POWER QUALITY ANALYSIS:
 PROBLEMS & SOLUTIONS


       PARTHAVI PADHY
     ROLL NUMBER-0901106012
       ELECTRICAL ENGG.
INTRODUCTION
   Power Quality means quality of the normal voltage
    supplied to your facility.
   The growing use of microprocessors and electronic
    equipments has made us to focus on power quality .
   Equipment and machinery can be damaged or even fail
    when subjected to power anomalies .
   Voltage provided should be as close as possible to
    nominal voltage and waveform must be pure sine wave
    free from any harmonics and other disturbances.
POWER QUALITY PROBLEMS:
  Power Quality problems can be broadly
  classified into following categories.
• Voltage sags
• Micro-interruptions
• Long interruptions
• Voltage spikes
• Voltage swells
• Harmonic distortion
Voltage Sags
A decrease of the normal voltage level between 10 and 90% of the nominal
rms voltage at the power frequency, for durations of 0,5 cycle to 1 minute.
Causes:
• Faults on the transmission or distribution
network.
• Faults in consumer’s installation.
• Connection of heavy loads and start-up of
large motors.
Consequences:
• Malfunction of microprocessor-based
control systems that may lead to a process
stoppage.
•Disconnection and loss of efficiency in
electric rotating machines.
Micro-Interruptions
Total interruption of electrical supply for duration from few milliseconds
to one or two seconds.
Causes:
• Opening and automatic reclosure of protection devices.
• Insulation failure, lightning and insulator flashover.
Consequences:
  •Tripping of protection devices.
  • Loss of information and malfunction of data processing equipment.
  • Stoppage of sensitive equipment (such as ASDs, PCs, PLCs).
Long Interruptions
   Total interruption of electrical supply for duration greater than 1 to 2 seconds.




     Causes:
       • Equipment failure in the power system network.
       • Storms and objects (trees, cars, etc) striking lines or poles, fire.
       • Human error, bad coordination or failure of protection devices.
     Consequences:
       • Stoppage of all equipment.
Voltage Spikes
Very fast variation of the voltage value for durations from a several
 microseconds to few milliseconds.

                                    Causes:
                                      • Lightning.
                                      • Switching of lines or power
                                         factor correction capacitors.
                                      • Disconnection of heavy loads.

                                    Consequences:
                                      • Destruction of components
                                        and of insulation materials.
                                      • Data processing errors or data loss.
                                      • Electromagnetic interference.
Voltage Swells
Momentary increase of the voltage, at the power frequency, outside the
normal tolerances, with duration of more than one cycle and typically less
than a few seconds.

Causes:
  • Start/stop of heavy loads.
  • Poorly dimensioned power sources.
  • Poorly regulated transformers.

Consequences:
  • Flickering of lighting and screens.
  • Damage or stoppage or damage of
    sensitive equipment.
Harmonic Distortion
Voltage or current waveforms assume non-sinusoidal shape. The
waveform corresponds to the sum of different sine-waves with
different magnitude and phase, having frequencies that are multiples
of power-system frequency.


Causes:
Classic sources:
  electric machines working above the knee of the
magnetization curve (magnetic saturation), arc
furnaces, welding machines, rectifiers, and DC brush
motors.
Modern sources:
   all non-linear loads, such as power   electronics
equipment including ASDs, switched mode power
supplies, data processing equipment, high efficiency
lighting.
Consequences of harmonic distortion
• Increased   probability of occurrence of resonance.

• Nuisance tripping of thermal protections.

• Electromagnetic interference.

• Increase in the losses.

• Loss of efficiency in electric machines (e.g. 5th harmonic).
SolutionS for PQ ProblemS
Grid Adequacy


Many PQ problems have origin in T& D network.

A proper planned and maintained grid will avoid
many PQ problems.

