SlideShare ist ein Scribd-Unternehmen logo
1 von 20
Downloaden Sie, um offline zu lesen
Industrivej 28, Stilling · 8660 Skanderborg · Denmark · Tel: +45 89 93 10 00 · Fax: +45 89 93 10 01 · info@kamstrup.com · www.kamstrup.com
MULTICAL® 402
Application
MULTICAL® 402 is the compact
ultrasonic meter which registers the
exact consumption due to its supreme
measuring accuracy. The meter is
maintenance-free and has a long
lifetime which guarantees minimum
yearly operating costs.
MULTICAL® 402 is used for heat,
cooling and combined heat /cool-
ing measurement in all water-based
systems with temperatures from 2 to
160°C. The meter has been developed
for measurement of energy consump-
tion in family and multiple occupancy
housing, housing associations, blocks
of flats and small industry.
Functionality
MULTICAL® 402 consists of calcula-
tor, flow sensor and two temperature
sensors and is simple to install, read
and verify. Our flow sensor range for
MULTICAL® 402 comprises of the sizes
0.6 – 15 m³/h, and the supply options
are 230 or 24 VAC mains module,
2xAA-cell battery, or D-cell battery with
up to 16 years’ lifetime. MULTICAL®
402 is fitted with a connector for the
supply and thus, it is easy to change
battery or mains supply.
By means of the calculator’s two front
keys it is easy to adjust date and time
or reset operating hour counter and
info-event counter. Furthermore, the
keys can be used to display log data,
incl. yearly or monthly logger.
MULTICAL® 402 receives pulses from
up to two connected hot or cold
water meters and carries out remote
accumulation of energy and volume
via pulse outputs. If you change from
pulse input to pulse output, the meter
is automatically configured for pulse
inputs and pulse outputs respectively
– without manual reconfiguration.
Wireless reading
The meter is remotely read via Wire-
less M-Bus or radio module. Con-
sumption data is read, saved and
transferred by means of the USB Meter
Reader. Furthermore, radio can be
read by means of a hand-held terminal
or form part of a Kamstrup radio
network. The transferred data is used
for individual billing, consumption
analysis and/or energy optimisation.
Compact meter for heat and cooling with maximum functionality
D A T A S H E E T
„„ Up to 16 years’ battery lifetime
„„ Set/reset function
„„ Pulse outputs for energy and volume
„„ Pulse inputs for up to two water meters
„„ Wireless reading via Wireless M-Bus or radio
0200M12
MID-2004/22/EC 22.52
05.04PTB
2 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Content
	 Calculator functions	 3
	 Pulse outputs and pulse inputs of the modules	 7
	 Cabinet design	 8
	 Approved meter data	 9
	 Electrical data	 10
	 Mechanical data	 12
	 Materials	13
	 Accuracy	14
	 Dimentional sketches	 16
	 Pressure loss	 19
	 Accessories	20
Energy calculation
MULTICAL® 402 calculates energy based on the formula in
EN 1434-1:2004, in which the international temperature scale from
1990 (ITS-90) and the pressure definition of 16 bar is used.
The energy calculation can in a simplified way be expressed as:
Energy = V x ∆Θ x k.
V 	 is the supplied water volume
∆Θ	 is the temperature difference measured
k	 is the thermal coefficient of water
The calculator always calculates energy in [Wh], and then it is converted into the selected measur-
ing unit.
Application types
MULTICAL® 402 operates with four different energy formulas, E1...E9, that are all calculated in
parallel in connection with each integration no matter how the meter is configured.
The four energy types are calculated as follows:
E1=V1(T1-T2)k	 Heat energy	 (V1 in flow or return)
E3=V1(T2-T1)k	 Cooling energy	 (V1 in flow or return)
E8=m³xT1	 (Flow pipe)
E9=m³xT2	 (Return pipe)
This renders MULTICAL® 402 capable of calculating the heat and cooling energy of most applica-
tions, both closed and open systems.
All energy types are data logged and can be displayed in-dependent of configuration.
Flow measurement
MULTICAL® 402 calculates current water flow every 12 seconds or every
4 seconds depending on configuration.
Power measurement
MULTICAL® 402 calculates current power on the basis of current water
flow and the temperature difference measured in connection with the
latest integration.
Current power is updated in the display every 24 seconds or every 4
seconds depending on configuration.
Calculator functions
35810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
E [Wh] = V x ∆Θ x k x 1000
E [kWh] = E [Wh] / 1,000
E [MWh] = E [Wh] / 1,000,000
E [GJ] = E [Wh] / 277,780
E [Gcal] = E [Wh] / 1,163,100
The upper push button is used to switch between the
primary readings. The consumers typically use the first
primary readings in connection with self-reading for bill-
ing purposes.
The lower push button is used to show secondary informa-
tion on the selected primary reading.
Min. and max. flow and power
MULTICAL® 402 registers minimum and maximum flow and power on a
monthly as well as on a yearly basis. The registrations which can be read
via data communication include max. and min. flow and power values,
all with date indication.
All max. and min. values are calculated as largest and smallest aver-
age respectively of a number of current flow or power measurements.
The average period used for all calculations is selected in the interval
1…1440 min.
Temperature measurement
MULTICAL® 402 is available in different versions for either Pt100 or
Pt500 sensors in a 2-wire version.
The measuring circuit includes a high resolution analog/
digital converter with a temperature range of 0,00°C…165,00°C.
In addition to current temperatures for the energy calculation average
temperatures on a yearly and monthly basis can also be displayed.
Display functions
MULTICAL® 402 is equipped with a clear LC display including 8 digits, units of measurement and infor-
mation panel. In connection with energy and volume readings 7 digits and the units of measurement to
match are used, whereas 8 digits are used when e.g. meter number is read.
As a starting point the display shows accumulated energy. When the push buttons are activated the
display reacts immediately by calling other readings. The display automatically returns to accumulated
energy reading 4 minutes after the latest activation of the push buttons.
Calculator functions
4 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Info code Description Response time
0 No irrigularities -
1 Supply voltage has been cut off -
4 T2 sensor outside range, short-circuited or cut off < 30 sec.
8 T1 sensor outside range, short-circuited or cut off < 30 sec.
4096 Flow sensor with weak signal or air < 30 sec.
16384 Flow sensor with wrong flow direction < 30 sec.
Calculator functions
Set/reset function
The set/reset function of MULTICAL® 402 makes it possible to change a number of parameters by
means of the two buttons on the meter’s front.
The following parameters can be changed:
•	 Date
•	 Hour
•	 Input A (preset of register)
•	 Input B (preset of register)
•	 Meter no. of Input A
•	 Meter no. of Input B
•	 Primary M-Bus address
•	 Operating hour counter (reset)
•	 Info-event counter (reset)
As the installation seal is broken, the change can only be made by the energy supplier.
Info codes
MULTICAL® 402 constantly monitors a number of important functions, e.g. power supply, temperature
sensors and leakage alarms. Should a serious error occur in the measuring system or in the installation,
a flashing “INFO” will appear in the display whilst the error exists. The “INFO” panel will automatically
disappear when the error has been corrected.
An Info Event Logger indicates how many times the info code has been changed.
The info logger stores the latest 50 changes, of which 36 can be displayed.
55810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Voltage supply
MULTICAL® 402 is available with 2 x AA battery supply (up to a lifetime of 6 years), D-cell battery (up to
a lifetime of 16 years incl. Wireless M-Bus), 230 VAC mains module or 24 VAC mains module. The sup-
ply modules are exchangeable without breaking the verification seal.
Plug-in modules
Plug-in modules can be added to MULTICAL® 402 such as
•	 Data
•	 M-Bus
•	 Wireless M-Bus
•	 Radio
In this way the meter can adapt to various applications and data reading methods.
Programming and verification
METERTOOL for MULTICAL® 402 is a Windows® -based software which includes all facilities for calcula-
tor programming. If the software is used together with VERIFICATION EQUIPMENT for MULTICAL® 402,
the calculator can be tested and verified.
Data logging interval Data logging depth Logged value
Yearly logger 15 years Counter (as seen on the display)
Monthly logger 36 months Counter (as seen on the display)
Daily logger 460 days Consumption (increase)/day
Info logger
50 events
(36 events can be shown in the display)
Info code and date
Data loggers
MULTICAL® 402 contains a permanent memory (EEPROM), where the results of a number of various data
loggers are stored.
The meter contains the following data loggers:
Calculator functions
6 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Pulse outputs CE and CV
MULTICAL® 402 has pulse outputs for energy and volume pulses
respectively. CE on terminals 16-17 releases one pulse per least sig-
nificant digit of the energy count in the display and CV on terminals
18-19 releases one pulse per least significant digit of the volume
count in the display.
If a higher resolution of pulse outputs is required, a CCC code with
high resolution must be selected.
Pulse inputs VA and VB
MULTICAL® 402 has two extra pulse inputs, VA and VB, to collect and
accumulate pulses remotely, e.g from cold-water meters and electric-
ity meters. The pulse inputs are physically placed on the plug-in
modules.
The pulse inputs VA and VB function independently of the other
inputs/outputs.
Pulse outputs and pulse inputs of the modules
Tariff functions
MULTICAL® 402 has 2 extra registers TA2 and TA3 to accumulate
energy parallelly to the main register based on a programmed tariff
condition. No matter which tariff type you select the tariff registers
will be displayed as TA2 and TA3.
The main register is always accumulated, irrespective of the selected
tariff function, as it is considered the legal billing register.
Tariff conditions TL2 and TL3 are monitored before each integration.
If the tariff conditions are fulfilled, the consumed heat energy is ac-
cumulated in either TA2 or TA3, as well as the main register.
Calculator functions
75810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Cabinet design
Power supply/battery
Terminals for temperature sen-
sors
Buttons for changing
display
Under the cover the calcula-
tor’s electronics are sealed
by a verification label (secu-
rity seal)
Plug-in module
Plug for power supply/
battery
8 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
EU directives	
– Measuring Instrument Directive
– Low Voltage Directive	
– Electromagnetic Compatibity Directive
– Pressurised Equipment Directive
Standard	 prEN 1434:2009
Heat meter	
– Approval	 DK-0200-MI004-013
– Temperature range			 θ: 	 2°C...160°C
– Differential range			 ∆Θ:	3K...150K
Cooling meter	
– Temperature range			 θ:	2°C...50°C
– Differential range			 ∆Θ:	3K...30K
Accuracy				
– Calculator	 EC
±(0.5 + ∆Θmin
/∆Θ)%
– Flow sensor	 Eq
±(2 + 0.02 qr
/qi
), but not more than ±5%
Dynamic range qi
:qp
	1:100
Temperature sensors	
– Type 402-V				 Pt100 – EN 60 751, 2-wire connection
– Type 402-W/T				 Pt500 – EN 60 751, 2-wire connection
EN 1434 designation	 Environmental class A
MID designation	
– Mechanical environment 	 class M1
– Electromagnetic environment 	 class E1
Non condensing, closed location (indoor installation), 5…55°C
Approved meter data
Type number Nom.
flow
qp
[m³/h]
Min.
flow
qi
[m³/h]
Max.
flow
qs
[m³/h]
Min.
cut off
[l/h]
Pressure
loss
∆p @ qp
[bar]
Connection
meter
Length
[mm]
402xxxxxx1xxx 0.6 0,006 1,2 3 0.04 G¾B 110
402xxxxxx3xxx 0.6 0,006 1,2 3 0.04 G1B 190
402xxxxxx4xxx 1.5 0,015 3,0 3 0.25 G¾B 110
402xxxxxx5xxx 1.5 0,015 3,0 3 0.25 G¾B 165
402xxxxxx7xxx 1.5 0,015 3,0 3 0.25 G1B 130
402xxxxxx9xxx 1.5 0,015 3,0 3 0.25 G1B 190
402xxxxxxAxxx 2.5 0,025 5,0 5 0.03 G1B 130
402xxxxxxBxxx 2.5 0,025 5,0 5 0.03 G1B 190
402xxxxxxDxxx 3.5 0,035 7,0 7 0.07 G5/4B 260
402xxxxxxFxxx 6.0 0,06 12 12 0.19 G5/4B 260
402xxxxxxGxxx 6.0 0,06 12 12 0.19 DN25 260
402xxxxxxHxxx 10 0,1 20 20 0.06 G2B 300
402xxxxxxJxxx 10 0,1 20 20 0.06 DN40 300
402xxxxxxKxxx 15 0,15 30 30 0.14 DN50 270
The stated minimum temperatures
apply to the type approval only. The
meter has no cutoff for low tem-
perature and thus measures as low
temperatures as 0.01°C and 0.01 K.
95810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Replacement
interval
3.65 VDC,
D-celle lithium
3.65 VDC,
2xAA cell lithium
Mounted
on wall
16 years @ tBAT
< 30°C 6 years @ tBAT
< 30°C
Mounted on
the flow sensor
12 years @ tBAT
< 40°C 5 years @ tBAT
< 40°C
10 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Calculator data
Typical accuracy	
– Calculator 	 EC
±(0.15 + 2/∆Θ)%	
– Sensor set 	 ET
±(0.4 + 4/∆Θ)%
Display	 LCD – 7 (8) digits with a digit heigth of 7.6 mm
Resolution	 9999.999 – 99999.99 – 999999.9 – 9999999
Energy units	 MWh – kWh – GJ – Gcal
Data logger (Eeprom)	 460 days, 36 months, 15 years, 50 info codes
Clock/calendar	 Clock, calendar, leap-year compensation, target date
Data communication	 KMP protocol with CRC16 used for optical communication and for
base modules
Power in temperature sensors	 < 10 µW RMS
sensors
Supply voltage 	 3.6 VDC ± 0.1 VDC
Battery
	
