How to Configure SNMP Community Strings
Document ID: 7282

Contents
Introduction
Prerequisites
    Requirements
    Components Used
    Conventions
How To Configure SNMP Community Strings on a Router and a Cisco IOS Software−based XL
Catalyst Switch
    Enable SNMP Community Strings
    Verify SNMP Community Strings
    Modify SNMP Community Strings
    Disable/Remove SNMP Community Strings
How To Configure SNMP Community Strings on an RSM
    Enable SNMP Community Strings
    Verify SNMP Community Strings
    Modify SNMP Community Strings
    Disable/Remove SNMP Community Strings
How To Configure SNMP Community Strings on a Multilayer Switch Feature Card (MSFC)
    Enable SNMP Community Strings
    Verify SNMP Community Strings
    Modify SNMP Community Strings
    Disable/Remove SNMP Community Strings
How To Configure SNMP Community Strings on a Catalyst Switch
    Enable SNMP Community Strings
    Verify SNMP Community Strings
    Modify SNMP Community Strings
    Disable/Remove SNMP Community Strings
Related Information
Introduction
This document explains how to configure Simple Network Management Protocol (SNMP) community strings
on Cisco routers, Route Switch Modules (RSMs), and Catalyst switches. In the context of this document,
configure is defined as verify, enable, modify, and disable SNMP community strings.

Prerequisites
Requirements
There are no specific requirements for this document.

Components Used
This document is not restricted to specific software and hardware versions.

The information in this document was created from the devices in a specific lab environment. All of the
devices used in this document started with a cleared (default) configuration. If your network is live, make sure
that you understand the potential impact of any command.

Conventions
Refer to the Cisco Technical Tips Conventions for more information on document conventions.

How To Configure SNMP Community Strings on a Router
and a Cisco IOS Software−based XL Catalyst Switch
Enable SNMP Community Strings
This procedure is the same for both routers and Cisco IOS software−based XL Catalyst Switches.

     1. Telnet to the router:

                prompt#telnet 172.16.99.20
     2. Enter the enable password at the prompt in order to enter the enable mode:

                Router>enable
                Password:
                Router#
     3. Display the running configuration and look for the SNMP information:

                Router#show running−config
                Building configuration...
                ....
                ....

        Note: If no SNMP information is present, continue with these steps. If any SNMP commands are
        listed, you can modify or disable them.
     4. Go into the configuration mode:

                Router#configure terminal
                Enter configuration commands, one per line.           End
                with CNTL/Z.
                Router(config)#
     5. Use this command in order to enable the Read−only (RO) community string:

                Router(config)#snmp−server community public RO

        where "public" is the Read−only community string.
     6. Use this command in order to enable the Read−write (RW) community string:

       Router(config)#snmp−server community private RW

        where "private" is the Read−write community string.
     7. Exit out of the configuration mode and return to the main prompt:

                Router(config)#exit
                Router#
     8. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings:

                Router#write memory
                Building configuration...
                [OK]
                Router#
Verify SNMP Community Strings
Here is how to verify SNMP community strings.

     1. Verify that there is TCP/IP connectivity between the Network Management Server (NMS) server and
        the router:

                C:>ping 172.16.99.20

                Pinging 172.16.99.20 with 32 bytes of data:
                Reply from 172.16.99.20: bytes=32 time<10ms TTL=247
                Reply from 172.16.99.20: bytes=32 time=10ms TTL=247
                Reply from 172.16.99.20: bytes=32 time<10ms TTL=247
                Reply from 172.16.99.20: bytes=32 time<10ms TTL=247
                Ping statistics for 172.16.99.20:
                   Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
                Approximate round trip times in milli−seconds:
                   Minimum = 0ms, Maximum = 10ms, Average = 2ms
     2. Telnet to the router:

                prompt# telnet 172.16.99.20
     3. Enter the enable password at the prompt in order to enter the enable mode:

                Router>enable
                Password:
                Router#
     4. Display the running configuration and look for the SNMP information:

                Router#show running−config
                ....
                ....
                snmp−server community public RO
                snmp−server community private RW
                ....
                ....

       In this sample output, "public" is the read−only community string and "private" is the read−write
       community string.

       Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router.

       Alternatively, execute the show snmp command in the enable mode. If you see this message, it also
       indicates that SNMP is not enabled on the router:

                Router#show snmp
                %SNMP agent not enabled
                Router#
     5. Exit out of the enable mode and return to the main prompt:

                Router#disable
                Router>


Modify SNMP Community Strings
Complete these steps in order to modify SNMP community strings.

     1. Telnet to the router:

                prompt# telnet 172.16.99.20
2. Enter the enable password at the prompt in order to enter the enable mode:

                Router>enable
                Password:
                Router#
     3. Display the running configuration and look for the SNMP information:

                Router#show running−config

                Building configuration...
                ...
                ...
                snmp−server community public RO
                snmp−server community private RW
                ....
                ....
     4. Go into the configuration mode:

                Router#configure terminal
                Enter configuration commands, one per line.           End with CNTL/Z.
                Router(config)#

             ♦ In order to modify the current Read−only (RO) community string:

                      a. Delete the current Read−only (RO) community string with this command:

                                ⋅ Router(config)#no snmp−server community public RO (where "public" is
                                  the Read−only community string)
                      b. Enter the new Read−only (RO) community string with this command:

                              ⋅ Router(config)#snmp−server community XXXX RO (where "XXXX" is
                                the Read−only community string)
             ♦ In order to modify the current Read−write (RW) community string:

                      a. Delete the current Read−write (RW) community string with this command:

                                ⋅ Router(config)#no snmp−server community private RW (where "private"
                                  is the Read−write community string)
                      b. Enter the new Read−write (RW) community string with this command:

                                ⋅ Router(config)#snmp−server community YYYY RW (where "YYYY" is
                                  the Read−write community string)
     5. Exit out of the configuration mode and return to the main prompt:

                Router(config)#exit
                Router#
     6. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings:

                Router#write memory
                Building configuration...
                [OK]
                Router#


Disable/Remove SNMP Community Strings
Complete these steps in order to disable or remove SMMP community strings.

