/mV, T/°C                      1                            –
    Intelligent electrodes «iTrodes»                            1                            –
    Measuring input for polarizable electrodes                                1
    Operation, dialog                                      Touch Control, PC Control or tiamoTM
    Stirrers, titration stand                          801 Stirrer (magnetic) or 802 Stirrer (rod) with
                                                              804 Ti Stand or 803 Ti Stand (KF)
    Connections for stirrers and intelligent dosing                  4 MSB connections
    elements                                                 (Metrohm Serial Bus, Daisy Chain)
    Connection for sample changer                                 1 sample changer via USB
    Connections for balances, printer, PC,                 Via 2 USB Slave Ports, RS-232/USB Box
    PC keyboard, barcode reader and/or Lab Link                           (option)
    Temperature sensor                                   Pt 1000 or NTC                     –
    Differential amplifier                                    Option                        –
    Real-time curve display on Touch Control or
                                                                              Yes
    PC screen
    DET     Dynamic equivalence-point titration                Yes                           –
    MET     Monotonic equivalence-point titration              Yes                           –
    SET     Titration to preset endpoints with
                                                               Yes                           –
            automatic conditioning
    KFT     Volumetric Karl Fischer titration with
                                                                –                           Yes
            automatic conditioning
    MEAS Measuring mode for pH, U/mV, T/°C,
                                                               Yes                           –
            Ipol, Upol
    CAL     Calibration with automatic buffer
                                                               Yes                           –
            recognition
    Additional titration curve evaluation for: fixed
                                                               Yes                           –
    endpoints, pK values (HNP)
    Comprehensive GLP/GMP functions; complies
                                                                              Yes
    with FDA 21 CFR Part 11




4
Uniquely intelligent –
easy to operate
Call up the method – press start
Standard user methods facilitate familiarization with the system and allow the Titrando to be used
immediately. By using our methods you can profit from our many years of experience in the titra-
tion field. All titration methods developed on Metrohm Titrinos can be converted into Titrando
methods automatically using a PC. As storage media for your methods, sample data and results
there are the Titrando itself, a memory card or the PC with its numerous possibilities.

Intelligence creates transparency
Operating the Titrando System is simple and intuitive. In addition, the following tools make life
easier for the Titrando user:

• The «Quick Access» function (direct parameters) allows direct access to the parameters required
  for the given application. This means that it is no longer necessary for you to click your way
  through different operating levels!
• The «Help» fixed key shows a content-related help text in the display. The «Follow me» help
  function is available when working with a PC. Continuous explanations about the current
  surroundings are given in a separate window and further possible procedures are indicated.
• The standard user methods can be modified to suit your requirements. Method templates and
  calculation formula templates are available for developing your own methods. Methods can be
  stored under meaningful method names (32 characters) and structured directories can be used;
  this makes sorting, identification and searching much easier.
• Whereas in the expert dialog all settings are available, the routine dialog can be freely configu-
  red, i.e. it can be custom-made to meet the requirements of the particular user. This means that
  users can load their «profiles» from the personal Keycard and see only those operating elements
  that they actually need.




                                                                                                       5
Brainy dosing elements with
    certification
    Metrohm’s Exchange Unit sets new standards with regard to reliability. Each Exchange Unit is
    equipped with a data chip. The Titrando automatically reads from it all the data that it needs to
    carry out the titration properly, i.e. type of reagent, titer, last titer determination, shelf-life data and
    much more. In addition, the Titrando compares the data it has obtained with the selected method
    and carries out a plausibility test. If the result is negative then a clear error message appears.

    In addition, each Exchange Unit is provided with serial and cylinder numbers and is supplied with
    a certificate of its own. The Titrando checks the preset intervals for the titer determination of the
    titrant. This ensures that work is always carried out with the exact titer.




6
The iTrodes –
electrodes with brains
The electrode used for the titration is really the most important component of any titration system.
The iTrodes represent our new intelligent electrode generation and guarantee complete traceability
of the analytical result to each component participating in the analysis.

Digital identification – no more mix-ups
The built-in memory chip allows the storage of such important sensor data as article and serial
numbers, calibration data, calibration history, working life and calibration validity period. All the
sensor data is read in automatically when the iTrode is connected to the 888 Titrando. Mix-ups
or editing errors are therefore eliminated. The electrode is identified automatically. If the type of
electrode is not the same as that defined in the method then the user is informed. This means
that it is not possible to use an incorrect electrode.

Storage of calibration data – outliers have no chance
Monitoring functions allow the exclusion of electrodes whose calibration data lies outside the
limits or whose calibration period has already expired. If the sensor is used with different instru-
ments or if you wish to prevent inexperienced users from having to calibrate the electrode on their
own instruments then the electrode can be calibrated on a different instrument under defined
conditions. The calibration data stored in the chip makes the electrode transferable; it does not
need to be recalibrated each time that it is used with a different instrument.

Compatible with all existing sensors
Despite its new digital measuring interface and intelligent sensors, the
888 Titrando with combined analog and digital measuring input also
supports conventional sensors. This means that you can continue to
use all your sensors.