- High level of redundancy;
- Cleaning of insulators;
- Trimming of trees nearby power lines…
Distributed Resources

1.Distributed Generation (DG)

2.Energy Storage (restoring technologies)
• Flywheels
• Supercapacitors
• SMES
Distributed Generation
•Used to provide “clean power” to critical loads, isolating them from
disturbances with origin in the grid.
• Backup generators to assure energy supply to critical loads during sustained
outages.
•The most common solution is the combination of electrochemical batteries UPS
and a diesel genset. At present, the integration of a flywheel and a diesel genset in a
single unit is also becoming a popular solution, offered by many manufacturers.
Distributed Resources – Energy Storage
                   Systems
Restoring technologies
. Energy storage systems, also known as restoring
technologies, are used to provide the electric loads with
ride-through capability in poor PQ environment.
Flywheels
Electromechanical device that couples a rotating electric machine
(motor/generator) with a rotating mass to store energy for short
durations.
Super capacitors
New technology applied to capacitors
  • High power density
  • Long life and non-toxic
Superconducting Magnetic Energy
                Storage (SMES)
Energy is stored in the magnetic field of a coil made of superconductor
material.
  • High power density
  • Very fast response
  • Very expensive (on development)
Codes and Standards
Need to regulate:
 • the minimum PQ level that utilities have to provide to consumers, and
 • the immunity level that equipment should have.

Most relevant standards:
 • CBEMA curve
 • ITIC curve
 • IEC 61000
 • EN 50160:2001
 • IEEE standards
    - 519-1992 →Harmonics
    - 1100-1992 →Powering and grounding sensitive equipment
    - 1159-1992 →Monitoring power quality
    - 1250-1995 →Service of sensitive equipment
CBEMA curve.




 ITIC curve
Enhanced Interface Devices
•Using proper interface devices, one can isolate the loads from disturbances deriving from
the grid. Some of the enhanced interface devices are:

   A. Dynamic Voltage Restorer
A dynamic voltage restorer (DVR) acts like a voltage source connected in series with the
load. The output voltage of the DVR is kept approximately constant voltage at the load
terminals.

   B. Transient Voltage Surge suppressors (TVSS)
Transient voltage surge suppressors are used as interface between the power source and
sensitive loads, so that the transient voltage is clamped by the TVSS before it reaches the
load.
    C. Noise Filters
  Noise filters are used to avoid unwanted frequency current or voltage signals (noise) from
  reaching sensitive equipment.
   D. Static VAR Compensators
 Static VAR compensators (SVR) use a combination of capacitors and reactors to
regulate the voltage quickly.
E. Harmonic Filters
Harmonic filters are used to reduce undesirable harmonics. They can be divided in
two groups:
• passive filters
• active filters.

Passive filters (left) consist in a low impedance path to the frequencies of the
harmonics to be attenuated using passive components (inductors, capacitors and
resistors).
Active filters (right) analyse the current consumed by the load and create a
current that cancel the harmonic current generated by the loads.
Make End-use Devices Less
                Sensitive
• In most cases, making the end-use devices less sensitive to PQ
  disturbances is more cost effective than buying equipment to
    mitigate these problems.

• Some measures to increase equipment immunity:
   – Add a capacitor with larger capacity to power supplies;
   – Use cables with larger neutral conductors;
   – Derate transformers;
Conclusions
The availability of electric power with high quality is crucial for the
   running of the modern society. If some sectors are satisfied with the
   quality of the power provided by utilities, some others are more
   demanding.
To avoid the huge losses related to PQ problems, the most demanding
   consumers must take action to prevent the problems. Among the
   various measures, selection of less sensitive equipment can play an
   important role. When even the most robust equipment is affected, then
   other measures must be taken, such as installation of restoring
   technologies, distributed generation or an interface device to avoid PQ
   problems.
Power quality

Weitere ähnliche Inhalte

Was ist angesagt?

Harmonics and mitigation techniques
Harmonics and mitigation techniquesHarmonics and mitigation techniques
Harmonics and mitigation techniquesrifat maryum
 
Switchgear and protection 1
Switchgear and protection 1Switchgear and protection 1
Switchgear and protection 1Md Irshad Ahmad
 
Power Quality and Monitoring
Power Quality and MonitoringPower Quality and Monitoring
Power Quality and Monitoringash08031996
 
Ppt of ehv ac transmission
Ppt of ehv ac transmissionPpt of ehv ac transmission
Ppt of ehv ac transmissionSumit Kumar
 
Economic operation of power system
Economic operation of power systemEconomic operation of power system
Economic operation of power systemBalaram Das
 
Multi terminal dc systems (mtdc)
Multi terminal dc systems (mtdc)Multi terminal dc systems (mtdc)
Multi terminal dc systems (mtdc)jawaharramaya
 
single phase energy meter.pptx
single phase energy meter.pptxsingle phase energy meter.pptx
single phase energy meter.pptxtadi1padma
 