     1. Telnet to the router:
prompt# telnet 172.16.99.20
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Router>enable
               Password:
               Router#
     3. Display the running configuration and look for the SNMP information:

               Router#show running−config

               Building configuration...
               ...
               ...
               snmp−server community public RO
               snmp−server community private RW
               ....
               ....
     4. Go into the configuration mode:

               Router#configure terminal
               Enter configuration commands, one per line.             End with CNTL/Z.
               Router(config)#
     5. In order to disable/remove the current Read−only (RO) community string, use this command:

               Router(config)#no snmp−server community public RO

        where "public" is the Read−only community string
     6. In order to disable/remove the current Read−write (RW) community string, use this command:

               Router(config)#no snmp−server community private RW

        where "private" is the Read−write community string
     7. Exit out of the configuration mode and return to the main prompt:

               Router(config)#exit
               Router#
     8. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings:

               Router#write memory
               Building configuration...
               [OK]
               Router#


How To Configure SNMP Community Strings on an RSM
Enable SNMP Community Strings
RSMs run the same Cisco IOS software code as the routers do. Consequently, you can complete the same
procedure in order to enable SNMP on an RSM as described for the routers.

Verify SNMP Community Strings
Complete this procedure to verify SNMP communtiy strings on an RSM.

     1. Telnet to the Catalyst Switch (in our example, we use the Catalyst 5500):

               prompt# telnet 172.16.99.55
     2. Enter the enable password at the prompt in order to enter the enable mode:
Cat5500>enable
          Password:
          Cat5500> (enable)
3. Execute the show module command in order to display the system modules and locate the RSM
   module. Here is an example:

          Cat5500> (enable) show module

          Mod Slot Ports Module−Type Model Sub Status
          −−− −−−− −−−−− −−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−− −−− −−−−−−
          1 1 0 Supervisor III WS−X5530 yes ok
          2 2 Gigabit Ethernet Ext WS−X5410
          3 3 9 Gigabit Ethernet WS−X5410 no ok
          4 4 24 10BaseT Ethernet WS−X5010 no ok
          5 5 1 Route Switch WS−X5302 no ok
          6 6 1 Network Analysis/RMON WS−X5380 no ok
          7 7 12 10/100BaseTX Ethernet WS−X5213A no ok
          9 9 16 Token Ring WS−X5030 no ok
          10 10 12 10BaseFL Ethernet WS−X5011 no ok
          11 11 24 10/100BaseTX Ethernet WS−X5225R no ok
          13 13 ASP/SRP no

          ...
          ...
          −−<snip>−−
4. After you identify the Mod number, start a "session" to the RSM module. Here is an example:

          Cat5500> (enable) session 5
          Trying Router−5...
          Connected to Router−5.
          Escape character is '^]'.

          RSM>
5. Enter the enable password at the prompt in order to enter the enable mode:

          RSM>enable
          Password:
          RSM#
6. Display the running configuration and look for the SNMP information:

          RSM#show running−config

          Building configuration...
          ....
          ....
          snmp−server community public RO
          snmp−server community private RW
          ....
          ....

  In this sample output, "public" is the Read−only community string and "private" is the Read−write
  community string.

  Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router.

  Alternatively, you can execute the show snmp command in the enable mode. If you see this message,
  it also indicates that SNMP is not enabled on the router.

          RSM#show snmp

          %SNMP agent not enabled
RSM#
     7. Exit out of the enable mode and return to the main prompt:

               RSM#exit
               Cat5500> (enable)


Modify SNMP Community Strings
RSM runs the same Cisco IOS software code as the routers do. You can complete the same procedure to
modify SNMP as described in the router example.

Disable/Remove SNMP Community Strings
RSM runs the same Cisco IOS software code as the routers do. You can complete the same procedure to
disable SNMP as described in the router example.

How To Configure SNMP Community Strings on a Multilayer
Switch Feature Card (MSFC)
Enable SNMP Community Strings
A multilayer switch feature card (MSFC) runs the same Cisco IOS software code as the routers do. You can
complete the same procedure to enable SNMP as described in the .

Verify SNMP Community Strings
Here is how to verify SNMP community strings on a multilayer switch feature card (MSFC).

     1. Telnet to the Catalyst Switch (the Catalyst 6509 is used in this example):

               prompt# telnet 172.16.99.66
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Cat6509>enable
               Password:
               Cat6509> (enable)
     3. Execute the show module command in order to display the system modules and locate the MSFC
        module. Here is an example:

               Cat6509 (enable) show module

               Mod Slot Ports Module−Type Model Sub Status
               −−− −−−− −−−−− −−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−−−− −−− −−−−−−
               1 1 2 1000BaseX Supervisor WS−X6K−SUP1A−2GE yes ok
               15 1 1 Multilayer Switch Feature WS−F6K−MSFC no ok
               3 3 8 1000BaseX Ethernet WS−X6408A−GBIC no ok
               4 4 48 10/100BaseTX Ethernet WS−X6348−RJ−45 yes ok
               5 5 48 10/100BaseTX Ethernet WS−X6348−RJ−45 no ok
               6 6 8 T1 WS−X6608−T1 no ok
               7 7 24 FXS WS−X6624−FXS no ok
               8 8 0 FlexWAN Module WS−X6182−2PA no ok

               ....
               ....
               −−<snip>−−
     4. After you identify the Mod number, start a "session" to the MSFC module. Here is an example:
Cat6509> (enable) session 15
                Trying Router−15...
                Connected to Router−15.
                Escape character is '^]'.