                                                                                                        7
Karl Fischer titration
    with the 890 Titrando
                       The sophisticated control algorithm and the increased volume resolution of
                       the 890 Titrando’s intelligent Exchange Unit guarantee highly precise results
                       combined with easy and intuitive user guidance.

                       The KF icons show you at a glance whether the instrument is still busy condi-
                       tioning or whether you can start the water determination.



                              The iodine drop indicates the KF reagent addition during conditioning.



                              Conditioning is finished and the sample can be added.

                       The electrode test and the newly created parameter «safety stop» prevent cell
                       run-over during conditioning. If, for example, the electrode is not connected
                       correctly or the titration cell is very humid, conditioning is stopped after a given
    time or a given volume of KF reagent added. This new feature increases work safety in your labo-
    ratory.

    The 803 Ti Stand for KF titration
    Use the 803 Ti Stand for stirring and manually exchanging the spent titration vessel contents.
    With the integrated membrane pump, solvent can be aspirated or added without the cell having
    to be opened. This translates into vastly reduced conditioning times.




8
The Titrando in the modern
laboratory
Touch Control = user comfort
The Touch Control is a decidedly ergonomic and modern operating element. You can hold it in your
hand, put it on the laboratory bench or use a holder (option) to attach it to a rod or hook it onto the
wall. These last two possibilities save space and also protect the Touch Control from chemicals. Up to
three Titrandos can be controlled by a single Touch Control.

Titrando and PC – a harmonic duo
No matter whether you operate the Titrando with the Touch Control and your fingers or via a PC and
a mouse – both appearance and operation are practically identical. Methods and determinations are
100% compatible. The titration software tiamoTM – titration and more – opens up many other possi-
bilities such as database functionality, parallel titration with several instruments and much more.

Data management is knowledge management
The data that your Titrando system provides you with can be printed out and stored in a conventional
manner. However, all advanced data management functions are available, for example storage on a
PCMCIA card (CompactFlash) that is simply inserted in the Touch Control, in the PCMCIA port of the
PC or an appropriate card reader. If you work with PC Control or tiamoTM, you can use all the storage
options offered by the PC world, and on request the Titrando can produce a machine-readable
PC/LIMS report.

Lab Link
Lab Link opens up internal networks to the Titrando and makes it Internet-compatible, with all that
this implies. In this way, the Titrando can be integrated into LIMS, methods and determinations can
be downloaded from the internal networks or saved on them, printers can be used for printing out
analysis reports. The Titrando is even accessible from the office by remote control.

Compatibility and traceability
The Titrando System is entirely oriented towards quality management in the laboratory and offers the
following possibilities:
• Auto-diagnostic test after switching on.
• Monitoring of validation and service intervals.
• Monitoring of the calibration data of sensors.
• Monitoring of titers and results.
• All changes to the methods are documented.
• Strict control of rights of access using login and password, complying with FDA Regulation 21 CFR
  Part 11 regarding «electronic signature» and «electronic record».




                                                                                                          9
Integrated automation

     Increasing sample numbers, time-consuming sample preparation steps and unattended overnight
     operation are good reasons for using sample changers. The 888 and 890 Titrandos have the neces-
     sary intelligence to control sample changers. Whether you require small or large sample capacity,
     one or two working stations, sample metering, sample preparation, liquid handling, rinsing and
     calibration of the electrodes – the 814 USB Sample Processor and 815 Robotic USB Sample Processor
     XL offer a high degree of automation at low investment costs. It’s amazing: You simply connect
     the sample changer to the Titrando’s USB port and the world of automation opens up to you. Our
     sample changer brochure supplies detailed information on the automation possibilities.




10
Ordering information, options




2.888.0110             888 Titrando with Touch Control
      1 x 2.888.0010   888 Titrando
      1 x 2.840.0100   840 Touch Control
      1 x 2.801.0040   801 Stirrer (magnetic)
      1 x 6.3026.220   Intelligent Exchange Unit (20 mL)
      1 x 6.0262.100   Ecotrode plus
      1 x 6.2104.020   Electrode cable

2.888.0210             888 Titrando with tiamoTM light
      1 x 2.888.0010   888 Titrando
      1 x 6.6056.131   tiamoTM 1.3 light
      1 x 6.2151.000   Cable USB A – Mini DIN 8 pins
      1 x 2.801.0040   801 Stirrer (magnetic)
      1 x 6.3026.220   Intelligent Exchange Unit (20 mL)
      1 x 6.0262.100   Ecotrode plus
      1 x 6.2104.020   Electrode cable

2.890.0110             890 Titrando with Touch Control
      1 x 2.890.0010   890 Titrando
      1 x 2.840.0100   840 Touch Control
      1 x 2.803.0010   803 Ti Stand
      1 x 6.3026.210   Intelligent Exchange Unit (10 mL)

2.890.0210             890 Titrando with tiamoTM light
      1 x 2.890.0010   890 Titrando
      1 x 6.6056.131   tiamoTM 1.3 light
      1 x 6.2151.000   Cable USB A – Mini DIN 8 pins
      1 x 2.803.0010   803 Ti Stand
      1 x 6.3026.210   Intelligent Exchange Unit (10 mL)

