SlideShare ist ein Scribd-Unternehmen logo
1 von 13
Advanced CCD Based Optical Emission Spectrometer
Bruker Elemental
Q4 TASMAN
think forward
OES
Starting with Innovation
Implementing intelligent innovation,
Bruker Elemental has designed the new
Q4 TASMAN spectrometer to achieve
unrivaled performance:
	New co-axial argon flow combines
analytically optimized flows with redu-
ced consumption. More accuracy can
be achieved analyzing small samples.
	Newly developed CCD-based spectro-
meter features ClearSpectrum techno-
logy.
	Analytical Solution Packages (ASP)
provide turn-key solutions for your
analytical requirements.
	Less down-time with the automatic
control and diagnosis functions leads
to higher availability.
Your Analytic Requirement is our
Inspiration
At Bruker Elemental, we design and
develop advanced OES systems to meet
or exceed your analytical needs. The new
Q4 TASMAN provides the answers you
need fast, using the very latest, state-of-
the-art technologies.
Our engineers have designed innovative
solutions which make the Q4 TASMAN
OES system fully suitable not only for
your dedicated applications, but also for
many general purpose applications.
The result is a completely new CCD-
based instrument, which lets you achieve
your goals faster, more reliably, and more
cost-effectively than ever before with
this class of instrument.
Co-axial argon flow:
reduced consumption
and minimized mainte-
nance.
The Analytical Performance that ExceedsYour Requirements
1	 Analysis results
2	 Display options:
	 Average,
	 standard deviations,
	 specification limits,
3	 OneClick operation,
	 instrument status
2
1
3
QMatrix user interface
Enjoy Shorter Measurement
Cycles
Q4 TASMAN features shorter measure-
ment cycles compared to any convent-
tional system. The newly developed
readout scans all CCDs up to 30 times
faster than previously. The results are
higher dynamic ranges with shorter
measurement times. Faster
time-to-result improves your efficiency
and increases your profitability.
Competitive Athlete at Heart
The optical system is the heart of the
spectrometer: the well-proven
Paschen-Runge mounting is equipped
with ClearSpectrum technology: the
combination of high-resolution CCDs
and the latest firmware provides excel-
lent performance from a very compact
design.
Spectra deconvolution and evaluation
are covered by a duo of firmware and
software. Just place the sample in
position and press the start button!
Performance is at the tip of your fingers.
After just a short while, accurate analysis
results appear with color indicators.
Everything is Goal-oriented
Co-axial argon flow puts the gas where
it is needed: at the burn spot eliminating
the need for a standby flow. In addition
the analysis of small samples and wires
is simpler than ever before.
Simply Analyze
Adjustable sample clamp provides simple sample positioning and sample exchange
Three Models for your Apps
The right solution for your application:
TASMAN 200 is ideally suited for all non-
ferrous applications, where UV elements
are not required; TASMAN 170 for e.g.
ferrous applications with important
elements in the UV spectrum (C, P, S,
As, Sn, B, etc.) and finally the powerful
TASMAN 130 capable of analyzing even
ultra-UV elements like e.g. nitrogen and
others.
Analytical Solution Packages
Q4 TASMAN offers dedicated solutions
for your analytical tasks. The Analytical
Solution Packages (ASP) are available
per matrix: elements, calibrations, alloys
and more.
In no time at all, you receive reliable,
complete analytical results.
Superior Technology
Q4 TASMAN unites an outstanding solu-
tion for metal analysis: optimal analytical
performance, user-friendly and cost-
effective operation.
Q4 TASMAN´s superior analytical per-
formance and economical run is a great
asset for your metal business.
Q4 TASMAN Models
Model	 Wavelength range
Q4 TASMAN 200	 200 - 620 nm
Q4 TASMAN 170	 170 - 620 nm
Q4 TASMAN 130	 130 - 620 nm
Technical Specifications
Art.No.101129/10/07/Rev.1
Optical System
	CCD sensors with high resolution
	Multi-detector Optics
	Paschen-Runge Mounting
	ClearSpectrum Technology
	Highest spectral sensitivity
Source Generator
	Maintenance-free, two phase PWM Generator
	Frequency 50 to 1000 Hz
	Spark & arc-like discharges from 10 µs to 2 ms
Software
	Intuitive Windows* based software for simple routine
operation
	Various user levels for secure and task-specific operations
	Functions for qualitative and quantitative analysis
