WHITE PAPER ON:




    The Dielectric Voltage Withstand Test
    Benefits and limitations



The dielectric voltage withstand test is an integral part of the           The performance of conductive materials is in marked contrast to
product safety evaluation of electrical and electronic devices,            that of insulating materials, which have a physical structure that
and provides manufacturers with important information                      prevents the easy movement of electrons. Since the electrons
regarding the quality and appropriateness of the chosen                    cannot move freely, they cannot effectively carry charge through
insulation system. The test involves placing an extra-high                 the material. However, it is always possible to force the material to
voltage across the insulation barrier of the device for one                conduct by exposing it to sufficiently high voltage.
minute. If the insulation holds the voltage, the device is
deemed to have passed the test. However, if the applied                    The theory of dielectric breakdown
voltage leads to the sudden breakdown of the insulation
                                                                           The dielectric breakdown of an insulating material is a complex
material and allows current to flow, the insulation is determined
                                                                           physical phenomenon but it may be generally characterized as a
to be insufficient since it might pose a shock hazard to users.
                                                                           sudden change in the resistance of the insulation under test due to
                                                                           the applied voltage. Simply stated, the test voltage breaks down the
While the dielectric voltage withstand test is widely used, the real
                                                                           insulating properties of the material.
objective of the test is often misunderstood, which may lead to
incomplete testing or misleading test results. This white paper seeks      The mechanism of dielectric breakdown begins with the application
to clarify the theory of dielectric breakdown and the objective of the     of a strong electric field to the insulating material by a high voltage.
dielectric voltage withstand test. It explores the applications and        Different materials require different levels of electric field in order
limitations of the test in order to better ensure its appropriate use in   for dielectric breakdown to occur. Metals and other conductors
the product safety approval process.                                       have free electrons without the application of any electric field, but
                                                                           insulating materials typically require a very high electric field to allow
The mechanism of insulating materials                                      electrical current to flow.
Current flows in a material when an electromotive force is applied
                                                                           When the electric field is sufficient, it energizes the insulator’s
that is strong enough to force the movement of electric charge.
                                                                           electrons until they gain enough energy to cross the bandgap
This charge movement is carried by electrons in the material, and
                                                                           and move into the conduction band, dramatically increasing the
can be measured as electric current. Metals, such as copper, have
                                                                           conductivity of the material. This transformation is called dielectric
many free electrons available to transfer electric charge. This makes
                                                                           breakdown and the electric field necessary to start the breakdown is
copper a good conductor because there is little resistance to the
                                                                           called the dielectric strength, or breakdown strength.
flow of charge and the energy lost as heat, due to current is minimal.
                                                                           Thus, dielectric breakdown is a dramatic and sudden increase in the
                                                                           conductivity of a material due to an applied voltage.




    01           For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
Leakage current vs. dielectric current                                     to the increased voltage. Using the example from above, a device
                                                                           with a leakage current of 0.5mA at 120 Vac would be expected to
Figure 1 illustrates a simple insulation model which applies to every
                                                                           have approximately 5.2mA dielectric current during a 1240 Vac
electrical and electronic device.
                                                                           dielectric test.

                                                                           To avoid confusion, this paper uses the term “leakage current” when
                                                                           describing leakage current when the circuit is at rated voltage and
                                                                           “dielectric current” when describing the analogous current when the
 Spark Gap                          Resistor
                                                                           circuit is exposed to the dielectric test voltage.
                                                           Capacitor
                                                                           The dielectric strength test is not intended to evaluate the amount
                                                                           of leakage current, as these two tests have fundamentally different
                                                                           objectives and compliance criteria. The leakage current limit is only
                                                                           applicable to the leakage current test, and only at the rated voltage.


                                                                           Objective of the dielectric voltage withstand test
Figure 1: Basic insulation scheme in electrical products
                                                                           The human heart is controlled by the body’s nervous system using
The resistor accounts for resistive current through the insulation         electrical impulses. Even small currents passing through the heart
and the capacitor accounts for capacitively coupled currents. For          can interrupt this control, leading to ventricular fibrillation and in
modern insulation material, the insulation resistance is very large,       the most severe instances, to death. Thus, the most fundamental
so resistive current is typically several orders of magnitude lower        requirement of electrical safety is to provide sufficient separation
than the capacitively coupled current. The spark gap represents the        between the human body and hazardous currents to avoid
avalanche (breakdown) phenomenon, where a good insulator turns             interrupting the heart’s normal function.
bad after a certain voltage is reached.
                                                                           In addition to ventricular fibrillation, the human body may also exhibit
When a voltage is applied to an electrical or electronic device, the       an involuntary startle reaction and/or muscle contraction in reaction
natural capacitance of the insulation charges, resulting in the flow       to currents that pass through parts of the body. These reactions
of current. If a DC voltage is applied, the charging occurs only when      can lead to hazards from the uncontrolled body movements than
voltage is first applied. The DC voltage charges the capacitance and       can occur when a person is subjected to the unpleasant nerve and
the capacitive charging current is then reduced to near zero.              muscle stimulation of electric current. Current passing through the
                                                                           body may also cause muscle contractions that make it impossible to
For 60 Hz AC voltages, the charging and discharging of this                let go of the electrical source.
capacitance occurs 60 times each second, so the capacitive
charging current remains at a steady-state level and never goes            Protecting humans from hazardous currents is typically
to zero. This is known as capacitive leakage current. For modern           accomplished by preventing contact with any electrical circuits that
electronic devices, the resistive leakage current is normally very         carry sufficient voltage and current to shock the user. To isolate
small, so the overall leakage current of such devices is dominated         these circuits from human contact, electrical and electronic devices
by the capacitive effect. To protect users from injury, many product       employ electrical insulation, the quality of which must be sufficient for
safety standards set limits for the allowable leakage current. A typical   the working voltage throughout the expected life of the device. The
leakage current limit is 0.5mA at 60 Hz and at the rated voltage.          dielectric voltage withstand test is performed in order to verify the
                                                                           capability of the insulation.
Electrical and electronic devices also exhibit current analogous
to leakage current during dielectric testing. However, since the
dielectric test voltage is much higher, the current will be higher as
well because the capacitive charging current increases in proportion