	
The replacement interval is reduced by using data modules, at
frequent data communication and at high ambient temperature.
Mains supply 	 230 VAC +15/-30%, 50/60 Hz
24 VAC ±50%, 50/60 Hz
Insulation voltage	 4 kV
Power supply	 < 1 W
Back-up supply	 Integral super-cap eliminates operational stop-down due to short-
term power cuts.
EMC data	 Meets EN 1434 class A (MID class E1)
Electrical data
115810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Electrical data
Temperature measurement
T1
Flow
temperature
T2
Return
temperature
∆Θ(T1-T2)
Heat
metering
∆Θ(T2-T1)
Cooling
metering
402-V 2-W
Pt100
Measuring
range
0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00K
402-W/T 2-W
Pt500
Measuring
range
0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00K
Pulse inputs VA and VB
VA: 65-66 and VB: 67-68 via module
Water meter connection
FF(VA) and GG(VB) = 01…40
Pulse input 680 kΩ pull-up to 3.6 V
Pulse ON < 0.4 V for > 30 msec.
Pulse OFF > 2.5 V for > 1.1 sec.
Pulse frequency < 0.5 Hz
Electrical isolation No
Max. cable length 25 m
Requirements to external contact Leakage current at function open < 1 µA
Pulse outputs CE and CV
Energy (16-17) Volume (18-19) via module
The pulse outputs can be configured
for heat or cooling energy
Type Open collector (OB)
Pulse length Programmable 32 msec. or 100 msec.
External voltage 5…30 VDC
Current 1…10 mA
Residual voltage UCE
≈ 1 V at 10 mA
Electrical isolation 2 kV
Max. cable length 25 m
12 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Environment class	 Meets EN 1434 class A (MID class E1)
Ambient temperature	 5…55°C, non condensing, closed location (indoor installation)
Protection class	
– 	Calculator	 IP54
– Flow sensor	 IP65
Media temperature	
– Heat meters	 402-V/W: 15…130°C	
– Cooling meters	 402-T: 2…50°C	
– Heat/Cooling meters	 402-T: 2…130°C 	
– Media in flow sensor	 Water
Storage temperature	 -20…60°C (drained flow meter)
Pressure step (with thread)	 PN16
Pressure step (with flanges)	 PN25
Weight	 From 1.8 to 12 kg depending on the size of the flowpart
Flow sensor cable	 1.5 m (the cable cannot be removed)
Connection cables	 ø3.5…6 mm
Supply cable	 ø5…10 mm
Mechanical data
At medium temperatures over 90°C
in the flow sensor, we recommend
using flange meters and mounting the
calculator on the wall.
135810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Wetted parts	
Housing, gland	 DZR brass (dezincification resistant)
Housing, flange	 Stainless steel, W.no. 1.4308
Transducers	 Stainless steel, W.no. 1.4401
Gaskets	EPDM
Measuring tube	 Thermoplastic, PES 30% GF
Reflectors	 Thermoplastic, PES 30% GF and Stainless steel, W.no. 1.4301
Flow sensor housing
Top/wall brackets	 Thermoplastic, PC 20% GF
Calculator casing
Top cover	 Thermoplastic, PC
Base unit	 Thermoplastic, ABS with TPE gaskets (thermoplastic elastomer)
Internal cover	 Thermoplastic, ABS
Flow sensor cable	 Silicone cable with internal teflon insulation
Materials
14 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Accuracy
Sub-units of the heat meter MPE according to EN 1434-1 MULTICAL® 402, typical accuracy
Flow sensor Ef = ±(2 + 0.02 qp/q) % Ef = ±(1 + 0.01 qp/q) %
Calculator Ec = ±(0.5 +∆Θmin
/∆Θ) % Ec = ±(0.15 + 2/∆Θ) %
Sensor set Et = ±(0.5 + 3∆Θmin
/∆Θ) % Et = ±(0.4 + 4/∆Θ) %
-6,0
-4,0
-2,0
0,0
2,0
4,0
6,0
0,01 0,10 1,00 10,00
q [m³/h]
Tol[%]
Ec+Et+Ef (EN)
Ec+Et+Ef (Typ)
MULTICAL ® 402 qp 1,5 m³/h @ ∆Θ 30KMULTICAL® 402 qp
1.5 m³/h @ ∆Θ 30K
Order specifications
155810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Sensor connection
Pt100 V
Pt500 W
Pt500 (with condensation protected flow sensor for cooling) T
Modules
No module 00
Data + 2 pulse inputs (VA, VB) 10
Data + 2 pulse outputs (CE, CV) 11
M-Bus + 2 pulse inputs (VA, VB) 20
M-Bus + 2 pulse outputs (CE, CV) 21
M-Bus + 2 pulse inputs (VA, VB), MULTICAL® III Data Package 29
Wireless M-Bus, EU, 868 MHz, Mode C1 30
Wireless M-Bus, EU, 868 MHz, Mode C1 (Individual key), alternative registers, +VA, VB 35
Wireless M-Bus, EU, 868 MHz, Mode T1 (Common key) 37
Radio, EU, 434 MHz, int. ant., NET0 40
Radio, EU, 434 MHz, int. ant., NET1 41
Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse inputs (VA, VB) 42
Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse outputs (CE, CV) 43
Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse inputs (VA, VB) 44
Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse outputs (CE, CV) 45
Radio, SE, 444 MHz, int. ant., NET0 + 2 pulse inputs (VA, VB) 50
Radio, SE, 444 MHz, int. ant., NET1 + 2 pulse inputs (VA, VB) 52
Radio, SE, 444 MHz, ext. ant., NET0 + 2 pulse inputs (VA, VB) 54
Radio, SE, 444 MHz, ext. ant., NET1 + 2 pulse inputs (VA, VB) 56
Supply
No module 0
Battery, 2 x AA 1
Battery, D-cell 2
230 VAC supply module 7
24 VAC supply module 8
Pt500 sensor set
No sensor set 00
Pocket sensor set with 1.5 m cable 0A
Pocket sensor set with 3.0 m cable 0B
Short direct sensor set with 1.5 m cable 0F
Short direct sensor set with 3.0 m cable 0G
Flow sensor
qp [m³/h] Connection Length [mm]
0.6 G¾B (R½) 110 1
0.6 G1B (R¾) 190 3
1.5 G¾B (R½) 110 4
1.5 G¾B (R½) 165 5
1.5 G1B (R¾) 130 7
1.5 G1B (R¾) 190 9
2.5 G1B (R¾) 130 A
2.5 G1B (R¾) 190 B
3.5 G5/4B (R1) 260 D
6.0 G5/4B (R1) 260 F
6.0 DN25 260 G
10 G2B (R1½) 300 H
10 DN40 300 J
15 DN50 270 K
Meter type
Heat meter (MID: module B+D) 2
Heat meter (MID: module B+D, only MULTICAL® 402 T) 3
Heat meter 4
Cooling meter (only MULTICAL® 402 T) 5
Heat/cooling meter (only MULTICAL® 402 T) 6
Volume meter (hot) 7
Volume meter (cold, only MULTICAL® 402 T) 8
Energy meter 9
Country code (language on lable etc.) XX
MULTICAL® 402 Type 402          
Dimentional sketches
Mechanical measurements of the electronics unit
Flow sensor with G¾ and G1 thread connection. Thread ISO 228-1.
Thread L M H2 A B1 B2 H1 Approx.
weight [kg]
G¾ 110 L/2 89 10.5 50.5 35 48.5 1.4
G1 (qp 1.5) 130 L/2 89 20.5 50.5 35 48.5 1.5
G1 (qp 2.5) 130 L/2 89 20.5 50.5 35 48.5 1.4
G¾ 165 L/2 89 20.5 50.5 35 48.5 1.8
G1 (qp 1.5) 190 L/2 89 20.5 50.5 35 48.5 2.0
G1 (qp 2.5) 190 L/2 89 20.5 50.5 35 48.5 1.9
Weight includes a 3 m Short direct sensor set, but is excluding packing.
16 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Dimentional sketches
Flow sensor with G5/4 and G2 thread connection. Thread ISO 228-1.
Thread L M H2 A B1 B2 H1 Approx.
weight [kg]
G5/4 260 L/2 88.7 17 50.5 22 48.5 2.9
G2 300 L/2 88.7 21 50.5 31 48.5 5.1
Weight includes a 3 m Short direct sensor set, but is excluding packing.
175810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Weight includes a 3 m short direct sensor set, but is excluding packing.
Flow sensor with DN25 to DN50 flange connection. Flange EN 1092, PN25.
Dimentional sketches
Nom.
diameter
Bolts Approx. weight
L M H2 D H k Number Thread d2 [kg]
DN25 260 L/2 92.5 115 106 85 4 M12 14 5.6
DN40 300 L/2 92.5 150 136 110 4 M16 18 8.9
DN50 270 155 92.5 165 145 125 4 M16 18 10.7
18 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Pressure loss
MULTICAL
0,01
0,1
1
0,1 1 10 100
Flow [m³/h]
∆p[bar]
A B C
∆p MULTICAL® 402
Graph qp
[m³/h]
Nom. diameter
[mm]
kv Q@0,25 bar
[m³/h]
A 0.6 & 1.5 DN15 & DN20 3 1.5
B 2.5 & 3.5 & 6 DN20 & DN25 13.5 6.8
C 10 & 15 DN40 & DN50 43 21.7
195810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T
Type number	 Description	 	
402-000-1000-000	 Battery module 2 pcs. AA-cell
402-000-2000-000	 D-cell battery
402-000-7000-000	 230 VAC supply module
402-000-8000-000	 24 VAC supply module
66-99-097	 USB cable with galvanic separation
66-99-099	 Infra-red optical reading head with USB plug
66-99-102	 Infra-red optical reading head RS232 with D-sub 9F
66-99-106	 Data cable RS232, D-sub 9F
66-99-108 	 Pc-Interface cable RS232 for MULTICAL®
66-99-372	 Pt500 (Heat) Verification Equipment for MULTICAL® 402
(used with METERTOOL)
66-99-373	 Pt500 (Cooling) Verification Equipment for MULTICAL® 402
(used with METERTOOL)
66-99-712	 METERTOOL for MULTICAL® 402
66-99-713	 METERTOOL LogView for MULTICAL® 402
Accessories
Glands including gaskets (PN16)
Gaskets
Size Nipple Union Type No. 2 pcs
DN15 R½ G¾ 65-61-323
DN20 R¾ G1 65-61-324
DN25 R1 G5/4 65-61-325
DN40 R1½ G2 65-61-315
	