	Complete Software Suite including analysis database
and interfaces to Microsoft Office* software
Analytical Solution Packages (ASP)
	Available for various matrices
	All relevant alloying elements
	Calibrations for all alloy groups
	Quality libraries with version control
Electrical Data
	100 to 240 V (50/60 Hz)
	600 W during measurement, 50 W standby
	16 A (240 V) slow blow fuse or 25 A (100 V) slow blow fuse
Weights & Dimensions
	Width 550 mm / 22 inches
Height 700 mm / 28 inches
Depth 820 mm / 32 inches
	Weight ~75 kg / ~165 lb.
*Windows, MS-SQL, MS-Office are registered trademarks of Microsoft Corporation
Q4 TASMAN
Bruker Elemental GmbH
Kastellstrasse 31-35
47546 Kalkar, Germany
Tel.	+49 (2824) 97650-0
Fax	+49 (2824) 97650-10
info@bruker-elemental.com
www.bruker-elemental.com
Bruker Elemental is continually improving its products and reserves the right to change specifications without
notice. Order No. 101125©
2009 Bruker Elemental GmbH.
Bruker AXS Inc.
40 Manning Road
Billerica, MA 01821, USA
Tel. +1 (978) 663-3660
Fax +1 (978) 667-5993
oes@bruker-axs.com
www.bruker-axs.com
Q4 TASMAN
Vietnamese Agency:
LOD
ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max %
C 15,0 0,0050 4,50 0,0015 1,50 0,0015 1,50 1,7000 4,50 0,0020 1,70 0,0020 0,40 0,1000 2,60 0,0010 1,60 1,3000 4,00
Si 15,0 0,0100 6,00 0,0015 1,70 0,0015 1,70 0,0020 5,00 0,0030 4,00 0,0020 1,30 0,0020 2,20 0,0030 1,80 0,0050 6,00
Mn 5,0 0,0020 19,00 0,0005 2,50 0,0005 2,50 0,0005 1,50 0,0010 19,00 0,0020 1,60 0,0010 1,60 7,0000 18,00 0,0010 4,50
P 10,0 0,0050 1,20 0,0010 0,08 0,0010 0,08 0,0010 1,20 0,0010 0,07 0,0010 0,04 0,0010 0,06 0,0010 0,11 0,0010 0,24
S 5,0 0,1500 0,70 0,0005 0,12 0,0005 0,80 0,0010 0,15 0,0005 0,10 0,0010 0,04 0,0010 0,09 0,0010 0,03 0,0010 0,13
Cr 20,0 0,0050 33,00 0,0020 5,50 0,0020 5,50 0,0020 1,30 6,0000 27,00 0,0020 27,00 0,0050 6,00 0,0005 2,50 0,0100 33,00
Mo 10,0 0,0100 11,00 0,0010 1,40 0,0010 1,40 0,0010 1,40 0,0050 3,00 0,0030 5,50 0,0020 11,00 0,0020 1,50 0,0020 4,00
Ni 15,0 0,0050 45,00 0,0015 6,50 0,0015 6,50 0,0015 1,80 0,0020 22,00 16,0000 42,00 0,0050 0,30 0,0020 2,00 0,0100 39,00
Cu 5,0 0,0050 8,00 0,0005 0,80 0,0005 0,80 0,0005 1,50 0,0005 8,00 0,0005 3,50 0,0010 0,25 0,0005 0,30 0,0005 6,50
Al 10,0 0,0050 3,00 0,0010 1,10 0,0010 1,10 0,0010 0,12 0,0010 0,05 0,0010 3,00 0,0020 0,04 0,0020 0,21 0,0020 0,20
As 10,0 0,0020 0,10 0,0010 0,09 0,0010 0,09 0,0010 0,09 0,0010 0,10 0,0010 0,13 0,0010 0,03
B 2,0 0,0010 1,10 0,0002 0,01 0,0002 0,01 0,0002 0,10 0,0010 1,20 0,0010 0,01
Bi 70,0 0,0100 0,12 0,0070 0,02 0,0070 0,02 0,0070 0,02
Ce 25,0 0,0050 0,25 0,0025 0,05 0,0025 0,05 0,0040 0,23
Co 5,0 0,0050 10,00 0,0005 0,90 0,0005 0,90 0,0015 0,11 0,0010 0,60 0,0030 10,00 0,0010 9,00
Mg 50,0 0,0050 0,12 0,0050 0,12 0,0050 0,06
Nb 10,0 0,0010 3,00 0,0010 0,33 0,0010 0,33 0,0010 0,07 0,0010 2,80 0,0050 0,65
Pb 30,0 0,0100 0,25 0,0030 0,25 0,0030 0,25 0,0030 0,03
Sb 50,0 0,0100 0,15 0,0050 0,11 0,0050 0,11 0,0050 0,15
Sn 5,0 0,0050 0,19 0,0005 0,13 0,0005 0,13 0,0005 0,20 0,0005 0,01 0,0010 0,02 0,0005 0,03 0,0010 0,12
Ta 300,0 0,0300 0,55 0,0300 0,55 0,0300 0,55
La 10,0 0,0020 0,08 0,0010 0,03 0,0010 0,03 0,0010 0,07
Ti 2,0 0,0010 2,50 0,0002 0,35 0,0002 0,35 0,0005 0,30 0,0010 0,45 0,0020 2,50
V 5,0 0,0050 11,00 0,0005 0,80 0,0005 0,80 0,0005 0,25 0,0005 0,90 0,0010 0,55 0,0010 11,00 0,0010 0,25
W 50,0 0,0100 19,00 0,0050 3,30 0,0050 3,30 0,0050 0,06 0,0200 0,50 0,0100 19,00
Zn 10,0 0,0020 0,03 0,0010 0,03
Zr 10,0 0,0020 0,10 0,0010 0,10 0,0010 0,10 0,0010 0,04
Se 30,0 0,0050 0,40 0,0030 0,03
Ca 1,0 0,0001 0,01 0,0001 0,01
Q4 Tasman 170 Fe-Base Calibration Ranges
Elem
ents
Fe - Ni-Resist/Cr-Hard
Fe160
Fe - Tool Steel
Fe140
Fe - Mn Steel
Fe150
Fe - Cr Cr/Ni Steel
Fe130
Fe - Cr/Ni - Ni Steel
Fe131
Fe - Free Cutting Steel
Fe115
Fe - Cast Iron
Fe120
Fe - Global
Fe100
Fe - Low Alloy Steel
Fe110
Q4 Tasman 170 Al-Base Calibration Ranges
Elem
ents
Al - Global Al - Global High Al - Low Alloy Al - Si Al - ZnAl - Cu Al - MgLOD
ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max %
Si 3,0 0,0050 25,00 0,0050 25,00 0,0003 2,00 5,0000 25,00 0,0010 1,50 0,0010 0,80 0,0010 0,45
Fe 20,0 0,0020 3,30 0,0020 3,30 0,0020 3,30 0,0020 1,60 0,0020 1,00 0,0020 0,55 0,0020 0,65
Cu 5,0 0,0010 22,00 0,0010 22,00 0,0010 0,45 0,0010 5,00 1,0000 22,00 0,0010 0,40 0,0010 2,80
Mn 5,0 0,0020 1,30 0,0020 12,00 0,0005 1,10 0,0005 0,70 0,0010 1,10 0,0005 0,90 0,0020 0,60
Mg 1,0 0,0010 11,00 0,0010 11,00 0,0001 1,70 0,0001 1,50 0,0010 2,20 1,0000 11,00 0,0100 5,00