     02               For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
Air is the most readily available electrical insulator, and through-air    The problem of false failures
spacing requirements (also known as “clearance”) are defined in many
                                                                           The use of a trip current setting to determine dielectric breakdown
product safety standards in order to maintain voltage separation.
                                                                           is based on the assumption that current above the trip setting is
Spacings across the surface of an insulating material are known as
                                                                           indicative of dielectric breakdown. While this is true in many cases,
over-surface spacings or “creepage” and are often defined in applicable
                                                                           there are instances in which a current above the trip-out threshold
standards. However, even in cases where a device complies with the
                                                                           is not indicative of a breakdown at all. It may actually be reflective of
defined through-air and over-surface spacing requirements, the overall
                                                                           the natural dielectric current of the tested device. Thus, the following
insulation system must be tested by the application of the dielectric
                                                                           dilemma: trip-out might indicate dielectric breakdown (a failure
voltage withstand test to the insulation system.
                                                                           condition) or it might merely indicate dielectric current above the trip-
The applied voltage for the dielectric voltage withstand test is usually   current setting (not a failure condition). This uncertainty may lead to
much higher than the working voltage of the device to accommodate          test results deemed unacceptable, when the results actually mask a
transient overvoltages, such as voltage surges and switching               favorable outcome. (See Figures 2 and 3)
transients. This provides a safety margin for production variations
and the aging of the material.
                                                                                                                         Trip-out gives a
                                                                                                                          False Failure
The objective of the dielectric voltage withstand test is to establish
the minimum level of electrical insulation necessary to prevent                                   Improper Trip Current Setting
                                                                             Dielectric Current
human contact with a potentially harmful voltage and resulting
current. In addition, the dielectric voltage withstand test may reveal
faults in mechanically damaged insulation or the presence of a
foreign material (such as water) which may bridge the insulation. This
test is often used after mechanical abuse or temperature tests to
confirm that the product has maintained its insulating capabilities.

The dielectric voltage withstand test is also used on the
manufacturing production line to identify material and workmanship
                                                                                                         120 V                              1240 V
defects in assembled devices.                                                                                            Applied Voltage
                                                                             Figure 2
Trip current during the dielectric voltage withstand test
When dielectric breakdown occurs, the loss of the insulation
material’s resistance causes the current to go from a low dielectric
current level to a much higher breakdown current. This change in
the level of dielectric current has traditionally been monitored by a                             Trip Current Setting

current-sensitive circuit, which trips-out the test equipment when                                                          Trip-out
                                                                             Dielectric Current




the current exceeds the test equipment’s trip sensitivity setting.                                                         indicates
This approach has the significant advantages of being simple and                                                          breakdown
inexpensive and has been used for many years. However, although
this method works reasonably well a closer analysis reveals potential
limits to its use.
                                                                                                                              Breakdown




                                                                                                         120 V                              1240 V
                                                                             Figure 3                                    Applied Voltage




    03           For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
Because the dielectric test is intended to evaluate the insulation            With a DC test, steady-state dielectric current will be much lower
system, no limit is specified for dielectric current. Thus, there is no       because the product’s capacitance is charged only once. This
correct trip-out current setting for determining failure. In practice,        occurs at the beginning of the voltage application. If the test voltage
the only valid determining criterion for failure is “breakdown.” The          is raised slowly, the charging current will be low and, once the test
precise value of dielectric current which flows is unimportant;               voltage stabilizes, there will be very little current flow. This is an
what is important is the sudden, dramatic increase in the dielectric          advantage because the trip-out limit of the dielectric tester can be
current, indicating that insulation breakdown has occurred. It is for         set lower without causing false alarms.
this reason that most product safety standards do not specify a trip
current threshold for the dielectric test.                                    If the voltage is ramped up too quickly, the capacitive charging
                                                                              current may create false failures. Trip-out during DC voltage ramp-up
However, if the expected leakage current is known, then a common              must be examined to determine if the cause of the trip-out is normal
procedure is to set the trip-out threshold at 20 times the maximum            charging current. Repeating the test with a doubled ramp time may
leakage current limit. This multiplier includes a factor of 10 for the        provide a simple testing solution.
approximate ratio of the dielectric test voltage divided by the normal
operating voltage, and a factor of 2 for variability. If the current           Some products contain electromagnetic interference filters, which
exceeds this higher trip-out level, it is likely the result of a dielectric   may add capacitance. To accommodate these filters, the leakage
failure, and not the expected current flowing in the leakage current          current limit in some product safety standards is 3.5 mA. The
path from the application of the dielectric test voltage.                     expected current during a dielectric test might be as high as 3.5
                                                                              mA times 1240 V / 120V = 36 mA ac rms. With this heavy loading,
To summarize, tripping of the dielectric tester only signifies that           some dielectric testers are not able to deliver enough voltage across
the trip current setting of the tester has been exceeded. Therefore,          the terminals to perform the test. However, if a DC test is used, the
this result should not be automatically interpreted to mean that              capacitive current is just the one-time charging current. Once the
breakdown has occurred and further testing or evaluation should               capacitance is charged, the dielectric tester requires only a small
be conducted. This further evaluation may include several different           current load that the tester can easily supply. In the case of high
investigative paths, including DC dielectric testing, use of dielectric       leakage current limits, replacing the AC test with a DC test may be
testers with arc detection, specialized diagnostic testers and                necessary, unless the AC dielectric tester has enough capacity to
reapplication of the dielectric withstand test voltage to locate the site     deliver the test voltage under heavy current load.
of the breakdown.
                                                                              There is one disadvantage to DC testing, which becomes evident at
                                                                              the end of the test. Once DC testing has been completed, the inherent
AC vs. DC dielectric testing
                                                                              capacitance of the device under test has been fully charged and now
The objective of dielectric testing can be met with DC as well as AC          poses a potential shock hazard. Accordingly, certain products may
voltages. In fact, many product safety standards already include              need to be discharged via a short with a bleeder resistor, adding
DC voltages in their dielectric test methods. When testing with DC            another step and complexity to the DC dielectric test.
voltage, the metered voltage must be set for a voltage equal to 1.414
times the AC test voltage, since the AC voltage measurement is an
RMS value. The actual peak voltages from the AC wave are 1.414
times the metered AC RMS value. Thus, the DC test voltage is equal
to the highest peak AC voltage.