For glands For flange meters PN25
Size (Union) Type No. Size Type No.
G¾ 2210-061 DN20 2210-147
G1 2210-062 DN25 2210-133
G5/4 2210-063 DN40 2210-132
G2 2210-065 DN50 2210-099
20 5810725_F1_GB_01.2013
MULTICAL® 402
D A T A S H E E T

Weitere ähnliche Inhalte

Was ist angesagt?

Sontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - BrochureSontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - BrochureThorne & Derrick UK
 
MID Heat Metering For RHI Report
MID Heat Metering For RHI ReportMID Heat Metering For RHI Report
MID Heat Metering For RHI ReportThorne & Derrick UK
 
Heat Meters - Sontex Superstatic 749 - Spec Sheet
Heat Meters - Sontex Superstatic 749 - Spec SheetHeat Meters - Sontex Superstatic 749 - Spec Sheet
Heat Meters - Sontex Superstatic 749 - Spec SheetThorne & Derrick UK
 
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...Thorne & Derrick UK
 
Dual technology dust measurement instrument
Dual technology dust measurement instrumentDual technology dust measurement instrument
Dual technology dust measurement instrumentClassic Controls, Inc.
 
Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Classic Controls, Inc.
 
Sensus PolluStat E Heat Meter - Spec Sheet
Sensus PolluStat E Heat Meter - Spec SheetSensus PolluStat E Heat Meter - Spec Sheet
Sensus PolluStat E Heat Meter - Spec SheetThorne & Derrick UK
 
Process Gas Chromatograph for Industrial Use
Process Gas Chromatograph for Industrial UseProcess Gas Chromatograph for Industrial Use
Process Gas Chromatograph for Industrial UseClassic Controls, Inc.
 
Process Digital Bargraph Display for Industrial Control and Automation
Process Digital Bargraph Display for Industrial Control and AutomationProcess Digital Bargraph Display for Industrial Control and Automation
Process Digital Bargraph Display for Industrial Control and AutomationClassic Controls, Inc.
 
New Thermal Mass Flow Meter From Fox Instruments
New Thermal Mass Flow Meter From Fox InstrumentsNew Thermal Mass Flow Meter From Fox Instruments
New Thermal Mass Flow Meter From Fox InstrumentsClassic Controls, Inc.
 
Combination magnetic and guided wave radar liquid level indicator
Combination magnetic and guided wave radar liquid level indicatorCombination magnetic and guided wave radar liquid level indicator
Combination magnetic and guided wave radar liquid level indicatorClassic Controls, Inc.
 
Nelson Easy Heat Self Regulating Heater Cables - Product Catalogue
Nelson Easy Heat Self Regulating Heater Cables - Product CatalogueNelson Easy Heat Self Regulating Heater Cables - Product Catalogue
Nelson Easy Heat Self Regulating Heater Cables - Product CatalogueThorne & Derrick UK
 
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chillerEeu SC
 
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...ENVIMART
 
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...ENVIMART
 
Digital Vortex Flowmeters From Yokogawa
Digital Vortex Flowmeters From YokogawaDigital Vortex Flowmeters From Yokogawa
Digital Vortex Flowmeters From YokogawaClassic Controls, Inc.
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlClassic Controls, Inc.
 

Was ist angesagt? (20)

Sontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - BrochureSontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
 
MID Heat Metering For RHI Report
MID Heat Metering For RHI ReportMID Heat Metering For RHI Report
MID Heat Metering For RHI Report
 
Heat Meters - Sontex Superstatic 749 - Spec Sheet
Heat Meters - Sontex Superstatic 749 - Spec SheetHeat Meters - Sontex Superstatic 749 - Spec Sheet
Heat Meters - Sontex Superstatic 749 - Spec Sheet
 
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
 
Dual technology dust measurement instrument
Dual technology dust measurement instrumentDual technology dust measurement instrument
Dual technology dust measurement instrument
 
Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...
 
Sensus PolluStat E Heat Meter - Spec Sheet
Sensus PolluStat E Heat Meter - Spec SheetSensus PolluStat E Heat Meter - Spec Sheet
Sensus PolluStat E Heat Meter - Spec Sheet
 
Sensus PolluCom E Heat Meter
Sensus PolluCom E Heat MeterSensus PolluCom E Heat Meter
Sensus PolluCom E Heat Meter
 
AXIS SKS-3 RHI Heat Meter
AXIS SKS-3 RHI Heat MeterAXIS SKS-3 RHI Heat Meter
AXIS SKS-3 RHI Heat Meter
 
Process Gas Chromatograph for Industrial Use
Process Gas Chromatograph for Industrial UseProcess Gas Chromatograph for Industrial Use
Process Gas Chromatograph for Industrial Use
 
Process Digital Bargraph Display for Industrial Control and Automation
Process Digital Bargraph Display for Industrial Control and AutomationProcess Digital Bargraph Display for Industrial Control and Automation
Process Digital Bargraph Display for Industrial Control and Automation
 
New Thermal Mass Flow Meter From Fox Instruments
New Thermal Mass Flow Meter From Fox InstrumentsNew Thermal Mass Flow Meter From Fox Instruments
New Thermal Mass Flow Meter From Fox Instruments
 
Combination magnetic and guided wave radar liquid level indicator
Combination magnetic and guided wave radar liquid level indicatorCombination magnetic and guided wave radar liquid level indicator
Combination magnetic and guided wave radar liquid level indicator
 
Nelson Easy Heat Self Regulating Heater Cables - Product Catalogue
Nelson Easy Heat Self Regulating Heater Cables - Product CatalogueNelson Easy Heat Self Regulating Heater Cables - Product Catalogue
Nelson Easy Heat Self Regulating Heater Cables - Product Catalogue
 
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chiller
 
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
 
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
 
Digital Vortex Flowmeters From Yokogawa
Digital Vortex Flowmeters From YokogawaDigital Vortex Flowmeters From Yokogawa
Digital Vortex Flowmeters From Yokogawa
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process Control
 

Andere mochten auch

VuHeat Ultrasonic Heat Meters Datasheets
VuHeat Ultrasonic Heat Meters DatasheetsVuHeat Ultrasonic Heat Meters Datasheets
VuHeat Ultrasonic Heat Meters DatasheetsBell Flow Systems
 
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetDrager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager PIR 7200 Fixed Gas Detector - Spec Sheet
Drager PIR 7200 Fixed Gas Detector - Spec SheetDrager PIR 7200 Fixed Gas Detector - Spec Sheet
Drager PIR 7200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - Brochure
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - BrochureExheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - Brochure
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - BrochureThorne & Derrick UK
 
Itron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - EnglishItron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - EnglishThorne & Derrick UK
 
Itron cf echo ii ultrasonic heat meter brochure - english
Itron cf echo ii ultrasonic heat meter   brochure - englishItron cf echo ii ultrasonic heat meter   brochure - english
Itron cf echo ii ultrasonic heat meter brochure - englishThorne & Derrick UK
 
Dräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureDräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureThorne & Derrick UK
 
Are You Ready to Wear the Data Rockstar Shirt?
Are You Ready to Wear the Data Rockstar Shirt?Are You Ready to Wear the Data Rockstar Shirt?
Are You Ready to Wear the Data Rockstar Shirt?Joshua Tapley
 
Design in Tech Report 2017
Design in Tech Report 2017Design in Tech Report 2017
Design in Tech Report 2017John Maeda
 

Andere mochten auch (10)

Rhi Scheme Regulations 2011
Rhi Scheme Regulations 2011Rhi Scheme Regulations 2011
Rhi Scheme Regulations 2011
 
VuHeat Ultrasonic Heat Meters Datasheets
VuHeat Ultrasonic Heat Meters DatasheetsVuHeat Ultrasonic Heat Meters Datasheets
VuHeat Ultrasonic Heat Meters Datasheets
 
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec SheetDrager Polytron 3000 Fixed Gas Detector - Spec Sheet
Drager Polytron 3000 Fixed Gas Detector - Spec Sheet
 
Drager PIR 7200 Fixed Gas Detector - Spec Sheet
Drager PIR 7200 Fixed Gas Detector - Spec SheetDrager PIR 7200 Fixed Gas Detector - Spec Sheet
Drager PIR 7200 Fixed Gas Detector - Spec Sheet
 
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - Brochure
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - BrochureExheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - Brochure
Exheat Flameproof Hazardous Area Heaters, Zone 1 & Zone 2 - Brochure
 
Itron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - EnglishItron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - English
 
Itron cf echo ii ultrasonic heat meter brochure - english
Itron cf echo ii ultrasonic heat meter   brochure - englishItron cf echo ii ultrasonic heat meter   brochure - english
Itron cf echo ii ultrasonic heat meter brochure - english
 
Dräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureDräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - Brochure
 
Are You Ready to Wear the Data Rockstar Shirt?
Are You Ready to Wear the Data Rockstar Shirt?Are You Ready to Wear the Data Rockstar Shirt?
Are You Ready to Wear the Data Rockstar Shirt?
 