                MSFC>
     5. Enter the enable password at the prompt in order to enter the enable mode:

                MSFC>enable
                Password:
                MSFC#
     6. Display the running configuration and look for the SNMP information:

                MSFC#show running−config

                Building configuration...
                ....
                ....
                snmp−server community public RO
                snmp−server community private RW
                ....
                ....

        In this sample output, "public" is the Read−only community string and "private" is the Read−write
        community string.

        Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router.

        Alternatively, you can execute the show snmp command in the enable mode. If you see this message,
        it also indicates that SNMP is not enabled on the router:

                MSFC#show snmp

                %SNMP agent not enabled

                MSFC#
     7. Exit out of the enable mode and return to the main prompt:

                MSFC#exit
                Cat65509> (enable)


Modify SNMP Community Strings
The MSFC runs the same Cisco IOS software code as the routers do. You can complete the same procedure in
order to modify SNMP as described in the router example.

Disable/Remove SNMP Community Strings
The MSFC runs the same Cisco IOS software code as the routers do. You can complete the same procedure in
order to disable SNMP as described in the router example.

How To Configure SNMP Community Strings on a Catalyst
Switch
On Catalyst switches such as the 4000, 5000, and 6000 series that run a regular catalyst Operating System
(OS), SNMP is enabled by default with the community strings set to:
• Read−Only: Public
      • Read−Write: Private
      • Read−Write−all: Secret

With these community strings and the IP address of your switch's management interface, anyone is able to
reconfigure the device. You must change the community strings on the Catalyst switch immediately after you
set the device on the network. This is very important.

Enable SNMP Community Strings
Complete these steps in order to enable SNMP community strings on a catalyst switch.

     1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example):

               prompt# telnet 172.16.99.55
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Cat5500>enable
               Password:
               Cat5500> (enable)
     3. In order to enable Read−only (RO) community string, use this command:

               Cat5500> (enable) set snmp community read−only XXXX

        (where "XXXX" is the Read−only community string)
     4. In order to enable Read−write (RW) community string, use this command:

               Cat5500> (enable) set snmp community read−write YYYY

       where "YYYY" is the Read−write community string

        Note: The Catalyst 4000, 5000, and 6000 series switches do not have Start−up configurations. That is
        why there is no write memory command in these switches compared to the routers.
     5. Verify that the new community strings are added:

               Cat5500> (enable) show snmp

                    RMON:                    Enabled
                    Extended RMON:           Enabled
                    Extended RMON Netflow:   Enabled
                    Extended RMON Vlanmode: Disabled
                    Extended RMON Vlanagent: Disabled
                    SPAN Configuration:
                    Traps Enabled:
                    Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,
                       entity,stpx,syslog
                    Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24
                    Community−Access    Community−String
                    −−−−−−−−−−−−−−−−    −−−−−−−−−−−−−−−−
                    read−only           XXXX (XXXX is the new Read−only community string)
                    read−write          YYYY (YYYY is the new Read−write community string)
                    read−write−all      secret
                    ....
                    ....
                    −−<snip>−−
Verify SNMP Community Strings
Complete these steps in order to configure SNMP community strings on a catalyst switch.

     1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example):

               prompt# telnet 172.16.99.55
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Cat5500>enable
               Password:
               Cat5500>(enable)
     3. Execute the show snmp command in order to display the current SNMP information and look for the
        community−access information. Here is an example:

               Cat5500> (enable) show snmp

               RMON:                      Enabled
               Extended RMON:             Enabled
               Extended RMON Netflow:     Enabled
               Extended RMON Vlanmode: Disabled
               Extended RMON Vlanagent: Disabled
               SPAN Configuration:
               Traps Enabled:
               Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,
                  entity,stpx,syslog
               Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24
               Community−Access    Community−String
               −−−−−−−−−−−−−−−     −−−−−−−−−−−−−−
               read−only             XXXX         ("XXXX" is the Read−only community string)
               read−write            YYYY         ("YYYY" is the Read−write community string)
               read−write−all        secret
               ....
               ....
               −−<snip>−−


Modify SNMP Community Strings
Complete these steps in order to modify SNMP community strings on a catalyst switch.

     1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example):

               prompt# telnet 172.16.99.55
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Cat5500>enable
               Password:
               Cat5500> (enable)
     3. In order to modify the Read−only (RO) community string, use this command:

               Cat5500> (enable) set snmp community read−only public

        where "public" is the Read−only community string. The command overwrites the existing community
        string if the switch has one.
     4. In order to enable the Read−write (RW) community string, use this command:

               Cat5500> (enable) set snmp community read−write private
where "private" is the Read−write community string. The command overwrites the existing
       community string if the switch has one.