    04            For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
Summary
The dielectric voltage withstand test can provide important insight
into the capabilities and limits of a device’s insulation system.
However, it is important to remember that the objective of the test
is only to evaluate the insulation’s electrical strength. The current
during the dielectric test should not be evaluated against the device’s
leakage current limits, since the dielectric test is performed at a
much higher voltage.

It is common for dielectric test equipment to use a current trip-out
limit to indicate dielectric failure. When the tripping device is properly
set to allow the expected current to flow through an acceptable
dielectric current path, the dielectric test equipment will give
trustworthy results. However, in cases where the expected current is
not known or the trip-out threshold is selected generically, the trip-
out may produce a false failure result. Thus, trip-out by itself should
not be assumed to indicate a true dielectric breakdown.

An indication of trip-out should always be followed by an
investigation into the root cause of the trip-out. Such an investigation
will then lead to an invaluable discussion as to the fundamental
quality of the device’s electrical insulation system.

For additional information about The Dielectric Voltage Withstand
Test — Benefits and Limitations white paper, please contact
Dale Hallerberg, Research Engineer at Underwriters Laboratories:
dale.a.hallerberg@us.ul.com




    05            For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
                                                  Copyright © 2010 Underwriters Laboratories Inc. All rights reserved. No part of this document may be copied or distributed without the prior written consent of Underwriters Laboratories Inc.12/10 BDI 100807.8

Weitere ähnliche Inhalte

Was ist angesagt?

Resistance In Circuits
Resistance In CircuitsResistance In Circuits
Resistance In CircuitsDavid Ramirez
 
12th Physics Investigatory project (LDR)
12th Physics Investigatory project (LDR)12th Physics Investigatory project (LDR)
12th Physics Investigatory project (LDR)ismail11112
 
Passive circuit elements
Passive circuit elementsPassive circuit elements
Passive circuit elementshepzijustin
 
Teacher presentation
Teacher presentationTeacher presentation
Teacher presentationKarunai Doss
 
Electronics class10
Electronics class10Electronics class10
Electronics class10Anubhav Jain
 
Photo resistor devices its working and applications.
Photo resistor devices its working and applications.Photo resistor devices its working and applications.
Photo resistor devices its working and applications.Soudip Sinha Roy
 
Led charactristics
Led charactristicsLed charactristics
Led charactristicsDinesh Kumar
 
Simulation of Induction heater using IRFZ44N MOSFET
Simulation of Induction heater using IRFZ44N MOSFETSimulation of Induction heater using IRFZ44N MOSFET
Simulation of Induction heater using IRFZ44N MOSFETanjeana
 
Chapter12 manufacturing-processes
Chapter12 manufacturing-processesChapter12 manufacturing-processes
Chapter12 manufacturing-processesVin Voro
 
Gcse design & technology
Gcse design & technologyGcse design & technology
Gcse design & technologyQwizdom UK
 
Physics investigatory project
Physics investigatory projectPhysics investigatory project
Physics investigatory projectNIKHIL DWIVEDI
 
Phyin c19 practical electricity
Phyin c19 practical electricityPhyin c19 practical electricity
Phyin c19 practical electricityDeclan Burke
 

Was ist angesagt? (20)

Resistance In Circuits
Resistance In CircuitsResistance In Circuits
Resistance In Circuits
 
12th Physics Investigatory project (LDR)
12th Physics Investigatory project (LDR)12th Physics Investigatory project (LDR)
12th Physics Investigatory project (LDR)
 
Resistor
ResistorResistor
Resistor
 
Passive circuit elements
Passive circuit elementsPassive circuit elements
Passive circuit elements
 
Teacher presentation
Teacher presentationTeacher presentation
Teacher presentation
 
Electronics class10
Electronics class10Electronics class10
Electronics class10
 
Insulation Testing
Insulation TestingInsulation Testing
Insulation Testing
 
Photo resistor devices its working and applications.
Photo resistor devices its working and applications.Photo resistor devices its working and applications.
Photo resistor devices its working and applications.
 