Cr 3,0 0,0020 0,37 0,0020 0,37 0,0003 0,27 0,0020 0,27 0,0010 0,14 0,0005 0,33 0,0005 0,37
Ni 10,0 0,0020 4,50 0,0020 4,50 0,0010 0,30 0,0020 4,50 0,0020 2,00 0,0010 0,14 0,0020 0,06
Zn 10,0 0,0020 12,00 0,0020 12,00 0,0010 0,12 0,0020 5,50 0,0010 0,45 0,0010 0,18 1,0000 13,00
Ti 1,0 0,0010 0,30 0,0010 0,30 0,0001 0,18 0,0005 0,22 0,0002 0,28 0,0005 0,22 0,0002 0,20
Ag 2,0 0,0005 1,10 0,0002 0,02 0,0005 1,10
B 2,0 0,0003 0,03 0,0002 0,03
Ba 0,5 0,0010 0,02 0,0001 0,02
Be 0,5 0,0003 0,08 0,0001 0,00 0,0003 0,07 0,0003 0,01 0,0001 0,02 0,0003 0,01
Bi 20,0 0,0030 0,65 0,0020 0,65 0,0020 0,11 0,0030 0,06 0,0020 0,10
Ca 0,5 0,0002 0,02 0,0002 0,02 0,0001 0,01 0,0001 0,03 0,0001 0,00
Cd 3,0 0,0005 0,35 0,0005 0,35 0,0003 0,13 0,0005 0,02 0,0003 0,00
Co 10,0 0,0010 0,65 0,0010 0,65 0,0010 0,03 0,0010 0,60 0,0010 0,40
Ga 20,0 0,0020 0,04 0,0020 0,04 0,0020 0,04 0,0010 0,03 0,0010 0,04 0,0020 0,04
In 20,0 0,0020 0,02 0,0020 0,02
Li 2,0 0,0002 0,05 0,0002 0,05 0,0002 0,00 0,0003 0,00
Mo 50,0 0,0050 0,02 0,0050 0,02
Na 1,0 0,0005 0,03 0,0005 0,03 0,0001 0,03 0,0005 0,01 0,0002 0,01
P 10,0 0,0020 0,02 0,0010 0,01 0,0010 0,02
Pb 15,0 0,0050 1,00 0,0050 1,00 0,0015 1,00 0,0030 0,20 0,0030 0,09 0,0030 0,11 0,0050 0,03
Sn 20,0 0,0020 1,00 0,0020 1,00 0,0020 0,02 0,0020 0,33 0,0020 0,11 0,0020 0,11 0,0010 0,01
Sr 0,5 0,0010 0,15 0,0010 0,15 0,0001 0,00 0,0002 0,14
V 10,0 0,0020 0,12 0,0020 0,12 0,0010 0,06 0,0020 0,06 0,0020 0,11 0,0010 0,02 0,0020 0,02
Zr 2,0 0,0020 0,33 0,0020 0,33 0,0002 0,05 0,0010 0,11 0,0005 0,24 0,0020 0,01 0,0005 0,20
Sb 70,0 0,0070 0,14 0,0070 0,20 0,0070 0,14 0,0070 0,14
Hg 20,0 0,0020 0,08 0,0020 0,01
As 3,0 0,0030 0,01
Ce 25,0 0,0025 0,05
Elem
ents
Al - Global
Al100
Al - Global High
Al101
Al - Low Alloy
Al110
Al - Si
Al120
Al - Zn
Al150
Al - Cu
Al130
Al - Mg
Al140
Cu - Global Cu - Pure Cu - Zn Cu - Si Cu - Zn/Ni Cu - Ni
Q4 Tasman 170 Cu-Base Calibration Ranges
Elem
ents
Cu - Al Cu - Be/Co/AgCu - Gun Metal Cu - Sn/PbLOD
ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max %
Zn 2,0 0,0030 46,00 0,0002 0,14 12,0000 46,00 0,0200 14,00 12,0000 35,00 0,0005 0,90 2,0000 7,50 0,0020 1,50 0,0002 0,90 0,0005 0,14
Pb 20,0 0,1000 22,00 0,0020 0,40 0,0020 3,30 0,0050 0,90 0,0030 1,50 0,0030 0,06 0,0100 6,50 0,0020 22,00 0,0020 0,40 0,0020 0,06
Sn 2,0 0,0010 22,00 0,0002 0,11 0,0010 2,00 0,0020 1,10 0,0005 0,50 0,0010 0,07 1,5000 9,00 2,0000 22,00 0,0005 0,37 0,0020 0,11
P 2,0 0,0050 1,10 0,0002 0,07 0,0005 0,25 0,0020 0,08 0,0005 0,02 0,0005 0,04 0,0005 0,25 0,0005 1,10 0,0005 0,04
Mn 1,0 0,0100 7,00 0,0001 0,14 0,0005 6,00 0,0005 0,80 0,0010 0,90 0,0010 2,50 0,0002 0,06 0,0002 0,45 0,0020 7,00 0,0002 0,08
Fe 2,0 0,0050 6,50 0,0002 0,08 0,0005 5,00 0,0020 1,10 0,0005 0,95 0,0020 2,70 0,0005 0,40 0,0005 0,35 0,0010 6,60 0,0020 0,18
Ni 5,0 0,0050 35,00 0,0005 0,45 0,0020 3,30 0,0020 0,55 5,0000 20,00 7,0000 35,00 0,0005 3,00 0,0050 1,60 0,0020 7,00 0,0050 1,20
Si 5,0 0,0050 7,50 0,0005 0,04 0,0005 1,50 1,5000 8,00 0,0010 1,00 0,0020 0,70 0,0005 0,15 0,0010 0,20 0,0010 0,32 0,0010 0,18
Mg 1,0 0,0050 0,20 0,0001 0,01 0,0003 0,04 0,0005 0,11 0,0005 0,01 0,0005 0,01 0,0005 0,20
Cr 2,0 0,0010 2,50 0,0002 0,90 0,0010 0,13 0,0002 2,50 0,0010 0,06 0,0005 0,22 0,0010 0,13
Al 5,0 0,0050 12,00 0,0005 0,02 0,0005 8,00 0,0050 2,00 0,0010 0,50 0,0010 0,03 0,0005 0,23 0,0005 0,14 4,0000 12,00 0,0020 0,11
S 2,0 0,0050 0,13 0,0002 0,01 0,0010 0,01 0,0010 0,05 0,0005 0,18
As 5,0 0,0050 0,50 0,0005 0,03 0,0005 0,25 0,0010 0,13 0,0010 0,06 0,0010 0,28 0,0030 0,12 0,0005 0,50
Be 1,0 0,0010 2,80 0,0001 0,01 0,0002 0,01 0,0010 0,02 0,0010 2,80
Ag 3,0 0,0010 1,60 0,0003 0,55 0,0005 0,03 0,0010 0,08 0,0005 0,05 0,0005 0,03 0,0010 1,70
Co 5,0 0,0050 2,40 0,0005 0,04 0,0010 0,50 0,0020 0,25 0,0010 0,10 0,0050 2,50
Bi 5,0 0,0050 4,50 0,0005 0,08 0,0020 4,50 0,0010 0,01 0,0010 2,50
Cd 3,0 0,0020 0,13 0,0003 0,01 0,0020 0,13
Sb 15,0 0,0050 1,30 0,0015 0,30 0,0020 0,40 0,0010 0,15 0,0020 0,01 0,0020 1,30 0,0050 0,55
Zr 2,0 0,0050 0,40 0,0002 0,11 0,0020 0,40
Ti 1,0 0,0020 0,90 0,0001 0,00 0,0020 0,80
Au 5,0 0,0050 0,05 0,0010 0,06
C 5,0 0,0020 0,04 0,0010 0,03
Nb 10,0 0,0050 1,30 0,0030 1,50
Se 2,0 0,0050 1,40 0,0002 0,03 0,0050 1,40
Te 30,0 0,0050 0,07 0,0030 0,07
B 2,0 0,0002 0,01
Cu - Global
Cu100
Cu - Pure
Cu110
Cu - Zn
Cu120
Cu - Si
Cu121
Cu - Zn/Ni
Cu130
Cu - Ni
Cu140
Elem
ents
Cu - Al
Cu170
Cu - Be/Co/Ag
Cu180
Cu - Gun Metal
Cu150
Cu - Sn/Pb
Cu160
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com

