RECEIVER SIZING:
     In vacuum thermoforming it is customary to generate deep vacuum in a short
     period of time. A vacuum receiver is usually employed to produce this quick
     initial pulldown. If the installation is new, the following formula may be used to
     determine the size of the appropriate vacuum receiver.

V2 = V1(P3-P1)/P2-P3Equ. 1.1

Where: V2 = Applicable vacuum receiver size [Ft3]
       V1 = Total mold volume (forming volume + box volume) [Ft3]
       P1 = Initial pressure in the mold [PSIA]
       P2 = Pressure in vacuum system [PSIA]
       P3 = Pressure in combined system [PSIA]

Example:A vacuum receiver needs to be sized for a new installation. The forming
        volume is 0.8 Ft3, and the box volume is 1.2 Ft3. The initial pressure in the
        mold is 29.75” Hg (barometric pressure). The required pressure to form the
        sheet in the mold is 22” Hg. The pressure produced by the vacuum pump will
        be considered to be a maximum of 28” Hg.


First one must determine what are the appropriate variables, and then covert them to
the appropriate units.

V2 – To be determined
V1 – 2 Ft3 (0.8 Ft3 + 1.2 Ft3)
P1 – 14.61 PSIA (29.76” Hg(A) converted to PSIA)
P2 – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA)
P3 – 3.93 PSIA (22” Hg(G) first converted to 8” Hg(A), then converted to PSIA)

V2 = 2 (3.93 – 14.61)/(0.98-3.93)
V2 = 7.24 Ft3 or times 7.48 gal/1 Ft3;
V2 = 54 gal

In this case, a 60 gal receiver would be appropriate.

Another formula is useful where an existing tank is to be used. If the receiver size is
known, one will wish to calculate the pressure in the combined system.

P3 = (P1V1+P2V2)/(V1+V2) Equ. 1.2

Where: V2 = Existing vacuum receiver size [Ft3]
       V1 = Total mold volume (forming volume + box volume) [Ft3]
       P1 = Initial pressure in the mold [PSIA]
       P2 = Pressure in vacuum system [PSIA]
       P3 = Pressure in combined system [PSIA]


                             Squire-Cogswell/Aeros Instruments Inc
                              1111 Lakeside Drive, Gurnee, Il 60031-4099
                                  800-448-0770 – Fax: 847-855-6300
                                         www.selectorr.com
Example: Say that a 60 gal receiver is available from stock, what will be the final
         pressure in the combined system?

First one must determine what are the appropriate variables, and then convert them to
the appropriate units.

V2 – 8.02 Ft3 (60 gal * 1 Ft3/7.48 gal)
V1 – 2 Ft3 (0.8 Ft3 + 1.2 Ft3)
P1 – 14.61 PSIA (29.75” Hg(G) converted to PSIA)
P2 – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA)
P3 – to be determined

P3 = (14.61 * 2 + 0.98 * 8.02)/(2 + 8.02)
P3 = 3.7 PSIA or converted to “Hg(G) (29.92” Hg(A)-3.7 PSIA (29.92” Hg(A)/14.7 PSIA))
P3 = 22.4” Hg(G)

In most cases the system volume is equivalent to the tank volume. Generally if the
pipework associated with the system is greater than 10% of the tank volume, that the
volume of the pipework should be taken into account. These formulas also do not
account for the collapse of the plastic in the mold. In most cases, the forming volume is
so much smaller than the system volume that it does not add much to the calculations.
These formulas also do not account for leaks in the system.

PUMP SIZING

      After the vacuum receiver has produced the initial quick pulldown, the vacuum
      pump can be used to generate the final deep vacuum. The following formula is
      the general pump down formula.

t = V * LN (PI/PF)/QAVG    Equ. 1.3

Where: t – Time to evacuate volume [min] LN – Natural Log
       V – Total volume to be evacuated [Ft3]
       P1 – Initial pressure (PSIA)
       PF – Final pressure (PSIA)
       QAVG – Average volumetric flowrate of the pump (ACFM)

Note that this formula does not account for leaks in the system

Example:The 60 gal receiver from the previous example has been installed. The
        process requires that the vacuum pump should pull the combined system from
        22.4” Hg to 28” Hg in approximately 10 seconds to increase the detail on the
        molded plastic. Will the SC-6TR be able to accomplish this?