Optional accessories
     2.805.0010        805 Dosimat
     6.3026.120        Intelligent Exchange Unit 1 mL for 805 Dosimat
     6.3026.150        Intelligent Exchange Unit 5 mL for 805 Dosimat
     6.3026.210        Intelligent Exchange Unit 10 mL for 805 Dosimat
     6.3026.220        Intelligent Exchange Unit 20 mL for 805 Dosimat
     6.3026.250        Intelligent Exchange Unit 50 mL for 805 Dosimat
     2.800.0010        800 Dosino
     6.3032.120        Intelligent Dosing Unit 2 mL for 800 Dosino
     6.3032.150        Intelligent Dosing Unit 5 mL for 800 Dosino
     6.3032.210        Intelligent Dosing Unit 10 mL for 800 Dosino
     6.3032.220        Intelligent Dosing Unit 20 mL for 800 Dosino
     6.3032.250        Intelligent Dosing Unit 50 mL for 800 Dosino
     2.804.0040        804 Ti Stand with support
     2.802.0040        802 Stirrer (rod) for 804
     2.847.0010        USB Lab Link
     6.2148.020        RS-232/USB Box




                                                                         11
Metrohm AG
CH-9101 Herisau/Switzerland
Phone +41 71 353 85 85
Fax   +41 71 353 89 01
www.metrohm.com
info@metrohm.com
www.titrando.com



                              Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG., Herisau
                              8.888.5001EN – 2008-09
                              Subject to change

Weitere ähnliche Inhalte

Was ist angesagt?

Qualification of membrane filtration apparatus
Qualification of membrane filtration apparatusQualification of membrane filtration apparatus
Qualification of membrane filtration apparatusPRAVADA
 
Rapid mixer granulator
Rapid mixer granulatorRapid mixer granulator
Rapid mixer granulatorRavish Yadav
 
Analytical Method Validation as per ICH vs USP
Analytical Method Validation as per ICH vs USPAnalytical Method Validation as per ICH vs USP
Analytical Method Validation as per ICH vs USPKushal Shah
 
Pharmaceutical water
Pharmaceutical waterPharmaceutical water
Pharmaceutical waterAhmed Adel
 
1 - Introduction to Computerized Systems Validation - for review.pptx
1 - Introduction to Computerized Systems Validation - for review.pptx1 - Introduction to Computerized Systems Validation - for review.pptx
1 - Introduction to Computerized Systems Validation - for review.pptxpatemalabanan
 
Qualification of Dry Heat Sterilizer or Tunnel.pptx
Qualification of Dry Heat Sterilizer or Tunnel.pptxQualification of Dry Heat Sterilizer or Tunnel.pptx
Qualification of Dry Heat Sterilizer or Tunnel.pptxDhruvi50
 
Validation of pharaceutical water system and pure steam
Validation of pharaceutical water system and pure steamValidation of pharaceutical water system and pure steam
Validation of pharaceutical water system and pure steamJp Prakash
 
Process analytical technology
Process analytical technologyProcess analytical technology
Process analytical technologyanjalibharat19
 
Bracketing and Matrixing Methods for Stability analysis
Bracketing and Matrixing Methods for Stability analysisBracketing and Matrixing Methods for Stability analysis
Bracketing and Matrixing Methods for Stability analysisSarath Chandra
 
Facility Qualification & Consideration of Validation Aspects
Facility Qualification & Consideration of Validation Aspects Facility Qualification & Consideration of Validation Aspects
Facility Qualification & Consideration of Validation Aspects Apoorva Bauskar
 
Presentation on data integrity in Pharmaceutical Industry
Presentation on data integrity in Pharmaceutical IndustryPresentation on data integrity in Pharmaceutical Industry
Presentation on data integrity in Pharmaceutical IndustrySathish Vemula
 
Pat process analytical technique
Pat  process analytical techniquePat  process analytical technique
Pat process analytical techniqueSalmanLatif14
 
Tap density tester
Tap density testerTap density tester
Tap density testerjaincolab
 
Ich guidelines on risk assessment and risk mangment
Ich guidelines on risk assessment and risk mangmentIch guidelines on risk assessment and risk mangment
Ich guidelines on risk assessment and risk mangmentAshvin Bhoge
 

Was ist angesagt? (20)

Cfr 21 part 11
 Cfr 21 part 11 Cfr 21 part 11
Cfr 21 part 11
 
Qualification of membrane filtration apparatus
Qualification of membrane filtration apparatusQualification of membrane filtration apparatus
Qualification of membrane filtration apparatus
 
Cleaning validation
Cleaning validationCleaning validation
Cleaning validation
 
Computerized system validation
Computerized system validationComputerized system validation
Computerized system validation
 
Rapid mixer granulator
Rapid mixer granulatorRapid mixer granulator
Rapid mixer granulator
 
Analytical Method Validation as per ICH vs USP
Analytical Method Validation as per ICH vs USPAnalytical Method Validation as per ICH vs USP
Analytical Method Validation as per ICH vs USP
 