Lecture 17
Lecture 17Lecture 17
Lecture 17
 
Led charactristics
Led charactristicsLed charactristics
Led charactristics
 
LDR PROJECT-2
LDR PROJECT-2LDR PROJECT-2
LDR PROJECT-2
 
Laser diode
Laser diodeLaser diode
Laser diode
 
Simulation of Induction heater using IRFZ44N MOSFET
Simulation of Induction heater using IRFZ44N MOSFETSimulation of Induction heater using IRFZ44N MOSFET
Simulation of Induction heater using IRFZ44N MOSFET
 
Report
ReportReport
Report
 
Chapter12 manufacturing-processes
Chapter12 manufacturing-processesChapter12 manufacturing-processes
Chapter12 manufacturing-processes
 
Electronic letter box
Electronic letter boxElectronic letter box
Electronic letter box
 
Gcse design & technology
Gcse design & technologyGcse design & technology
Gcse design & technology
 
Physics investigatory project
Physics investigatory projectPhysics investigatory project
Physics investigatory project
 
Phyin c19 practical electricity
Phyin c19 practical electricityPhyin c19 practical electricity
Phyin c19 practical electricity
 
Electronic passive components
Electronic passive componentsElectronic passive components
Electronic passive components
 

Andere mochten auch

The Dielectric Voltage Withstand Test Executive Summary
The Dielectric Voltage Withstand Test Executive SummaryThe Dielectric Voltage Withstand Test Executive Summary
The Dielectric Voltage Withstand Test Executive SummaryUnderwriters Laboratories
 
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...Gururaj B Rawoor
 
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv Jimit
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv JimitPRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv Jimit
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv JimitJimit Dhruv
 
C++ Programming Language
C++ Programming Language C++ Programming Language
C++ Programming Language Mohamed Loey
 
Introduction to medical equipments safety and testing
Introduction to medical equipments safety and testingIntroduction to medical equipments safety and testing
Introduction to medical equipments safety and testingMEHABOOB RAHMAN
 
Basics of c++ Programming Language
Basics of c++ Programming LanguageBasics of c++ Programming Language
Basics of c++ Programming LanguageAhmad Idrees
 

Andere mochten auch (7)

The Dielectric Voltage Withstand Test Executive Summary
The Dielectric Voltage Withstand Test Executive SummaryThe Dielectric Voltage Withstand Test Executive Summary
The Dielectric Voltage Withstand Test Executive Summary
 
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...
Built-in Novel Insulation Monitoring Function for RIF Paperless Transformer B...
 
TRANSFORMERS
TRANSFORMERSTRANSFORMERS
TRANSFORMERS
 
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv Jimit
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv JimitPRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv Jimit
PRESENTATION ON MANUFACTURING OF TRANSFORMER By Dhruv Jimit
 
C++ Programming Language
C++ Programming Language C++ Programming Language
C++ Programming Language
 
Introduction to medical equipments safety and testing
Introduction to medical equipments safety and testingIntroduction to medical equipments safety and testing
Introduction to medical equipments safety and testing
 
Basics of c++ Programming Language
Basics of c++ Programming LanguageBasics of c++ Programming Language
Basics of c++ Programming Language
 

Ähnlich wie Dielectric Voltage Withstand White Paper: Understanding the Test and its Limitations

Physics ohm’s law
Physics   ohm’s lawPhysics   ohm’s law
Physics ohm’s lawfourangela
 
Type and application of dielectric
Type and application of dielectricType and application of dielectric
Type and application of dielectricraj_sevak
 
Electrical properies of the tissues
Electrical properies of the tissuesElectrical properies of the tissues
Electrical properies of the tissuesJuliana Knocikova
 
Dielectric Materials types & properties, adavantages, lossess
Dielectric Materials types & properties, adavantages, lossessDielectric Materials types & properties, adavantages, lossess
Dielectric Materials types & properties, adavantages, lossessSANGRAMJADHAV49
 
Dielectric Material, Properties & Applications
Dielectric Material, Properties & ApplicationsDielectric Material, Properties & Applications
Dielectric Material, Properties & ApplicationsSANGRAMJADHAV49
 
Current, resistance and electromotive force
Current, resistance and electromotive forceCurrent, resistance and electromotive force
Current, resistance and electromotive forceChristian Costa
 
Highvolatage enegineering updated.pptx
Highvolatage enegineering updated.pptxHighvolatage enegineering updated.pptx
Highvolatage enegineering updated.pptxLavanyaUj
 
AET610 Module I.pptx
AET610 Module I.pptxAET610 Module I.pptx
AET610 Module I.pptxMoathalHayek1
 
Paper Electron Tube Afs Epri R5
Paper   Electron Tube   Afs Epri R5Paper   Electron Tube   Afs Epri R5
Paper Electron Tube Afs Epri R5John Kappenman
 
Dielectric Spectroscopy in Time and Frequency Domain
Dielectric Spectroscopy in Time and Frequency DomainDielectric Spectroscopy in Time and Frequency Domain
Dielectric Spectroscopy in Time and Frequency DomainGirish Gupta
 
Ramakrishna notes.pdf
Ramakrishna notes.pdfRamakrishna notes.pdf
Ramakrishna notes.pdfJayakumar T
 