Inter Connected Power System(Turbine Speed Governing Mechanism )
Inter Connected Power System(Turbine Speed Governing Mechanism)Inter Connected Power System(Turbine Speed Governing Mechanism)
Inter Connected Power System(Turbine Speed Governing Mechanism )Raviraj solanki
 
Protection & switchgear
Protection & switchgear   Protection & switchgear
Protection & switchgear johny renoald
 
static series synchronus compensator
static series synchronus compensatorstatic series synchronus compensator
static series synchronus compensatorbhupendra kumar
 
Basic types of facts controllers
Basic types of facts controllersBasic types of facts controllers
Basic types of facts controllersAyyarao T S L V
 
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)Rohit vijay
 
POWER SYSTEM PROTECTION
POWER SYSTEM PROTECTION POWER SYSTEM PROTECTION
POWER SYSTEM PROTECTION moiz89
 
Protection and control of Microgrid
Protection and control of MicrogridProtection and control of Microgrid
Protection and control of MicrogridAmarjeet S Pandey
 

Was ist angesagt? (20)

Facts lectures-2014
Facts lectures-2014Facts lectures-2014
Facts lectures-2014
 
HVDC & FACTS
HVDC & FACTSHVDC & FACTS
HVDC & FACTS
 
Harmonics and mitigation techniques
Harmonics and mitigation techniquesHarmonics and mitigation techniques
Harmonics and mitigation techniques
 
Switchgear and protection 1
Switchgear and protection 1Switchgear and protection 1
Switchgear and protection 1
 
Harmonics
HarmonicsHarmonics
Harmonics
 
Power Quality and Monitoring
Power Quality and MonitoringPower Quality and Monitoring
Power Quality and Monitoring
 
Ppt of ehv ac transmission
Ppt of ehv ac transmissionPpt of ehv ac transmission
Ppt of ehv ac transmission
 
Economic operation of power system
Economic operation of power systemEconomic operation of power system
Economic operation of power system
 
Static relay
Static relayStatic relay
Static relay
 
Multi terminal dc systems (mtdc)
Multi terminal dc systems (mtdc)Multi terminal dc systems (mtdc)
Multi terminal dc systems (mtdc)
 
single phase energy meter.pptx
single phase energy meter.pptxsingle phase energy meter.pptx
single phase energy meter.pptx
 
Inter Connected Power System(Turbine Speed Governing Mechanism )
Inter Connected Power System(Turbine Speed Governing Mechanism)Inter Connected Power System(Turbine Speed Governing Mechanism)
Inter Connected Power System(Turbine Speed Governing Mechanism )
 
Protection & switchgear
Protection & switchgear   Protection & switchgear
Protection & switchgear
 
FAULT ANALISIS IN HVDC & HVAC TRANSMISSION LINE
FAULT ANALISIS IN HVDC & HVAC TRANSMISSION LINEFAULT ANALISIS IN HVDC & HVAC TRANSMISSION LINE
FAULT ANALISIS IN HVDC & HVAC TRANSMISSION LINE
 
static series synchronus compensator
static series synchronus compensatorstatic series synchronus compensator
static series synchronus compensator
 
Basic types of facts controllers
Basic types of facts controllersBasic types of facts controllers
Basic types of facts controllers
 
Reactive power compensation
Reactive power compensationReactive power compensation
Reactive power compensation
 
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)
POWER QUALITY ISSUES (POWER SYSTEM AND POWER ELECTRONICS)
 
POWER SYSTEM PROTECTION
POWER SYSTEM PROTECTION POWER SYSTEM PROTECTION
POWER SYSTEM PROTECTION
 
Protection and control of Microgrid
Protection and control of MicrogridProtection and control of Microgrid
Protection and control of Microgrid
 

Andere mochten auch

Power quality-disturbances and monitoring Seminar
Power quality-disturbances and monitoring  SeminarPower quality-disturbances and monitoring  Seminar
Power quality-disturbances and monitoring SeminarSurabhi Vasudev
 
Introduction to Power Quality
Introduction to Power QualityIntroduction to Power Quality
Introduction to Power QualitySteve Johnson
 
Power Quality Issues _Literature Survey
Power Quality Issues _Literature SurveyPower Quality Issues _Literature Survey
Power Quality Issues _Literature SurveyKetan Bhavsar
 
seminar report on power quality monitoring
seminar report on power quality monitoring  seminar report on power quality monitoring
seminar report on power quality monitoring khemraj298
 
Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Kinnera Kin
 
Overview of power quality problems ppt
Overview of power quality problems pptOverview of power quality problems ppt
Overview of power quality problems pptMitesh Karmur
 
Power Quality Issues
Power Quality IssuesPower Quality Issues
Power Quality Issuesmaneesh001
 
Power quality issues in POWER SYSTEMS
Power quality issues in POWER SYSTEMSPower quality issues in POWER SYSTEMS
Power quality issues in POWER SYSTEMSCharan Sai Jc
 
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRM
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRMPOWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRM
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRMRavijesh Kumar
 
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...Practical Power System Harmonics, Earthing and Power Quality - Problems and S...
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...Living Online
 
Reactive power consumption in modern power system
Reactive power consumption in modern power systemReactive power consumption in modern power system
Reactive power consumption in modern power systemRahuldey1991
 
Voltage sag
Voltage sagVoltage sag
Voltage sagAJAL A J
 
Ajal UPQC
Ajal UPQC Ajal UPQC
Ajal UPQC AJAL A J
 
Harmonics in power system
Harmonics in power systemHarmonics in power system
Harmonics in power systemMinh Anh Nguyen
 
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMPOWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMpechetti surya venkata subrahmanyam
 

Andere mochten auch (20)

Power quality.ppt
Power quality.pptPower quality.ppt
Power quality.ppt
 
Power quality-disturbances and monitoring Seminar
Power quality-disturbances and monitoring  SeminarPower quality-disturbances and monitoring  Seminar
Power quality-disturbances and monitoring Seminar
 
Power Quality
Power QualityPower Quality
Power Quality
 
Introduction to Power Quality
Introduction to Power QualityIntroduction to Power Quality
Introduction to Power Quality
 
Power Quality Issues _Literature Survey
Power Quality Issues _Literature SurveyPower Quality Issues _Literature Survey
Power Quality Issues _Literature Survey
 
seminar report on power quality monitoring
seminar report on power quality monitoring  seminar report on power quality monitoring
seminar report on power quality monitoring
 
Unified power quality conditioner 2
Unified power quality conditioner 2Unified power quality conditioner 2
Unified power quality conditioner 2
 
Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...
 
Overview of power quality problems ppt
Overview of power quality problems pptOverview of power quality problems ppt
Overview of power quality problems ppt
 
Ppt
PptPpt
Ppt
 
Power Quality Issues
Power Quality IssuesPower Quality Issues
Power Quality Issues
 
Power quality issues in POWER SYSTEMS
Power quality issues in POWER SYSTEMSPower quality issues in POWER SYSTEMS
Power quality issues in POWER SYSTEMS
 
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRM
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRMPOWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRM
POWER QUALITY ISSUE WITH GRID CONNECTED WIND ENERGY SYSTRM
 
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...Practical Power System Harmonics, Earthing and Power Quality - Problems and S...
Practical Power System Harmonics, Earthing and Power Quality - Problems and S...
 
Reactive power consumption in modern power system
Reactive power consumption in modern power systemReactive power consumption in modern power system
Reactive power consumption in modern power system
 
950313411009
950313411009950313411009
950313411009
 
Voltage sag
Voltage sagVoltage sag
Voltage sag
 
Ajal UPQC
Ajal UPQC Ajal UPQC
Ajal UPQC
 
Harmonics in power system
Harmonics in power systemHarmonics in power system
Harmonics in power system
 
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMPOWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
 

Ähnlich wie Power quality

Powerqualityppt kuldeep
Powerqualityppt kuldeepPowerqualityppt kuldeep
Powerqualityppt kuldeepKuldeep Singh
 
1660034363151685.pptx
1660034363151685.pptx1660034363151685.pptx
1660034363151685.pptxPradip khatri
 
Power quality 1341013148
Power quality 1341013148Power quality 1341013148
Power quality 1341013148Pradosh Dhal
 
powerqualityppt-130820010049-phpapp02.pdf
powerqualityppt-130820010049-phpapp02.pdfpowerqualityppt-130820010049-phpapp02.pdf
powerqualityppt-130820010049-phpapp02.pdfgiahuy646563
 
Overview of power quality problems
Overview of power quality problemsOverview of power quality problems
Overview of power quality problemsMitesh Karmur
 
Power quality disturbances
Power quality disturbancesPower quality disturbances
Power quality disturbancesManasKumarPatro
 