        Note: Cat OS supports only one community string for each read−only, read−write and read−write−all
        communities. You can not configure multiple community strings, unlike Cisco IOS.
     5. Execute the show snmp command in order to display the current SNMP information and look for the
        community−access information. Here is an example:

               Cat5500> (enable) show snmp

               RMON:                      Enabled
               Extended RMON:             Enabled
               Extended RMON Netflow:     Enabled
               Extended RMON Vlanmode:    Disabled
               Extended RMON Vlanagent: Disabled
               SPAN Configuration:
               Traps Enabled:
               Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,
                  entity,stpx,syslog
               Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24
               Community−Access      Community−String
               −−−−−−−−−−−−−−−−      −−−−−−−−−−−−−
               read−only             public

               !−−− public is the modified Read−only community string

               read−write                 private

               !−−− private is the modified Read−write community string

               read−write−all             secret
               ....
               ....
               −−<snip>−−


Disable/Remove SNMP Community Strings
Complete these steps in order to disable or remove SNMP community strings on a catalyst switch.

     1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example):

               prompt# telnet 172.16.99.55
     2. Enter the enable password at the prompt in order to enter the enable mode:

               Cat5500>enable
               Password:
               Cat5500>(enable)
     3. In order to delete/remove the Read−only (RO) community string, use this command:

               Cat5500> (enable) set snmp community read−only
               SNMP read−only community string cleared
     4. In order to delete/remove the Read−write (RW) community string, use this command:

               Cat5500>(enable) set snmp community read−write
               SNMP read−write community string cleared
     5. Verify that the community strings are deleted/removed. Here is an example:

               Cat5500> (enable) show snmp

               RMON:                           Enabled
               Extended RMON:                  Enabled
Extended RMON Netflow:    Enabled
                   Extended RMON Vlanmode: Disabled
                   Extended RMON Vlanagent: Disabled
                   SPAN Configuration:
                   Traps Enabled:
                   Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,
                      entity,stpx,syslog
                   Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24
                   Community−Access    Community−String
                   −−−−−−−−−−−−−−−−    −−−−−−−−−−−−−
                   read−only
                   read−write
                   ....
                   ....
                   −−<snip>−−

         As you can see, the column for "Community−String" is blank. This indicates that both the read−only
         and read−write community strings are deleted or removed.

Related Information
       • Cisco Security Advisory: Cisco IOS Software SNMP Read−Write ILMI Community String
         Vulnerability
       • Cisco Security Advisory: Cisco IOS Software Multiple SNMP Community String
       • Technical Support & Documentation − Cisco Systems


Contacts & Feedback | Help | Site Map
© 2011 − 2012 Cisco Systems, Inc. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks of
Cisco Systems, Inc.


Updated: Oct 26, 2005                                                                                      Document ID: 7282

Weitere ähnliche Inhalte

Was ist angesagt?

Ciso 4 ospf
Ciso 4 ospfCiso 4 ospf
Ciso 4 ospfmyciokas
 
Output drops due to qo s on cisco 2960 3560 3750 switches
Output drops due to qo s on cisco 2960 3560 3750 switchesOutput drops due to qo s on cisco 2960 3560 3750 switches
Output drops due to qo s on cisco 2960 3560 3750 switchescandy tang
 
Cisco hsrp configuration
Cisco hsrp configurationCisco hsrp configuration
Cisco hsrp configurationWahyu Nasution
 
How to configure inband management for huawei ma5616
How to configure inband management for huawei ma5616How to configure inband management for huawei ma5616
How to configure inband management for huawei ma5616Huanetwork
 
First Hop Redundancy Protocols in IPv6 HSRP + GLBP
First Hop Redundancy Protocols in IPv6 HSRP + GLBPFirst Hop Redundancy Protocols in IPv6 HSRP + GLBP
First Hop Redundancy Protocols in IPv6 HSRP + GLBPIT Tech
 
10 Command Line quan trọng để giao tiếp với Cisco IOs
10 Command Line quan trọng để giao tiếp với Cisco IOs10 Command Line quan trọng để giao tiếp với Cisco IOs
10 Command Line quan trọng để giao tiếp với Cisco IOsNhóc Nhóc
 
Huawei S5700 Basic Configuration Command
Huawei S5700 Basic Configuration CommandHuawei S5700 Basic Configuration Command
Huawei S5700 Basic Configuration CommandHuanetwork
 
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID Confusion
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID ConfusionHuawei ARG3 Router How To - Troubleshooting OSPF: Router ID Confusion
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID ConfusionIPMAX s.r.l.
 
Cisco IOS (internetworking operating system)
Cisco IOS (internetworking operating system)Cisco IOS (internetworking operating system)
Cisco IOS (internetworking operating system)Netwax Lab
 
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatch
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatchHuawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatch
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatchIPMAX s.r.l.
 
Saad baig practical file
Saad baig practical fileSaad baig practical file
Saad baig practical fileSaadBaig33
 
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)legasu zemene
 

Was ist angesagt? (20)

Vrrp
VrrpVrrp
Vrrp
 
Ciso 4 ospf
Ciso 4 ospfCiso 4 ospf
Ciso 4 ospf
 
Cisco CCENT Cram Notes
Cisco CCENT Cram NotesCisco CCENT Cram Notes
Cisco CCENT Cram Notes
 
ccna cheat_sheet
ccna cheat_sheetccna cheat_sheet
ccna cheat_sheet
 
Output drops due to qo s on cisco 2960 3560 3750 switches
Output drops due to qo s on cisco 2960 3560 3750 switchesOutput drops due to qo s on cisco 2960 3560 3750 switches
Output drops due to qo s on cisco 2960 3560 3750 switches
 
Cisco hsrp configuration
Cisco hsrp configurationCisco hsrp configuration
Cisco hsrp configuration
 
How to configure inband management for huawei ma5616
How to configure inband management for huawei ma5616How to configure inband management for huawei ma5616
How to configure inband management for huawei ma5616
 
Basic Configurations on Router
Basic Configurations on RouterBasic Configurations on Router
Basic Configurations on Router
 