Once again the appropriate variables need to be determined.



                            Squire-Cogswell/Aeros Instruments Inc
                             1111 Lakeside Drive, Gurnee, Il 60031-4099
                                 800-448-0770 – Fax: 847-855-6300
                                        www.selectorr.com
t = To be determined
V – 9.22 Ft3 (1.2 Ft3 = 8.02 Ft3) {note that the forming volume is approximately 0}
P1 – 3.7 PSIA (22.4” Hg(G) determined by equation 1.2)
PF – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA)
QAVG – 37 ACFM
The average flowrate is determined by adding the flows at different vacuum levels. The
average capacity of the pump should be taken between the starting vacuum level and
the ending vacuum level. For this example, the values are for the SC-6TR.

 5” Hg        55 ACFM
19” Hg        47 ACFM
22” Hg        43 ACFM
25” Hg        38 ACFM                   43 + 38 + 31
28” Hg        31 ACFM                        3       = 37.33 or 37 Avg. ACFM
29” Hg        21 ACFM

Solving for time:

t = 9.22 * LN (3.8/0.98)/37
t = 0.331 min or times 60 s/1 min;
t = 20 s

Basically the SC-6TR will take 10 seconds too long to accomplish this pulldown. Try the
SC-10TR using the same parameters. All of the values remain the same, except for the
average flowrate of the pump For the SC-10TR from 22” Hg to 28” Hg:

QAVG = 82 ACFM

Once again solving for time:

t = 9.22 * :N (3.8/0/98)/82
t = 0.149 min or times 60 s/1 min;
t=9s

In answer to the question that was posed in the example, the SC-6TR will not be able to
satisfy the requirement, but the SC-10TR does satisfy the requirement.

Another way to work this problem is to determine what flowrate is required given a
specific time period.

Example:The 60 gal receiver from the previous example has been installed. The
        process requires that the vacuum pump should pull the combined system from
        22.4” Hg to 28 Hg in approximately 10 seconds to increase the detail on the
        molded plastic. Will the SC-6TR be able to accomplish this?


                               Squire-Cogswell/Aeros Instruments Inc
                               1111 Lakeside Drive, Gurnee, Il 60031-4099
                                   800-448-0770 – Fax: 847-855-6300
                                          www.selectorr.com
Change the formula to the following format:

QAVG = V * LN (PI/PF)/t    Equ. 1.4

From the values that been used in the previous pump down examples:

QAVG = 9.22 * LN (3.7/0.98)/0.1667
 {t = 10 s * (1 min/60 s) = 0.1667 min}
QAVG = 73 ACFM

From what has been shown here, knowing the average volumetric flowrates, is that the
SC-10TR will be the best choice.




Converting from SCFM to ACFM is as follows:

V2 = V1(P1/P2)(T2/T1)               Equ. 1.5

Where:V2 – ACFM            P1 – Absolute Pressure @ STP
     V1 – SCFM             P2 – Absolute Pressure @ Vacuum Condition
                           T1 – Absolute Temperature @ STP
                           T2 – Absolute Temperature @ Vacuum Condition
                           MW – Average Molecular Weight

                           STP (Standard Temperature and Pressure)
                           is 520oR and 760 mmHg(A)

An easy way to remember is:
      V that you want = V that you have x
      (P that you have / P that you want) x
      (T that you want / T that you have)

Converting from a mass flowrate to a volumetric flowrate is as follows:

V = m (1/60)(379/MW)(P1/P2)(T2/T1)                    Equ. 1.6




                            Squire-Cogswell/Aeros Instruments Inc
                             1111 Lakeside Drive, Gurnee, Il 60031-4099
                                 800-448-0770 – Fax: 847-855-6300
                                        www.selectorr.com
Where:V – ACFM             P1 – Absolute Pressure @ STP
     m - #/Hr              P2 – Absolute Pressure @ Vacuum Condition
                           T1 – Absolute Temperature @ STP
                           T2 – Absolute Temperature @ Vacuum Condition
                           MW – Average Molecular Weight

                           STP (Standard Temperature and Pressure)
                           is 520oR and 760 mmHg(A)

Example:
Convert 20#/Hr of air to volumetric flowrate 25” Hg and 100oF.

