1. Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk
Flostar M
Designed to meet the advanced needs of water utilities in large revenue collection applications
Engineered for reliability and built upon 20 years of industry-leading design, Itron’s Flostar M is the best
choice for drinking water metering in commercial and industrial applications.
FEATURES AND BENEFITS
Reliability
Endurance & Peak Flow Resistance
» Low flow accuracy
Flostar M features a direct magnetic
transmission between the turbine and the
register without any intermediate gearing
in the metered water.
Performance over time is a key
requirement for efficient billing. Flostar M
features a patented turbine ball pivoting
enhancing endurance at low flow-rates.
Hydrodynamic balance and turbine
design bring resistance at high and peak
flows.
» Peak flow capacity
» Highly engineered materials
Wide Measuring Range
Flostar M is a single jet meter available in
sizes from DN 40 to 150.
Its metrological performances far exceed
ISO/EEC Class C standards.
Its low flow accuracy range combined
with significant peak flow capacity ensure
complete and efficient measurement
whatever the faced flow-rates.
WATER
This results in a very robust and reliable
design able to withstand most types of
potable water environments.
Ease of read in the toughest humid
environments (ie: flooded pits) is secured
by hermetically sealed IP68 register
(copper can/mineral glass envelope).
Simple an effective
Simple but highly engineered materials
and design enable a very long durability
and the best performances for water
metering.
knowledge to shape your future
2. » Single jet Class C
WORKING PRINCIPLE
» Hermetically sealed register
(coppercan/mineral glass envelope)
Flostar M is a single jet meter. The water
jet is canalized by an injector before hitting
the turbine. The single jet tapered injector
» Patented ball pivot
» Patented turbine levitation
straightens the flow profile. Its large
bore area prevents meter overspeed by
clogging.
The high precision design of the inlet
1 allows Flostar M to meet best accuracy
without the need for any bypass or
calibration vane adjustment system.
The turbine movement is directly
transmitted to the extra dry register
through a magnetic coupling 2 without
the need for any intermediate gearing in
the metered water.
This allows Flostar M to conserve its
initial accuracy over time, under the most
demanding service conditions of potable
water networks.
High quality material for the turbine
bearings and patented ball pivot 3
design allows detection of leakages
initially and over time regardless of the
flow profiles. The hermetically sealed
copper can/mineral glass enveloppe of
the IP68 register 4 is safeguarding the
read and integrity of the indicator in the
toughest environments (flooded pits,
mechanical tampering attempts, ...).
4
Flostar M DN 150
2
1
3
Flostar M DN40 3D Section
Flostar M indicator
COMMUNICATION :
READY FOR SMART METERING
Flostar M is supplied pre-equipped
with Cyble Target
Allows communication and remote
reading through:
» Pulse output (Cyble Sensor)
» M-Bus protocol (Cyble M-Bus)
» Radio frequency wireless link (Cyble RF)
These Cyble modules allow the Flostar
M meter to be connected with various
associated systems like our supervision
system WaterMind (see specfic leaflet).
They are particularly adapted to
commercial and industrial applications
where a need for frequent meter
monitoring is expressed especially in
hard-to-read locations.
Cyble RF fitted on Flostar M
Key Advantages of Cyble Technology
» No need for additional investment on
the meter to implement remote reading
» Itron standardized meter interface,
irrespective of meter technology and
widely spread on Itron water meters
range
» Reliability brought by electronic switch
(no wear or bouncing)
» Reverse flow management
» Principle proven on the field with a 25
years experience
» Pre-equipment being immune to
magnetic tampering
3. METROLOGICAL CHARACTERISTICS
MID / ISO 4064-1:2005 / OIML R49 Approval Values
MID Approval Certificate
N°LNE - 7305 and N°LNE - 11437
Nominal diameter (DN)
mm
40
50
65
≥ 100*
≥ 160
16
20
≤ 160
160
Minimal flowrate
(Q1)
l/h
Transition flowrate
(Q2)
l/h
Permanent flow rate
(Q3) m3/h
Overload flowrate
(Q4) m3/h
Dynamic
(Q3/Q1)
Standard Ratio
(Q3/Q1)
Q2/Q1
Accuracy class
Temperature class
°C
Maximum Admissible Pressure bar
Orientation
Indicating range
m3
Verification scale interval
L
Climatic influence class
≥ 100*
≥ 160
25
31.25
≤ 250
250
≥ 127*
≥ 203
40
50
≤ 400
315
80
100
≥ 157.5*
≥ 252
63
78.75
≤ 400
315
1.6
2
150
≥ 250*
≥ 400
100
125
≤ 400
315
≥ 254*
≥ 406
160
200
≤ 630
315
T50
16
Horizontal
999999
0.5
+5°C ; +55°C
T30
20
Horizontal
9999999
2
-
* respectively with dynamics Q3/Q1
Qmin
Qmin/2
Qmax
ISO 4064-1 : 1993 Class C
FLOSTAR M Real Capabilities
1,25 x Qmax
Performance Values
Nominal diameter (DN)
Mobile Flanges
mm
40
50 or 65
inches 1” ½
Starting flow*
l/h
Accuracy ± 2% from*
l/h
Accuracy ± 5% from*
l/h
Admissible peak flow
m3/h
(2 hrs. max.)**
Max. temperature for short period °C
Max. admissible pressure
bar
Cyble HF pulse weight
L
65 or 80
2” or 2” ½ 2” ½ or 3”
22
65
45
32
80
60
50
100
150
3” or 4”
4” or 6”
6”
50
180
120
70
280
170
90
300
200
90
135
260
35
120
100
40
80 or 100
60
60
16
20
10
100
* Average values - ** Without impact on accuracy performances.
EEC/ISO Approval Values
Nominal diameter (DN)
mm
40
inches 1” ½
EEC/ISO class approval
Nominal flow rate
Qn
m3/h
Maximum flow rate
Qmax m3/h
Accuracy ± 2% class C Qt
l/h
Accuracy ± 5% class C Qmin
l/h
Testing pressure
bar
Max. temperature
°C
Headloss group
bar
Min. scale interval
L
Indicating range
DN 40 to 100
DN 150
EEC approval
DN 40 to 100
certificate
DN 150
50 or 65
65 or 80
2” or 2” ½ 2” ½ or 3”
10
20
150
100
15
30
225
90
25
1
80 or 100
100
150
3” or 4”
4” or 6”
6”
Class C horizontal position
20
30
40
60
300
450
120
180
32
30
0.6
0.5
50
100
750
300
100
200
1500
600
1
5
999 999.99 m3
9999 999.9 m3
F06-G1546
F-06-G-219
* DN 65, 80 and 100 approved in class B other positions.
TYPICAL ACCURACY CURVE, FLOSTAR M QN 30 M3/H
8
Error (%)
6
4
2
0
-2
-4
-6
Flow-rate (m3/h)
-8
0.1
1
10
100
Flostar M from DN65 to DN 150
is equipped with mobile flanges
allowing easy installation in a
horizontal position.