Nat report2
Nat report2Nat report2
Nat report2
 
Layer 3 redundancy hsrp
Layer 3 redundancy   hsrpLayer 3 redundancy   hsrp
Layer 3 redundancy hsrp
 
First Hop Redundancy Protocols in IPv6 HSRP + GLBP
First Hop Redundancy Protocols in IPv6 HSRP + GLBPFirst Hop Redundancy Protocols in IPv6 HSRP + GLBP
First Hop Redundancy Protocols in IPv6 HSRP + GLBP
 
10 Command Line quan trọng để giao tiếp với Cisco IOs
10 Command Line quan trọng để giao tiếp với Cisco IOs10 Command Line quan trọng để giao tiếp với Cisco IOs
10 Command Line quan trọng để giao tiếp với Cisco IOs
 
Eigrp
EigrpEigrp
Eigrp
 
Huawei S5700 Basic Configuration Command
Huawei S5700 Basic Configuration CommandHuawei S5700 Basic Configuration Command
Huawei S5700 Basic Configuration Command
 
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID Confusion
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID ConfusionHuawei ARG3 Router How To - Troubleshooting OSPF: Router ID Confusion
Huawei ARG3 Router How To - Troubleshooting OSPF: Router ID Confusion
 
Cisco IOS (internetworking operating system)
Cisco IOS (internetworking operating system)Cisco IOS (internetworking operating system)
Cisco IOS (internetworking operating system)
 
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatch
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatchHuawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatch
Huawei ARG3 Router How To - Troubleshooting OSPF: Netmask mismatch
 
Day 10 loops+ rip+ igrp
Day 10 loops+  rip+ igrpDay 10 loops+  rip+ igrp
Day 10 loops+ rip+ igrp
 
Saad baig practical file
Saad baig practical fileSaad baig practical file
Saad baig practical file
 
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)
01 ip oc180 e1_1 zxr10 m6000_t8000 basic operation (v1.00.20)
 

Andere mochten auch

Inception与项目管理空间思想
Inception与项目管理空间思想Inception与项目管理空间思想
Inception与项目管理空间思想pilygod
 
Untitled presentation
Untitled presentationUntitled presentation
Untitled presentationJoonas Välja
 
Desastres Naturals
Desastres NaturalsDesastres Naturals
Desastres Naturalstelm23o
 

Andere mochten auch (7)

Inception与项目管理空间思想
Inception与项目管理空间思想Inception与项目管理空间思想
Inception与项目管理空间思想
 
Untitled presentation
Untitled presentationUntitled presentation
Untitled presentation
 
Bach spirit trumpete
Bach spirit trumpeteBach spirit trumpete
Bach spirit trumpete
 
Picspam update 1
Picspam update 1Picspam update 1
Picspam update 1
 
Desastres Naturals
Desastres NaturalsDesastres Naturals
Desastres Naturals
 
25 09 símbolos fundamentales de la ciencia sagrada guenon www.gftaognosticae...
25  09 símbolos fundamentales de la ciencia sagrada guenon www.gftaognosticae...25  09 símbolos fundamentales de la ciencia sagrada guenon www.gftaognosticae...
25 09 símbolos fundamentales de la ciencia sagrada guenon www.gftaognosticae...
 
Vulkaan
VulkaanVulkaan
Vulkaan
 

Ähnlich wie Snmp

Ähnlich wie Snmp (20)

lab1
lab1lab1
lab1
 
CCNA CheatSheet
CCNA CheatSheetCCNA CheatSheet
CCNA CheatSheet
 
Router Commands Overview
Router Commands OverviewRouter Commands Overview
Router Commands Overview
 
Chapter5ccna
Chapter5ccnaChapter5ccna
Chapter5ccna
 
Chapter5ccna
Chapter5ccnaChapter5ccna
Chapter5ccna
 
CCNA presentation.
CCNA presentation.CCNA presentation.
CCNA presentation.
 
CCNA at a glance
CCNA at a glanceCCNA at a glance
CCNA at a glance
 
CCNA ALL IN ONE
CCNA ALL IN ONE CCNA ALL IN ONE
CCNA ALL IN ONE
 
In depth understanding network security
In depth understanding network securityIn depth understanding network security
In depth understanding network security
 
Intro to router_config
Intro to router_configIntro to router_config
Intro to router_config
 
Manejo de redes
Manejo de redesManejo de redes
Manejo de redes
 
Chapter 10
Chapter 10Chapter 10
Chapter 10
 
Intro to router_config
Intro to router_configIntro to router_config
Intro to router_config
 
111
111111
111
 
111
111111
111
 
Routing protocol commands list
Routing protocol commands listRouting protocol commands list
Routing protocol commands list
 
Ccna command
Ccna commandCcna command
Ccna command
 
managing your network environment
managing your network environmentmanaging your network environment
managing your network environment
 
test
testtest
test
 
Cisco config
Cisco configCisco config
Cisco config
 

Kürzlich hochgeladen

Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024SynarionITSolutions
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingEdi Saputra
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CVKhem
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...apidays
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyKhushali Kathiriya
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)wesley chun
 

Kürzlich hochgeladen (20)

Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 

Snmp

  • 1. How to Configure SNMP Community Strings Document ID: 7282 Contents Introduction Prerequisites Requirements Components Used Conventions How To Configure SNMP Community Strings on a Router and a Cisco IOS Software−based XL Catalyst Switch Enable SNMP Community Strings Verify SNMP Community Strings Modify SNMP Community Strings Disable/Remove SNMP Community Strings How To Configure SNMP Community Strings on an RSM Enable SNMP Community Strings Verify SNMP Community Strings Modify SNMP Community Strings Disable/Remove SNMP Community Strings How To Configure SNMP Community Strings on a Multilayer Switch Feature Card (MSFC) Enable SNMP Community Strings Verify SNMP Community Strings Modify SNMP Community Strings Disable/Remove SNMP Community Strings How To Configure SNMP Community Strings on a Catalyst Switch Enable SNMP Community Strings Verify SNMP Community Strings Modify SNMP Community Strings Disable/Remove SNMP Community Strings Related Information Introduction This document explains how to configure Simple Network Management Protocol (SNMP) community strings on Cisco routers, Route Switch Modules (RSMs), and Catalyst switches. In the context of this document, configure is defined as verify, enable, modify, and disable SNMP community strings. Prerequisites Requirements There are no specific requirements for this document. Components Used This document is not restricted to specific software and hardware versions. The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure
  • 2. that you understand the potential impact of any command. Conventions Refer to the Cisco Technical Tips Conventions for more information on document conventions. How To Configure SNMP Community Strings on a Router and a Cisco IOS Software−based XL Catalyst Switch Enable SNMP Community Strings This procedure is the same for both routers and Cisco IOS software−based XL Catalyst Switches. 1. Telnet to the router: prompt#telnet 172.16.99.20 2. Enter the enable password at the prompt in order to enter the enable mode: Router>enable Password: Router# 3. Display the running configuration and look for the SNMP information: Router#show running−config Building configuration... .... .... Note: If no SNMP information is present, continue with these steps. If any SNMP commands are listed, you can modify or disable them. 4. Go into the configuration mode: Router#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Router(config)# 5. Use this command in order to enable the Read−only (RO) community string: Router(config)#snmp−server community public RO where "public" is the Read−only community string. 6. Use this command in order to enable the Read−write (RW) community string: Router(config)#snmp−server community private RW where "private" is the Read−write community string. 7. Exit out of the configuration mode and return to the main prompt: Router(config)#exit Router# 8. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings: Router#write memory Building configuration... [OK] Router#
  • 3. Verify SNMP Community Strings Here is how to verify SNMP community strings. 1. Verify that there is TCP/IP connectivity between the Network Management Server (NMS) server and the router: C:>ping 172.16.99.20 Pinging 172.16.99.20 with 32 bytes of data: Reply from 172.16.99.20: bytes=32 time<10ms TTL=247 Reply from 172.16.99.20: bytes=32 time=10ms TTL=247 Reply from 172.16.99.20: bytes=32 time<10ms TTL=247 Reply from 172.16.99.20: bytes=32 time<10ms TTL=247 Ping statistics for 172.16.99.20: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli−seconds: Minimum = 0ms, Maximum = 10ms, Average = 2ms 2. Telnet to the router: prompt# telnet 172.16.99.20 3. Enter the enable password at the prompt in order to enter the enable mode: Router>enable Password: Router# 4. Display the running configuration and look for the SNMP information: Router#show running−config .... .... snmp−server community public RO snmp−server community private RW .... .... In this sample output, "public" is the read−only community string and "private" is the read−write community string. Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router. Alternatively, execute the show snmp command in the enable mode. If you see this message, it also indicates that SNMP is not enabled on the router: Router#show snmp %SNMP agent not enabled Router# 5. Exit out of the enable mode and return to the main prompt: Router#disable Router> Modify SNMP Community Strings Complete these steps in order to modify SNMP community strings. 1. Telnet to the router: prompt# telnet 172.16.99.20
  • 4. 2. Enter the enable password at the prompt in order to enter the enable mode: Router>enable Password: Router# 3. Display the running configuration and look for the SNMP information: Router#show running−config Building configuration... ... ... snmp−server community public RO snmp−server community private RW .... .... 4. Go into the configuration mode: Router#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Router(config)# ♦ In order to modify the current Read−only (RO) community string: a. Delete the current Read−only (RO) community string with this command: ⋅ Router(config)#no snmp−server community public RO (where "public" is the Read−only community string) b. Enter the new Read−only (RO) community string with this command: ⋅ Router(config)#snmp−server community XXXX RO (where "XXXX" is the Read−only community string) ♦ In order to modify the current Read−write (RW) community string: a. Delete the current Read−write (RW) community string with this command: ⋅ Router(config)#no snmp−server community private RW (where "private" is the Read−write community string) b. Enter the new Read−write (RW) community string with this command: ⋅ Router(config)#snmp−server community YYYY RW (where "YYYY" is the Read−write community string) 5. Exit out of the configuration mode and return to the main prompt: Router(config)#exit Router# 6. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings: Router#write memory Building configuration... [OK] Router# Disable/Remove SNMP Community Strings Complete these steps in order to disable or remove SMMP community strings. 1. Telnet to the router:
  • 5. prompt# telnet 172.16.99.20 2. Enter the enable password at the prompt in order to enter the enable mode: Router>enable Password: Router# 3. Display the running configuration and look for the SNMP information: Router#show running−config Building configuration... ... ... snmp−server community public RO snmp−server community private RW .... .... 4. Go into the configuration mode: Router#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Router(config)# 5. In order to disable/remove the current Read−only (RO) community string, use this command: Router(config)#no snmp−server community public RO where "public" is the Read−only community string 6. In order to disable/remove the current Read−write (RW) community string, use this command: Router(config)#no snmp−server community private RW where "private" is the Read−write community string 7. Exit out of the configuration mode and return to the main prompt: Router(config)#exit Router# 8. Write the modified configuration to nonvolatile RAM (NVRAM) to save the settings: Router#write memory Building configuration... [OK] Router# How To Configure SNMP Community Strings on an RSM Enable SNMP Community Strings RSMs run the same Cisco IOS software code as the routers do. Consequently, you can complete the same procedure in order to enable SNMP on an RSM as described for the routers. Verify SNMP Community Strings Complete this procedure to verify SNMP communtiy strings on an RSM. 1. Telnet to the Catalyst Switch (in our example, we use the Catalyst 5500): prompt# telnet 172.16.99.55 2. Enter the enable password at the prompt in order to enter the enable mode:
  • 6. Cat5500>enable Password: Cat5500> (enable) 3. Execute the show module command in order to display the system modules and locate the RSM module. Here is an example: Cat5500> (enable) show module Mod Slot Ports Module−Type Model Sub Status −−− −−−− −−−−− −−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−− −−− −−−−−− 1 1 0 Supervisor III WS−X5530 yes ok 2 2 Gigabit Ethernet Ext WS−X5410 3 3 9 Gigabit Ethernet WS−X5410 no ok 4 4 24 10BaseT Ethernet WS−X5010 no ok 5 5 1 Route Switch WS−X5302 no ok 6 6 1 Network Analysis/RMON WS−X5380 no ok 7 7 12 10/100BaseTX Ethernet WS−X5213A no ok 9 9 16 Token Ring WS−X5030 no ok 10 10 12 10BaseFL Ethernet WS−X5011 no ok 11 11 24 10/100BaseTX Ethernet WS−X5225R no ok 13 13 ASP/SRP no ... ... −−<snip>−− 4. After you identify the Mod number, start a "session" to the RSM module. Here is an example: Cat5500> (enable) session 5 Trying Router−5... Connected to Router−5. Escape character is '^]'. RSM> 5. Enter the enable password at the prompt in order to enter the enable mode: RSM>enable Password: RSM# 6. Display the running configuration and look for the SNMP information: RSM#show running−config Building configuration... .... .... snmp−server community public RO snmp−server community private RW .... .... In this sample output, "public" is the Read−only community string and "private" is the Read−write community string. Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router. Alternatively, you can execute the show snmp command in the enable mode. If you see this message, it also indicates that SNMP is not enabled on the router. RSM#show snmp %SNMP agent not enabled
  • 7. RSM# 7. Exit out of the enable mode and return to the main prompt: RSM#exit Cat5500> (enable) Modify SNMP Community Strings RSM runs the same Cisco IOS software code as the routers do. You can complete the same procedure to modify SNMP as described in the router example. Disable/Remove SNMP Community Strings RSM runs the same Cisco IOS software code as the routers do. You can complete the same procedure to disable SNMP as described in the router example. How To Configure SNMP Community Strings on a Multilayer Switch Feature Card (MSFC) Enable SNMP Community Strings A multilayer switch feature card (MSFC) runs the same Cisco IOS software code as the routers do. You can complete the same procedure to enable SNMP as described in the . Verify SNMP Community Strings Here is how to verify SNMP community strings on a multilayer switch feature card (MSFC). 1. Telnet to the Catalyst Switch (the Catalyst 6509 is used in this example): prompt# telnet 172.16.99.66 2. Enter the enable password at the prompt in order to enter the enable mode: Cat6509>enable Password: Cat6509> (enable) 3. Execute the show module command in order to display the system modules and locate the MSFC module. Here is an example: Cat6509 (enable) show module Mod Slot Ports Module−Type Model Sub Status −−− −−−− −−−−− −−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−−−− −−− −−−−−− 1 1 2 1000BaseX Supervisor WS−X6K−SUP1A−2GE yes ok 15 1 1 Multilayer Switch Feature WS−F6K−MSFC no ok 3 3 8 1000BaseX Ethernet WS−X6408A−GBIC no ok 4 4 48 10/100BaseTX Ethernet WS−X6348−RJ−45 yes ok 5 5 48 10/100BaseTX Ethernet WS−X6348−RJ−45 no ok 6 6 8 T1 WS−X6608−T1 no ok 7 7 24 FXS WS−X6624−FXS no ok 8 8 0 FlexWAN Module WS−X6182−2PA no ok .... .... −−<snip>−− 4. After you identify the Mod number, start a "session" to the MSFC module. Here is an example:
  • 8. Cat6509> (enable) session 15 Trying Router−15... Connected to Router−15. Escape character is '^]'. MSFC> 5. Enter the enable password at the prompt in order to enter the enable mode: MSFC>enable Password: MSFC# 6. Display the running configuration and look for the SNMP information: MSFC#show running−config Building configuration... .... .... snmp−server community public RO snmp−server community private RW .... .... In this sample output, "public" is the Read−only community string and "private" is the Read−write community string. Note: If you do not see any "snmp−server" statements, SNMP is not enabled on the router. Alternatively, you can execute the show snmp command in the enable mode. If you see this message, it also indicates that SNMP is not enabled on the router: MSFC#show snmp %SNMP agent not enabled MSFC# 7. Exit out of the enable mode and return to the main prompt: MSFC#exit Cat65509> (enable) Modify SNMP Community Strings The MSFC runs the same Cisco IOS software code as the routers do. You can complete the same procedure in order to modify SNMP as described in the router example. Disable/Remove SNMP Community Strings The MSFC runs the same Cisco IOS software code as the routers do. You can complete the same procedure in order to disable SNMP as described in the router example. How To Configure SNMP Community Strings on a Catalyst Switch On Catalyst switches such as the 4000, 5000, and 6000 series that run a regular catalyst Operating System (OS), SNMP is enabled by default with the community strings set to:
  • 9. • Read−Only: Public • Read−Write: Private • Read−Write−all: Secret With these community strings and the IP address of your switch's management interface, anyone is able to reconfigure the device. You must change the community strings on the Catalyst switch immediately after you set the device on the network. This is very important. Enable SNMP Community Strings Complete these steps in order to enable SNMP community strings on a catalyst switch. 1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example): prompt# telnet 172.16.99.55 2. Enter the enable password at the prompt in order to enter the enable mode: Cat5500>enable Password: Cat5500> (enable) 3. In order to enable Read−only (RO) community string, use this command: Cat5500> (enable) set snmp community read−only XXXX (where "XXXX" is the Read−only community string) 4. In order to enable Read−write (RW) community string, use this command: Cat5500> (enable) set snmp community read−write YYYY where "YYYY" is the Read−write community string Note: The Catalyst 4000, 5000, and 6000 series switches do not have Start−up configurations. That is why there is no write memory command in these switches compared to the routers. 5. Verify that the new community strings are added: Cat5500> (enable) show snmp RMON: Enabled Extended RMON: Enabled Extended RMON Netflow: Enabled Extended RMON Vlanmode: Disabled Extended RMON Vlanagent: Disabled SPAN Configuration: Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config, entity,stpx,syslog Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24 Community−Access Community−String −−−−−−−−−−−−−−−− −−−−−−−−−−−−−−−− read−only XXXX (XXXX is the new Read−only community string) read−write YYYY (YYYY is the new Read−write community string) read−write−all secret .... .... −−<snip>−−
  • 10. Verify SNMP Community Strings Complete these steps in order to configure SNMP community strings on a catalyst switch. 1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example): prompt# telnet 172.16.99.55 2. Enter the enable password at the prompt in order to enter the enable mode: Cat5500>enable Password: Cat5500>(enable) 3. Execute the show snmp command in order to display the current SNMP information and look for the community−access information. Here is an example: Cat5500> (enable) show snmp RMON: Enabled Extended RMON: Enabled Extended RMON Netflow: Enabled Extended RMON Vlanmode: Disabled Extended RMON Vlanagent: Disabled SPAN Configuration: Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config, entity,stpx,syslog Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24 Community−Access Community−String −−−−−−−−−−−−−−− −−−−−−−−−−−−−− read−only XXXX ("XXXX" is the Read−only community string) read−write YYYY ("YYYY" is the Read−write community string) read−write−all secret .... .... −−<snip>−− Modify SNMP Community Strings Complete these steps in order to modify SNMP community strings on a catalyst switch. 1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example): prompt# telnet 172.16.99.55 2. Enter the enable password at the prompt in order to enter the enable mode: Cat5500>enable Password: Cat5500> (enable) 3. In order to modify the Read−only (RO) community string, use this command: Cat5500> (enable) set snmp community read−only public where "public" is the Read−only community string. The command overwrites the existing community string if the switch has one. 4. In order to enable the Read−write (RW) community string, use this command: Cat5500> (enable) set snmp community read−write private
  • 11. where "private" is the Read−write community string. The command overwrites the existing community string if the switch has one. Note: Cat OS supports only one community string for each read−only, read−write and read−write−all communities. You can not configure multiple community strings, unlike Cisco IOS. 5. Execute the show snmp command in order to display the current SNMP information and look for the community−access information. Here is an example: Cat5500> (enable) show snmp RMON: Enabled Extended RMON: Enabled Extended RMON Netflow: Enabled Extended RMON Vlanmode: Disabled Extended RMON Vlanagent: Disabled SPAN Configuration: Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config, entity,stpx,syslog Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24 Community−Access Community−String −−−−−−−−−−−−−−−− −−−−−−−−−−−−− read−only public !−−− public is the modified Read−only community string read−write private !−−− private is the modified Read−write community string read−write−all secret .... .... −−<snip>−− Disable/Remove SNMP Community Strings Complete these steps in order to disable or remove SNMP community strings on a catalyst switch. 1. Telnet to the Catalyst Switch (the Catalyst 5500 is used in this example): prompt# telnet 172.16.99.55 2. Enter the enable password at the prompt in order to enter the enable mode: Cat5500>enable Password: Cat5500>(enable) 3. In order to delete/remove the Read−only (RO) community string, use this command: Cat5500> (enable) set snmp community read−only SNMP read−only community string cleared 4. In order to delete/remove the Read−write (RW) community string, use this command: Cat5500>(enable) set snmp community read−write SNMP read−write community string cleared 5. Verify that the community strings are deleted/removed. Here is an example: Cat5500> (enable) show snmp RMON: Enabled Extended RMON: Enabled
  • 12. Extended RMON Netflow: Enabled Extended RMON Vlanmode: Disabled Extended RMON Vlanagent: Disabled SPAN Configuration: Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config, entity,stpx,syslog Port Traps Enabled: 3/1−9,4/1−24,7/1−12,9/1−16,10/1−12,11/1−24 Community−Access Community−String −−−−−−−−−−−−−−−− −−−−−−−−−−−−− read−only read−write .... .... −−<snip>−− As you can see, the column for "Community−String" is blank. This indicates that both the read−only and read−write community strings are deleted or removed. Related Information • Cisco Security Advisory: Cisco IOS Software SNMP Read−Write ILMI Community String Vulnerability • Cisco Security Advisory: Cisco IOS Software Multiple SNMP Community String • Technical Support & Documentation − Cisco Systems Contacts & Feedback | Help | Site Map © 2011 − 2012 Cisco Systems, Inc. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks of Cisco Systems, Inc. Updated: Oct 26, 2005 Document ID: 7282