Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and setup guide
1. 3-Way or More Applications (Multi-location)
Remote Devices
Cat. No. VP00R-10, Coordinating Dimmer Remote
Cat. No. VP00R-1L, Matching Dimmer Remote
Cat. No. VP0SR-10, Coordinating Switch Remote
Cat. No. VP0SR-1L, Matching Switch Remote
120VAC, 60Hz PK-93461-10-00-2A
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations. • Use only one (1) Vizia +™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s)
• If you are unsure about any part of these instructions, consult a qualified electrician. will turn the light on at the brightness level selected at the dimmer.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a • Recommended minimum wall box depth is 2-1/2".
transformer-operated appliance. • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• For Hi-lume® or Eco-10® (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications. • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Vizia +™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia rf +™ devices for multi-location • Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
switching.
Tools needed to install your Remote: Step 2 cont’d Step 4b 3-Way Wiring with Coordinating Remote (no LEDs) NOTE: The control must be installed in a wall box that has a Load
Step 4d cont’d
Application: connection. The matching remote must be installed in a wall box with
Slotted/Phillips Screwdriver Electrical Tape NOTE: Incandescent and Magnetic Low Voltage a Line Hot connection and a Neutral connection. A Neutral wire to the WIRING COORDINATING REMOTE:
Pliers Pencil installations only. NOTE: Screw terminal dimmer matching remote needs to be added as shown. Connect wires per WIRING DIAGRAM as follows:
Cutters Ruler depicted. If you are unsure about any part of these instructions, consult a NOTE: "BK" and "RD" terminals on coordinating remote are
qualified electrician. unused. Tighten both screws.
Changing the color of your Device: Coordinating Remote Dimmer
Your device may include color options. To change color of the face NOTE: Maximum wire length from control to all installed remotes NOTE: Maximum wire length from control to last remote is
proceed as follows: cannot exceed 300 ft (90 m). 300 ft (90 m).
Side Wire Connection Back Wire Wiring Matching Remote (wall box with Line Hot
Side wire terminals accept • Green or bare copper wire in wall box to Green terminal screw.
(either hole may be used) Terminal
Bk
1
Bk
1 connection):
#14 AWG solid copper wire Screw marked • Load wall box wire identified (tagged) when removing old switch
Back wire openings use 2 2
Connect wires per WIRING DIAGRAM as follows:
only. Black (Bk) to First Traveler (note color as above).
#14-12 AWG solid copper wire only.
Terminal
3 3 • Green or bare copper wire in wall box to Green terminal screw. • Second Traveler wall box wire (note color as above) to terminal
Screw marked 4 4
Yellow/Red YL/RD
RD
YL/RD
RD • Line Hot (common) wall box wire identified (tagged) when removing screw marked "YL/RD". This traveler from the remote must go to
(YL/RD) 5 5
old switch and First Traveler to terminal screw marked "BK" or Black the terminal screw marked "YL/RD" or Yellow/Red control lead.
5/8" Terminal
dimmer lead.
(1.6 cm) Screw marked • Remove White insulating label from terminal screw marked
Strip Gage (measure bare wire here or Red (RD)
• Second Traveler wall box wire from control to remote terminal screw "WH".
use gage on back of the dimmer)
marked "YL/RD" (note wire color). This traveler from the remote • Line Neutral wall box wire to terminal screw marked "WH".
Coordinating Remote (no LEDs) Dimmer must go to terminal screw marked "YL/RD" or Yellow/Red control
• Proceed to Step 6.
Line up tabs and lead.
Push in side at tab press in sides one at not used
Wh Bk hot (Black)
• Line Neutral wall box to remote terminal screw marked "WH".
to release a time to attach • Make sure that the ends of the wires from the wall box are straight Black
Bk
Step 5a 4-Way Wiring with Matching Remote (w/LEDs)
(cut if necessary).