Weitere ähnliche Inhalte

Andere mochten auch

Apresentação MBA - Consultoria de RH para PNE - GP André Duarte
Apresentação MBA - Consultoria de RH para PNE - GP André DuarteApresentação MBA - Consultoria de RH para PNE - GP André Duarte
Apresentação MBA - Consultoria de RH para PNE - GP André DuarteAndré Duarte, MBA
 
Evolução Urbana do Bairro Imperial de São Cristóvão - RJ
Evolução Urbana do Bairro Imperial de São Cristóvão - RJEvolução Urbana do Bairro Imperial de São Cristóvão - RJ
Evolução Urbana do Bairro Imperial de São Cristóvão - RJMaira Gizotti
 
Cognitivelearningtheory 101128142936-phpapp01 (1)
Cognitivelearningtheory 101128142936-phpapp01 (1)Cognitivelearningtheory 101128142936-phpapp01 (1)
Cognitivelearningtheory 101128142936-phpapp01 (1)Travis Clinton
 
Protein dna interactions
Protein dna interactionsProtein dna interactions
Protein dna interactionsMandeep Kaur
 
Immunostimulants role in aquaculture
Immunostimulants role in aquacultureImmunostimulants role in aquaculture
Immunostimulants role in aquacultureMandeep Kaur
 
Shallow foundation(by indrajit mitra)01
Shallow   foundation(by indrajit mitra)01Shallow   foundation(by indrajit mitra)01
Shallow foundation(by indrajit mitra)01Indrajit Ind
 
