20. Eagle Eye Inspection LLC
Summary
MLS discibes home as "triplewide home with approx.2816 sq ft.on permanent foundation". This is factually
inaccurate, the mobile home rests on concrete blocks, not a permanenet foundation. There is decorative
stone around the bottom of the home which looks very much like a stone foundation but is merely skirting on
The shingles installed are dimensional shingles. This is probably not the best choice for the 2/12 slope. There
is a missing shingle and deterioration in the valleys. And the overall installation appears shoddy, further
evaluation by a professional roofer is highly recommended.
Roof deck is sagging is several areas and appears that it is only 1/2".
There is no screen in the front/storm door, this door does not latch correctly either.
There are several open j boxes in the garage which are safety hazards. The furnace has romex wire nutted to
a cord, (not fused disconnect or switch). There is also no propane tank, the funace states that it is for NG,
and there is no sediment trap installed.Further evaluation by a professional electrician/HVAC tech should be
There is a dramatic difference between the 2 roof sections on the garage, Several shingles are missing on the
decking and the ridge cap. Shingles are nearing the end of their life cycle and will need to be replaced soon.
On the garage there are a few pcs of siding that are not attached properly, and there is a gap in the jchannel
near the shed that could allow moisture intrusions
There is no fascia cover and missing soffet on the rear of the garage. Some of the wood (peak of fascia) has
been replaced by diriving screw through the shingles.
There is no source of gas for the use of the fireplace.
One of the flourescent lighting fixtures in the kitchen is not working.
There are no racks in the oven, these could be costly and/or hard to find.
There is an icemaker but no waterline run, This may indicate that there is a problem with the ice maker.
The drain leading from the masterbath is tied up with romex, some of which has come loose causing the
drain line to sag in different areas. This could cause slow drainage or backups. A professional plumber should
MLS also lists the heater as a heat pump, this is also inaccurate the home has an electric furnace and a split
system central air conditioning system.
The AC unit is oversized for the home, this will lead to short cycling and will not properly reduce the humidity
There is no return air duct or vent in the non master bedrooms, this could lead to the room not being
properly heated or cooled.
You are advised to seek two professional opinions and acquire estimates of repair as to any defects,
comments, improvements or recommendations mentioned in this report. I recommend that the professional
making any repairs inspect the property further, in order to discover and repair problems that were not
identified in the report. I recommend that all repairs, corrections, and cost estimates be completed and
documented prior to closing or purchasing the property. Feel free to hire other professionals to inspect the