Pharmaceutical water
Pharmaceutical waterPharmaceutical water
Pharmaceutical water
 
1 - Introduction to Computerized Systems Validation - for review.pptx
1 - Introduction to Computerized Systems Validation - for review.pptx1 - Introduction to Computerized Systems Validation - for review.pptx
1 - Introduction to Computerized Systems Validation - for review.pptx
 
Deviation QA
Deviation QADeviation QA
Deviation QA
 
Qualification of Dry Heat Sterilizer or Tunnel.pptx
Qualification of Dry Heat Sterilizer or Tunnel.pptxQualification of Dry Heat Sterilizer or Tunnel.pptx
Qualification of Dry Heat Sterilizer or Tunnel.pptx
 
Validation of pharaceutical water system and pure steam
Validation of pharaceutical water system and pure steamValidation of pharaceutical water system and pure steam
Validation of pharaceutical water system and pure steam
 
Friability test apparatus
Friability test apparatusFriability test apparatus
Friability test apparatus
 
Process analytical technology
Process analytical technologyProcess analytical technology
Process analytical technology
 
Bracketing and Matrixing Methods for Stability analysis
Bracketing and Matrixing Methods for Stability analysisBracketing and Matrixing Methods for Stability analysis
Bracketing and Matrixing Methods for Stability analysis
 
Facility Qualification & Consideration of Validation Aspects
Facility Qualification & Consideration of Validation Aspects Facility Qualification & Consideration of Validation Aspects
Facility Qualification & Consideration of Validation Aspects
 
Qualification of gc equipment
Qualification of gc equipmentQualification of gc equipment
Qualification of gc equipment
 
Presentation on data integrity in Pharmaceutical Industry
Presentation on data integrity in Pharmaceutical IndustryPresentation on data integrity in Pharmaceutical Industry
Presentation on data integrity in Pharmaceutical Industry
 
Pat process analytical technique
Pat  process analytical techniquePat  process analytical technique
Pat process analytical technique
 
Tap density tester
Tap density testerTap density tester
Tap density tester
 
Ich guidelines on risk assessment and risk mangment
Ich guidelines on risk assessment and risk mangmentIch guidelines on risk assessment and risk mangment
Ich guidelines on risk assessment and risk mangment
 

Ähnlich wie Touch Control Potentiometric Titrator and KF Titrator Guide

Ähnlich wie Touch Control Potentiometric Titrator and KF Titrator Guide (20)

Testo 176 p1 datasheet
Testo 176 p1 datasheetTesto 176 p1 datasheet
Testo 176 p1 datasheet
 
Testo 645 datasheet 2012
Testo 645 datasheet 2012Testo 645 datasheet 2012
Testo 645 datasheet 2012
 
Testo 175 t1-t2 datasheet
Testo 175 t1-t2 datasheetTesto 175 t1-t2 datasheet
Testo 175 t1-t2 datasheet
 
Up 15 K Brochure
Up 15 K BrochureUp 15 K Brochure
Up 15 K Brochure
 
Testo 110 datasheet 2012
Testo 110 datasheet 2012Testo 110 datasheet 2012
Testo 110 datasheet 2012
 
Testo 175 h1 datasheet
Testo 175 h1 datasheetTesto 175 h1 datasheet
Testo 175 h1 datasheet
 
Auto Kerato Refracto Tonometer
Auto Kerato Refracto TonometerAuto Kerato Refracto Tonometer
Auto Kerato Refracto Tonometer
 
PhoenixTM PTM12 HTS08 Brochure
PhoenixTM PTM12 HTS08 BrochurePhoenixTM PTM12 HTS08 Brochure
PhoenixTM PTM12 HTS08 Brochure
 
Webinar: Is your cheese at the correct temperature?
Webinar: Is your cheese at the correct temperature?Webinar: Is your cheese at the correct temperature?
Webinar: Is your cheese at the correct temperature?
 
Ss rtc-156 157
Ss rtc-156 157Ss rtc-156 157
Ss rtc-156 157
 
Dau can-ohaus
Dau can-ohausDau can-ohaus
Dau can-ohaus
 
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamikaKatalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
 
iDTRONIC BLUEBOX Show
iDTRONIC BLUEBOX ShowiDTRONIC BLUEBOX Show
iDTRONIC BLUEBOX Show
 
Testo 545 datasheet 2012
Testo 545 datasheet 2012Testo 545 datasheet 2012
Testo 545 datasheet 2012
 
Testo huminator datasheet 2012
Testo huminator datasheet 2012Testo huminator datasheet 2012
Testo huminator datasheet 2012
 
Ion Meter from Metrohm
Ion Meter from MetrohmIon Meter from Metrohm
Ion Meter from Metrohm
 
pH / Ion meter from Metrohm
pH / Ion meter from MetrohmpH / Ion meter from Metrohm
pH / Ion meter from Metrohm
 
Testo 922 datasheet 2012
Testo 922 datasheet 2012Testo 922 datasheet 2012
Testo 922 datasheet 2012
 