Green
Ground Green
Wiring Dimmer (wall box with Load connection): Application:
Ground
• Remove insulation from each wire in the wall box as shown. NOTE: Incandescent and Magnetic Low Voltage
INSTALLING YOUR REMOTE RD YL/RD RD YL/RD Line Connect wires per WIRING DIAGRAM as follows:
Load installations only.
120vAC, 60hz • Green or bare copper wire in wall box to Green terminal screw or
3-Way Wiring with Matching Remote (w/LEDs) NOTE: Screw terminal dimmer depicted.
NOTE: Use check boxes when Steps are completed. Step 4a Green control lead.
Application: White
Matching Remote Matching Remote Dimmer
NOTE: Incandescent and Magnetic Low Voltage • Load wall box wire identified (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall box from Step 2)
Step 1 WARNING: To avoid fire, shock, or death; installations only. Neutral (White) (tagged) when removing old switch Terminal Terminal
Additional
turn off power at circuit breaker or fuse and test NOTE: Screw terminal dimmer depicted. to terminal screw marked "RD" or Screw marked
White (Wh) Neutral Wire
Screw marked
White (Wh)
Additional
Neutral Wire
that power is off before wiring! WIRING DIMMER: Red control lead. 4
2
Matching Remote Dimmer Connect wires per WIRING DIAGRAM as follows: • First Traveler Line Hot to terminal Terminal
Bk
Terminal 1
3 Bk Bk
Terminal Screw marked 1 Screw marked
Screw marked Additional
Neutral Wire
NOTE: When using the coordinating remote without LEDs, the dimmer screw marked "BK" or Black Black (Bk) 4 Black (Bk) 5
2
White (Wh)
can be installed on either the Line or Load side of the 3-way circuit. control lead. Terminal 3 4
3
4 Screw marked Terminal
Bk
2
Bk
NOTE: Maximum wire length from dimmer to all installed remotes • Remove Red insulating label from Yellow/Red 5 Screw marked
YL/RD
RD
2
RD
1
RD
Terminal (YL/RD) Yellow/Red YL/RD YL/RD
Screw marked 1
2
cannot exceed 300 ft (90 m). terminal screw marked "YL/RD" or (YL/RD) 6
5
Black (Bk) 4
• Green or bare copper wire in wall box to Green terminal screw or Yellow/Red control lead.
3
Terminal 3
Screw marked 1
Green dimmer lead. • Second Traveler wall box wire
Yellow/Red
(YL/RD)
YL/RD
RD 5
YL/RD
RD
5 • Line Hot (common) wall box wire identified (tagged) when removing (note color as above) to terminal
old switch to dimmer terminal screw marked "BK" or Black dimmer screw marked "YL/RD" or Yellow/Red control lead. This traveler
lead. from the control must go to the terminal screw on the remote Matching Remote Matching Remote
marked "YL/RD". (w/LEDs) (w/LEDs) Dimmer
Identifying your wiring application (most • First Traveler wall box wire to terminal screw marked "RD" or Red
Step 2 • Line neutral wall box wire to terminal screw marked "WH" or
common): dimmer lead (note wire color). This traveler from the dimmer must
go to the terminal screw on the remote marked "RD". White control lead. hot (Black) Wh Bk Wh Bk Bk
NOTE: If the wiring in the wall box does not resemble Matching Remote (w/LEDs) Dimmer
• Remove Red insulating label from terminal screw marked • Proceed to Step 6. Green
Ground
Green Green
Black
any of these configurations, consult a qualified Ground Ground
electrician. hot (Black)
Wh Bk Bk "YL/RD" or Yellow/Red dimmer lead. YL/RD
Step 4d 3-Way Wiring with Coordinating Remote (no Line YL/RD YL/RD RD
Load
Green
Ground
Green
Ground
• Second Traveler wall box wire to terminal screw marked "YL/RD" or LEDs) for Controls with Neutral Connection 120vAC, 60hz
Black
Yellow/Red dimmer lead (note wire color). This traveler from the
Application: White
Line YL/RD RD YL/RD dimmer must go to the terminal screw on the remote marked "YL/RD".