Design in Tech Report 2017
Design in Tech Report 2017Design in Tech Report 2017
Design in Tech Report 2017
 

Ähnlich wie Kamstrup RHI Compliant Heat Meters & Thermal Energy Measurement - Multical 402 Compact Energy Meter - Spec Sheet

Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...
Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...
Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...Thorne & Derrick UK
 
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONIC
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONICKLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONIC
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONICdanto .
 
Iskra Electrical Measuring Instruments
Iskra Electrical Measuring InstrumentsIskra Electrical Measuring Instruments
Iskra Electrical Measuring InstrumentsMinka Grdesic
 
A BTU Meter that saves energy (chiller apication and heat transfer application
A BTU Meter that saves energy (chiller apication and heat transfer applicationA BTU Meter that saves energy (chiller apication and heat transfer application
A BTU Meter that saves energy (chiller apication and heat transfer applicationManasMicrosystems
 
Electrical measuring-instruments
Electrical measuring-instrumentsElectrical measuring-instruments
Electrical measuring-instrumentsBrit4
 
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014Sheikh Imran
 
Heat Calculator for Chilled and Hot Water Systems
Heat Calculator for Chilled and Hot Water SystemsHeat Calculator for Chilled and Hot Water Systems
Heat Calculator for Chilled and Hot Water SystemsMiller Energy, Inc.
 
Energy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringEnergy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringClassic Controls, Inc.
 
MPC of TWT based Transmitter
MPC of TWT based TransmitterMPC of TWT based Transmitter
MPC of TWT based TransmitterAbhishek Sutrave
 
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014Sheikh Imran
 
Pm5000 series cat
Pm5000 series catPm5000 series cat
Pm5000 series catMatt Tudge
 
Iskra MC 640 Multifunction Meter Datasheet Manual
Iskra MC 640 Multifunction Meter Datasheet ManualIskra MC 640 Multifunction Meter Datasheet Manual
Iskra MC 640 Multifunction Meter Datasheet ManualAngus Sankaran
 
Digital Alarm Clock (IC-TMS-8560)
Digital Alarm Clock (IC-TMS-8560)Digital Alarm Clock (IC-TMS-8560)
Digital Alarm Clock (IC-TMS-8560)Chintan Patel
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Beeteco
 
dtsd1352-manual.pdf
dtsd1352-manual.pdfdtsd1352-manual.pdf
dtsd1352-manual.pdfacrelenergy
 
Itron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - englishItron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - englishThorne & Derrick UK
 
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamikaKatalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamikaPT. Tridinamika Jaya Instrument
 

Ähnlich wie Kamstrup RHI Compliant Heat Meters & Thermal Energy Measurement - Multical 402 Compact Energy Meter - Spec Sheet (20)

Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...
Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...
Kamstrup multical 801 heat meter, ultrasonic energy meter, heating & cooling ...
 
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONIC
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONICKLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONIC
KLEA( ENERGY ANALYZER ) & ECRAS ( MULTIMETER ) -KLEMSAN ELECTRIC ELECTRONIC
 
Iskra Electrical Measuring Instruments
Iskra Electrical Measuring InstrumentsIskra Electrical Measuring Instruments
Iskra Electrical Measuring Instruments
 
A BTU Meter that saves energy (chiller apication and heat transfer application
A BTU Meter that saves energy (chiller apication and heat transfer applicationA BTU Meter that saves energy (chiller apication and heat transfer application
A BTU Meter that saves energy (chiller apication and heat transfer application
 
Electrical measuring-instruments
Electrical measuring-instrumentsElectrical measuring-instruments
Electrical measuring-instruments
 
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014
Diwan Annexure Starter panels Presentation Rev-1 Dt16-11-2014
 
Heat Calculator for Chilled and Hot Water Systems
Heat Calculator for Chilled and Hot Water SystemsHeat Calculator for Chilled and Hot Water Systems
Heat Calculator for Chilled and Hot Water Systems
 
Energy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringEnergy Calculator for Usage Monitoring
Energy Calculator for Usage Monitoring
 
MPC of TWT based Transmitter
MPC of TWT based TransmitterMPC of TWT based Transmitter
MPC of TWT based Transmitter
 
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014
Amiri Guard Starter panels Presentation Rev-1 Dt16-11-2014
 
Current Transformer CT Meter
Current Transformer CT MeterCurrent Transformer CT Meter
Current Transformer CT Meter
 
Pm5000 series cat
Pm5000 series catPm5000 series cat
Pm5000 series cat
 
Iskra MC 640 Multifunction Meter Datasheet Manual
Iskra MC 640 Multifunction Meter Datasheet ManualIskra MC 640 Multifunction Meter Datasheet Manual
Iskra MC 640 Multifunction Meter Datasheet Manual
 
Hioki data logger selection
Hioki data logger selectionHioki data logger selection
Hioki data logger selection
 
Digital Alarm Clock (IC-TMS-8560)
Digital Alarm Clock (IC-TMS-8560)Digital Alarm Clock (IC-TMS-8560)
Digital Alarm Clock (IC-TMS-8560)
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)
 
dtsd1352-manual.pdf
dtsd1352-manual.pdfdtsd1352-manual.pdf
dtsd1352-manual.pdf
 
Itron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - englishItron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - english
 
Riello aros-central-transformer-based-solar-inverters
Riello aros-central-transformer-based-solar-invertersRiello aros-central-transformer-based-solar-inverters
Riello aros-central-transformer-based-solar-inverters
 
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamikaKatalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
Katalog produk chauvin arnoux power quality analyser ca8336 by tridinamika
 

Mehr von Thorne & Derrick UK

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Thorne & Derrick UK
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Thorne & Derrick UK
 
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Thorne & Derrick UK
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureThorne & Derrick UK
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...Thorne & Derrick UK
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thorne & Derrick UK
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueThorne & Derrick UK
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsThorne & Derrick UK
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueThorne & Derrick UK
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Thorne & Derrick UK
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CableThorne & Derrick UK
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Thorne & Derrick UK
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureThorne & Derrick UK
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnThorne & Derrick UK
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewThorne & Derrick UK
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Thorne & Derrick UK
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureThorne & Derrick UK
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Thorne & Derrick UK
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureThorne & Derrick UK
 

Mehr von Thorne & Derrick UK (20)

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
 
Dart Valley Systems Catalogue
Dart Valley Systems CatalogueDart Valley Systems Catalogue
Dart Valley Systems Catalogue
 
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration Instruments
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - Catalogue
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection Cable
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate Brochure
 

Kürzlich hochgeladen

Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menzaictsugar
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessSeta Wicaksana
 
Cyber Security Training in Office Environment
Cyber Security Training in Office EnvironmentCyber Security Training in Office Environment
Cyber Security Training in Office Environmentelijahj01012
 
Church Building Grants To Assist With New Construction, Additions, And Restor...
Church Building Grants To Assist With New Construction, Additions, And Restor...Church Building Grants To Assist With New Construction, Additions, And Restor...
Church Building Grants To Assist With New Construction, Additions, And Restor...Americas Got Grants
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Pereraictsugar
 
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptx
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptxThe-Ethical-issues-ghhhhhhhhjof-Byjus.pptx
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptxmbikashkanyari
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...ictsugar
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Seta Wicaksana
 
8447779800, Low rate Call girls in Rohini Delhi NCR
8447779800, Low rate Call girls in Rohini Delhi NCR8447779800, Low rate Call girls in Rohini Delhi NCR
8447779800, Low rate Call girls in Rohini Delhi NCRashishs7044
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?Olivia Kresic
 
Fordham -How effective decision-making is within the IT department - Analysis...
Fordham -How effective decision-making is within the IT department - Analysis...Fordham -How effective decision-making is within the IT department - Analysis...
Fordham -How effective decision-making is within the IT department - Analysis...Peter Ward
 
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!Doge Mining Website
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCRashishs7044
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africaictsugar
 
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckPitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckHajeJanKamps
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy Verified Accounts
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607dollysharma2066
 

Kürzlich hochgeladen (20)

Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful Business
 
Cyber Security Training in Office Environment
Cyber Security Training in Office EnvironmentCyber Security Training in Office Environment
Cyber Security Training in Office Environment
 
Church Building Grants To Assist With New Construction, Additions, And Restor...
Church Building Grants To Assist With New Construction, Additions, And Restor...Church Building Grants To Assist With New Construction, Additions, And Restor...
Church Building Grants To Assist With New Construction, Additions, And Restor...
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Perera
 
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptx
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptxThe-Ethical-issues-ghhhhhhhhjof-Byjus.pptx
The-Ethical-issues-ghhhhhhhhjof-Byjus.pptx
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
 
Call Us ➥9319373153▻Call Girls In North Goa
Call Us ➥9319373153▻Call Girls In North GoaCall Us ➥9319373153▻Call Girls In North Goa
Call Us ➥9319373153▻Call Girls In North Goa
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...
 