International Journal of Computational Engineering Research (IJCER)
International Journal of Computational Engineering Research (IJCER)International Journal of Computational Engineering Research (IJCER)
International Journal of Computational Engineering Research (IJCER)ijceronline
 
Design Development and Testing of an Overvoltage and Undervoltage Protection ...
Design Development and Testing of an Overvoltage and Undervoltage Protection ...Design Development and Testing of an Overvoltage and Undervoltage Protection ...
Design Development and Testing of an Overvoltage and Undervoltage Protection ...Kunal Maity
 
windfarmgridissues.pdf
windfarmgridissues.pdfwindfarmgridissues.pdf
windfarmgridissues.pdfsundeepsiddula
 
Wind farm grid issues
Wind farm grid issuesWind farm grid issues
Wind farm grid issuesRohil Kumar
 
IRJET- A Review Paper on Power Quality Issues and Monitoring Techniques
IRJET- A Review Paper on Power Quality Issues and Monitoring TechniquesIRJET- A Review Paper on Power Quality Issues and Monitoring Techniques
IRJET- A Review Paper on Power Quality Issues and Monitoring TechniquesIRJET Journal
 
Power quality & demand side management
Power quality & demand side managementPower quality & demand side management
Power quality & demand side managementMark Anthony Enoy
 

Ähnlich wie Power quality (20)

63-pq.ppt
63-pq.ppt63-pq.ppt
63-pq.ppt
 
63-pq.ppt
63-pq.ppt63-pq.ppt
63-pq.ppt
 
Power Quality
Power QualityPower Quality
Power Quality
 
Powerqualityppt kuldeep
Powerqualityppt kuldeepPowerqualityppt kuldeep
Powerqualityppt kuldeep
 
Power quality 1
Power quality 1Power quality 1
Power quality 1
 
1660034363151685.pptx
1660034363151685.pptx1660034363151685.pptx
1660034363151685.pptx
 
OM PRAKASH.pptx
OM PRAKASH.pptxOM PRAKASH.pptx
OM PRAKASH.pptx
 
Power quality 1341013148
Power quality 1341013148Power quality 1341013148
Power quality 1341013148
 
powerqualityppt-130820010049-phpapp02.pdf
powerqualityppt-130820010049-phpapp02.pdfpowerqualityppt-130820010049-phpapp02.pdf
powerqualityppt-130820010049-phpapp02.pdf
 
power_ quality
power_ qualitypower_ quality
power_ quality
 
Power quality
Power  qualityPower  quality
Power quality
 
Overview of power quality problems
Overview of power quality problemsOverview of power quality problems
Overview of power quality problems
 
Power quality disturbances
Power quality disturbancesPower quality disturbances
Power quality disturbances
 
International Journal of Computational Engineering Research (IJCER)
International Journal of Computational Engineering Research (IJCER)International Journal of Computational Engineering Research (IJCER)
International Journal of Computational Engineering Research (IJCER)
 
Design Development and Testing of an Overvoltage and Undervoltage Protection ...
Design Development and Testing of an Overvoltage and Undervoltage Protection ...Design Development and Testing of an Overvoltage and Undervoltage Protection ...
Design Development and Testing of an Overvoltage and Undervoltage Protection ...
 
windfarmgridissues.pdf
windfarmgridissues.pdfwindfarmgridissues.pdf
windfarmgridissues.pdf
 
Wind farm grid issues
Wind farm grid issuesWind farm grid issues
Wind farm grid issues
 
Power Quality Improvement using AC To AC PWM converter for distribution line
Power Quality Improvement using AC To AC PWM converter for distribution linePower Quality Improvement using AC To AC PWM converter for distribution line
Power Quality Improvement using AC To AC PWM converter for distribution line
 
IRJET- A Review Paper on Power Quality Issues and Monitoring Techniques
IRJET- A Review Paper on Power Quality Issues and Monitoring TechniquesIRJET- A Review Paper on Power Quality Issues and Monitoring Techniques
IRJET- A Review Paper on Power Quality Issues and Monitoring Techniques
 
Power quality & demand side management
Power quality & demand side managementPower quality & demand side management
Power quality & demand side management
 

Mehr von Biswajit Pratihari (20)

Green Computing
Green ComputingGreen Computing
Green Computing
 
Cloud Computing
Cloud ComputingCloud Computing
Cloud Computing
 
Cloud Computing
Cloud ComputingCloud Computing
Cloud Computing
 
Artificial Intelligence
Artificial IntelligenceArtificial Intelligence
Artificial Intelligence
 
