5. CSP MAIN REFERENCES
Scope of Supply Operation Construction Planification Electrical Power
• INGETEAM CSP EXPERIENCE
EPC Power Block
Power Plant Engineering
Control System Supply
100 MW
Owner Engineering 140 MW
Solar Field Control System
150 MW
y
Supply
150 MW
Electrical System Supply 100 MW
Feasiblity Studies
Conceptual Engineering
360 MW
R&D F ibilt St diR&D Feasibilty Studies
Conceptual Engineering
19 MW
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
6. BIOMASS MAIN REFERENCES
Scope of Supply Operation Construction Planification Electrical Power
• INGETEAM BIOMASS EXPERIENCE
EPC
Power Plant Engineering
Control System Supply
10 MW
Basic design &
Owner Engineering
32 MW
Basic design 32 MW
Electrical & Control
equipment
27 MW
q p
Basic design and
administrative project
58 MW
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
9. HYBRID POWER PLANT BIOMASS – CSP CONCEPTION
RESOURCES USES
SOLARSOLAR
THERMAL
ENERGY
HYBRIDIZATION
• HTF
• STEAM
STORAGE • DSG
• STEAM CYCLE
BIOMASS
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
11. HYBRIDIZATION CONCEPT
CSPCSP
• ANNUAL POWER PLANT
FACTOR
BIOMASSBIOMASS
• ANNUAL POWER PLANT
FACTOR
HYBRIDIZATIONHYBRIDIZATION
• ANNUAL POWER PLANT
FACTOR
• 25-40 %
• CAPEX
• 3 5 €/W
• 89 %
• CAPEX
• 2 5 3 5 €/W
• 50 - 80 %
• CAPEX
• 3 5 €/W• 3 - 5 €/W • 2,5 – 3,5 €/W • 3 - 5 €/W
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
12. HYBRIDIZATION EXAMPLES DNI 2300 KWh/m2/year
SOLAR RESOURCE
± 2300 kWh/m2/year
SOLAR – BIOMASS BOILER: 70% - 30%
SOLAR - BIOMASS PERCENTAGE: 41% - 59%
• Annual Net Electrical Generation: 132,2 GweAnnual Net Electrical Generation: 132,2 Gwe
• Turbine gross power: 35 MWe
• Biomass consumption: 87,890 ton
• LCOE: 123 $/MWh
SOLAR – BIOMASS BOILER: 45% - 55%
SOLAR – BIOMASS PERCENTAGE: 20% - 80%
• Annual Net Electrical Generation: 146,6 Gwe
• Turbine gross power: 26 MWe
• Biomass consumption: 146,580 ton
SOLAR – BIOMASS BOILER: 45% - 55%
SOLAR BIOMASS PERCENTAGE 33% 67%
• LCOE: 110 $/MWh
SOLAR – BIOMASS PERCENTAGE: 33% - 67%
• Annual Net Electrical Generation: 175 Gwe
• Turbine gross power: 26 MWe
• Biomass consumption: 122 385 ton
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
• Biomass consumption: 122,385 ton
• LCOE: 123 $/MWh
13. HYBRIDIZATION EXAMPLES DNI 1950 KWh/m2/year
SOLAR RESOURCE
± 1950 kWh/m2/year
SOLAR – BIOMASS BOILER: 70% - 30%
SOLAR – BIOMASS PERCENTAGE: 39% - 61%
• Annual Net Electrical Generation: 128,42 GweAnnual Net Electrical Generation: 128,42 Gwe
• Turbine gross power: 35 MWe
• Biomass consumption: 89,540 ton
• LCOE: 130 $/MWh
SOLAR – BIOMASS BOILER: 45% - 55%
SOLAR – BIOMASS PERCENTAGE: 17% - 83%
• Annual Net Electrical Generation: 166,7 Gwe
• Turbine gross power: 26 MWe
• Biomass consumption: 150,700 ton
• LCOE: 120 $/MWh
SOLAR – BIOMASS BOILER: 45% - 55%
SOLAR BIOMASS PERCENTAGE 30% 70%SOLAR – BIOMASS PERCENTAGE: 30% - 70%
• Annual Net Electrical Generation: 173,8 Gwe
• Turbine gross power: 26 MWe
• Biomass consumption: 128 670 ton
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
• Biomass consumption: 128,670 ton
• LCOE: 132 $/MWh
14. LEC or LCOE, LEVELISED COST OF ENERGYPLANTS
Plant Type LCOE (USD/MWh)
Conventional Coal 110
Conventional Combined Cycle 110
Advanced Nuclear 120
Hydro 100
Biomass 110Biomass 110
Wind 115
Solar PV 120
Geothermal 130
CSP - Geothermal 130
Conventional CSP 140
Micro CSP 200
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
Source: EIA (Energy Information Administration), NREL
15. HYBRIDIZATION LCOE REDUCTION
CSP + TES
CSP
NUCLEAR
LCOE
PV
COAL
GAS BIOMASS
WIND
HYDRO
LOW POWER PLANT FACTOR HIGH POWER PLANT FACTOR
RICITYCOST
NUCLEAR
PV
CSP + TESWIND
CSPELECTRICITY COST LCOE TRANSMISSION COST
ELECTR
NUCLEAR
COAL
GAS
BIOMASSHYDRO
INGETEAM POWER TECHNOLOGY, S.A. – POWER PLANTS
LOW POWER PLANT FACTOR HIGH POWER PLANT FACTOR
16. THANK YOU FOR YOUR ATTENTION
Page.. negoitz.sanmiguel@ingeteam.com
Ingeteam Power Plants - Productos y Soluciones Pag. 16Junio 2011