V = m (1/60)(379/MW)(P1/P2)(T2/T1)
m = 20#/Hr
P1 = 760 mmHg(A) = 29.92” Hg(A)
P2 = 25” Hg(G) = 125 mmHg(A), or 4.92” Hg(A)
T1 = 460 + 60oF = 520oR
T2 = 460 + 100oF = 560oR

V = 20 (1/60)(379/29)(760/125)(560/520), or V = 20
(1/60)(379/29)(29.92/4.92)(560/520)
V = 29 ACFM @ 25” Hg and 100oF (Volumetric flowrates should be described at a
       specific pressure and temperature

Converting from a volumetric flowrate to a mass flowrate is as follows:

M = V (60/1)(MW/379)(P2/P1)(T1/T2),
using the same symbols as above.                      Equ. 1.7

Example:

Convert 300 ACFM of air @ 28.5 Hg and 60oF to a mass flowrate.

m = V (60/1)(MW/379)(P2/P1)(T1/T2)
V = 300 ACFM
P1 = 760 mm Hg = 29.92” Hg
P2 = 28.5” Hg = 36 mmHg, or 1.42” Hg(A)
T1 = 460 + 60oF = 520oR
T2 = 460 + 100oF = 520oF, note that since T1 = T2, the division is 1, and it may be
neglected

m = 300 (60/1)(29/379)(36/760), or m = 300 (60/1)(29/379)(1.42/29.92)
m = 65#/Hr

Note that all calculations involving pressure and temperature should be performed at
absolute conditions.


                            Squire-Cogswell/Aeros Instruments Inc
                             1111 Lakeside Drive, Gurnee, Il 60031-4099
                                 800-448-0770 – Fax: 847-855-6300
                                        www.selectorr.com

Weitere ähnliche Inhalte

Was ist angesagt?

Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Pradeep Dhondi
 
Full report gas absorption
Full report gas  absorptionFull report gas  absorption
Full report gas absorptionErra Zulkifli
 
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage TanksDesign Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage TanksKushagra Saxena
 
Pump api 675 presentation
Pump api 675 presentationPump api 675 presentation
Pump api 675 presentationVothanh Trung
 
Shell and tube heat exchanger design
Shell and tube heat exchanger designShell and tube heat exchanger design
Shell and tube heat exchanger designhossie
 
Absorption Column: Foundations, Applications and Scientific Progress
Absorption Column: Foundations, Applications and Scientific ProgressAbsorption Column: Foundations, Applications and Scientific Progress
Absorption Column: Foundations, Applications and Scientific ProgressAngel Darío González-Delgado
 
Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Vijay Sarathy
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1Om Pratap Singh
 
Cooling towers
Cooling towersCooling towers
Cooling towersctlin5
 
Steam Header Design in Fluid (Steam) System
Steam Header Design in Fluid (Steam) SystemSteam Header Design in Fluid (Steam) System
Steam Header Design in Fluid (Steam) SystemAditya Deshpande
 
Agitator design and selection
Agitator design and selectionAgitator design and selection
Agitator design and selectionvshroff
 
Design of-absorption-column
Design of-absorption-columnDesign of-absorption-column
Design of-absorption-columnAli Hassan
 
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...Vijay Sarathy
 
Shell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat TransferShell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat TransferUsman Shah
 
Design of packed columns
Design of packed columnsDesign of packed columns
Design of packed columnsalsyourih
 

Was ist angesagt? (20)

Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
 
Full report gas absorption
Full report gas  absorptionFull report gas  absorption
Full report gas absorption
 
Understanding the Nutsche Filtration and Drying Process
Understanding the Nutsche Filtration and Drying ProcessUnderstanding the Nutsche Filtration and Drying Process
Understanding the Nutsche Filtration and Drying Process
 
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage TanksDesign Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
 
Tray vs packed column
Tray  vs packed columnTray  vs packed column
Tray vs packed column
 
Pump api 675 presentation
Pump api 675 presentationPump api 675 presentation
Pump api 675 presentation
 