Artificial Intelligence & Robotics
Artificial Intelligence & RoboticsArtificial Intelligence & Robotics
Artificial Intelligence & Robotics
 
Light Fidelity (Li Fi)
Light Fidelity (Li Fi)Light Fidelity (Li Fi)
Light Fidelity (Li Fi)
 
Performance Testing in Oracle Apps
Performance Testing in Oracle AppsPerformance Testing in Oracle Apps
Performance Testing in Oracle Apps
 
Automation testing
Automation testingAutomation testing
Automation testing
 
Written pole-technology
Written pole-technologyWritten pole-technology
Written pole-technology
 
Power Line Carrier Communication
Power Line Carrier CommunicationPower Line Carrier Communication
Power Line Carrier Communication
 
Lunar solar power system
Lunar solar power systemLunar solar power system
Lunar solar power system
 
Surge supressor
Surge supressorSurge supressor
Surge supressor
 
Harmonic mitigating transformer
Harmonic mitigating transformerHarmonic mitigating transformer
Harmonic mitigating transformer
 
Cooling of power transformer
Cooling of power transformerCooling of power transformer
Cooling of power transformer
 
Cast resin transformer
Cast resin transformerCast resin transformer
Cast resin transformer
 
Witricity
WitricityWitricity
Witricity
 
Wireless power theft monitoring
Wireless power theft monitoringWireless power theft monitoring
Wireless power theft monitoring
 