Current Electricity Chp-8 General Science 9th 10th
Current Electricity Chp-8 General Science 9th 10thCurrent Electricity Chp-8 General Science 9th 10th
Current Electricity Chp-8 General Science 9th 10thKamran Abdullah
 
DIELECTRIC..........................pptx
DIELECTRIC..........................pptxDIELECTRIC..........................pptx
DIELECTRIC..........................pptxrenliejanepedronan
 
Wireless Power Transmission through TESLA COILS
Wireless Power Transmission through TESLA COILS Wireless Power Transmission through TESLA COILS
Wireless Power Transmission through TESLA COILS Naila Syed
 
Different Types of Power Problems
Different Types of Power ProblemsDifferent Types of Power Problems
Different Types of Power ProblemsChintan Patel
 

Ähnlich wie Dielectric Voltage Withstand White Paper: Understanding the Test and its Limitations (20)

Physics ohm’s law
Physics   ohm’s lawPhysics   ohm’s law
Physics ohm’s law
 
dielectric materials
dielectric materialsdielectric materials
dielectric materials
 
dieletric materials
dieletric materialsdieletric materials
dieletric materials
 
Type and application of dielectric
Type and application of dielectricType and application of dielectric
Type and application of dielectric
 
UNIT I - HVE.ppt
UNIT I - HVE.pptUNIT I - HVE.ppt
UNIT I - HVE.ppt
 
Electrical properies of the tissues
Electrical properies of the tissuesElectrical properies of the tissues
Electrical properies of the tissues
 
Dielectric Materials types & properties, adavantages, lossess
Dielectric Materials types & properties, adavantages, lossessDielectric Materials types & properties, adavantages, lossess
Dielectric Materials types & properties, adavantages, lossess
 
Dielectric Material, Properties & Applications
Dielectric Material, Properties & ApplicationsDielectric Material, Properties & Applications
Dielectric Material, Properties & Applications
 
Current, resistance and electromotive force
Current, resistance and electromotive forceCurrent, resistance and electromotive force
Current, resistance and electromotive force
 
Highvolatage enegineering updated.pptx
Highvolatage enegineering updated.pptxHighvolatage enegineering updated.pptx
Highvolatage enegineering updated.pptx
 
AET610 Module I.pptx
AET610 Module I.pptxAET610 Module I.pptx
AET610 Module I.pptx
 
Paper Electron Tube Afs Epri R5
Paper   Electron Tube   Afs Epri R5Paper   Electron Tube   Afs Epri R5
Paper Electron Tube Afs Epri R5
 
Dielectric Spectroscopy in Time and Frequency Domain
Dielectric Spectroscopy in Time and Frequency DomainDielectric Spectroscopy in Time and Frequency Domain
Dielectric Spectroscopy in Time and Frequency Domain
 
Corrosion Report
Corrosion ReportCorrosion Report
Corrosion Report
 
DIELECTRIC MATERIALS.pptx
DIELECTRIC MATERIALS.pptxDIELECTRIC MATERIALS.pptx
DIELECTRIC MATERIALS.pptx
 
Ramakrishna notes.pdf
Ramakrishna notes.pdfRamakrishna notes.pdf
Ramakrishna notes.pdf
 
Current Electricity Chp-8 General Science 9th 10th
Current Electricity Chp-8 General Science 9th 10thCurrent Electricity Chp-8 General Science 9th 10th
Current Electricity Chp-8 General Science 9th 10th
 
DIELECTRIC..........................pptx
DIELECTRIC..........................pptxDIELECTRIC..........................pptx
DIELECTRIC..........................pptx
 
Wireless Power Transmission through TESLA COILS
Wireless Power Transmission through TESLA COILS Wireless Power Transmission through TESLA COILS
Wireless Power Transmission through TESLA COILS
 
Different Types of Power Problems
Different Types of Power ProblemsDifferent Types of Power Problems
Different Types of Power Problems
 

Mehr von Underwriters Laboratories

Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...
Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...
Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...Underwriters Laboratories
 
Pharmaceuticals and Personal Care Products in Drinking Water
Pharmaceuticals and Personal Care Products in Drinking WaterPharmaceuticals and Personal Care Products in Drinking Water
Pharmaceuticals and Personal Care Products in Drinking WaterUnderwriters Laboratories
 
Applied Safety Science and Engineering Techniques (ASSET)
Applied Safety Science and Engineering Techniques (ASSET)Applied Safety Science and Engineering Techniques (ASSET)
Applied Safety Science and Engineering Techniques (ASSET)Underwriters Laboratories
 
Ul wp final_medical device approvals in brazil_v6
Ul wp final_medical device approvals in brazil_v6Ul wp final_medical device approvals in brazil_v6
Ul wp final_medical device approvals in brazil_v6Underwriters Laboratories
 
Eu approval of host devices with integrated wireless modules v5
Eu approval of host devices with integrated wireless modules v5Eu approval of host devices with integrated wireless modules v5
Eu approval of host devices with integrated wireless modules v5Underwriters Laboratories
 
A new approach to safety for a v and ict equipment-iec 62368-1 v6
A new approach to safety  for a v and ict equipment-iec 62368-1 v6A new approach to safety  for a v and ict equipment-iec 62368-1 v6
A new approach to safety for a v and ict equipment-iec 62368-1 v6Underwriters Laboratories
 