Shell and tube heat exchanger design
Shell and tube heat exchanger designShell and tube heat exchanger design
Shell and tube heat exchanger design
 
Absorption Column: Foundations, Applications and Scientific Progress
Absorption Column: Foundations, Applications and Scientific ProgressAbsorption Column: Foundations, Applications and Scientific Progress
Absorption Column: Foundations, Applications and Scientific Progress
 
Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1
 
Cooling towers
Cooling towersCooling towers
Cooling towers
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Steam Header Design in Fluid (Steam) System
Steam Header Design in Fluid (Steam) SystemSteam Header Design in Fluid (Steam) System
Steam Header Design in Fluid (Steam) System
 
Agitator design and selection
Agitator design and selectionAgitator design and selection
Agitator design and selection
 
Air sepration
Air seprationAir sepration
Air sepration
 
Design of-absorption-column
Design of-absorption-columnDesign of-absorption-column
Design of-absorption-column
 
Boiler Presentation
Boiler PresentationBoiler Presentation
Boiler Presentation
 
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...
A QUICK ESTIMATION METHOD TO DETERMINE HOT RECYCLE REQUIREMENTS FOR CENTRIFUG...
 
Shell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat TransferShell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat Transfer
 
Design of packed columns
Design of packed columnsDesign of packed columns
Design of packed columns
 

Andere mochten auch

Determination of vacuum pump operational efficiency
Determination of vacuum pump operational efficiencyDetermination of vacuum pump operational efficiency
Determination of vacuum pump operational efficiencyDevesh Singhal
 
Vacuum pumps their types and uses
Vacuum pumps their types and usesVacuum pumps their types and uses
Vacuum pumps their types and usesShang Thomas
 
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...Gulfam Raza
 

Andere mochten auch (9)

Determination of vacuum pump operational efficiency
Determination of vacuum pump operational efficiencyDetermination of vacuum pump operational efficiency
Determination of vacuum pump operational efficiency
 
Intro To Vacuum Systems
Intro To Vacuum SystemsIntro To Vacuum Systems
Intro To Vacuum Systems
 
Root blower
Root blowerRoot blower
Root blower
 
Vacuum pump
Vacuum pumpVacuum pump
Vacuum pump
 
Types of vacuum pump
Types of vacuum pumpTypes of vacuum pump
Types of vacuum pump
 
Vacuum pumps their types and uses
Vacuum pumps their types and usesVacuum pumps their types and uses
Vacuum pumps their types and uses
 
Vacuum system
Vacuum systemVacuum system
Vacuum system
 
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...
Principle & Applications of Transmission Electron Microscopy (TEM) & High Res...
 
Sem n tem
Sem n temSem n tem
Sem n tem
 

Ähnlich wie Vacuum pump-sizing

CondensateFeedwaterSystem Part1.ppt
CondensateFeedwaterSystem Part1.pptCondensateFeedwaterSystem Part1.ppt
CondensateFeedwaterSystem Part1.pptArslanAbbas36
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)Yuri Melliza
 
2. Fluids 2.ppt
2. Fluids 2.ppt2. Fluids 2.ppt
2. Fluids 2.pptBlahBeleh
 
volumetric properties.ppt
volumetric properties.pptvolumetric properties.ppt
volumetric properties.pptIyerVasundhara
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)Yuri Melliza
 
LECTURE Notes on compressor
LECTURE Notes on compressorLECTURE Notes on compressor
LECTURE Notes on compressorYuri Melliza
 
Design of transonic axial compressor
Design of transonic axial compressorDesign of transonic axial compressor
Design of transonic axial compressorSai Goud
 
Thermodynamic Chapter 5 Air Standard Cycle
Thermodynamic Chapter 5 Air Standard CycleThermodynamic Chapter 5 Air Standard Cycle
Thermodynamic Chapter 5 Air Standard CycleMuhammad Surahman
 
fanmodule-230428052900-38a217b0.pdf
fanmodule-230428052900-38a217b0.pdffanmodule-230428052900-38a217b0.pdf
fanmodule-230428052900-38a217b0.pdfBlentBulut5
 
Principle of turbomachinery
Principle of turbomachineryPrinciple of turbomachinery
Principle of turbomachineryWalid Mohammed
 