8447779800, Low rate Call girls in Rohini Delhi NCR
8447779800, Low rate Call girls in Rohini Delhi NCR8447779800, Low rate Call girls in Rohini Delhi NCR
8447779800, Low rate Call girls in Rohini Delhi NCR
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?
 
Fordham -How effective decision-making is within the IT department - Analysis...
Fordham -How effective decision-making is within the IT department - Analysis...Fordham -How effective decision-making is within the IT department - Analysis...
Fordham -How effective decision-making is within the IT department - Analysis...
 
Corporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information TechnologyCorporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information Technology
 
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!
Unlocking the Future: Explore Web 3.0 Workshop to Start Earning Today!
 
No-1 Call Girls In Goa 93193 VIP 73153 Escort service In North Goa Panaji, Ca...
No-1 Call Girls In Goa 93193 VIP 73153 Escort service In North Goa Panaji, Ca...No-1 Call Girls In Goa 93193 VIP 73153 Escort service In North Goa Panaji, Ca...
No-1 Call Girls In Goa 93193 VIP 73153 Escort service In North Goa Panaji, Ca...
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africa
 
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckPitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail Accounts
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
 

Kamstrup RHI Compliant Heat Meters & Thermal Energy Measurement - Multical 402 Compact Energy Meter - Spec Sheet