The Life Cycle of Materials -- How New Phone Technology Affects the Environment
The Life Cycle of Materials -- How New Phone Technology Affects the EnvironmentThe Life Cycle of Materials -- How New Phone Technology Affects the Environment
The Life Cycle of Materials -- How New Phone Technology Affects the EnvironmentUnderwriters Laboratories
 
UL White Paper - Revisiting Flammable Refrigerants
UL White Paper - Revisiting Flammable RefrigerantsUL White Paper - Revisiting Flammable Refrigerants
UL White Paper - Revisiting Flammable RefrigerantsUnderwriters Laboratories
 
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...Underwriters Laboratories
 
New safety standard for high tech products accommodates future
New safety standard for high tech products accommodates futureNew safety standard for high tech products accommodates future
New safety standard for high tech products accommodates futureUnderwriters Laboratories
 

Mehr von Underwriters Laboratories (13)

UL-2015-Annual-Report_11x8_V5-compressed
UL-2015-Annual-Report_11x8_V5-compressedUL-2015-Annual-Report_11x8_V5-compressed
UL-2015-Annual-Report_11x8_V5-compressed
 
Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...
Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...
Moving From Contactless to Wireless Technologies in Secure, Over-the-Air Tran...
 
Pharmaceuticals and Personal Care Products in Drinking Water
Pharmaceuticals and Personal Care Products in Drinking WaterPharmaceuticals and Personal Care Products in Drinking Water
Pharmaceuticals and Personal Care Products in Drinking Water
 
Applied Safety Science and Engineering Techniques (ASSET)
Applied Safety Science and Engineering Techniques (ASSET)Applied Safety Science and Engineering Techniques (ASSET)
Applied Safety Science and Engineering Techniques (ASSET)
 
Smoke Alarms and the Modern Residence Fire
Smoke Alarms and the Modern Residence FireSmoke Alarms and the Modern Residence Fire
Smoke Alarms and the Modern Residence Fire
 
Ul wp final_medical device approvals in brazil_v6
Ul wp final_medical device approvals in brazil_v6Ul wp final_medical device approvals in brazil_v6
Ul wp final_medical device approvals in brazil_v6
 
Eu approval of host devices with integrated wireless modules v5
Eu approval of host devices with integrated wireless modules v5Eu approval of host devices with integrated wireless modules v5
Eu approval of host devices with integrated wireless modules v5
 
A new approach to safety for a v and ict equipment-iec 62368-1 v6
A new approach to safety  for a v and ict equipment-iec 62368-1 v6A new approach to safety  for a v and ict equipment-iec 62368-1 v6
A new approach to safety for a v and ict equipment-iec 62368-1 v6
 
The Life Cycle of Materials -- How New Phone Technology Affects the Environment
The Life Cycle of Materials -- How New Phone Technology Affects the EnvironmentThe Life Cycle of Materials -- How New Phone Technology Affects the Environment
The Life Cycle of Materials -- How New Phone Technology Affects the Environment
 
UL White Paper - Revisiting Flammable Refrigerants
UL White Paper - Revisiting Flammable RefrigerantsUL White Paper - Revisiting Flammable Refrigerants
UL White Paper - Revisiting Flammable Refrigerants
 
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...
UL Executive Summary - Revisiting Flammable Refrigerants in HVAC Equipment an...
 
Safety Issues for Lithium-Ion Batteries
Safety Issues for Lithium-Ion BatteriesSafety Issues for Lithium-Ion Batteries
Safety Issues for Lithium-Ion Batteries
 
New safety standard for high tech products accommodates future
New safety standard for high tech products accommodates futureNew safety standard for high tech products accommodates future
New safety standard for high tech products accommodates future
 

Dielectric Voltage Withstand White Paper: Understanding the Test and its Limitations