Vapor Combustor Improvement Project LinkedIn Presentation February 2016
Vapor Combustor Improvement Project LinkedIn Presentation February 2016Vapor Combustor Improvement Project LinkedIn Presentation February 2016
Vapor Combustor Improvement Project LinkedIn Presentation February 2016Tim Krimmel, MEM
 
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...IRJET Journal
 
Boiler doc 04 flowmetering
Boiler doc 04   flowmeteringBoiler doc 04   flowmetering
Boiler doc 04 flowmeteringMars Tsani
 

Ähnlich wie Vacuum pump-sizing (20)

CondensateFeedwaterSystem Part1.ppt
CondensateFeedwaterSystem Part1.pptCondensateFeedwaterSystem Part1.ppt
CondensateFeedwaterSystem Part1.ppt
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)
 
2. Fluids 2.ppt
2. Fluids 2.ppt2. Fluids 2.ppt
2. Fluids 2.ppt
 
volumetric properties.ppt
volumetric properties.pptvolumetric properties.ppt
volumetric properties.ppt
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)
 
Thermo 5th chap05_p001
Thermo 5th chap05_p001Thermo 5th chap05_p001
Thermo 5th chap05_p001
 
LECTURE Notes on compressor
LECTURE Notes on compressorLECTURE Notes on compressor
LECTURE Notes on compressor
 
4.8.compressors
4.8.compressors4.8.compressors
4.8.compressors
 
4.8.compressors
4.8.compressors4.8.compressors
4.8.compressors
 
Design of transonic axial compressor
Design of transonic axial compressorDesign of transonic axial compressor
Design of transonic axial compressor
 
Thermodynamic Chapter 5 Air Standard Cycle
Thermodynamic Chapter 5 Air Standard CycleThermodynamic Chapter 5 Air Standard Cycle
Thermodynamic Chapter 5 Air Standard Cycle
 
fanmodule-230428052900-38a217b0.pdf
fanmodule-230428052900-38a217b0.pdffanmodule-230428052900-38a217b0.pdf
fanmodule-230428052900-38a217b0.pdf
 
FAN MODULE.pdf
FAN MODULE.pdfFAN MODULE.pdf
FAN MODULE.pdf
 
Principle of turbomachinery
Principle of turbomachineryPrinciple of turbomachinery
Principle of turbomachinery
 
Pipeline b
Pipeline bPipeline b
Pipeline b
 
MEM 540 Midterm
MEM 540 MidtermMEM 540 Midterm
MEM 540 Midterm
 
exp.9 flow meter demonstration
exp.9 flow meter demonstrationexp.9 flow meter demonstration
exp.9 flow meter demonstration
 
Vapor Combustor Improvement Project LinkedIn Presentation February 2016
Vapor Combustor Improvement Project LinkedIn Presentation February 2016Vapor Combustor Improvement Project LinkedIn Presentation February 2016
Vapor Combustor Improvement Project LinkedIn Presentation February 2016
 
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...
Improving Gas Turbine – HRSG output using Inlet Air Chilling and Converted Ev...
 
Boiler doc 04 flowmetering
Boiler doc 04   flowmeteringBoiler doc 04   flowmetering
Boiler doc 04 flowmetering
 