Spark Driven Big Data Analytics
Spark Driven Big Data AnalyticsSpark Driven Big Data Analytics
Spark Driven Big Data Analyticsinoshg
 

Andere mochten auch (9)

Apresentação MBA - Consultoria de RH para PNE - GP André Duarte
Apresentação MBA - Consultoria de RH para PNE - GP André DuarteApresentação MBA - Consultoria de RH para PNE - GP André Duarte
Apresentação MBA - Consultoria de RH para PNE - GP André Duarte
 
Evolução Urbana do Bairro Imperial de São Cristóvão - RJ
Evolução Urbana do Bairro Imperial de São Cristóvão - RJEvolução Urbana do Bairro Imperial de São Cristóvão - RJ
Evolução Urbana do Bairro Imperial de São Cristóvão - RJ
 
Cognitivelearningtheory 101128142936-phpapp01 (1)
Cognitivelearningtheory 101128142936-phpapp01 (1)Cognitivelearningtheory 101128142936-phpapp01 (1)
Cognitivelearningtheory 101128142936-phpapp01 (1)
 
Protein dna interactions
Protein dna interactionsProtein dna interactions
Protein dna interactions
 
ADH-Pharm LLC
ADH-Pharm LLCADH-Pharm LLC
ADH-Pharm LLC
 
Immunostimulants role in aquaculture
Immunostimulants role in aquacultureImmunostimulants role in aquaculture
Immunostimulants role in aquaculture
 
Histopathology
HistopathologyHistopathology
Histopathology
 
Shallow foundation(by indrajit mitra)01
Shallow   foundation(by indrajit mitra)01Shallow   foundation(by indrajit mitra)01
Shallow foundation(by indrajit mitra)01
 
Spark Driven Big Data Analytics
Spark Driven Big Data AnalyticsSpark Driven Big Data Analytics
Spark Driven Big Data Analytics
 