  • 1. Industrivej 28, Stilling · 8660 Skanderborg · Denmark · Tel: +45 89 93 10 00 · Fax: +45 89 93 10 01 · info@kamstrup.com · www.kamstrup.com MULTICAL® 402 Application MULTICAL® 402 is the compact ultrasonic meter which registers the exact consumption due to its supreme measuring accuracy. The meter is maintenance-free and has a long lifetime which guarantees minimum yearly operating costs. MULTICAL® 402 is used for heat, cooling and combined heat /cool- ing measurement in all water-based systems with temperatures from 2 to 160°C. The meter has been developed for measurement of energy consump- tion in family and multiple occupancy housing, housing associations, blocks of flats and small industry. Functionality MULTICAL® 402 consists of calcula- tor, flow sensor and two temperature sensors and is simple to install, read and verify. Our flow sensor range for MULTICAL® 402 comprises of the sizes 0.6 – 15 m³/h, and the supply options are 230 or 24 VAC mains module, 2xAA-cell battery, or D-cell battery with up to 16 years’ lifetime. MULTICAL® 402 is fitted with a connector for the supply and thus, it is easy to change battery or mains supply. By means of the calculator’s two front keys it is easy to adjust date and time or reset operating hour counter and info-event counter. Furthermore, the keys can be used to display log data, incl. yearly or monthly logger. MULTICAL® 402 receives pulses from up to two connected hot or cold water meters and carries out remote accumulation of energy and volume via pulse outputs. If you change from pulse input to pulse output, the meter is automatically configured for pulse inputs and pulse outputs respectively – without manual reconfiguration. Wireless reading The meter is remotely read via Wire- less M-Bus or radio module. Con- sumption data is read, saved and transferred by means of the USB Meter Reader. Furthermore, radio can be read by means of a hand-held terminal or form part of a Kamstrup radio network. The transferred data is used for individual billing, consumption analysis and/or energy optimisation. Compact meter for heat and cooling with maximum functionality D A T A S H E E T „„ Up to 16 years’ battery lifetime „„ Set/reset function „„ Pulse outputs for energy and volume „„ Pulse inputs for up to two water meters „„ Wireless reading via Wireless M-Bus or radio 0200M12 MID-2004/22/EC 22.52 05.04PTB
  • 2. 2 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Content Calculator functions 3 Pulse outputs and pulse inputs of the modules 7 Cabinet design 8 Approved meter data 9 Electrical data 10 Mechanical data 12 Materials 13 Accuracy 14 Dimentional sketches 16 Pressure loss 19 Accessories 20
  • 3. Energy calculation MULTICAL® 402 calculates energy based on the formula in EN 1434-1:2004, in which the international temperature scale from 1990 (ITS-90) and the pressure definition of 16 bar is used. The energy calculation can in a simplified way be expressed as: Energy = V x ∆Θ x k. V is the supplied water volume ∆Θ is the temperature difference measured k is the thermal coefficient of water The calculator always calculates energy in [Wh], and then it is converted into the selected measur- ing unit. Application types MULTICAL® 402 operates with four different energy formulas, E1...E9, that are all calculated in parallel in connection with each integration no matter how the meter is configured. The four energy types are calculated as follows: E1=V1(T1-T2)k Heat energy (V1 in flow or return) E3=V1(T2-T1)k Cooling energy (V1 in flow or return) E8=m³xT1 (Flow pipe) E9=m³xT2 (Return pipe) This renders MULTICAL® 402 capable of calculating the heat and cooling energy of most applica- tions, both closed and open systems. All energy types are data logged and can be displayed in-dependent of configuration. Flow measurement MULTICAL® 402 calculates current water flow every 12 seconds or every 4 seconds depending on configuration. Power measurement MULTICAL® 402 calculates current power on the basis of current water flow and the temperature difference measured in connection with the latest integration. Current power is updated in the display every 24 seconds or every 4 seconds depending on configuration. Calculator functions 35810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T E [Wh] = V x ∆Θ x k x 1000 E [kWh] = E [Wh] / 1,000 E [MWh] = E [Wh] / 1,000,000 E [GJ] = E [Wh] / 277,780 E [Gcal] = E [Wh] / 1,163,100
  • 4. The upper push button is used to switch between the primary readings. The consumers typically use the first primary readings in connection with self-reading for bill- ing purposes. The lower push button is used to show secondary informa- tion on the selected primary reading. Min. and max. flow and power MULTICAL® 402 registers minimum and maximum flow and power on a monthly as well as on a yearly basis. The registrations which can be read via data communication include max. and min. flow and power values, all with date indication. All max. and min. values are calculated as largest and smallest aver- age respectively of a number of current flow or power measurements. The average period used for all calculations is selected in the interval 1…1440 min. Temperature measurement MULTICAL® 402 is available in different versions for either Pt100 or Pt500 sensors in a 2-wire version. The measuring circuit includes a high resolution analog/ digital converter with a temperature range of 0,00°C…165,00°C. In addition to current temperatures for the energy calculation average temperatures on a yearly and monthly basis can also be displayed. Display functions MULTICAL® 402 is equipped with a clear LC display including 8 digits, units of measurement and infor- mation panel. In connection with energy and volume readings 7 digits and the units of measurement to match are used, whereas 8 digits are used when e.g. meter number is read. As a starting point the display shows accumulated energy. When the push buttons are activated the display reacts immediately by calling other readings. The display automatically returns to accumulated energy reading 4 minutes after the latest activation of the push buttons. Calculator functions 4 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 5. Info code Description Response time 0 No irrigularities - 1 Supply voltage has been cut off - 4 T2 sensor outside range, short-circuited or cut off < 30 sec. 8 T1 sensor outside range, short-circuited or cut off < 30 sec. 4096 Flow sensor with weak signal or air < 30 sec. 16384 Flow sensor with wrong flow direction < 30 sec. Calculator functions Set/reset function The set/reset function of MULTICAL® 402 makes it possible to change a number of parameters by means of the two buttons on the meter’s front. The following parameters can be changed: • Date • Hour • Input A (preset of register) • Input B (preset of register) • Meter no. of Input A • Meter no. of Input B • Primary M-Bus address • Operating hour counter (reset) • Info-event counter (reset) As the installation seal is broken, the change can only be made by the energy supplier. Info codes MULTICAL® 402 constantly monitors a number of important functions, e.g. power supply, temperature sensors and leakage alarms. Should a serious error occur in the measuring system or in the installation, a flashing “INFO” will appear in the display whilst the error exists. The “INFO” panel will automatically disappear when the error has been corrected. An Info Event Logger indicates how many times the info code has been changed. The info logger stores the latest 50 changes, of which 36 can be displayed. 