1. 1358-SERIES Data Sheet Ref. No : SU-1358-00001
Electrically Operated Plastic Ball MODEL NO.: SUDE
Valve Technical Specifications 135850PVCPVCTPROPBSPSD- PUNE /
1000-052LSPOTSERVOCPT200 BANGALORE
Quotation Ref. No
Quotation Date
1. ITEM ASSEMBLY OF 2 WAY PLASTIC BALL VALVE FITTED
WITH SINGLE PHASE QUARTER TURN ELECTRIC
ACTUATOR
2. MAKE SUDE
3 APPLICATION
6 TECHNICAL SPECIFICATION OF 2 WAY BALL VALVE
Valve Size 50mm
End connection BSP Screwed
Body Material PVC
Ball Material PVC
Seating material Teflon
Flowing medium Acid
Pressure 10 Bar
Temperature Ambient
Characteristic Proportionate
Sdtork Make Single Phase Quarter Turn Electric
Fitted with
Actuator Supply Voltage 230 V AC.
ACTUATOR DETAILS
3.1 Model SD-1000-05
3.2 Output motion type
3.3 Output Torque ( Nm )
3.4 Output speed ( Sec/90 °)
3.5 Manual hand wheel PROVIDED
3.6 Travel limit switches Type : 1 NO + 1 NC, change over contact, contact rating: 5 A, 230
2 Nos V AC
3.7 Torque limit switches Not required, AS 1000-series actuator are provided with stall duty
motor
3.8 Local indicator PROVIDED
3.9 Class of Protection IP65
3.10 Weight of the actuator (Kgs.)
3.11 Duty
3.12 Mounting
3.14 G. A. Drawing Reference No
3.15 Electrical Wiring Diagram Ref, No
3.16 Weight of Actuator – Kgs
MOTOR DETAILS
4.1 Type Reversible Single Phase Synchronous Stall Duty Motor
4.2 Supply 230 V +/- 10 %, 50 Hz +/- 5 % AC Supply
4.3 Duty S2-10 min / S-4-30 % 1200 Cycles/ hr.
4.4 Insulation Class F
4.5 Rating ( Watts)
OPTIONAL ACCESSORIES
2. 5.1 Feedback Out put : 100-235 Ohms Provided
Potentiometer
5.2 Additional Limit Qty : 2 nos. Provided
Switches Type : 1 NO + 1 NC, Change over contact,
Contact rating: 5 A, 230VAC
5.3 Two Wire Transmitter Type : Two wire, Actuator mounted Provided
Supply : 12-36 VDC, Output : 4-20 m A
5.4 Remote Position Available in servo controller Provided
indicator Digital : 0-100 %
5.5 Servo controller Input signal : 4-20 m A, Output : 4-20 m A Provided
(Valve positioner) Feed back : 0-500 Ohms, supply 230 V AC,
Panel Mounted This will have auto calibration facility.
5.6 Interface Card Input signal : 4-20 m A, Provided
Feed back : 100-235 Ohms,
5.7 Local Push Button This will consist of Auto /Off / Manual Provided
Station selector switch, Open/Close push buttons.
6 GENERAL POINTS
6.1 Inspection By Customer at our works
6.2 T. C.& Manuals 2 Sets with unit
6.3 Warranty 18 months from the date of supply or 12 months from the date of installation
which ever is earlier.
6.4 Packing Thermo cool Packing Housed in corrugated Box
SPECIAL NOTE :