120vAC, 60hz
Load NOTE: Electronic Low Voltage, Mark 10™, Quiet
WIRING COORDINATING REMOTE: Fan Speed and Electronic Switch installations only. Neutral (White)
White Connect wires per WIRING DIAGRAM as follows: NOTE: Dimmer is depicted.
1 2 1 3 NOTE: Maximum wire length from dimmer to last remote is
Neutral (White) 300 ft (90 m). Coordinating Remote Control
2 Terminal NOTE: The dimmer must be installed in a wall box that has a Load
• Green or bare copper wire in wall box to Green terminal screw. Screw marked
3 4 NOTE: The dimmer must be installed in a wall box that has a Load
White (WH) connection. The matching remote must be installed in a wall box
• Load wall box wire identified (tagged) when removing old switch to Black
with a Line Hot connection and a Neutral connection. A Neutral wire
4 5 connection. The matching remote must be installed in a wall box with terminal screw marked "BK".
BK 1
a Line Hot connection and a Neutral connection. A Neutral wire to the
White to the matching remote needs to be added as shown.
5 6 2
matching remote needs to be added as shown. • First Traveler wall box wire (note color as above) to terminal screw 1
2
If you are unsure about any part of these instructions, consult a
marked "RD". This traveler from the remote must go to the terminal 3 Green
qualified electrician.
If you are unsure about any part of these instructions, consult a screw on the dimmer marked "RD" or Red dimmer lead. 4
qualified electrician. YL/RD
RD 5 3
NOTE: Maximum wire length from dimmer to all installed remotes
• Second Traveler wall box wire (note color as above) to terminal Terminal
Red
cannot exceed 300 ft (90 m).
NOTE: Maximum wire length from dimmer to all installed remotes screw marked "YL/RD". This traveler from the remote must go to Screw marked 4
cannot exceed 300 ft. Yellow/Red Yellow/Red Wiring Matching Remote (4-Way wall box with Line
3-Way 4-Way the terminal screw on the dimmer marked "YL/RD" or Yellow/Red (YL/RD)
Wiring Matching Remote (wall box with Line Hot
5 Hot connection):
1. Line or Load (See important 1. First Traveler – note color dimmer lead.
connection): Connect wires per WIRING DIAGRAM as follows:
instruction below) 2. Second Traveler – tagged • Remote terminal screw marked "WH" should have White insulation
Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw.
2. Neutral label affixed. Coordinating Remote (no LEDs) Control
3. Neutral • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire from dimmer in
3. Ground 4. Ground NOTE: If insulating label is not affixed to terminal screw marked
• Line Hot (common) wall box wire identified (tagged) when removing WH BK White Black Hot (Black) the 3-way box to remote terminal screw marked "BK" in the
4. First Traveler – note color "WH", use electrical tape to cover. not used
5. Third Traveler – note color old switch and First Traveler to remote terminal screw marked “BK” 4-way box, and to the terminal screw marked "BK" of the
5. Second Traveler – note color • Proceed to Step 6. Black Green
Ground
Green
Ground remaining remote in the 3-way box.
6. Fourth Traveler – tagged or the Black dimmer lead.
NOTE: For matching remote 3-Way Wiring with Matching Remote RD Red YL/RD • Second Traveler (tagged) and Fourth Traveler (tagged) wall box
NOTE: For matching remote • Second Traveler wall box wire from dimmer to remote terminal Step 4c not used YL/RD Line
w/LEDs installation, the First screw marked “YL/RD” (note wire color). This traveler from the (w/LEDs) for Controls with Neutral Connection Load 120VAC, 60Hz wire from dimmer in the 3-way box to remote terminal screw
w/LEDs installation, the First marked "YL/RD" in the 4-way box, and to the terminal screw
Traveler becomes Line Hot. remote must go to the terminal screw on the dimmer marked Application:
Traveler becomes Line Hot. White marked "YL/RD" of the remaining remote in the 3-way box (note
“YL/RD” or the Yellow/Red dimmer lead. NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan
IMPORTANT: Speed and Electronic Switch installations only. wire colors). This traveler from the remotes must go to the
• Line Neutral wall box to remote terminal screw marked “WH”. Neutral (White) terminal screw on the dimmer marked "YL/RD" or the Yellow/Red
For 3-Way applications, note that one of the screw terminals from NOTE: Dimmer is depicted.