55810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 6. Voltage supply MULTICAL® 402 is available with 2 x AA battery supply (up to a lifetime of 6 years), D-cell battery (up to a lifetime of 16 years incl. Wireless M-Bus), 230 VAC mains module or 24 VAC mains module. The sup- ply modules are exchangeable without breaking the verification seal. Plug-in modules Plug-in modules can be added to MULTICAL® 402 such as • Data • M-Bus • Wireless M-Bus • Radio In this way the meter can adapt to various applications and data reading methods. Programming and verification METERTOOL for MULTICAL® 402 is a Windows® -based software which includes all facilities for calcula- tor programming. If the software is used together with VERIFICATION EQUIPMENT for MULTICAL® 402, the calculator can be tested and verified. Data logging interval Data logging depth Logged value Yearly logger 15 years Counter (as seen on the display) Monthly logger 36 months Counter (as seen on the display) Daily logger 460 days Consumption (increase)/day Info logger 50 events (36 events can be shown in the display) Info code and date Data loggers MULTICAL® 402 contains a permanent memory (EEPROM), where the results of a number of various data loggers are stored. The meter contains the following data loggers: Calculator functions 6 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 7. Pulse outputs CE and CV MULTICAL® 402 has pulse outputs for energy and volume pulses respectively. CE on terminals 16-17 releases one pulse per least sig- nificant digit of the energy count in the display and CV on terminals 18-19 releases one pulse per least significant digit of the volume count in the display. If a higher resolution of pulse outputs is required, a CCC code with high resolution must be selected. Pulse inputs VA and VB MULTICAL® 402 has two extra pulse inputs, VA and VB, to collect and accumulate pulses remotely, e.g from cold-water meters and electric- ity meters. The pulse inputs are physically placed on the plug-in modules. The pulse inputs VA and VB function independently of the other inputs/outputs. Pulse outputs and pulse inputs of the modules Tariff functions MULTICAL® 402 has 2 extra registers TA2 and TA3 to accumulate energy parallelly to the main register based on a programmed tariff condition. No matter which tariff type you select the tariff registers will be displayed as TA2 and TA3. The main register is always accumulated, irrespective of the selected tariff function, as it is considered the legal billing register. Tariff conditions TL2 and TL3 are monitored before each integration. If the tariff conditions are fulfilled, the consumed heat energy is ac- cumulated in either TA2 or TA3, as well as the main register. Calculator functions 75810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 8. Cabinet design Power supply/battery Terminals for temperature sen- sors Buttons for changing display Under the cover the calcula- tor’s electronics are sealed by a verification label (secu- rity seal) Plug-in module Plug for power supply/ battery 8 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 9. EU directives – Measuring Instrument Directive – Low Voltage Directive – Electromagnetic Compatibity Directive – Pressurised Equipment Directive Standard prEN 1434:2009 Heat meter – Approval DK-0200-MI004-013 – Temperature range θ: 2°C...160°C – Differential range ∆Θ: 3K...150K Cooling meter – Temperature range θ: 2°C...50°C – Differential range ∆Θ: 3K...30K Accuracy – Calculator EC ±(0.5 + ∆Θmin /∆Θ)% – Flow sensor Eq ±(2 + 0.02 qr /qi ), but not more than ±5% Dynamic range qi :qp 1:100 Temperature sensors – Type 402-V Pt100 – EN 60 751, 2-wire connection – Type 402-W/T Pt500 – EN 60 751, 2-wire connection EN 1434 designation Environmental class A MID designation – Mechanical environment class M1 – Electromagnetic environment class E1 Non condensing, closed location (indoor installation), 5…55°C Approved meter data Type number Nom. flow qp [m³/h] Min. flow qi [m³/h] Max. flow qs [m³/h] Min. cut off [l/h] Pressure loss ∆p @ qp [bar] Connection meter Length [mm] 402xxxxxx1xxx 0.6 0,006 1,2 3 0.04 G¾B 110 402xxxxxx3xxx 0.6 0,006 1,2 3 0.04 G1B 190 402xxxxxx4xxx 1.5 0,015 3,0 3 0.25 G¾B 110 402xxxxxx5xxx 1.5 0,015 3,0 3 0.25 G¾B 165 402xxxxxx7xxx 1.5 0,015 3,0 3 0.25 G1B 130 402xxxxxx9xxx 1.5 0,015 3,0 3 0.25 G1B 190 402xxxxxxAxxx 2.5 0,025 5,0 5 0.03 G1B 130 402xxxxxxBxxx 2.5 0,025 5,0 5 0.03 G1B 190 402xxxxxxDxxx 3.5 0,035 7,0 7 0.07 G5/4B 260 402xxxxxxFxxx 6.0 0,06 12 12 0.19 G5/4B 260 402xxxxxxGxxx 6.0 0,06 12 12 0.19 DN25 260 402xxxxxxHxxx 10 0,1 20 20 0.06 G2B 300 402xxxxxxJxxx 10 0,1 20 20 0.06 DN40 300 402xxxxxxKxxx 15 0,15 30 30 0.14 DN50 270 The stated minimum temperatures apply to the type approval only. The meter has no cutoff for low tem- perature and thus measures as low temperatures as 0.01°C and 0.01 K. 95810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 10. Replacement interval 3.65 VDC, D-celle lithium 3.65 VDC, 2xAA cell lithium Mounted on wall 16 years @ tBAT < 30°C 6 years @ tBAT < 30°C Mounted on the flow sensor 12 years @ tBAT < 40°C 5 years @ tBAT < 40°C 10 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Calculator data Typical accuracy – Calculator EC ±(0.15 + 2/∆Θ)% – Sensor set ET ±(0.4 + 4/∆Θ)% Display LCD – 7 (8) digits with a digit heigth of 7.6 mm Resolution 9999.999 – 99999.99 – 999999.9 – 9999999 Energy units MWh – kWh – GJ – Gcal Data logger (Eeprom) 460 days, 36 months, 15 years, 50 info codes Clock/calendar Clock, calendar, leap-year compensation, target date Data communication KMP protocol with CRC16 used for optical communication and for base modules Power in temperature sensors < 10 µW RMS sensors Supply voltage 3.6 VDC ± 0.1 VDC Battery The replacement interval is reduced by using data modules, at frequent data communication and at high ambient temperature. Mains supply 230 VAC +15/-30%, 50/60 Hz 24 VAC ±50%, 50/60 Hz Insulation voltage 4 kV Power supply < 1 W Back-up supply Integral super-cap eliminates operational stop-down due to short- term power cuts. EMC data Meets EN 1434 class A (MID class E1) Electrical data
  • 11. 115810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Electrical data Temperature measurement T1 Flow temperature T2 Return temperature ∆Θ(T1-T2) Heat metering ∆Θ(T2-T1) Cooling metering 402-V 2-W Pt100 Measuring range 0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00K 402-W/T 2-W Pt500 Measuring range 0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00K Pulse inputs VA and VB VA: 65-66 and VB: 67-68 via module Water meter connection FF(VA) and GG(VB) = 01…40 Pulse input 680 kΩ pull-up to 3.6 V Pulse ON < 0.4 V for > 30 msec. Pulse OFF > 2.5 V for > 1.1 sec. Pulse frequency < 0.5 Hz Electrical isolation No Max. cable length 25 m Requirements to external contact Leakage current at function open < 1 µA Pulse outputs CE and CV Energy (16-17) Volume (18-19) via module The pulse outputs can be configured for heat or cooling energy Type Open collector (OB) Pulse length Programmable 32 msec. or 100 msec. External voltage 5…30 VDC Current 1…10 mA Residual voltage UCE ≈ 1 V at 10 mA Electrical isolation 2 kV Max. cable length 25 m