  • 1. WHITE PAPER ON: The Dielectric Voltage Withstand Test Benefits and limitations The dielectric voltage withstand test is an integral part of the The performance of conductive materials is in marked contrast to product safety evaluation of electrical and electronic devices, that of insulating materials, which have a physical structure that and provides manufacturers with important information prevents the easy movement of electrons. Since the electrons regarding the quality and appropriateness of the chosen cannot move freely, they cannot effectively carry charge through insulation system. The test involves placing an extra-high the material. However, it is always possible to force the material to voltage across the insulation barrier of the device for one conduct by exposing it to sufficiently high voltage. minute. If the insulation holds the voltage, the device is deemed to have passed the test. However, if the applied The theory of dielectric breakdown voltage leads to the sudden breakdown of the insulation The dielectric breakdown of an insulating material is a complex material and allows current to flow, the insulation is determined physical phenomenon but it may be generally characterized as a to be insufficient since it might pose a shock hazard to users. sudden change in the resistance of the insulation under test due to the applied voltage. Simply stated, the test voltage breaks down the While the dielectric voltage withstand test is widely used, the real insulating properties of the material. objective of the test is often misunderstood, which may lead to incomplete testing or misleading test results. This white paper seeks The mechanism of dielectric breakdown begins with the application to clarify the theory of dielectric breakdown and the objective of the of a strong electric field to the insulating material by a high voltage. dielectric voltage withstand test. It explores the applications and Different materials require different levels of electric field in order limitations of the test in order to better ensure its appropriate use in for dielectric breakdown to occur. Metals and other conductors the product safety approval process. have free electrons without the application of any electric field, but insulating materials typically require a very high electric field to allow The mechanism of insulating materials electrical current to flow. Current flows in a material when an electromotive force is applied When the electric field is sufficient, it energizes the insulator’s that is strong enough to force the movement of electric charge. electrons until they gain enough energy to cross the bandgap This charge movement is carried by electrons in the material, and and move into the conduction band, dramatically increasing the can be measured as electric current. Metals, such as copper, have conductivity of the material. This transformation is called dielectric many free electrons available to transfer electric charge. This makes breakdown and the electric field necessary to start the breakdown is copper a good conductor because there is little resistance to the called the dielectric strength, or breakdown strength. flow of charge and the energy lost as heat, due to current is minimal. Thus, dielectric breakdown is a dramatic and sudden increase in the conductivity of a material due to an applied voltage. 01 For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
  • 2. Leakage current vs. dielectric current to the increased voltage. Using the example from above, a device with a leakage current of 0.5mA at 120 Vac would be expected to Figure 1 illustrates a simple insulation model which applies to every have approximately 5.2mA dielectric current during a 1240 Vac electrical and electronic device. dielectric test. To avoid confusion, this paper uses the term “leakage current” when describing leakage current when the circuit is at rated voltage and “dielectric current” when describing the analogous current when the Spark Gap Resistor circuit is exposed to the dielectric test voltage. Capacitor The dielectric strength test is not intended to evaluate the amount of leakage current, as these two tests have fundamentally different objectives and compliance criteria. The leakage current limit is only applicable to the leakage current test, and only at the rated voltage. Objective of the dielectric voltage withstand test Figure 1: Basic insulation scheme in electrical products The human heart is controlled by the body’s nervous system using The resistor accounts for resistive current through the insulation electrical impulses. Even small currents passing through the heart and the capacitor accounts for capacitively coupled currents. For can interrupt this control, leading to ventricular fibrillation and in modern insulation material, the insulation resistance is very large, the most severe instances, to death. Thus, the most fundamental so resistive current is typically several orders of magnitude lower requirement of electrical safety is to provide sufficient separation than the capacitively coupled current. The spark gap represents the between the human body and hazardous currents to avoid avalanche (breakdown) phenomenon, where a good insulator turns interrupting the heart’s normal function. bad after a certain voltage is reached. In addition to ventricular fibrillation, the human body may also exhibit When a voltage is applied to an electrical or electronic device, the an involuntary startle reaction and/or muscle contraction in reaction natural capacitance of the insulation charges, resulting in the flow to currents that pass through parts of the body. These reactions of current. If a DC voltage is applied, the charging occurs only when can lead to hazards from the uncontrolled body movements than voltage is first applied. The DC voltage charges the capacitance and can occur when a person is subjected to the unpleasant nerve and the capacitive charging current is then reduced to near zero. muscle stimulation of electric current. Current passing through the body may also cause muscle contractions that make it impossible to For 60 Hz AC voltages, the charging and discharging of this let go of the electrical source. capacitance occurs 60 times each second, so the capacitive charging current remains at a steady-state level and never goes Protecting humans from hazardous currents is typically to zero. This is known as capacitive leakage current. For modern accomplished by preventing contact with any electrical circuits that electronic devices, the resistive leakage current is normally very carry sufficient voltage and current to shock the user. To isolate small, so the overall leakage current of such devices is dominated these circuits from human contact, electrical and electronic devices by the capacitive effect. To protect users from injury, many product employ electrical insulation, the quality of which must be sufficient for safety standards set limits for the allowable leakage current. A typical the working voltage throughout the expected life of the device. The leakage current limit is 0.5mA at 60 Hz and at the rated voltage. dielectric voltage withstand test is performed in order to verify the capability of the insulation. Electrical and electronic devices also exhibit current analogous to leakage current during dielectric testing. However, since the dielectric test voltage is much higher, the current will be higher as well because the capacitive charging current increases in proportion 02 For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