Ultra sonic motor
Ultra sonic motorUltra sonic motor
Ultra sonic motor
 
Trf ptc
Trf ptcTrf ptc
Trf ptc
 
The E-Bomb
The E-BombThe E-Bomb
The E-Bomb
 

Power quality

  • 1. POWER QUALITY ANALYSIS: PROBLEMS & SOLUTIONS PARTHAVI PADHY ROLL NUMBER-0901106012 ELECTRICAL ENGG.
  • 2. INTRODUCTION  Power Quality means quality of the normal voltage supplied to your facility.  The growing use of microprocessors and electronic equipments has made us to focus on power quality .  Equipment and machinery can be damaged or even fail when subjected to power anomalies .  Voltage provided should be as close as possible to nominal voltage and waveform must be pure sine wave free from any harmonics and other disturbances.
  • 3. POWER QUALITY PROBLEMS: Power Quality problems can be broadly classified into following categories. • Voltage sags • Micro-interruptions • Long interruptions • Voltage spikes • Voltage swells • Harmonic distortion
  • 4. Voltage Sags A decrease of the normal voltage level between 10 and 90% of the nominal rms voltage at the power frequency, for durations of 0,5 cycle to 1 minute. Causes: • Faults on the transmission or distribution network. • Faults in consumer’s installation. • Connection of heavy loads and start-up of large motors. Consequences: • Malfunction of microprocessor-based control systems that may lead to a process stoppage. •Disconnection and loss of efficiency in electric rotating machines.
  • 5. Micro-Interruptions Total interruption of electrical supply for duration from few milliseconds to one or two seconds. Causes: • Opening and automatic reclosure of protection devices. • Insulation failure, lightning and insulator flashover. Consequences: •Tripping of protection devices. • Loss of information and malfunction of data processing equipment. • Stoppage of sensitive equipment (such as ASDs, PCs, PLCs).
  • 6. Long Interruptions  Total interruption of electrical supply for duration greater than 1 to 2 seconds. Causes: • Equipment failure in the power system network. • Storms and objects (trees, cars, etc) striking lines or poles, fire. • Human error, bad coordination or failure of protection devices. Consequences: • Stoppage of all equipment.
  • 7. Voltage Spikes Very fast variation of the voltage value for durations from a several microseconds to few milliseconds. Causes: • Lightning. • Switching of lines or power factor correction capacitors. • Disconnection of heavy loads. Consequences: • Destruction of components and of insulation materials. • Data processing errors or data loss. • Electromagnetic interference.
  • 8. Voltage Swells Momentary increase of the voltage, at the power frequency, outside the normal tolerances, with duration of more than one cycle and typically less than a few seconds. Causes: • Start/stop of heavy loads. • Poorly dimensioned power sources. • Poorly regulated transformers. Consequences: • Flickering of lighting and screens. • Damage or stoppage or damage of sensitive equipment.
  • 9. Harmonic Distortion Voltage or current waveforms assume non-sinusoidal shape. The waveform corresponds to the sum of different sine-waves with different magnitude and phase, having frequencies that are multiples of power-system frequency. Causes: Classic sources: electric machines working above the knee of the magnetization curve (magnetic saturation), arc furnaces, welding machines, rectifiers, and DC brush motors. Modern sources: all non-linear loads, such as power electronics equipment including ASDs, switched mode power supplies, data processing equipment, high efficiency lighting.
  • 10. Consequences of harmonic distortion • Increased probability of occurrence of resonance. • Nuisance tripping of thermal protections. • Electromagnetic interference. • Increase in the losses. • Loss of efficiency in electric machines (e.g. 5th harmonic).
  • 11. SolutionS for PQ ProblemS
  • 12. Grid Adequacy Many PQ problems have origin in T& D network. A proper planned and maintained grid will avoid many PQ problems. - High level of redundancy; - Cleaning of insulators; - Trimming of trees nearby power lines…
  • 13. Distributed Resources 1.Distributed Generation (DG) 2.Energy Storage (restoring technologies) • Flywheels • Supercapacitors • SMES
  • 14. Distributed Generation •Used to provide “clean power” to critical loads, isolating them from disturbances with origin in the grid. • Backup generators to assure energy supply to critical loads during sustained outages. •The most common solution is the combination of electrochemical batteries UPS and a diesel genset. At present, the integration of a flywheel and a diesel genset in a single unit is also becoming a popular solution, offered by many manufacturers.
  • 15. Distributed Resources – Energy Storage Systems Restoring technologies . Energy storage systems, also known as restoring technologies, are used to provide the electric loads with ride-through capability in poor PQ environment.
  • 16. Flywheels Electromechanical device that couples a rotating electric machine (motor/generator) with a rotating mass to store energy for short durations.
  • 17. Super capacitors New technology applied to capacitors • High power density • Long life and non-toxic
  • 18. Superconducting Magnetic Energy Storage (SMES) Energy is stored in the magnetic field of a coil made of superconductor material. • High power density • Very fast response • Very expensive (on development)
  • 19. Codes and Standards Need to regulate: • the minimum PQ level that utilities have to provide to consumers, and • the immunity level that equipment should have. Most relevant standards: • CBEMA curve • ITIC curve • IEC 61000 • EN 50160:2001 • IEEE standards - 519-1992 →Harmonics - 1100-1992 →Powering and grounding sensitive equipment - 1159-1992 →Monitoring power quality - 1250-1995 →Service of sensitive equipment
  • 21. Enhanced Interface Devices •Using proper interface devices, one can isolate the loads from disturbances deriving from the grid. Some of the enhanced interface devices are: A. Dynamic Voltage Restorer A dynamic voltage restorer (DVR) acts like a voltage source connected in series with the load. The output voltage of the DVR is kept approximately constant voltage at the load terminals. B. Transient Voltage Surge suppressors (TVSS) Transient voltage surge suppressors are used as interface between the power source and sensitive loads, so that the transient voltage is clamped by the TVSS before it reaches the load. C. Noise Filters Noise filters are used to avoid unwanted frequency current or voltage signals (noise) from reaching sensitive equipment. D. Static VAR Compensators Static VAR compensators (SVR) use a combination of capacitors and reactors to regulate the voltage quickly.
  • 22. E. Harmonic Filters Harmonic filters are used to reduce undesirable harmonics. They can be divided in two groups: • passive filters • active filters. Passive filters (left) consist in a low impedance path to the frequencies of the harmonics to be attenuated using passive components (inductors, capacitors and resistors). Active filters (right) analyse the current consumed by the load and create a current that cancel the harmonic current generated by the loads.
  • 23. Make End-use Devices Less Sensitive • In most cases, making the end-use devices less sensitive to PQ disturbances is more cost effective than buying equipment to mitigate these problems. • Some measures to increase equipment immunity: – Add a capacitor with larger capacity to power supplies; – Use cables with larger neutral conductors; – Derate transformers;
  • 24. Conclusions The availability of electric power with high quality is crucial for the running of the modern society. If some sectors are satisfied with the quality of the power provided by utilities, some others are more demanding. To avoid the huge losses related to PQ problems, the most demanding consumers must take action to prevent the problems. Among the various measures, selection of less sensitive equipment can play an important role. When even the most robust equipment is affected, then other measures must be taken, such as installation of restoring technologies, distributed generation or an interface device to avoid PQ problems.