  • 12. 12 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Environment class Meets EN 1434 class A (MID class E1) Ambient temperature 5…55°C, non condensing, closed location (indoor installation) Protection class – Calculator IP54 – Flow sensor IP65 Media temperature – Heat meters 402-V/W: 15…130°C – Cooling meters 402-T: 2…50°C – Heat/Cooling meters 402-T: 2…130°C – Media in flow sensor Water Storage temperature -20…60°C (drained flow meter) Pressure step (with thread) PN16 Pressure step (with flanges) PN25 Weight From 1.8 to 12 kg depending on the size of the flowpart Flow sensor cable 1.5 m (the cable cannot be removed) Connection cables ø3.5…6 mm Supply cable ø5…10 mm Mechanical data At medium temperatures over 90°C in the flow sensor, we recommend using flange meters and mounting the calculator on the wall.
  • 13. 135810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Wetted parts Housing, gland DZR brass (dezincification resistant) Housing, flange Stainless steel, W.no. 1.4308 Transducers Stainless steel, W.no. 1.4401 Gaskets EPDM Measuring tube Thermoplastic, PES 30% GF Reflectors Thermoplastic, PES 30% GF and Stainless steel, W.no. 1.4301 Flow sensor housing Top/wall brackets Thermoplastic, PC 20% GF Calculator casing Top cover Thermoplastic, PC Base unit Thermoplastic, ABS with TPE gaskets (thermoplastic elastomer) Internal cover Thermoplastic, ABS Flow sensor cable Silicone cable with internal teflon insulation Materials
  • 14. 14 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Accuracy Sub-units of the heat meter MPE according to EN 1434-1 MULTICAL® 402, typical accuracy Flow sensor Ef = ±(2 + 0.02 qp/q) % Ef = ±(1 + 0.01 qp/q) % Calculator Ec = ±(0.5 +∆Θmin /∆Θ) % Ec = ±(0.15 + 2/∆Θ) % Sensor set Et = ±(0.5 + 3∆Θmin /∆Θ) % Et = ±(0.4 + 4/∆Θ) % -6,0 -4,0 -2,0 0,0 2,0 4,0 6,0 0,01 0,10 1,00 10,00 q [m³/h] Tol[%] Ec+Et+Ef (EN) Ec+Et+Ef (Typ) MULTICAL ® 402 qp 1,5 m³/h @ ∆Θ 30KMULTICAL® 402 qp 1.5 m³/h @ ∆Θ 30K
  • 15. Order specifications 155810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T Sensor connection Pt100 V Pt500 W Pt500 (with condensation protected flow sensor for cooling) T Modules No module 00 Data + 2 pulse inputs (VA, VB) 10 Data + 2 pulse outputs (CE, CV) 11 M-Bus + 2 pulse inputs (VA, VB) 20 M-Bus + 2 pulse outputs (CE, CV) 21 M-Bus + 2 pulse inputs (VA, VB), MULTICAL® III Data Package 29 Wireless M-Bus, EU, 868 MHz, Mode C1 30 Wireless M-Bus, EU, 868 MHz, Mode C1 (Individual key), alternative registers, +VA, VB 35 Wireless M-Bus, EU, 868 MHz, Mode T1 (Common key) 37 Radio, EU, 434 MHz, int. ant., NET0 40 Radio, EU, 434 MHz, int. ant., NET1 41 Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse inputs (VA, VB) 42 Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse outputs (CE, CV) 43 Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse inputs (VA, VB) 44 Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse outputs (CE, CV) 45 Radio, SE, 444 MHz, int. ant., NET0 + 2 pulse inputs (VA, VB) 50 Radio, SE, 444 MHz, int. ant., NET1 + 2 pulse inputs (VA, VB) 52 Radio, SE, 444 MHz, ext. ant., NET0 + 2 pulse inputs (VA, VB) 54 Radio, SE, 444 MHz, ext. ant., NET1 + 2 pulse inputs (VA, VB) 56 Supply No module 0 Battery, 2 x AA 1 Battery, D-cell 2 230 VAC supply module 7 24 VAC supply module 8 Pt500 sensor set No sensor set 00 Pocket sensor set with 1.5 m cable 0A Pocket sensor set with 3.0 m cable 0B Short direct sensor set with 1.5 m cable 0F Short direct sensor set with 3.0 m cable 0G Flow sensor qp [m³/h] Connection Length [mm] 0.6 G¾B (R½) 110 1 0.6 G1B (R¾) 190 3 1.5 G¾B (R½) 110 4 1.5 G¾B (R½) 165 5 1.5 G1B (R¾) 130 7 1.5 G1B (R¾) 190 9 2.5 G1B (R¾) 130 A 2.5 G1B (R¾) 190 B 3.5 G5/4B (R1) 260 D 6.0 G5/4B (R1) 260 F 6.0 DN25 260 G 10 G2B (R1½) 300 H 10 DN40 300 J 15 DN50 270 K Meter type Heat meter (MID: module B+D) 2 Heat meter (MID: module B+D, only MULTICAL® 402 T) 3 Heat meter 4 Cooling meter (only MULTICAL® 402 T) 5 Heat/cooling meter (only MULTICAL® 402 T) 6 Volume meter (hot) 7 Volume meter (cold, only MULTICAL® 402 T) 8 Energy meter 9 Country code (language on lable etc.) XX MULTICAL® 402 Type 402          
  • 16. Dimentional sketches Mechanical measurements of the electronics unit Flow sensor with G¾ and G1 thread connection. Thread ISO 228-1. Thread L M H2 A B1 B2 H1 Approx. weight [kg] G¾ 110 L/2 89 10.5 50.5 35 48.5 1.4 G1 (qp 1.5) 130 L/2 89 20.5 50.5 35 48.5 1.5 G1 (qp 2.5) 130 L/2 89 20.5 50.5 35 48.5 1.4 G¾ 165 L/2 89 20.5 50.5 35 48.5 1.8 G1 (qp 1.5) 190 L/2 89 20.5 50.5 35 48.5 2.0 G1 (qp 2.5) 190 L/2 89 20.5 50.5 35 48.5 1.9 Weight includes a 3 m Short direct sensor set, but is excluding packing. 16 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 17. Dimentional sketches Flow sensor with G5/4 and G2 thread connection. Thread ISO 228-1. Thread L M H2 A B1 B2 H1 Approx. weight [kg] G5/4 260 L/2 88.7 17 50.5 22 48.5 2.9 G2 300 L/2 88.7 21 50.5 31 48.5 5.1 Weight includes a 3 m Short direct sensor set, but is excluding packing. 175810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 18. Weight includes a 3 m short direct sensor set, but is excluding packing. Flow sensor with DN25 to DN50 flange connection. Flange EN 1092, PN25. Dimentional sketches Nom. diameter Bolts Approx. weight L M H2 D H k Number Thread d2 [kg] DN25 260 L/2 92.5 115 106 85 4 M12 14 5.6 DN40 300 L/2 92.5 150 136 110 4 M16 18 8.9 DN50 270 155 92.5 165 145 125 4 M16 18 10.7 18 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 19. Pressure loss MULTICAL 0,01 0,1 1 0,1 1 10 100 Flow [m³/h] ∆p[bar] A B C ∆p MULTICAL® 402 Graph qp [m³/h] Nom. diameter [mm] kv Q@0,25 bar [m³/h] A 0.6 & 1.5 DN15 & DN20 3 1.5 B 2.5 & 3.5 & 6 DN20 & DN25 13.5 6.8 C 10 & 15 DN40 & DN50 43 21.7 195810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T
  • 20. Type number Description 402-000-1000-000 Battery module 2 pcs. AA-cell 402-000-2000-000 D-cell battery 402-000-7000-000 230 VAC supply module 402-000-8000-000 24 VAC supply module 66-99-097 USB cable with galvanic separation 66-99-099 Infra-red optical reading head with USB plug 66-99-102 Infra-red optical reading head RS232 with D-sub 9F 66-99-106 Data cable RS232, D-sub 9F 66-99-108 Pc-Interface cable RS232 for MULTICAL® 66-99-372 Pt500 (Heat) Verification Equipment for MULTICAL® 402 (used with METERTOOL) 66-99-373 Pt500 (Cooling) Verification Equipment for MULTICAL® 402 (used with METERTOOL) 66-99-712 METERTOOL for MULTICAL® 402 66-99-713 METERTOOL LogView for MULTICAL® 402 Accessories Glands including gaskets (PN16) Gaskets Size Nipple Union Type No. 2 pcs DN15 R½ G¾ 65-61-323 DN20 R¾ G1 65-61-324 DN25 R1 G5/4 65-61-325 DN40 R1½ G2 65-61-315 For glands For flange meters PN25 Size (Union) Type No. Size Type No. G¾ 2210-061 DN20 2210-147 G1 2210-062 DN25 2210-133 G5/4 2210-063 DN40 2210-132 G2 2210-065 DN50 2210-099 20 5810725_F1_GB_01.2013 MULTICAL® 402 D A T A S H E E T