2. 2222
At Harihar, Karnataka
ïź TurboTech Supplied and Commissioned a
3000 KW Steam Turbine to Customer Atria Power
Corporation
ïź This CSP Plant is Located at Harihar, Karnataka
ïź The plant is dedicated for solar energy production.
The first phase being this 3MW project.
ïź Plant began operations in 2012.
3. 3333
ECT â As Offered To Atria Power, Harihar
Plant Type: Concentrated Solar Power Plant
Application: Steam Turbine installed and power being given to Grid
Type of Turbine: Bleed Cum Condensing Turbine
Voltage: 415 V
Frequency: 50 Hz
Design Inlet Pressure: 34 Bar (g)
Design Inlet Temp: 350 deg C
Bleed To Deaerator: 2.4TPH
Pressure to Dearator: 2.4 Bar(g)
Design Exit Pressure: 0.1 ata
Turbine Power Output: 3000 kW
6. Energy and Cost Savings through Turbine
Installation at Atria Power
Energy Savings:
Electricity Units Saved per Hour: 3000
No of Days Plant Operating Per Year: 330
Cost Savings:
Total Cost Savings from Year 2002
Till Date: 3.0 Crores
Rupees
7. Mini Steam Turbines
Support Fight Global Warming
Apart from Supporting Energy and Cost Savings, Turbo Tech's CSP based Steam
Turbines Support in Fighting Global Warming as ELECTRIC POWER generated
through the turbines in these type of applications are GREEN in nature with no
burning of Fossil Fuel
The Subject Turbine at Atria Power Corporation has prevented about 5,000 Tons
of CO2 (Carbon Di Oxide â Green House Gas that causes Global Warming)
release to the Atmosphere over these 6 months of Operation, a significant
contribution to a Green and Safe Environment at a Mini Level