The V3 Ring has the widest indications for use of any sectional matrix ring. The only nickel-titanium ring, the V3 ensures optimal separation forces to produce perfect, tight contacts and an anatomically correct Class II composite restoration.
1. Clinical Case
Composite restoration by Dr Simon McDonald
US: 1-800-811-3949 UK: 0800-311-2097
CA: 1-866-316-9007 NZ: 0800-TRIODENT
INT: +64-7-549-5612 AU: 1-800-350-421
If you have a great new product idea or wish to contact us for more information on our great
products, go to www.triodent.com/product-information-request.
2. Composite restoration
By Simon McDonald
1 2
Pre-op with fractured MOL composite. A purple (large) Wave-Wedge was placed interproximally to
depress the rubber dam and gingival tissues. The wedge was
lubricated to allow it to slide in.
3 4
Completed preparation. Note that original restoration extended A 5.5mm V3 Matrix was placed without removing the Wave-
lingually and this created a wide embrasure. Wedge, which acts as a guide for the matrix and also avoids
entrapment of gingival tissue between the matrix and the tooth.
US: 1-800-811-3949 UK: 0800-311-2097
CA: 1-866-316-9007 NZ: 0800-TRIODENT
INT: +64-7-549-5612 AU: 1-800-350-421
If you have a great new product idea or wish to contact us for more information on our great
products, go to www.triodent.com/product-information-request. Case Study 2
3. Composite restoration
By Simon McDonald
5 6
Narrow V3 Ring was placed. Note how the ring did not collapse into Cured composite resin prior to matrix removal. The composite in
the cavity on the lingual side. this case was Gradia Direct P-NT from GC.
7 8
Occlusal view of the restoration immediately after matrix removal. Buccal view of the restoration immediately after matrix removal.
Note the lack of flash.
US: 1-800-811-3949 UK: 0800-311-2097
CA: 1-866-316-9007 NZ: 0800-TRIODENT
INT: +64-7-549-5612 AU: 1-800-350-421
If you have a great new product idea or wish to contact us for more information on our great
products, go to www.triodent.com/product-information-request. Case Study 3
4. Composite restoration
By Simon McDonald
9 10
Occlusal view of the completed restoration. Lingual view of the completed restoration.
11 12
Final image after the rubber dam was removed. Post-op radiograph.
US: 1-800-811-3949 UK: 0800-311-2097
CA: 1-866-316-9007 NZ: 0800-TRIODENT
INT: +64-7-549-5612 AU: 1-800-350-421
If you have a great new product idea or wish to contact us for more information on our great
products, go to www.triodent.com/product-information-request. Case Study 4