Meet the T100 from Bio-Rad Laboratories
Meet the T100 from Bio-Rad LaboratoriesMeet the T100 from Bio-Rad Laboratories
Meet the T100 from Bio-Rad Laboratories
 
Specs.pdf
Specs.pdfSpecs.pdf
Specs.pdf
 

Mehr von Metrohm India Limited

Manual titration can be automated with ECO TITRATOR - save time and increase ...
Manual titration can be automated with ECO TITRATOR - save time and increase ...Manual titration can be automated with ECO TITRATOR - save time and increase ...
Manual titration can be automated with ECO TITRATOR - save time and increase ...Metrohm India Limited
 
Global webinar on Advanced solutions for battery material characterization
Global webinar on Advanced solutions for battery material characterizationGlobal webinar on Advanced solutions for battery material characterization
Global webinar on Advanced solutions for battery material characterizationMetrohm India Limited
 
IIT Bombay Metrohm Young Chemist Award 2019
IIT Bombay Metrohm Young Chemist Award 2019IIT Bombay Metrohm Young Chemist Award 2019
IIT Bombay Metrohm Young Chemist Award 2019Metrohm India Limited
 
Application note on purified water for mammalian and bacterial cell culture
Application note on purified water for mammalian and bacterial cell cultureApplication note on purified water for mammalian and bacterial cell culture
Application note on purified water for mammalian and bacterial cell cultureMetrohm India Limited
 
Coulometer for low level water determination in sample matrix
Coulometer for low level water determination in sample matrixCoulometer for low level water determination in sample matrix
Coulometer for low level water determination in sample matrixMetrohm India Limited
 
Metrohm – customized analysis for surface finishing, Process control in elect...
Metrohm – customized analysis for surface finishing, Process control in elect...Metrohm – customized analysis for surface finishing, Process control in elect...
Metrohm – customized analysis for surface finishing, Process control in elect...Metrohm India Limited
 
Ion Chromatography in determining mineral acids in Etching baths
Ion Chromatography in determining mineral acids in Etching bathsIon Chromatography in determining mineral acids in Etching baths
Ion Chromatography in determining mineral acids in Etching bathsMetrohm India Limited
 
850 intelligent-ion-chromatography by Metrohm
850 intelligent-ion-chromatography by Metrohm850 intelligent-ion-chromatography by Metrohm
850 intelligent-ion-chromatography by MetrohmMetrohm India Limited
 

Mehr von Metrohm India Limited (20)

Manual titration can be automated with ECO TITRATOR - save time and increase ...
Manual titration can be automated with ECO TITRATOR - save time and increase ...Manual titration can be automated with ECO TITRATOR - save time and increase ...
Manual titration can be automated with ECO TITRATOR - save time and increase ...
 
Global webinar on Advanced solutions for battery material characterization
Global webinar on Advanced solutions for battery material characterizationGlobal webinar on Advanced solutions for battery material characterization
Global webinar on Advanced solutions for battery material characterization
 
IIT Bombay Metrohm Young Chemist Award 2019
IIT Bombay Metrohm Young Chemist Award 2019IIT Bombay Metrohm Young Chemist Award 2019
IIT Bombay Metrohm Young Chemist Award 2019
 
Application note on purified water for mammalian and bacterial cell culture
Application note on purified water for mammalian and bacterial cell cultureApplication note on purified water for mammalian and bacterial cell culture
Application note on purified water for mammalian and bacterial cell culture
 
Brochure power plantanalysis
Brochure power plantanalysisBrochure power plantanalysis
Brochure power plantanalysis
 
875 kf gas analyzer
875 kf gas analyzer875 kf gas analyzer
875 kf gas analyzer
 
Petrochemical Analysis
Petrochemical AnalysisPetrochemical Analysis
Petrochemical Analysis
 
Environmental analysis
Environmental analysisEnvironmental analysis
Environmental analysis
 
Ti touch brochure
Ti touch brochureTi touch brochure
Ti touch brochure
 
Coulometer for low level water determination in sample matrix
Coulometer for low level water determination in sample matrixCoulometer for low level water determination in sample matrix
Coulometer for low level water determination in sample matrix
 
Metrohm – customized analysis for surface finishing, Process control in elect...
Metrohm – customized analysis for surface finishing, Process control in elect...Metrohm – customized analysis for surface finishing, Process control in elect...
Metrohm – customized analysis for surface finishing, Process control in elect...
 
Surface finishing
Surface finishingSurface finishing
Surface finishing
 
Ion Chromatography in determining mineral acids in Etching baths
Ion Chromatography in determining mineral acids in Etching bathsIon Chromatography in determining mineral acids in Etching baths
Ion Chromatography in determining mineral acids in Etching baths
 
Battery research
Battery research Battery research
Battery research
 
Biofuels analysis from Metrohm
Biofuels analysis from MetrohmBiofuels analysis from Metrohm
Biofuels analysis from Metrohm
 
Accessories by Metrohm India
Accessories by Metrohm IndiaAccessories by Metrohm India
Accessories by Metrohm India
 