  • 3. Air is the most readily available electrical insulator, and through-air The problem of false failures spacing requirements (also known as “clearance”) are defined in many The use of a trip current setting to determine dielectric breakdown product safety standards in order to maintain voltage separation. is based on the assumption that current above the trip setting is Spacings across the surface of an insulating material are known as indicative of dielectric breakdown. While this is true in many cases, over-surface spacings or “creepage” and are often defined in applicable there are instances in which a current above the trip-out threshold standards. However, even in cases where a device complies with the is not indicative of a breakdown at all. It may actually be reflective of defined through-air and over-surface spacing requirements, the overall the natural dielectric current of the tested device. Thus, the following insulation system must be tested by the application of the dielectric dilemma: trip-out might indicate dielectric breakdown (a failure voltage withstand test to the insulation system. condition) or it might merely indicate dielectric current above the trip- The applied voltage for the dielectric voltage withstand test is usually current setting (not a failure condition). This uncertainty may lead to much higher than the working voltage of the device to accommodate test results deemed unacceptable, when the results actually mask a transient overvoltages, such as voltage surges and switching favorable outcome. (See Figures 2 and 3) transients. This provides a safety margin for production variations and the aging of the material. Trip-out gives a False Failure The objective of the dielectric voltage withstand test is to establish the minimum level of electrical insulation necessary to prevent Improper Trip Current Setting Dielectric Current human contact with a potentially harmful voltage and resulting current. In addition, the dielectric voltage withstand test may reveal faults in mechanically damaged insulation or the presence of a foreign material (such as water) which may bridge the insulation. This test is often used after mechanical abuse or temperature tests to confirm that the product has maintained its insulating capabilities. The dielectric voltage withstand test is also used on the manufacturing production line to identify material and workmanship 120 V 1240 V defects in assembled devices. Applied Voltage Figure 2 Trip current during the dielectric voltage withstand test When dielectric breakdown occurs, the loss of the insulation material’s resistance causes the current to go from a low dielectric current level to a much higher breakdown current. This change in the level of dielectric current has traditionally been monitored by a Trip Current Setting current-sensitive circuit, which trips-out the test equipment when Trip-out Dielectric Current the current exceeds the test equipment’s trip sensitivity setting. indicates This approach has the significant advantages of being simple and breakdown inexpensive and has been used for many years. However, although this method works reasonably well a closer analysis reveals potential limits to its use. Breakdown 120 V 1240 V Figure 3 Applied Voltage 03 For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
  • 4. Because the dielectric test is intended to evaluate the insulation With a DC test, steady-state dielectric current will be much lower system, no limit is specified for dielectric current. Thus, there is no because the product’s capacitance is charged only once. This correct trip-out current setting for determining failure. In practice, occurs at the beginning of the voltage application. If the test voltage the only valid determining criterion for failure is “breakdown.” The is raised slowly, the charging current will be low and, once the test precise value of dielectric current which flows is unimportant; voltage stabilizes, there will be very little current flow. This is an what is important is the sudden, dramatic increase in the dielectric advantage because the trip-out limit of the dielectric tester can be current, indicating that insulation breakdown has occurred. It is for set lower without causing false alarms. this reason that most product safety standards do not specify a trip current threshold for the dielectric test. If the voltage is ramped up too quickly, the capacitive charging current may create false failures. Trip-out during DC voltage ramp-up However, if the expected leakage current is known, then a common must be examined to determine if the cause of the trip-out is normal procedure is to set the trip-out threshold at 20 times the maximum charging current. Repeating the test with a doubled ramp time may leakage current limit. This multiplier includes a factor of 10 for the provide a simple testing solution. approximate ratio of the dielectric test voltage divided by the normal operating voltage, and a factor of 2 for variability. If the current Some products contain electromagnetic interference filters, which exceeds this higher trip-out level, it is likely the result of a dielectric may add capacitance. To accommodate these filters, the leakage failure, and not the expected current flowing in the leakage current current limit in some product safety standards is 3.5 mA. The path from the application of the dielectric test voltage. expected current during a dielectric test might be as high as 3.5 mA times 1240 V / 120V = 36 mA ac rms. With this heavy loading, To summarize, tripping of the dielectric tester only signifies that some dielectric testers are not able to deliver enough voltage across the trip current setting of the tester has been exceeded. Therefore, the terminals to perform the test. However, if a DC test is used, the this result should not be automatically interpreted to mean that capacitive current is just the one-time charging current. Once the breakdown has occurred and further testing or evaluation should capacitance is charged, the dielectric tester requires only a small be conducted. This further evaluation may include several different current load that the tester can easily supply. In the case of high investigative paths, including DC dielectric testing, use of dielectric leakage current limits, replacing the AC test with a DC test may be testers with arc detection, specialized diagnostic testers and necessary, unless the AC dielectric tester has enough capacity to reapplication of the dielectric withstand test voltage to locate the site deliver the test voltage under heavy current load. of the breakdown. There is one disadvantage to DC testing, which becomes evident at the end of the test. Once DC testing has been completed, the inherent AC vs. DC dielectric testing capacitance of the device under test has been fully charged and now The objective of dielectric testing can be met with DC as well as AC poses a potential shock hazard. Accordingly, certain products may voltages. In fact, many product safety standards already include need to be discharged via a short with a bleeder resistor, adding DC voltages in their dielectric test methods. When testing with DC another step and complexity to the DC dielectric test. voltage, the metered voltage must be set for a voltage equal to 1.414 times the AC test voltage, since the AC voltage measurement is an RMS value. The actual peak voltages from the AC wave are 1.414 times the metered AC RMS value. Thus, the DC test voltage is equal to the highest peak AC voltage. 04 For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536
  • 5. Summary The dielectric voltage withstand test can provide important insight into the capabilities and limits of a device’s insulation system. However, it is important to remember that the objective of the test is only to evaluate the insulation’s electrical strength. The current during the dielectric test should not be evaluated against the device’s leakage current limits, since the dielectric test is performed at a much higher voltage. It is common for dielectric test equipment to use a current trip-out limit to indicate dielectric failure. When the tripping device is properly set to allow the expected current to flow through an acceptable dielectric current path, the dielectric test equipment will give trustworthy results. However, in cases where the expected current is not known or the trip-out threshold is selected generically, the trip- out may produce a false failure result. Thus, trip-out by itself should not be assumed to indicate a true dielectric breakdown. An indication of trip-out should always be followed by an investigation into the root cause of the trip-out. Such an investigation will then lead to an invaluable discussion as to the fundamental quality of the device’s electrical insulation system. For additional information about The Dielectric Voltage Withstand Test — Benefits and Limitations white paper, please contact Dale Hallerberg, Research Engineer at Underwriters Laboratories: dale.a.hallerberg@us.ul.com 05 For more information E:: ULUniversity@us.ul.com / T:: 888.503.5536 Copyright © 2010 Underwriters Laboratories Inc. All rights reserved. No part of this document may be copied or distributed without the prior written consent of Underwriters Laboratories Inc.12/10 BDI 100807.8