May phan tich thanh phan kim loai

  • 1. Advanced CCD Based Optical Emission Spectrometer Bruker Elemental Q4 TASMAN think forward OES
  • 2. Starting with Innovation Implementing intelligent innovation, Bruker Elemental has designed the new Q4 TASMAN spectrometer to achieve unrivaled performance: New co-axial argon flow combines analytically optimized flows with redu- ced consumption. More accuracy can be achieved analyzing small samples. Newly developed CCD-based spectro- meter features ClearSpectrum techno- logy. Analytical Solution Packages (ASP) provide turn-key solutions for your analytical requirements. Less down-time with the automatic control and diagnosis functions leads to higher availability. Your Analytic Requirement is our Inspiration At Bruker Elemental, we design and develop advanced OES systems to meet or exceed your analytical needs. The new Q4 TASMAN provides the answers you need fast, using the very latest, state-of- the-art technologies. Our engineers have designed innovative solutions which make the Q4 TASMAN OES system fully suitable not only for your dedicated applications, but also for many general purpose applications. The result is a completely new CCD- based instrument, which lets you achieve your goals faster, more reliably, and more cost-effectively than ever before with this class of instrument. Co-axial argon flow: reduced consumption and minimized mainte- nance. The Analytical Performance that ExceedsYour Requirements 1 Analysis results 2 Display options: Average, standard deviations, specification limits, 3 OneClick operation, instrument status 2 1 3 QMatrix user interface
  • 3. Enjoy Shorter Measurement Cycles Q4 TASMAN features shorter measure- ment cycles compared to any convent- tional system. The newly developed readout scans all CCDs up to 30 times faster than previously. The results are higher dynamic ranges with shorter measurement times. Faster time-to-result improves your efficiency and increases your profitability. Competitive Athlete at Heart The optical system is the heart of the spectrometer: the well-proven Paschen-Runge mounting is equipped with ClearSpectrum technology: the combination of high-resolution CCDs and the latest firmware provides excel- lent performance from a very compact design. Spectra deconvolution and evaluation are covered by a duo of firmware and software. Just place the sample in position and press the start button! Performance is at the tip of your fingers. After just a short while, accurate analysis results appear with color indicators. Everything is Goal-oriented Co-axial argon flow puts the gas where it is needed: at the burn spot eliminating the need for a standby flow. In addition the analysis of small samples and wires is simpler than ever before. Simply Analyze Adjustable sample clamp provides simple sample positioning and sample exchange Three Models for your Apps The right solution for your application: TASMAN 200 is ideally suited for all non- ferrous applications, where UV elements are not required; TASMAN 170 for e.g. ferrous applications with important elements in the UV spectrum (C, P, S, As, Sn, B, etc.) and finally the powerful TASMAN 130 capable of analyzing even ultra-UV elements like e.g. nitrogen and others. Analytical Solution Packages Q4 TASMAN offers dedicated solutions for your analytical tasks. The Analytical Solution Packages (ASP) are available per matrix: elements, calibrations, alloys and more. In no time at all, you receive reliable, complete analytical results. Superior Technology Q4 TASMAN unites an outstanding solu- tion for metal analysis: optimal analytical performance, user-friendly and cost- effective operation. Q4 TASMAN´s superior analytical per- formance and economical run is a great asset for your metal business. Q4 TASMAN Models Model Wavelength range Q4 TASMAN 200 200 - 620 nm Q4 TASMAN 170 170 - 620 nm Q4 TASMAN 130 130 - 620 nm