Vacuum pump-sizing

  • 1. RECEIVER SIZING: In vacuum thermoforming it is customary to generate deep vacuum in a short period of time. A vacuum receiver is usually employed to produce this quick initial pulldown. If the installation is new, the following formula may be used to determine the size of the appropriate vacuum receiver. V2 = V1(P3-P1)/P2-P3Equ. 1.1 Where: V2 = Applicable vacuum receiver size [Ft3] V1 = Total mold volume (forming volume + box volume) [Ft3] P1 = Initial pressure in the mold [PSIA] P2 = Pressure in vacuum system [PSIA] P3 = Pressure in combined system [PSIA] Example:A vacuum receiver needs to be sized for a new installation. The forming volume is 0.8 Ft3, and the box volume is 1.2 Ft3. The initial pressure in the mold is 29.75” Hg (barometric pressure). The required pressure to form the sheet in the mold is 22” Hg. The pressure produced by the vacuum pump will be considered to be a maximum of 28” Hg. First one must determine what are the appropriate variables, and then covert them to the appropriate units. V2 – To be determined V1 – 2 Ft3 (0.8 Ft3 + 1.2 Ft3) P1 – 14.61 PSIA (29.76” Hg(A) converted to PSIA) P2 – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA) P3 – 3.93 PSIA (22” Hg(G) first converted to 8” Hg(A), then converted to PSIA) V2 = 2 (3.93 – 14.61)/(0.98-3.93) V2 = 7.24 Ft3 or times 7.48 gal/1 Ft3; V2 = 54 gal In this case, a 60 gal receiver would be appropriate. Another formula is useful where an existing tank is to be used. If the receiver size is known, one will wish to calculate the pressure in the combined system. P3 = (P1V1+P2V2)/(V1+V2) Equ. 1.2 Where: V2 = Existing vacuum receiver size [Ft3] V1 = Total mold volume (forming volume + box volume) [Ft3] P1 = Initial pressure in the mold [PSIA] P2 = Pressure in vacuum system [PSIA] P3 = Pressure in combined system [PSIA] Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive, Gurnee, Il 60031-4099 800-448-0770 – Fax: 847-855-6300 www.selectorr.com
  • 2. Example: Say that a 60 gal receiver is available from stock, what will be the final pressure in the combined system? First one must determine what are the appropriate variables, and then convert them to the appropriate units. V2 – 8.02 Ft3 (60 gal * 1 Ft3/7.48 gal) V1 – 2 Ft3 (0.8 Ft3 + 1.2 Ft3) P1 – 14.61 PSIA (29.75” Hg(G) converted to PSIA) P2 – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA) P3 – to be determined P3 = (14.61 * 2 + 0.98 * 8.02)/(2 + 8.02) P3 = 3.7 PSIA or converted to “Hg(G) (29.92” Hg(A)-3.7 PSIA (29.92” Hg(A)/14.7 PSIA)) P3 = 22.4” Hg(G) In most cases the system volume is equivalent to the tank volume. Generally if the pipework associated with the system is greater than 10% of the tank volume, that the volume of the pipework should be taken into account. These formulas also do not account for the collapse of the plastic in the mold. In most cases, the forming volume is so much smaller than the system volume that it does not add much to the calculations. These formulas also do not account for leaks in the system. PUMP SIZING After the vacuum receiver has produced the initial quick pulldown, the vacuum pump can be used to generate the final deep vacuum. The following formula is the general pump down formula. t = V * LN (PI/PF)/QAVG Equ. 1.3 Where: t – Time to evacuate volume [min] LN – Natural Log V – Total volume to be evacuated [Ft3] P1 – Initial pressure (PSIA) PF – Final pressure (PSIA) QAVG – Average volumetric flowrate of the pump (ACFM) Note that this formula does not account for leaks in the system Example:The 60 gal receiver from the previous example has been installed. The process requires that the vacuum pump should pull the combined system from 22.4” Hg to 28” Hg in approximately 10 seconds to increase the detail on the molded plastic. Will the SC-6TR be able to accomplish this? Once again the appropriate variables need to be determined. Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive, Gurnee, Il 60031-4099 800-448-0770 – Fax: 847-855-6300 www.selectorr.com