797 VA For Trace analysis
797 VA For Trace analysis797 VA For Trace analysis
797 VA For Trace analysis
 
850 intelligent-ion-chromatography by Metrohm
850 intelligent-ion-chromatography by Metrohm850 intelligent-ion-chromatography by Metrohm
850 intelligent-ion-chromatography by Metrohm
 
Rancimat by Metrohm
Rancimat by MetrohmRancimat by Metrohm
Rancimat by Metrohm
 
pH kit by Metrohm
pH kit by MetrohmpH kit by Metrohm
pH kit by Metrohm
 

Kürzlich hochgeladen

Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17
Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17
Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17Celine George
 
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSGRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSJoshuaGantuangco2
 
Karra SKD Conference Presentation Revised.pptx
Karra SKD Conference Presentation Revised.pptxKarra SKD Conference Presentation Revised.pptx
Karra SKD Conference Presentation Revised.pptxAshokKarra1
 
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...Nguyen Thanh Tu Collection
 
Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Celine George
 
Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Jisc
 
Choosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for ParentsChoosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for Parentsnavabharathschool99
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxiammrhaywood
 
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)lakshayb543
 
Science 7 Quarter 4 Module 2: Natural Resources.pptx
Science 7 Quarter 4 Module 2: Natural Resources.pptxScience 7 Quarter 4 Module 2: Natural Resources.pptx
Science 7 Quarter 4 Module 2: Natural Resources.pptxMaryGraceBautista27
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Mark Reed
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersSabitha Banu
 
Q4 English4 Week3 PPT Melcnmg-based.pptx
Q4 English4 Week3 PPT Melcnmg-based.pptxQ4 English4 Week3 PPT Melcnmg-based.pptx
Q4 English4 Week3 PPT Melcnmg-based.pptxnelietumpap1
 
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfphamnguyenenglishnb
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designMIPLM
 
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxGrade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxChelloAnnAsuncion2
 
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITY
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITYISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITY
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITYKayeClaireEstoconing
 

Kürzlich hochgeladen (20)

Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17
Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17
Incoming and Outgoing Shipments in 3 STEPS Using Odoo 17
 
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSGRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
 
Karra SKD Conference Presentation Revised.pptx
Karra SKD Conference Presentation Revised.pptxKarra SKD Conference Presentation Revised.pptx
Karra SKD Conference Presentation Revised.pptx
 
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
 
Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17
 
Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...
 
Choosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for ParentsChoosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for Parents
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
 
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)
Visit to a blind student's school🧑‍🦯🧑‍🦯(community medicine)
 
OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...
 
Science 7 Quarter 4 Module 2: Natural Resources.pptx
Science 7 Quarter 4 Module 2: Natural Resources.pptxScience 7 Quarter 4 Module 2: Natural Resources.pptx
Science 7 Quarter 4 Module 2: Natural Resources.pptx
 
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptxLEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)
 
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptxFINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginners
 
Q4 English4 Week3 PPT Melcnmg-based.pptx
Q4 English4 Week3 PPT Melcnmg-based.pptxQ4 English4 Week3 PPT Melcnmg-based.pptx
Q4 English4 Week3 PPT Melcnmg-based.pptx
 
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-design
 
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxGrade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
 
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITY
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITYISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITY
ISYU TUNGKOL SA SEKSWLADIDA (ISSUE ABOUT SEXUALITY
 