  • 4. Technical Specifications Art.No.101129/10/07/Rev.1 Optical System CCD sensors with high resolution Multi-detector Optics Paschen-Runge Mounting ClearSpectrum Technology Highest spectral sensitivity Source Generator Maintenance-free, two phase PWM Generator Frequency 50 to 1000 Hz Spark & arc-like discharges from 10 µs to 2 ms Software Intuitive Windows* based software for simple routine operation Various user levels for secure and task-specific operations Functions for qualitative and quantitative analysis Complete Software Suite including analysis database and interfaces to Microsoft Office* software Analytical Solution Packages (ASP) Available for various matrices All relevant alloying elements Calibrations for all alloy groups Quality libraries with version control Electrical Data 100 to 240 V (50/60 Hz) 600 W during measurement, 50 W standby 16 A (240 V) slow blow fuse or 25 A (100 V) slow blow fuse Weights & Dimensions Width 550 mm / 22 inches Height 700 mm / 28 inches Depth 820 mm / 32 inches Weight ~75 kg / ~165 lb. *Windows, MS-SQL, MS-Office are registered trademarks of Microsoft Corporation Q4 TASMAN Bruker Elemental GmbH Kastellstrasse 31-35 47546 Kalkar, Germany Tel. +49 (2824) 97650-0 Fax +49 (2824) 97650-10 info@bruker-elemental.com www.bruker-elemental.com Bruker Elemental is continually improving its products and reserves the right to change specifications without notice. Order No. 101125© 2009 Bruker Elemental GmbH. Bruker AXS Inc. 40 Manning Road Billerica, MA 01821, USA Tel. +1 (978) 663-3660 Fax +1 (978) 667-5993 oes@bruker-axs.com www.bruker-axs.com Q4 TASMAN Vietnamese Agency:
  • 5. LOD ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % C 15,0 0,0050 4,50 0,0015 1,50 0,0015 1,50 1,7000 4,50 0,0020 1,70 0,0020 0,40 0,1000 2,60 0,0010 1,60 1,3000 4,00 Si 15,0 0,0100 6,00 0,0015 1,70 0,0015 1,70 0,0020 5,00 0,0030 4,00 0,0020 1,30 0,0020 2,20 0,0030 1,80 0,0050 6,00 Mn 5,0 0,0020 19,00 0,0005 2,50 0,0005 2,50 0,0005 1,50 0,0010 19,00 0,0020 1,60 0,0010 1,60 7,0000 18,00 0,0010 4,50 P 10,0 0,0050 1,20 0,0010 0,08 0,0010 0,08 0,0010 1,20 0,0010 0,07 0,0010 0,04 0,0010 0,06 0,0010 0,11 0,0010 0,24 S 5,0 0,1500 0,70 0,0005 0,12 0,0005 0,80 0,0010 0,15 0,0005 0,10 0,0010 0,04 0,0010 0,09 0,0010 0,03 0,0010 0,13 Cr 20,0 0,0050 33,00 0,0020 5,50 0,0020 5,50 0,0020 1,30 6,0000 27,00 0,0020 27,00 0,0050 6,00 0,0005 2,50 0,0100 33,00 Mo 10,0 0,0100 11,00 0,0010 1,40 0,0010 1,40 0,0010 1,40 0,0050 3,00 0,0030 5,50 0,0020 11,00 0,0020 1,50 0,0020 4,00 Ni 15,0 0,0050 45,00 0,0015 6,50 0,0015 6,50 0,0015 1,80 0,0020 22,00 16,0000 42,00 0,0050 0,30 0,0020 2,00 0,0100 39,00 Cu 5,0 0,0050 8,00 0,0005 0,80 0,0005 0,80 0,0005 1,50 0,0005 8,00 0,0005 3,50 0,0010 0,25 0,0005 0,30 0,0005 6,50 Al 10,0 0,0050 3,00 0,0010 1,10 0,0010 1,10 0,0010 0,12 0,0010 0,05 0,0010 3,00 0,0020 0,04 0,0020 0,21 0,0020 0,20 As 10,0 0,0020 0,10 0,0010 0,09 0,0010 0,09 0,0010 0,09 0,0010 0,10 0,0010 0,13 0,0010 0,03 B 2,0 0,0010 1,10 0,0002 0,01 0,0002 0,01 0,0002 0,10 0,0010 1,20 0,0010 0,01 Bi 70,0 0,0100 0,12 0,0070 0,02 0,0070 0,02 0,0070 0,02 Ce 25,0 0,0050 0,25 0,0025 0,05 0,0025 0,05 0,0040 0,23 Co 5,0 0,0050 10,00 0,0005 0,90 0,0005 0,90 0,0015 0,11 0,0010 0,60 0,0030 10,00 0,0010 9,00 Mg 50,0 0,0050 0,12 0,0050 0,12 0,0050 0,06 Nb 10,0 0,0010 3,00 0,0010 0,33 0,0010 0,33 0,0010 0,07 0,0010 2,80 0,0050 0,65 Pb 30,0 0,0100 0,25 0,0030 0,25 0,0030 0,25 0,0030 0,03 Sb 50,0 0,0100 0,15 0,0050 0,11 0,0050 0,11 0,0050 0,15 Sn 5,0 0,0050 0,19 0,0005 0,13 0,0005 0,13 0,0005 0,20 0,0005 0,01 0,0010 0,02 0,0005 0,03 0,0010 0,12 Ta 300,0 0,0300 0,55 0,0300 0,55 0,0300 0,55 La 10,0 0,0020 0,08 0,0010 0,03 0,0010 0,03 0,0010 0,07 Ti 2,0 0,0010 2,50 0,0002 0,35 0,0002 0,35 0,0005 0,30 0,0010 0,45 0,0020 2,50 V 5,0 0,0050 11,00 0,0005 0,80 0,0005 0,80 0,0005 0,25 0,0005 0,90 0,0010 0,55 0,0010 11,00 0,0010 0,25 W 50,0 0,0100 19,00 0,0050 3,30 0,0050 3,30 0,0050 0,06 0,0200 0,50 0,0100 19,00 Zn 10,0 0,0020 0,03 0,0010 0,03 Zr 10,0 0,0020 0,10 0,0010 0,10 0,0010 0,10 0,0010 0,04 Se 30,0 0,0050 0,40 0,0030 0,03 Ca 1,0 0,0001 0,01 0,0001 0,01 Q4 Tasman 170 Fe-Base Calibration Ranges Elem ents Fe - Ni-Resist/Cr-Hard Fe160 Fe - Tool Steel Fe140 Fe - Mn Steel Fe150 Fe - Cr Cr/Ni Steel Fe130 Fe - Cr/Ni - Ni Steel Fe131 Fe - Free Cutting Steel Fe115 Fe - Cast Iron Fe120 Fe - Global Fe100 Fe - Low Alloy Steel Fe110
  • 6. Q4 Tasman 170 Al-Base Calibration Ranges Elem ents Al - Global Al - Global High Al - Low Alloy Al - Si Al - ZnAl - Cu Al - MgLOD ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max % Si 3,0 0,0050 25,00 0,0050 25,00 0,0003 2,00 5,0000 25,00 0,0010 1,50 0,0010 0,80 0,0010 0,45 Fe 20,0 0,0020 3,30 0,0020 3,30 0,0020 3,30 0,0020 1,60 0,0020 1,00 0,0020 0,55 0,0020 0,65 Cu 5,0 0,0010 22,00 0,0010 22,00 0,0010 0,45 0,0010 5,00 1,0000 22,00 0,0010 0,40 0,0010 2,80 Mn 5,0 0,0020 1,30 0,0020 12,00 0,0005 1,10 0,0005 0,70 0,0010 1,10 0,0005 0,90 0,0020 0,60 Mg 1,0 0,0010 11,00 0,0010 11,00 0,0001 1,70 0,0001 1,50 0,0010 2,20 1,0000 11,00 0,0100 5,00 Cr 3,0 0,0020 0,37 0,0020 0,37 0,0003 0,27 0,0020 0,27 0,0010 0,14 0,0005 0,33 0,0005 0,37 Ni 10,0 0,0020 4,50 0,0020 4,50 0,0010 0,30 0,0020 4,50 0,0020 2,00 0,0010 0,14 0,0020 0,06 Zn 10,0 0,0020 12,00 0,0020 12,00 0,0010 0,12 