Wiring Dimmer (wall box with Load connection): dimmer lead.
the old switch being removed will usually be a different color (Black) Matching Remote Control
Connect wires per WIRING DIAGRAM as follows: WIRING CONTROL: • Line Neutral wall box wire to remote terminal screw marked
or labeled Common. Tag that wire with electrical tape and identify Terminal Green
as the common (Line or Load) in both the dimmer wall box and • Green or bare copper wire in wall box to Green terminal screw or Screw marked Additional
Neutral Wire
Connect wires per WIRING DIAGRAM as follows: "WH".
White (WH)
remote wall box. Green dimmer lead. Black
4 NOTE: The control must be installed in a wall box that has a Line Hot
2
Connection.
Wiring MATCHING REMOTE (3-Way wall box with Line
• Load wall box wire identified (tagged) when removing old switch to BK
Hot connection):
For 4-Way applications, note that the old switch being removed Terminal 2
dimmer terminal screw marked “RD” or the Red dimmer lead. Screw marked 1 White NOTE: Maximum wire length from dimmer to all installed remotes Connect wires per WIRING DIAGRAM as follows:
will have 4 screws plus a ground screw. Tag the two same color Black (BK) 4
insulated wires with electrical tape. • First Traveler Line Hot to dimmer terminal screw marked “BK” or the cannot exceed 300 ft (90 m).
Terminal 3 Red 3 • Green or bare copper wire in wall box to Green terminal screw.
Black dimmer lead. Screw marked 1
• Green or bare copper wire in wall box to Green terminal screw or
Yellow/Red RD 5 • Line Hot (common) wall box wire identified (tagged) when
• Remove Red insulating label from terminal screw marked “YL/RD” (YL/RD)
YL/RD
Green control lead.
Step 3 Preparing and connecting wires: 5 removing old switch and First Traveler dimmer terminal screw
or Yellow/Red dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing marked "BK" or the Black dimmer lead.
This remote can be wired using side wire terminal Yellow/Red
• Second Traveler wall box wire (note color as above) to dimmer old switch to terminal screw marked "BK" or Black control lead.
screws or through backwire openings. Choose • Second Traveler wall box wire from dimmer to remote terminal
appropriate wire stripping specifications accordingly. terminal screw marked “YL/RD” or the Yellow/Red dimmer lead. • First Traveler wall box wire to terminal screw marked "RD" or Red screw marked "YL/RD" (note wire color as above). This traveler
This traveler from the dimmer must go to the terminal screw on the Matching Remote (w/LEDs) Control control lead (note wire color). from the remote must go to the terminal screw on the dimmer
remote marked “YL/RD”. • Remove Red insulating label from terminal screw marked "YL/RD" marked "YL/RD" or the Yellow/Red dimmer lead.
• Proceed to Step 6. WH BK White Black or Yellow/Red control lead. • Line Neutral wall box wire to remote terminal screw marked
Hot (Black)
Green
Ground
Green
Ground
• Second Traveler wall box wire to terminal screw marked "YL/RD" "WH".
Black or Yellow/Red control lead (note wire color). This traveler from
YL/RD Red Yellow/Red the control must go to the terminal screw on the remote marked
Line
120VAC, 60Hz Load "YL/RD".
Cut
• Line Neutral wall box wire to terminal screw marked "WH" or White
(if necessary) White
control lead.
Neutral (White)