16. Results in reduced heat transfer into building, reducing cooling costsTraditional Dark Roof Absorbs 70% more Solar Energy Reflective White Cool Roofs C Can be %0* to 60*F Cooler
52. Extending the life of an existing building by conserving natural resources, qualifies for credit in the Material and Resource category. By using the existing roof, reduction of waste is achieved and applies to further credits within this category.Before After
53. URBAN HEAT ISLANDS The use of dark, non-reflective surfaces for parking, roofs, walkways and other surfaces contributes to heat island effects created when heat from the sun is absorbed and radiated back to surrounding areas. As a result of heat island effects, ambient temperatures in urban areas can be artificially elevated by more than 10 degrees when compared with surrounding suburban and undeveloped areas. This results in increased cooling loads in the summer, requiring larger HVAC equipment and energy for building operations. Heat island effects can be mitigated through the application of shading and the use of materials that reflect the sun’s heat instead of absorbing it. Heat Island Atlanta 1972 Heat Island Atlanta 1993 Causes: Urban Trees/Grass/Shrubs Reduction (56% of the cause) Dark Roads & Parking Spaces (6%) Buildings with Dark Roof Surfaces (38%) Dark Surface Temps 75* - 100*F Higher than ambient air temperature Increases A/C costs (+$5 BILLION per year) Increases Smog Premature roofing material deterioration Roof Top Effects On Urban Heat Islands Roofs are the hottest urban features 140* to 180*F at peak Roofs cover 20% of land area Difficult to shade large low slope roofs Cool Roofing can make a big impact 100*F to 120*F at peak for cool Roofs 50* drop over 20% of an urban area Note: Computer Simulations project Significant Impact on UHI turning roofs Black to White
62. Reduces the total cost of ownership for building owners by reducing life cycle costsElastomeric roof coating process: Vacuumed & Prepared Base Coat Top or Finish Coat
69. Coating: Apply a monolithic urethane coating across the entire roof using high quality compatible materialsBefore After
70. Environmental “Green” Advantages of Direct Bond Roofs Dade County approved; FM Global; UL rated; Energy Star rated; Cool Roof rated; Products LEED qualified Light reflective white coating (up to 94% solar reflectivity – SRI) One-part urethane membrane (toughest, most durable fluid-applied membrane on the market) Helps keep your building cooler (lower energy expense) Low odor Reduces hazardous waste disposal costs Less waste in landfills Renewable and sustainable roof system
71. TAX ADVANTAGES According to Sec. 1.162-4 Repairs of IRS Tax Code: Roof maintenance systems are fully tax deductable as an operating expense. One of the key advantages of a restoration system over a new roof system is in how it is classified by the IRS. Restoration is classified as a maintenance, and in most cases it can be expensed in the accounting period it is incurred. On the other hand a new roof system is a capital asset that must be amortized over a 39 year life.
73. A division of the Jones-Blair Corporation ELASTA-GARD DIRECT-BOND, FLUID-APPLIED ROOF SYSTEMS COMPATIBLE OVER: - BUILT-UP ROOFING (BUR) - MODIFIED BITUMEN (MB) - SINGLE-PLY - EPDM - METAL - CONCRETE
74. Urethane vsAcrylic Acrylics Tensile Strength – 300 psi Elongation – 300% Water Absorption – 20% Low Impact Resistance Suspect to Chemical Attack Urethane Tensile Strength – 1,500 psi Elongation – 360% Water Absorption - <3% High Impact Resistance Chemical Resistant Urethane is used exclusively for all Elasta-Gard Direct Bond Systems
75. ELASTA-GARD BUR/MB NEOGARD®’s Premier Roof Coating Membrane System Advantages: - Eliminates back-breaking tear-off of existing roof - Eliminates landfill costs. No disposal of old roofs - Sustainable and renewable, not replaced - NO SEAMS TO FAIL!! - All NEOGARD® products are Cool Roof, LEED qualified
76. Existing Mod-Bit Roof Failed Seams! “Fishmouth” Tear-off isn’t the only solution!!
78. NO SEAMS!!! Elasta-Gard BUR/MB (Heavy Traffic Fluid-Applied Roof System with Granules) ALL SEAMS ARE DETAILED AND TAPED IF NECESSARY Primer – 7780/7781; 1/3 gal/100 sq.ft. Base Coat – 39 dry mils of high quality urethane Topcoat – 21 dry mils of WHITE (COOL ROOF, LEED qualified) high quality urethane Granules broadcast to refusal on topcoat Total System Membrane Thickness Averages 60 dry mils
90. ELASTA-GARD M NEOGARD® Metal Roof Coating Membrane System York Label Company Kansas City, MO Curt Carpenter Owner - C&G COATINGS Your NEOGARD®Representative
125. If it’s good enough for the New Orleans Superdome……………….. Polyurethane Foam Base with NEOGARD®Urethane Coating Re-roofed after Hurricane Katrina damage in 2006
126. CURTCARPENTER C&G COATINGS Your NEOGARD® Representative Thank you for your time. Please feel free to contact me for an estimate or more information on the NEOGARD®product and application that’s right for you. 8228 Marshall Dr. Lenexa, KS 66214 913-438-2412 – office 913-634-2588 – cell 913-492-4362 – fax cgcoatings@kcnet.com www.cgcoatings.com www.neogard.com