  • 3. t = To be determined V – 9.22 Ft3 (1.2 Ft3 = 8.02 Ft3) {note that the forming volume is approximately 0} P1 – 3.7 PSIA (22.4” Hg(G) determined by equation 1.2) PF – 0.98 PSIA (28” Hg(G) first converted to 2” Hg(A), then converted to PSIA) QAVG – 37 ACFM The average flowrate is determined by adding the flows at different vacuum levels. The average capacity of the pump should be taken between the starting vacuum level and the ending vacuum level. For this example, the values are for the SC-6TR. 5” Hg 55 ACFM 19” Hg 47 ACFM 22” Hg 43 ACFM 25” Hg 38 ACFM 43 + 38 + 31 28” Hg 31 ACFM 3 = 37.33 or 37 Avg. ACFM 29” Hg 21 ACFM Solving for time: t = 9.22 * LN (3.8/0.98)/37 t = 0.331 min or times 60 s/1 min; t = 20 s Basically the SC-6TR will take 10 seconds too long to accomplish this pulldown. Try the SC-10TR using the same parameters. All of the values remain the same, except for the average flowrate of the pump For the SC-10TR from 22” Hg to 28” Hg: QAVG = 82 ACFM Once again solving for time: t = 9.22 * :N (3.8/0/98)/82 t = 0.149 min or times 60 s/1 min; t=9s In answer to the question that was posed in the example, the SC-6TR will not be able to satisfy the requirement, but the SC-10TR does satisfy the requirement. Another way to work this problem is to determine what flowrate is required given a specific time period. Example:The 60 gal receiver from the previous example has been installed. The process requires that the vacuum pump should pull the combined system from 22.4” Hg to 28 Hg in approximately 10 seconds to increase the detail on the molded plastic. Will the SC-6TR be able to accomplish this? Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive, Gurnee, Il 60031-4099 800-448-0770 – Fax: 847-855-6300 www.selectorr.com
  • 4. Change the formula to the following format: QAVG = V * LN (PI/PF)/t Equ. 1.4 From the values that been used in the previous pump down examples: QAVG = 9.22 * LN (3.7/0.98)/0.1667 {t = 10 s * (1 min/60 s) = 0.1667 min} QAVG = 73 ACFM From what has been shown here, knowing the average volumetric flowrates, is that the SC-10TR will be the best choice. Converting from SCFM to ACFM is as follows: V2 = V1(P1/P2)(T2/T1) Equ. 1.5 Where:V2 – ACFM P1 – Absolute Pressure @ STP V1 – SCFM P2 – Absolute Pressure @ Vacuum Condition T1 – Absolute Temperature @ STP T2 – Absolute Temperature @ Vacuum Condition MW – Average Molecular Weight STP (Standard Temperature and Pressure) is 520oR and 760 mmHg(A) An easy way to remember is: V that you want = V that you have x (P that you have / P that you want) x (T that you want / T that you have) Converting from a mass flowrate to a volumetric flowrate is as follows: V = m (1/60)(379/MW)(P1/P2)(T2/T1) Equ. 1.6 Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive, Gurnee, Il 60031-4099 800-448-0770 – Fax: 847-855-6300 www.selectorr.com
  • 5. Where:V – ACFM P1 – Absolute Pressure @ STP m - #/Hr P2 – Absolute Pressure @ Vacuum Condition T1 – Absolute Temperature @ STP T2 – Absolute Temperature @ Vacuum Condition MW – Average Molecular Weight STP (Standard Temperature and Pressure) is 520oR and 760 mmHg(A) Example: Convert 20#/Hr of air to volumetric flowrate 25” Hg and 100oF. V = m (1/60)(379/MW)(P1/P2)(T2/T1) m = 20#/Hr P1 = 760 mmHg(A) = 29.92” Hg(A) P2 = 25” Hg(G) = 125 mmHg(A), or 4.92” Hg(A) T1 = 460 + 60oF = 520oR T2 = 460 + 100oF = 560oR V = 20 (1/60)(379/29)(760/125)(560/520), or V = 20 (1/60)(379/29)(29.92/4.92)(560/520) V = 29 ACFM @ 25” Hg and 100oF (Volumetric flowrates should be described at a specific pressure and temperature Converting from a volumetric flowrate to a mass flowrate is as follows: M = V (60/1)(MW/379)(P2/P1)(T1/T2), using the same symbols as above. Equ. 1.7 Example: Convert 300 ACFM of air @ 28.5 Hg and 60oF to a mass flowrate. m = V (60/1)(MW/379)(P2/P1)(T1/T2) V = 300 ACFM P1 = 760 mm Hg = 29.92” Hg P2 = 28.5” Hg = 36 mmHg, or 1.42” Hg(A) T1 = 460 + 60oF = 520oR T2 = 460 + 100oF = 520oF, note that since T1 = T2, the division is 1, and it may be neglected m = 300 (60/1)(29/379)(36/760), or m = 300 (60/1)(29/379)(1.42/29.92) m = 65#/Hr Note that all calculations involving pressure and temperature should be performed at absolute conditions. Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive, Gurnee, Il 60031-4099 800-448-0770 – Fax: 847-855-6300 www.selectorr.com