0,0020 5,50 0,0010 0,45 0,0010 0,18 1,0000 13,00 Ti 1,0 0,0010 0,30 0,0010 0,30 0,0001 0,18 0,0005 0,22 0,0002 0,28 0,0005 0,22 0,0002 0,20 Ag 2,0 0,0005 1,10 0,0002 0,02 0,0005 1,10 B 2,0 0,0003 0,03 0,0002 0,03 Ba 0,5 0,0010 0,02 0,0001 0,02 Be 0,5 0,0003 0,08 0,0001 0,00 0,0003 0,07 0,0003 0,01 0,0001 0,02 0,0003 0,01 Bi 20,0 0,0030 0,65 0,0020 0,65 0,0020 0,11 0,0030 0,06 0,0020 0,10 Ca 0,5 0,0002 0,02 0,0002 0,02 0,0001 0,01 0,0001 0,03 0,0001 0,00 Cd 3,0 0,0005 0,35 0,0005 0,35 0,0003 0,13 0,0005 0,02 0,0003 0,00 Co 10,0 0,0010 0,65 0,0010 0,65 0,0010 0,03 0,0010 0,60 0,0010 0,40 Ga 20,0 0,0020 0,04 0,0020 0,04 0,0020 0,04 0,0010 0,03 0,0010 0,04 0,0020 0,04 In 20,0 0,0020 0,02 0,0020 0,02 Li 2,0 0,0002 0,05 0,0002 0,05 0,0002 0,00 0,0003 0,00 Mo 50,0 0,0050 0,02 0,0050 0,02 Na 1,0 0,0005 0,03 0,0005 0,03 0,0001 0,03 0,0005 0,01 0,0002 0,01 P 10,0 0,0020 0,02 0,0010 0,01 0,0010 0,02 Pb 15,0 0,0050 1,00 0,0050 1,00 0,0015 1,00 0,0030 0,20 0,0030 0,09 0,0030 0,11 0,0050 0,03 Sn 20,0 0,0020 1,00 0,0020 1,00 0,0020 0,02 0,0020 0,33 0,0020 0,11 0,0020 0,11 0,0010 0,01 Sr 0,5 0,0010 0,15 0,0010 0,15 0,0001 0,00 0,0002 0,14 V 10,0 0,0020 0,12 0,0020 0,12 0,0010 0,06 0,0020 0,06 0,0020 0,11 0,0010 0,02 0,0020 0,02 Zr 2,0 0,0020 0,33 0,0020 0,33 0,0002 0,05 0,0010 0,11 0,0005 0,24 0,0020 0,01 0,0005 0,20 Sb 70,0 0,0070 0,14 0,0070 0,20 0,0070 0,14 0,0070 0,14 Hg 20,0 0,0020 0,08 0,0020 0,01 As 3,0 0,0030 0,01 Ce 25,0 0,0025 0,05 Elem ents Al - Global Al100 Al - Global High Al101 Al - Low Alloy Al110 Al - Si Al120 Al - Zn Al150 Al - Cu Al130 Al - Mg Al140
  • 7. Cu - Global Cu - Pure Cu - Zn Cu - Si Cu - Zn/Ni Cu - Ni Q4 Tasman 170 Cu-Base Calibration Ranges Elem ents Cu - Al Cu - Be/Co/AgCu - Gun Metal Cu - Sn/PbLOD ppm min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % min % max % Zn 2,0 0,0030 46,00 0,0002 0,14 12,0000 46,00 0,0200 14,00 12,0000 35,00 0,0005 0,90 2,0000 7,50 0,0020 1,50 0,0002 0,90 0,0005 0,14 Pb 20,0 0,1000 22,00 0,0020 0,40 0,0020 3,30 0,0050 0,90 0,0030 1,50 0,0030 0,06 0,0100 6,50 0,0020 22,00 0,0020 0,40 0,0020 0,06 Sn 2,0 0,0010 22,00 0,0002 0,11 0,0010 2,00 0,0020 1,10 0,0005 0,50 0,0010 0,07 1,5000 9,00 2,0000 22,00 0,0005 0,37 0,0020 0,11 P 2,0 0,0050 1,10 0,0002 0,07 0,0005 0,25 0,0020 0,08 0,0005 0,02 0,0005 0,04 0,0005 0,25 0,0005 1,10 0,0005 0,04 Mn 1,0 0,0100 7,00 0,0001 0,14 0,0005 6,00 0,0005 0,80 0,0010 0,90 0,0010 2,50 0,0002 0,06 0,0002 0,45 0,0020 7,00 0,0002 0,08 Fe 2,0 0,0050 6,50 0,0002 0,08 0,0005 5,00 0,0020 1,10 0,0005 0,95 0,0020 2,70 0,0005 0,40 0,0005 0,35 0,0010 6,60 0,0020 0,18 Ni 5,0 0,0050 35,00 0,0005 0,45 0,0020 3,30 0,0020 0,55 5,0000 20,00 7,0000 35,00 0,0005 3,00 0,0050 1,60 0,0020 7,00 0,0050 1,20 Si 5,0 0,0050 7,50 0,0005 0,04 0,0005 1,50 1,5000 8,00 0,0010 1,00 0,0020 0,70 0,0005 0,15 0,0010 0,20 0,0010 0,32 0,0010 0,18 Mg 1,0 0,0050 0,20 0,0001 0,01 0,0003 0,04 0,0005 0,11 0,0005 0,01 0,0005 0,01 0,0005 0,20 Cr 2,0 0,0010 2,50 0,0002 0,90 0,0010 0,13 0,0002 2,50 0,0010 0,06 0,0005 0,22 0,0010 0,13 Al 5,0 0,0050 12,00 0,0005 0,02 0,0005 8,00 0,0050 2,00 0,0010 0,50 0,0010 0,03 0,0005 0,23 0,0005 0,14 4,0000 12,00 0,0020 0,11 S 2,0 0,0050 0,13 0,0002 0,01 0,0010 0,01 0,0010 0,05 0,0005 0,18 As 5,0 0,0050 0,50 0,0005 0,03 0,0005 0,25 0,0010 0,13 0,0010 0,06 0,0010 0,28 0,0030 0,12 0,0005 0,50 Be 1,0 0,0010 2,80 0,0001 0,01 0,0002 0,01 0,0010 0,02 0,0010 2,80 Ag 3,0 0,0010 1,60 0,0003 0,55 0,0005 0,03 0,0010 0,08 0,0005 0,05 0,0005 0,03 0,0010 1,70 Co 5,0 0,0050 2,40 0,0005 0,04 0,0010 0,50 0,0020 0,25 0,0010 0,10 0,0050 2,50 Bi 5,0 0,0050 4,50 0,0005 0,08 0,0020 4,50 0,0010 0,01 0,0010 2,50 Cd 3,0 0,0020 0,13 0,0003 0,01 0,0020 0,13 Sb 15,0 0,0050 1,30 0,0015 0,30 0,0020 0,40 0,0010 0,15 0,0020 0,01 0,0020 1,30 0,0050 0,55 Zr 2,0 0,0050 0,40 0,0002 0,11 0,0020 0,40 Ti 1,0 0,0020 0,90 0,0001 0,00 0,0020 0,80 Au 5,0 0,0050 0,05 0,0010 0,06 C 5,0 0,0020 0,04 0,0010 0,03 Nb 10,0 0,0050 1,30 0,0030 1,50 Se 2,0 0,0050 1,40 0,0002 0,03 0,0050 1,40 Te 30,0 0,0050 0,07 0,0030 0,07 B 2,0 0,0002 0,01 Cu - Global Cu100 Cu - Pure Cu110 Cu - Zn Cu120 Cu - Si Cu121 Cu - Zn/Ni Cu130 Cu - Ni Cu140 Elem ents Cu - Al Cu170 Cu - Be/Co/Ag Cu180 Cu - Gun Metal Cu150 Cu - Sn/Pb Cu160
  • 8. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
  • 9. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
  • 10. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
  • 11. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
  • 12. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com
  • 13. Xem chi tiết tại: http://www.mayquangpho.org hoặc http://www.att-vn.com