Touch Control Potentiometric Titrator and KF Titrator Guide

  • 2. 888 Titrando – potentiometric titrator 890 Titrando – Karl Fischer titrator 2
  • 3. • Touch Control with large color screen • Titration software PC Control or tiamoTM for operation via PC • Intuitive operation • Intelligent Exchange Units • Intelligent electrodes «iTrodes» for the 888 Titrando • Potentiometric titration with the 888 Titrando • Karl Fischer titration with the 890 Titrando • Sample Processor control • Lab Link for Intranet and Internet • Online help • Complies with FDA regulation 21 CFR Part 11 • USB interfaces for sample changer, printer, PC keyboard, barcode reader... 3
  • 4. Overview of the 888 Titrando and 890 Titrando 888 Titrando 890 Titrando Intelligent dosing elements for titration 1 integrated Dosimat 1 integrated Dosimat for Exchange Unit for Exchange Unit Additional dosing elements (dispensing only) 3 x 805 Dosimat 3 x 805 Dosimat with Exchange Unit with Exchange Unit 3 x 800 Dosino 3 x 800 Dosino with Dosing Unit with Dosing Unit Intelligent Exchange Unit with integral data Yes chip Increments per cylinder volume (Exchange Unit) 20’000 Measuring interface for pH, U/mV, T/°C 1 – Intelligent electrodes «iTrodes» 1 – Measuring input for polarizable electrodes 1 Operation, dialog Touch Control, PC Control or tiamoTM Stirrers, titration stand 801 Stirrer (magnetic) or 802 Stirrer (rod) with 804 Ti Stand or 803 Ti Stand (KF) Connections for stirrers and intelligent dosing 4 MSB connections elements (Metrohm Serial Bus, Daisy Chain) Connection for sample changer 1 sample changer via USB Connections for balances, printer, PC, Via 2 USB Slave Ports, RS-232/USB Box PC keyboard, barcode reader and/or Lab Link (option) Temperature sensor Pt 1000 or NTC – Differential amplifier Option – Real-time curve display on Touch Control or Yes PC screen DET Dynamic equivalence-point titration Yes – MET Monotonic equivalence-point titration Yes – SET Titration to preset endpoints with Yes – automatic conditioning KFT Volumetric Karl Fischer titration with – Yes automatic conditioning MEAS Measuring mode for pH, U/mV, T/°C, Yes – Ipol, Upol CAL Calibration with automatic buffer Yes – recognition Additional titration curve evaluation for: fixed Yes – endpoints, pK values (HNP) Comprehensive GLP/GMP functions; complies Yes with FDA 21 CFR Part 11 4
  • 5. Uniquely intelligent – easy to operate Call up the method – press start Standard user methods facilitate familiarization with the system and allow the Titrando to be used immediately. By using our methods you can profit from our many years of experience in the titra- tion field. All titration methods developed on Metrohm Titrinos can be converted into Titrando methods automatically using a PC. As storage media for your methods, sample data and results there are the Titrando itself, a memory card or the PC with its numerous possibilities. Intelligence creates transparency Operating the Titrando System is simple and intuitive. In addition, the following tools make life easier for the Titrando user: • The «Quick Access» function (direct parameters) allows direct access to the parameters required for the given application. This means that it is no longer necessary for you to click your way through different operating levels! • The «Help» fixed key shows a content-related help text in the display. The «Follow me» help function is available when working with a PC. Continuous explanations about the current surroundings are given in a separate window and further possible procedures are indicated. • The standard user methods can be modified to suit your requirements. Method templates and calculation formula templates are available for developing your own methods. Methods can be stored under meaningful method names (32 characters) and structured directories can be used; this makes sorting, identification and searching much easier. • Whereas in the expert dialog all settings are available, the routine dialog can be freely configu- red, i.e. it can be custom-made to meet the requirements of the particular user. This means that users can load their «profiles» from the personal Keycard and see only those operating elements that they actually need. 5
  • 6. Brainy dosing elements with certification Metrohm’s Exchange Unit sets new standards with regard to reliability. Each Exchange Unit is equipped with a data chip. The Titrando automatically reads from it all the data that it needs to carry out the titration properly, i.e. type of reagent, titer, last titer determination, shelf-life data and much more. In addition, the Titrando compares the data it has obtained with the selected method and carries out a plausibility test. If the result is negative then a clear error message appears. In addition, each Exchange Unit is provided with serial and cylinder numbers and is supplied with a certificate of its own. The Titrando checks the preset intervals for the titer determination of the titrant. This ensures that work is always carried out with the exact titer. 6
  • 7. The iTrodes – electrodes with brains The electrode used for the titration is really the most important component of any titration system. The iTrodes represent our new intelligent electrode generation and guarantee complete traceability of the analytical result to each component participating in the analysis. Digital identification – no more mix-ups The built-in memory chip allows the storage of such important sensor data as article and serial numbers, calibration data, calibration history, working life and calibration validity period. All the sensor data is read in automatically when the iTrode is connected to the 888 Titrando. Mix-ups or editing errors are therefore eliminated. The electrode is identified automatically. If the type of electrode is not the same as that defined in the method then the user is informed. This means that it is not possible to use an incorrect electrode. Storage of calibration data – outliers have no chance Monitoring functions allow the exclusion of electrodes whose calibration data lies outside the limits or whose calibration period has already expired. If the sensor is used with different instru- ments or if you wish to prevent inexperienced users from having to calibrate the electrode on their own instruments then the electrode can be calibrated on a different instrument under defined conditions. The calibration data stored in the chip makes the electrode transferable; it does not need to be recalibrated each time that it is used with a different instrument. Compatible with all existing sensors Despite its new digital measuring interface and intelligent sensors, the 888 Titrando with combined analog and digital measuring input also supports conventional sensors. This means that you can continue to use all your sensors. 7
  • 8. Karl Fischer titration with the 890 Titrando The sophisticated control algorithm and the increased volume resolution of the 890 Titrando’s intelligent Exchange Unit guarantee highly precise results combined with easy and intuitive user guidance. The KF icons show you at a glance whether the instrument is still busy condi- tioning or whether you can start the water determination. The iodine drop indicates the KF reagent addition during conditioning. Conditioning is finished and the sample can be added. The electrode test and the newly created parameter «safety stop» prevent cell run-over during conditioning. If, for example, the electrode is not connected correctly or the titration cell is very humid, conditioning is stopped after a given time or a given volume of KF reagent added. This new feature increases work safety in your labo- ratory. The 803 Ti Stand for KF titration Use the 803 Ti Stand for stirring and manually exchanging the spent titration vessel contents. With the integrated membrane pump, solvent can be aspirated or added without the cell having to be opened. This translates into vastly reduced conditioning times. 8
  • 9. The Titrando in the modern laboratory Touch Control = user comfort The Touch Control is a decidedly ergonomic and modern operating element. You can hold it in your hand, put it on the laboratory bench or use a holder (option) to attach it to a rod or hook it onto the wall. These last two possibilities save space and also protect the Touch Control from chemicals. Up to three Titrandos can be controlled by a single Touch Control. Titrando and PC – a harmonic duo No matter whether you operate the Titrando with the Touch Control and your fingers or via a PC and a mouse – both appearance and operation are practically identical. Methods and determinations are 100% compatible. The titration software tiamoTM – titration and more – opens up many other possi- bilities such as database functionality, parallel titration with several instruments and much more. Data management is knowledge management The data that your Titrando system provides you with can be printed out and stored in a conventional manner. However, all advanced data management functions are available, for example storage on a PCMCIA card (CompactFlash) that is simply inserted in the Touch Control, in the PCMCIA port of the PC or an appropriate card reader. If you work with PC Control or tiamoTM, you can use all the storage options offered by the PC world, and on request the Titrando can produce a machine-readable PC/LIMS report. Lab Link Lab Link opens up internal networks to the Titrando and makes it Internet-compatible, with all that this implies. In this way, the Titrando can be integrated into LIMS, methods and determinations can be downloaded from the internal networks or saved on them, printers can be used for printing out analysis reports. The Titrando is even accessible from the office by remote control. Compatibility and traceability The Titrando System is entirely oriented towards quality management in the laboratory and offers the following possibilities: • Auto-diagnostic test after switching on. • Monitoring of validation and service intervals. • Monitoring of the calibration data of sensors. • Monitoring of titers and results. • All changes to the methods are documented. • Strict control of rights of access using login and password, complying with FDA Regulation 21 CFR Part 11 regarding «electronic signature» and «electronic record». 9
  • 10. Integrated automation Increasing sample numbers, time-consuming sample preparation steps and unattended overnight operation are good reasons for using sample changers. The 888 and 890 Titrandos have the neces- sary intelligence to control sample changers. Whether you require small or large sample capacity, one or two working stations, sample metering, sample preparation, liquid handling, rinsing and calibration of the electrodes – the 814 USB Sample Processor and 815 Robotic USB Sample Processor XL offer a high degree of automation at low investment costs. It’s amazing: You simply connect the sample changer to the Titrando’s USB port and the world of automation opens up to you. Our sample changer brochure supplies detailed information on the automation possibilities. 10
  • 11. Ordering information, options 2.888.0110 888 Titrando with Touch Control 1 x 2.888.0010 888 Titrando 1 x 2.840.0100 840 Touch Control 1 x 2.801.0040 801 Stirrer (magnetic) 1 x 6.3026.220 Intelligent Exchange Unit (20 mL) 1 x 6.0262.100 Ecotrode plus 1 x 6.2104.020 Electrode cable 2.888.0210 888 Titrando with tiamoTM light 1 x 2.888.0010 888 Titrando 1 x 6.6056.131 tiamoTM 1.3 light 1 x 6.2151.000 Cable USB A – Mini DIN 8 pins 1 x 2.801.0040 801 Stirrer (magnetic) 1 x 6.3026.220 Intelligent Exchange Unit (20 mL) 1 x 6.0262.100 Ecotrode plus 1 x 6.2104.020 Electrode cable 2.890.0110 890 Titrando with Touch Control 1 x 2.890.0010 890 Titrando 1 x 2.840.0100 840 Touch Control 1 x 2.803.0010 803 Ti Stand 1 x 6.3026.210 Intelligent Exchange Unit (10 mL) 2.890.0210 890 Titrando with tiamoTM light 1 x 2.890.0010 890 Titrando 1 x 6.6056.131 tiamoTM 1.3 light 1 x 6.2151.000 Cable USB A – Mini DIN 8 pins 1 x 2.803.0010 803 Ti Stand 1 x 6.3026.210 Intelligent Exchange Unit (10 mL) Optional accessories 2.805.0010 805 Dosimat 6.3026.120 Intelligent Exchange Unit 1 mL for 805 Dosimat 6.3026.150 Intelligent Exchange Unit 5 mL for 805 Dosimat 6.3026.210 Intelligent Exchange Unit 10 mL for 805 Dosimat 6.3026.220 Intelligent Exchange Unit 20 mL for 805 Dosimat 6.3026.250 Intelligent Exchange Unit 50 mL for 805 Dosimat 2.800.0010 800 Dosino 6.3032.120 Intelligent Dosing Unit 2 mL for 800 Dosino 6.3032.150 Intelligent Dosing Unit 5 mL for 800 Dosino 6.3032.210 Intelligent Dosing Unit 10 mL for 800 Dosino 6.3032.220 Intelligent Dosing Unit 20 mL for 800 Dosino 6.3032.250 Intelligent Dosing Unit 50 mL for 800 Dosino 2.804.0040 804 Ti Stand with support 2.802.0040 802 Stirrer (rod) for 804 2.847.0010 USB Lab Link 6.2148.020 RS-232/USB Box 11
  • 12. Metrohm AG CH-9101 Herisau/Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 www.metrohm.com info@metrohm.com www.titrando.com Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG., Herisau 8.888.5001EN – 2008-09 Subject to change